HomeMy WebLinkAboutEnergy Codew
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
S
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 123 Block 5 Waterstone 1820 BGRNE
Builder Name: ADAMS HOMES
Street: 5354 San Benedetto Place
Permit Office:
City, State, Zip: Fort Pierce, FL, 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type(2120.0 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1850.00 ft2
3. Number of units, if multiple family 1
b. Frame - Wood„Adjacent
c. N/A
R=13.0 270.00 ft2
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (1900.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1820.00 ft2
6. Conditioned floor area above grade (ft2) 1820
b. Knee Wall (Vented)
R=19.0 80.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(239.3 sqft.) Description Area
12. Ducts
R ft2
a. U-Factor: Dbl, U=0.33 168.74 ft2
a. Sup: Attic, Ret: Main, AH: Main
6 364
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 32.38 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:16.00
c. U-Factor: Dbl, U=0.33 20.42 ft2
SHGC: SHGC=0.31
Area Weighted Average Overhang Depth: 3.999 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.269
a. Electric Heat Pump
34.6 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (1820.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.131 Total Proposed Modified Loads: 63.73
PASS
Total Baseline
Loads: 65.00
I hereby certify that the plans �ifications covered ^
e ' w of the plans and
�I VE &T�g3F
this calculation are in com ith the Flori ergy
specifications covered by this
d
Code.
calculation indicates compliance
with the Florida Energy,Code.
PREPARED BY:
Before construction is completed0.
DATE: 112-05-21121 Winn KPny
this building will be inspected for
compliance with Section 553.908
�„ _ y
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
y,S
with the Florida Energy Code._
hGpD.flt
OWNER/AGENT
BUILDING OFFICIALDATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (111402AA.2).
• i RECENED
.al
�� MAR 0 5 7411.1
oft. LU county
2/5/2021 9:27 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Sof ware Page 1 of 4
FORM R405-2020 INPI IT RI IMMAPY rl-11=9-L(il icT OCOADT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 123 Block 5 Waterstone 1 Bedrooms: 4
User Conditioned Area: 1820
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Detached
New (From Plans)
Address Type: Street Address
Lot # 123-5
Block/Subdivision: Waterstone
PlatBook:
Street: 5354 San Benedetto PI
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL, 34951
CLIMATE
/
Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST—LUCIE_CO—INTL FL—VERO—BEACH—MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
1820 18200
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1820 18200 Yes 5
4 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 33 ft 0
1820 ftz ---- 0.42 0 0.58
ROOF
/
V/ #
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 2035 ftz 456 ft2 Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1820 ft' N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
2
Under Attic (Vented)
Knee Wall (Vented)
Main 30 Blown
Main 19 Batt
1820 ftZ 0.11 Wood
80 ftz 0.11 Wood
2/5/2021 9:27 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space
Cavity Width Height
Sheathing Framing Solar Below
0
1 NW Exterior Concrete Block - Int Insul Main
4.1 59 0 10 0
590.0 ft2
0
0 0.6
0
2 NE
Exterior Concrete Block - Int Insul Main
4.1 20 0 10 01
200.0 ft2
0
0 0.6
0
3 SE
Exterior Concrete Block - Int Insul Main
4.1 66 0 10 0
660.0 ft2
0
0 0.6
0
4 SE
Exterior Concrete Block - Int Insul Main
4.1 40 0 10 0
400.0 ft2
0 0.6
0
5 -
Garage Frame - Wood Main
13 27 0 10 0
270.0 ft2
0
0.23 0.01
0
DOORS
#
Ornt Door Type Space
Storms U-Value
Width
Height
Area
Ft
In
Ft In
1
NE Insulated Main
None 25
3
6 8
20 ft2
2
- Wood Main
None .25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
#
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp Area
Depth
Separation
Int Shade
Screening
1
NW 1 Vinyl Low-E Double Yes
0.33 0.23 N 6.9 ft2
1 ft 4 in
0 ft 10 in
None
None
2
NW 1 Vinyl Low-E Double Yes
0.33 0.23 N 48.6 ft2
1 ft 4 in
0 ft 10 in
None
None
3
NE 2 Vinyl Low-E Double Yes
0.33 0.31 N 7.1 ft2
9 ft 0 in
0 ft 6 in
None
None
4
NE 2 Vinyl Low-E Double Yes
0.33 0.21 N 16.2 ft2
1 ft 0 in
3 ft 11 in
None
None
5
NE 2 Vinyl Low-E Double Yes
0.33 0.21 N 16.2 ft2
1 ft 0 in
5 ft 4 in
None
None
6
NE 2 Vinyl Low-E Double Yes
0.33 0.31 N 13.3 ft2
9 ft 0 in
2 ft 0 in
None
None
7
SE 3 Vinyl Low-E Double Yes
0.33 0.23 N 48.6 ft2
1 ft 4 in
0 ft 10 in
None
None
8
SE 4 Vinyl Low-E Double Yes
0.55 0.7 N 17.8 ft2
10 ft 6 in
0 ft 6 in
None
None
9
SE 4 Vinyl Low-E Double Yes
0.33 0.23 N 32.4 ft2
1 ft 4 in
0 ft 10 in
None
None
10
SE 4 Vinyl Low-E Double Yes
0.33 0.23 N 32.4 ft2
11 ft 6 in
0 ft 6 in
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height
Exposed Wall Insulation
1
396 ft2 396 ft2
64 ft 8 ft
1
INFILTRATION
# Scope
Method SLA CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000444 2123.3 116.49 218.7
.1381
7
HEATING SYSTEM
#
System Type Subtype
Speed Efficiency Capacity
Block
Ducts
1
Electric Heat Pump/ Split
Singl HSPF:8.5 34.6 kBtu/hr
1
sys#1
2/5/2021 9:27 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2020 INP11T RI IMMARY rNFrki IQT D=DnQT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 16
35 kBtu/hr
cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cent # Company Name
System Model # Collector
Model
# Area
Volume
FEF
None None
ftz
DUCTS
/ ---- Supply ----
---- Return ----
Air
CFM 25 CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT
QN
RLF
Heat Cool
1 Attic
6 364 ft2
Main
91 ft' Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan Feb
HeatinJan f X Feb
Mar
f X� Mar
f
A r
APr I
Ma rjJun Jul
May Jun Jul
ri
Au
AuSepOct
ri
Se
ri
Oct
Nov
Nov
Dec
Dec
Ventin Jan [ Feb
X Mar
[
A r
May Jun Jul
Aug
Se [X]
Oct
X Nov
Dec
Thermostat Schedule: HERS 2006
Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8 9
10
11
12
Cooling (WD) AM
78
78
78
78 78 78
78
78 80
80
80
80
PM
80
80
78
78 78 78
78
78 78
78
78
78
Cooling (WEH) AM
78
78
78
78 78 78
78
78 78
78
78
78
PM
78
78
78
78 78 78
78
78 78
78
78
78
Heating (WD) AM
66
66
66
66 66 68
68
68 68
68
68
68
PM
68
68
68
68 68 68
68
68 68
68
66
66
Heating (WEH) AM
66
66
66
66 66 68
68
68 68
68
68
68
PM
68
68
68
68 68 68
68
68 68
68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction Space
Default 8 Ibs/s .ft.
0 ftz
0 ft
0.3
Main
2/5/2021 9:27 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
5354 San Benedetto Place, Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1850.00 ft2
b. Frame - Wood, Adjacent
R=13.0
270.00 ft2
3. Number of units, if multiple family
1
c. N/A
R=
ft2
4. Number of Bedrooms
4
d. N/A
R=
ft2
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
1820.00 ft2
6. Conditioned floor area (ft2)
1820
b. Knee Wall (Vented)
R=19.0
80.00 ft2
7. Windows" Description
Area
c. N/A
R=
ft2
a. U-Factor: Dbl, U=0.33
168.74 ft2
12. Ducts, location & insulation level
R ft2
SHGC: SHGC=0.23
a. Sup: Attic, Ret: Main, AH: Main
6 364
b. U-Factor: Dbl, U=0.33
32.38 ft2
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.33
20.42 ft2
a. Central Unit
35.0 SEER:16.00
SHGC: SHGC=0.31
d. U-Factor: other (see details)
17.78 ft2
SHGC: other (see details)
14. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
3.999 ft.
a. Electric Heat Pump
34.6
HSPF:8.50
Area Weighted Average SHGC:
0.269
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
2
ft2
a. Electric
Cap:
40 gallons
SHGC(AVG): N/A
EF:0.94
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
1820.00 ft2
Credits (Performance method)
Pstat
b. N/A
R=
ft2
c. N/A
R=
ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home:
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home'may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
2/5/2021 9:27 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1