HomeMy WebLinkAboutEnergy CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business, and Professional Regulation - Residential Performance Method
Project Name: Lot 39 Block 1 Waterstone 1820 DGL
Builder Name: ADAMS HOMES
Street: 5459 Lugo Street
Permit Office:
City, State, Zip: Fort Pierce , FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall TypeP120.0 sqft.)
Insulation Area
I
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1850.00 ft2
b. Frame -Wood, Adjacent
R=13.0 270.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. NA
R= ft2
5. Is this a worst case? No
11. Ceiling Types (1900.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1820.00 ft2
6. Conditioned floor area above grade (ft2) 1820
b. Knee Wall (Vented)
R=19.0 80.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(237.2 sqft.) Description Area
12. Ducts
R ft2
a. Sup: Attic, Ret: Main, AH: Main
6 364
a. U-Factor: Dbl, U=0.33 168.74 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 18.33 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.31
a. Central Unit
35.0 SEER:16.00
c. U-Factor: Dbl, U=0.55 17.78 ft2
SHGC: SHGC=0.70
Area Weighted Average Overhang Depth: 4.069 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.269
a. Electric Heat Pump
34.6 HSPF:8.20
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (1820.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Total Proposed Modified Loads: 59.67
Glass/Floor Area: 0.130
PASS
Total Baseline Loads: 64.94
I hereby certify that the plans a p ations covered b
-R'ev-ie4.of the plans and
STA7�
this calculation are in compli c the Florid gy
specifications covered by this
o�iE
Code.
calculation indicates compliance
w �i�', 9z,,��;�`
with the Florida Energy Code.
grrrr`", -•; . ;,�. �� O
PREPARED BY:
Before construction is completed
r .F
DATE: 02-09-2021 Winn Keomany
this building will be inspected for
compliance with Section 553.908
.i�
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida E-e-emy Code.
G+OD_v.
OWNER/AGENT
BUILDING OFFICIAL:
_
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and thisRM requires an
'envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
PUR 0 51011
►'ermitting Department
"' 1 imp r'nnnh,
2/9/2021 5:24 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
FORM R405-2020
INPIIT RH MARV rWr:rVl ICT QGanOT
PROJECT
Title:
Lot 39 Block 1 Waterstone
18 Bedrooms: 4
Address Type:
Lot Information
Building Type:
User
Conditioned Area: 1820
Lot #
39-1
Owner Name:
Total Stories: 1
Block/Subdivision:
Waterstone
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
ADAMS HOMES
Rotate Angle: 0
Street:
5459 Lugo Street
Permit Office:
Cross Ventilation: No
County:
St. Lucie
. Jurisdiction:
661000
Whole House Fan: No
City, State, Zip:
Fort Pierce ,
Family Type:
Detached
FL, 34951
New/Existing:
New (From Plans)
Comment:
i
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
�/ Design Location
TMY Site 97.5 % 2.5 %
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
1820 18200
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InflIID Finished Cooled Heated
1
Main
1820 18200 Yes 5
.4 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 33 ft 0
1820 ft2
0.42 0 0.58
ROOF
/
Roof Gable Roof
Rad Solar SA Emitt
Emitt Deck Pitch
#
Type
Materials Area Area Color
Barr Absor. Tested
Tested Insul. (deg)
1
Gable or Shed Composition shingles 2035 ft2 456 ft2 Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1820 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main, 30 Blown
1820 ft2 0.11
Wood
2
Knee Wall (Vented)
Main 19 Batt
80 ft2 0.11
Wood
2/9/2021 5:24 PM
EnergyGauge® USA
7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software
Page 2 of 4
FORM R405-2020 INPUT SUMMARY I^14FrKI IST RFPnRT
WALLS
#
Ornt
Adjacent
To
Wall JypF,Ft
Space
vity Width
Catje In
Height
Et In
Area
Sheathing Framing Solar Below
13-11able Fraction Ahsnr Grade%
1
NE
Exterior
Concrete Block - Int Insul
Main
4.1 59
0
10 0
590.0 ft2
0
0 0.6
0
2
SE
Exterior
Concrete Block - Int Insul
Main
4.1 13
0
10 0
130.0 ft2
0
0 0.6
0
3
SW
Exterior
Concrete Block - Int Insul
Main
4.1 66
0
10 0
660.0 ft2
0
0 0.6
0
4
NE
Exterior
Concrete Block - Int Insul
Main
4.1 27
0
10 0
270.0 ft2
0 0.6
0
5
-
Garage
Frame - Wood
Main
13 27
0
10 0
270.0 ft2
0
0.23 0.01
0
6
SE
Exterior
Concrete Block - Int Insul
Main
4.1 7
0
10 0
70.0 ft2
0
0 0.6
0
7
NW
Exterior
Concrete Block - Int Insul
Main
4.1 13
0
10 0
130.0 ft2
0 0.6
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
SE
Insulated
Main
None
.25
3
6 8
20 ft2
2
-
Wood
Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Ornt ID
Frame Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
NE 1
Vinyl Low-E Double
Yes
0.33 0.23
N
6.9 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
2
NE 1
Vinyl Low-E Double
Yes
0.33 0.23
N
48.6 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
3
SE 6
Vinyl Low-E Double
Yes
0.33 0.31
N
5.0 ft2
9 ft 0 in
0 ft 6 in
Drapes/blinds
Exterior 5
4
SE 2
Vinyl Low-E Double
Yes
0.33 0.21
N
16.2 ft2
1 ft 4 in
1 ft 0 in
Drapes/blinds
Exterior 5
5
SE 2
Vinyl Low-E Double
Yes
0.3 0.21
N
16.2 ft2
1 ft 4 in
1 ft 0 in
Drapes/blinds
Exterior 5
6
SE 6
Vinyl Low-E Double
Yes
0.33 0.31
N
13.3 ft2
9 ft 0 in
2 ft 0 in
Drapes/blinds
Exterior 5
7
SW 3
Vinyl Low-E Double
Yes
0.33 0.23
N
48.6 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
8
NW 7
Vinyl Low-E Double
Yes
0.55 0.7
N
17.8 ft2
11 ft 5 in
0 ft 6 in
Drapes/blinds
Exterior 5
9
NE 4
Vinyl Low-E Double
Yes
0.33 0.23
N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
10
NW 7
Vinyl Low-E Double
Yes
0.33 0.23
N
32.4 ft2
11 ft 6 in
0 ft 6 in
Drapes/blinds
Exterior 5
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
396 ft2 396 ft2
64 ft
8 ft
1
INFILTRATION
# Scope
Method SLA
CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000444
2123.3 116.49
218.7
.1381
7
2/9/2021 5:24 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2020 INPUT SUMMARY CHFCKI IST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Singl HSPF:8.2
34.6 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 16
35 kBtu/hr
cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
DUCTS
/ - -- Supply ----
�/ # Location R-Value Area
---- Return ----
Location Area Leakage Type
Air
Handler
CFM 25 CFM25
TOT OUT QN
RLF
HVAC #
Heat Cool
1 Attic
6 364 ft2
Main
91 ft2 Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
CoolingJan Feb
HeatinJan Feb
Ventin Jan Feb
Mar
Pq Mar
Mar
[
Ceiling Fans:
Jul
Apr May Jun Jul
A r Ma rj Junri
A r [ Ma Jun Jul
Au
f AuSeP
[ Aug
Se
ri Se [X]
Oct
Oct
Oct
Nov
Nov
Nov
Dec
XDec
[ ] Dec
Thermostat Schedule: HERS 2006 Reference
Schedule Type 1
2
3
Hours
4 5 6 7
8 9
10
11
12
Cooling (WD) AM
PM
Cooling (WEH) AM
PM
Heating (WD) AM
PM
Heating (WEH) AM
PM
78
80
78
78
66
68
66
68
78
80
78
78
66
68
66
68
78
78
78
78
66
68
66
68
78 78 78
78 78 78
78 78 78
78 78 78
66 66 68
68 68 68
66 66 68
68 68 68
78
78
78
78
68
68
68
68
78 80
78 78
78 78
78 78
68 68
68 68
68 68
68 68
80
78
78
78
68
68
68
68
80
78
78
78
68
66
68
66
80
78
78
78
68
66
68
66
MASS
Mass Type
Area
Thickness Furniture Fraction Space
Default 8 Ibs/s .ft.
0 ft2
0 ft
0.3
Main
2/9/2021 5:24 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 92
The lower the EnergyPerformance Index, the more efficient the home.
5459 Lugo Street, Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1850.00 ft2
3. Number of units, if multiple family
1
b. Frame - Wood, Adjacent
R=13.0
270.00 ft2
c. N/A
R=
ft2
4. Number of Bedrooms
4
d. N/A
R=
ft2
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
1820.00 ft2
6. Conditioned floor area (ft2)
1820
b. Knee Wall (Vented)
R=19.0
80.00 ft2
7. Windows** Description
Area
c. N/A
R=
ft2
a. U-Factor: Dbl, U=0.33
168.74 ft2
12. Ducts, location & insulation level
R ft2
SHGC: SHGC=0.23
a. Sup: Attic, Ret: Main; AH: Main
6 364
b. U-Factor: Dbl, U=0.33
18.33 ft2
SHGC: SHGC=0.31
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.55
17.78 ft2
a. Central Unit
35.0 SEER:16.00
SHGC: SH6C=0.70
d. U-Factor: other (see details)
32.38 ft2
SHGC: other (see details)
14. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
4.069 ft.
a. Electric Heat Pump
34.6
HSPF:8.20
Area Weighted Average SHGC:
0.269
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
2
ft2
a. Electric
Cap:
40 gallons
SHGC(AVG): N/A
EF:0.94
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
1820.00 ft2
Credits (Performance method)
Pstat
b. N/A
R=
ft2
c. N/A
R=
ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:Date:
Address of New Home: City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
M Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
2/9/2021 5:24 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1