Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Truss
258 Southhall Lane, Suite 200 rF D Maitland, Florida 32751 P: (321) 972-0491 1 F: (407) 880-2304 E: info@fdseng.com Website: www.fdseng.com ENGINEERING ASSOCIATES February 17, 2021 Building Department Ref: Lot: Subdivision: Address: Model: KA # Truss Company: Date of drawings: Job No.: Wind Speed: Exposure: Truss Engineer: Adams Homes Lot 123 Blk. 5 Fort Pierce - Waterstone 5354 San Benedetto. 1820 B RHG 21-1352 Builders First Source 2/4/21 2631413 160 C Joaquin Velez To whom it may concern, We have reviewed the truss design package for the project referenced above. This truss package complies with the original design intent and the underlying structure will accommodate all indicated loads. We approve the truss package without comment based upon the truss layout and truss profiles supplied to us by the Truss Company with truss profiles sealed by the Truss Engineer. Please note, this review is only for general conformance with the design concept of the project. Contractor or sub -contractor is responsible for matching all structural components and details shown in the construction documents. Contractor or sub -contractor is also responsible for confirming all quantities and dimensions; selecting appropriate fabrication processes and techniques; and coordinating work with all other trades. Note: Truss ID's may vary. If you have any questions, please do not hesitate to call. Sincerely, 2/17/2021 Carl A. Brown, P.E. FL. # 56126 �e'V11IaIIlist P p,eLO T ''pis 5 •'•��C•E•N •F9'4���: cS� No 864 � o p•• 1��2�2QF •���: Luis I FL. # FDS Engineering Associates, A TSG Company "Your Building Code Experts" ® Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. ReK® RE: 2631413 - LOT 123/5 WATERSTONE MiTek USA, Inc. Site Information: 6904 Parke East Blvd. Customer Info: Adams Homes Port St Lucie Project Name: 2631413 Model: 1820 RImpa, FL 33610-4115 Lot/Block: 123/5 Subdivision: WATERSTONE Address: 5354 SAN BENEDETTO PL, . City: Fort Pierce State: FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: State: General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2020/TP12014 Design Program: MiTek 20/20 8.4 Wind Code: N/A Wind Speed: 160 mph Roof Load: 37.0 psf Floor Load: N/A psf This package includes 31 individual, Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Seal# Truss Name Date 1 T22727466 A01 2/4/21 2 T22727467 A02 2/4/21 3 T22727468 A03 2/4/21 4 T22727469 A04 2/4/21 5 T22727470 A05 2/4/21 6 T22727471 A06 2/4/21 7 T22727472 A07 2/4/21 8 T22727473 A08 2/4/21 9 T22727474 A09 2/4/21 10 T22727475 A10 2/4/21 11 T22727476 All 2/4/21 12 T22727477 Al2 2/4/21 13 T22727478 B02 2/4/21 14 T22727479 B03 2/4/21 15 T22727480 B04 2/4/21 16 T22727481 B05 2/4/21 17 T22727482 Cl 2/4/21 18 T22727483 C1 P 2/4/21 19 T22727484 C1 V 2/4/21 20 T22727485 C3 2/4/21 21 T22727486 C3V 2/4/21 22 T22727487 C5 2/4/21 No. Seal# Truss Name Date 23 T22727488 C5V 2/4/2j1 24 T22727489 D02 2/4/21 25 T22727490 E3 2/4/21 26 T22727491 E7 2/4/21 27 T22727492 E7V 2/4/21 28 T22727493 E7VP 2/4/21 29 T22727494 H3 2/4/21 30 T22727495 H7 2/4/21 31 T22727496 H7V 2/4/21 The truss drawing(s) referenced above have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by Builders FirstSource (Plant City, FL). Truss Design Engineer's Name: Velez, Joaquin My license renewal date for the state of Florida is February 28, 2023. IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. RECEIVED MAR 0 5 7071 permitting Department St. Lucie County February 4,2021 Velez, Joaquin 1 of 1 Job Truss Truss Type City Ply 12315 WATERSTONET22727466 :LOT 2631413 A01 SPECIAL 8 1Reference (optional) owwers nrstouurce lriant uay. I-L), mant L.ny, rL - 33oor, 6.43u s Nov 3U ZUZU MI I eK Industries, Inc. Thu Feb 4 10:04:02 2021 Page 1 ID:193QGWBBpX3jRI87zeOm7kz5?ad-3Qs64vusozVv4DFI5BLyF WSn8ZaYzVcTXgQZf4zoYgB r1-4-0 6-3-0 11-11-12 19-10-0 27-8-4 3%5-0 39-8-0 41-0-Q 1-0-0 6-3-0 5-8-12 7-104 7-10-4 5-8-12 6-3-0 Scale = 1:73.6 5x6 = 6.00 12 46 = 4x10 MT20HS % 3.00 FIT 8-8-0 39-8.0 4xl0 MT20HS Zz Iv �N 0 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 LUmberDOL 1.25 Rep Stress Incr YES Code FBC2020/TPI2014 CSI. TC 0.91 BC 0.90 WB 0.71 Matrix-MSH DEFL. Vert(LL) Vert(CT) Horz(CT) in (loc) I/defl L/d -0.63 10-11 >759 240 -1.1510-11 >413 180 0.59 8 n/a n/a PLATES MT20 MT20HS Weight: 197 lb GRIP 244/190 187/143 FT = 20 LUMBER- BRACING - TOP CHORD 2x4 SP M 31 'Except' TOP CHORD Structural wood sheathing directly applied. 1-4,6-9: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 5-0-10 oc bracing. BOT CHORD 2x4 SP M 31 'Except` WEBS 1 Row at midpt 6-11, 4-12 13-14,10-13: 2x4 SP No.1 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 8=0-8-0 Max Horz 2=-433(LC 8) Max Uplift 2=-797(LC 10), 8=-797(LC 10) Max Grav 2=1793(LC 15), 8=1793(LC 16) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5905/2705, 3-4=-5621/2545, 4-5=-2780/1527, 5-6=-2739/1527, 6-7=-5299/2545, 7-8=-5593/2705 BOT CHORD 2-14=-2278/5679, 12-14=-1502/3876, 11-12=-680/2253, 10-11=-1502/3376, 8-10=-2278/5061 WEBS 5-11=-449/1175, 6-11=-1486/856, 6-10=-708/2011, 7-10=-260/287, 5-12=-449/1229, 4-12=-1574/856, 4-14=-708/2191, 3-14=-246/287 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 15-10-6, Extedor(2R) 15-10-6 to 23-9-10, Interior(1) 23-9-10 to 37-0-6, Extedor(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0,wide will fit between the bottom chord and any other members, with BCDL = IO.Opsf. ?) Bearing at joint(s) 2, 8 considers parallel to grain value using ANSUTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=797, 8=797. February 4,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MRek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not • a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall w A building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the IVIiTek' fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVII 11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply 12315 WATERSTONET22727467 [LOT 2631413 A02 SPECIAL 2Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Feb 4 10:04:04 2021 Page 1 ID:193QG WBBpX3jR187zeOm7kz5?ad-?pztVaw6KbldKXPhDZOQKxX8uNHERPNI_8vgkzzoYg9 r1-4-0 6-3-0 11-11-12 19-0-0 20-8-0 27-8-4 33-5-0 39-8-0 41-0-q 1 4-0 6-3-0 5-8-12 7-0 4 1-8-0 7-0 4 5-8-12 6-3-0 1-4-0 Scale = 1:73.7 5x8 S� 3.00 12 8-8-0 LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2020/TPI2014 LUMBER - TOP CHORD 2x4 SP No.2 `Except' 1-4,7-10: 2x4 SP No.1 BOT CHORD 2x4 SP No.2 *Except* 2-16,9-11: 2x4 SP M 31 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3 , Right: 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=-417(LC 8) Max Uplift 2=-797(LC 10), 9=-797(LC 10) Max Grav 2=1540(LC 1), 9=1540(LC 1) 5x6 = 6.00 12 5x6 = 5 6 3x4 = 5x8 ZL- CS1. DEFL. in (loc) I/deft Ud PLATES GRIP TC 0.89 Vert(LL) 0.61 11-12 >787 240 MT20 244/190 BC 0.88 Vert(CT) -0.91 11-12 >522 180 MT20HS 187/143 WB 0.76 Horz(CT) 0.57 9 n/a n/a Matrix-MSH Weight: 218 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 4-8-1 oc bracing. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-4905/2784, 3-4=-4621/2623, 4-5=-2726/1752, 5-6=-1932/1439, 6-7=-2726/1752, 7-8=-4621/2623, 8-9=-4905/2784 BOT CHORD 2-16=-2350/4717, 15-16=-1549/3216, 13-15=-776/1929, 12-13=-776/1929, 11 -1 2=-1 549/3091, 9-11=-2351/4431 WEBS 3-16=-282/293, 4-16=-742/1736, 4-15=-1216/792, 5-15=-573/1132, 5-13=-267/321, 6-13=-267/320, 6-12=-573/1068, 7-12=-1137/792, 7-11=-743/1605, 8-11=-296/294 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf, BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 15-0-6, Exterior(2R) 15-0-6 to 24-7-10, Interior(1) 24-7-10 to 37-0-6, Exterior(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. t;) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0; wide will fit between the bottom chord and any other members. 8) Bearing atjoint(s) 2, 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify .. capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=797, 9=797. February 4,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with Mi rek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use; the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrlc tlon, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Qualify Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. SafetyInformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 1 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 123/5 WATERSTONE T22727468 2631413 A03 SPECIAL 2 1 Job Reference (optional) Buuaers iurce (mant cny, t-L), Fiant cny, FL - 33567, 8.430 s Nov; 30 2020 MiTek Industries, Inc. Thu Feb 4 10:04:05 2021 Page 1 ID:193QG WBBpX3jR187ieOm7kz57ad-T7XFjwwk5utUxg_tmGvft941PndrAs IvDofDGPzoYg8 r1.4-0 6-3-0 r _ 11-11-12 17-0-0 22-8.0 27-8-5 33-5-0 39-8-0 41-0-Q 1 4-0' 6-3-0 5 8-12 5-0-5 5 8.0 5-0 4 5 8-12 6-3-0 1-4-0 6.00 12 5x6 = 5x8 = Scale = 1:75.2 0 99\10 Ic 4x10 MT20HS 3.00 F12 4x10 MT20HS ZZ LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 LumberDOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2020/TPI2014 LUMBER - TOP CHORD 2x4 SP No.2 *Except* 1-4,7-10: 2x4 SP No.1 BOT CHORD 2x4 SP M 31 `Except` 13-15,11-13: 2x4 SP No.1 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=376(LC 9) Max Uplift 2=-797(LC 10), 9=-797(LC 10) Max Grav 2=1799(LC 15), 9=1801(LC 16) 17-M CSI. DEFL. in (loc) 1/defl L/d PLATES GRIP TC 0.91 Vert(LL) -0.62 11-12 >769 240 MT20 244/190 BC 0.86 Vert(CT) -1.12 11-12 >423 180 MT20HS 187/143 WB 0.71 Horz(CT) 0.60 9 n/a n/a Matrix-MSH Weight: 202 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 4-8-15 oc bracing. WEBS 1 Row at midpt 4-14, 6-14, 7-12 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5904/2977, 3-4=-5589/2795, 4-5=-2863/1738, 5-6=-2546/1644, 6-7=-2773/1738, 7-8=-5320/2795, 8-9=-5644/2977 BOT CHORD 2-15=-2526/5637, 14-15=-1660/3794, 12-14=-1034/2565, 11-12=-1660/3367, 9-11 =-2526/51 10 WEBS 3-15=-294/324, 4-15=-797/2189, 4-14=-14281799, 5-14=-420/998, 6-14=-251/253, 6-12=-420/1108, 7-12=-1355/799, 7-11=-797/2035, 8-11=-306/324 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf, BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 13-0-6, Exterior(21R) 13-0-6 to 26-7-10, Interior(1) 26-7-10 to 37-0-6, Extedor(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use ofthis truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide " will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 8) Bearing atjoint(s) 2, 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=797, 9=797. m o_ February 4,2021 WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verily the applicability of design parameters and property incorporate this design into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing WOW always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. SafetyInformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Type Qty Ply LOT 12315 WATERSTONET22727469 [Truss 2631413 SPECIAL 2 1 Job Reference o tional Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Feb 410:04:08 2021 Page 1 r1-0-I D:193QGWBBpX3j RI87zeOin 7kz5?ad-uaD33O-8L-y1z5cOpF3 o8 iS SO3S9 M-8V-0ni rt_eCN GAql Lvm.0 tttkzoYg5 05--6-9 -0 19-100-00 248-0 30517 751-4-0 3 5-5-7 3-7 1- 1-1 1--04-0 Scale = 1:73.4 6.00 12 5x6 i 24 4 2x4 3 1.5x8 STP = 23 16 n 2 yI 1 8x14 MT20HS 4x12 ; 3.00 F12 3x8 MT20HS \\ 5x6 = 3x4 = 5x6 = 25 6 26 7 15 14 29 3x8 = 4x6 = 27 5x6 8 \�4 2x4 9 30 13 12 3x8 = 8x14 MT20HS = m 0 28 1.5x8 STP = 0 d I6 4x12 zz 3x8 MT20HS // i 8-8-0 15-0-0 24-M 31-0-0 39-M 8-8-0 i 6.4-0 ' 9-8-0 6.4-0 8-8-0 Plate Offsets (X,Y)— [2:0-1-15,1-2-15], [2:0-2-14,Edge], [4:0-3-0,0-3-0], [5:0-3-0,0-2-0], [7:0-3-0,0-2-0], [8:0-3-0,0-3-0], [10:0-1-15,1-2-15], 110:0-2-14,Edge], [12:0-7-0,0-3-8], [16:0-7-0 0-3-81 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.83 Vert(LL) -0.67 13-15 >715 240 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.95 Vert(CT) -1.16 13-15 >410 180 MT20HS 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.53 Horz(CT) 0.60 10 n/a n/a BCDL 10.0 Code FBC2020rrP12014 Matrix-MSH Weight: 204 lb FT = 20 LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc pur ins. BOT CHORD 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing, Except: WEBS 2x4 SP No.3 5-3-0 oc bracing: 13-15. WEDGE WEBS 1 Row at midpt 4-15, 8-13 Left: 2x4 SP No.3, Right: 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 10=0-8-0 Max Horz 2=-335(LC 8) Max Uplift 2=-797(LC 10), 10=-797(LC 10) Max Grav 2=1804(LC 15), 10=1804(LC 16) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5834/3030, 3-4=-5622/2947, 4-5=-3283/1933, 5-6=-2934/1832, 6-7=-2836/1832, 7-8=-3175/1933, 8-9=-5371/2947, 9-10=-5595/3030 BOT CHORD 2-16=-2565/5553, 15-16=-2182/4748, 13-15=-1410/3054, 12-13=-2182/4303, 10-12=-2565/5077 WEBS 4-16=-610/1626, 4-15=-1922/1023, 5-15=-527/1184, 7-13=-527/1190, 8-13=-1814/1023, 8-12=-610/1514,6-15=-339/205,6-13=-339/205 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASIDE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 11-0-6, Extedor(2R) 11-0-6 to 18-11-10, Interior(1) 18-11-10 to 20-8-6, Extedor(2R) 20-8-6 to 28-7-10, Interior(1) 28-7-10 to 37-0-6, Exterior(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer/ Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. T ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 8) Bearing atjoint(s) 2, 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. Q) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=797, 10=797. February 4,2021 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI l-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must vedfy the applicability of design parameters and .propedy Incorporate this design into the overall _ building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MOW always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/rP/1 Duality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa; FL 36610 r Job Truss Truss Type LOT 123/5 WATERSTONET22727470 2631413 A05 SPECIAL 11 �Q7 Job Reference (optional) --..__._ ...-.---•--.............. . _„ ..,,.,..,,.,, . �- o..ou a ,.urau cuc� rvn ren uiuusuies, nw. uru reu . iu:u,+; iu tuct rage i ID:193QGWBBpX3jRl87ze0m 7kz5?ad-gzL8me_twRVn2SsrZpVgaCn8OoJgr67eN3M_xczoYg3 4 r1-4-0, 6-8-0 13 0-0 19-10-0 26-8-0 33-0-0 39-8-0 41-0-Q 1 4-0' 6-8-0 6-4-0 6-10-0 6-10-0 6 4-0 6-8-0 41 0 r 5x8 = 6.00 12 4 23 24 5x6 22 3 1.5x8 STP = 21 14 2 13 1 6x12 MT20HS = 3x4 = 5x8 % 3.00 12 3x4 = 5x8 = 5 25 266 //N-__ N\ 1 27 5x6 7 12 11 46 = 3x4 = 1 10 6x12 MT20HS = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Ildefl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.95 Vert(LL) 0.62 10-11 >762 240 TCDL 7.0 Lumber DOL 1.25 BC 0.94 Vert(CT) -0.96 11-13 >498 180 BCLL 0.0 Rep Stress Incr YES WB 0.80 Horz(CT) 0.59 8 n/a n/a BCDL 10.0 Cade FBC2020/TPI2014 Matrix-MSH LUMBER- BRACING - TOP CHORD 2x4 SP M 31 'Except` TOP CHORD 4-6: 2x4 SP No.2, 1-3,7-9: 2x4 SP ND.1 BOT CHORD BOT CHORD 2x4 SP M 31 'Except' 12-14,10-12: 2x4 SP No.2 WEBS 2x4 SP No.3 WEDGE 'Left: 2x4 SP No.3, Right: 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 8=0-8-0 Max Horz 2=-294(LC 8) Max Uplift 2=-797(LC 10), 8=-797(LC 10) Max Grav 2=1540(LC 1), 8=1540(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-4919/3101, 3-4=-4613/2924, 4-5=-3036/2083, 5-6=-3036/2083, 6-7=-4613/2924, 7-8=-4919/3101 BOT CHORD 2-14=-2640/4556, 13-14=-1511/2821, 11-13=-1772/3223, 10-11=-1511/2821, 8-10=-2640/4445 WEBS 3-14=-371/397, 4-14=-1038/1926, 4-13=-1491535, 5-13=-399/275, 5-11=-399/275, 6-11=-149/535, 6-1 0=-1 038/1815, 7-10=-378/397 Scale=1:73.4 28 1.5x8 STP = 89' 5x8 PLATES GRIP MT20 244/190 MT20HS 187/143 Weight: 190 lb FT = 20% Structural wood sheathing directly applied. Rigid ceiling directly applied or 2-2-0 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 9-0-6, Exterior(2R) 9-0-6 to 16-11-10, Interior(1) 16-11-10 to 22-8-6, Extedor(2R) 22-8-6 to 30-7-10, Interior(1) 30-7-10 to 37-0-6, Extedor(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer/ Project engineer responsible forverifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. u) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Bearing at joint(s) 2, 8 considers parallel to grain value using ANSIfrPI 1 angle to grain formula. Building designer should verify a capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=797, 8=797. M 0 v 0 I� cG February 4,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing Mirek" Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the - - .. fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 123/5 WATERSTONE T22727471 2631413 A06 SPECIAL 1 1 Job Reference (optional) ommers nrsrauurce tndrn i ny, rLl, ridnt Uny, rL- aaooi, a r1-4-0, 5-11-1 11-0-0 17-04 1 4-05-0-15 6.0-0 4 5x6 = 6.00 12 6.4JU S NOV JU LULU mi I eK InauStrles, Inc. I nu FeD 4 1U:U4:11 2U21 I -age 1 ID:193QG WBBpX3jRl87ze0in7kz5?ad-19u Wzz?VhkdefbR17X037QKJTBj4adAnbj6YT3zoYg2 22-8-0 28-8-0 33-8-15 39-8-0 131-0-Q 5-8-0 6-0-0 5-0-15 5-11-1 1-4-D Scale = 1:72.0 2x4 11 24 25 5 5x6 = 6 26 27 5x6 = 7 29 - 1.5x8 STP = 5x8 S:: 3.01) F12 5x8 ZZ 16-10-11 22-9-5 LOADING (pso SPACING- 2-0-0 CS1. DEFL. in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.93 Vert(LL) 0.73 12-14 >656 240 MT20 244/190 TCDL 7.0 LumberDOL 1.25 BC 0.68 Vert(CT) -1.03 14-15 >464 180 MT20HS 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.56 Horz(CT) 0.58 9 n/a n/a BCDL 10.0 Code FBC2020/rP12014 Matrix-MSH Weight: 209 lb FT = 20 LUMBER- BRACING - TOP CHORD 2x4 SP No.1 'Except' TOP CHORD Structural wood sheathing directly applied. 4-6,6-7: 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 4-7-6 oc bracing. BOT CHORD 2x4 SP M 31 `Except` 13-15,11-13: 2x6 SP No.2 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3 , Right: 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=-253(LC 8) Max Uplift 2=-797(LC 10), 9=-797(LC 10) Max Grav 2=1540(LC 1), 9=1540(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-4917/3105, 3-4=-4608/2845, 4-5=-4142/2674, 5-6=-4142/2674, 6-7=-4145/2676, 7-8=-4608/2844, 8-9=-4916/3104 BOT CHORD 2-15=-2648/4483, 14-15=-1790/3279, 12-14=-2246/4158, 11-12=-1791/3281, 9-11=-2647/4442 WEBS 3-15=-333/3B5, 4-15=-745/1516, 4-14=-511/1116, 5-14=-321/300, 6-12=-381/301, 7-12=-511/1117, 7-11=-742/1461, 8-11=-342/385 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, 1nterior(1) 2-7-10 to 7-0-6, Extedor(2R) 7-0-6 to 14-11-10, 1nterior(1) 14-11-10 to 24-8-6, Exterior(2R) 24-8-6 to 32-7-10, Interior(1) 32-7-10 to 37-0-6, Exterior(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. v) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Bearing at joint(s) 2, 9 considers parallel to grain value using ANSI/rPI 1 angle to grain formula. Building designer should verify ■ capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=797.9=797. February 4,2021 A WARNING -Verily, design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE. USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify, the applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Welk' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP/f Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 123/5 WATERSTONE T22727472 2631413 A07 SPECIAL 1 1 Job Reference (optional) ouncers rtrsiSource (Plant city, rL), Plant L;tty, rL - 33b67, 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Feb 410:04:13 2021 Page 1 ID:193QG WBBpX3jR187zeOm7kz57ad-EYOHOf1 IDMtLvvbQEy2XCrPhK7SO2WB431 beYxzoYg0 ., r1-4-Oi 4-6-5 9-0-0 i 15-10-8 23-9-8 30-8-0 35-1-11 39-8-0 Al-O-Q '1�-0' 4-6-5 ' 4-5-11 6-10-8 7-10-15 6-10-8 4-5-11 4-6-5 1-4-0 6.00 F12 3x6 5x6 = 3x4 = 27 2829 5 5x8 = 5x6 = 3031 32 7 2x4 II 3x4 = 2x4 II 3.00 F12 8-8-0 35-1-11 3x6 Scale = 1:72.0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.78 Vert(LL) 0.21 15-16 >745 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.50 Vert(CT) 0.17 15-16 >942 180 BCLL 0.0 Rep Stress Incr NO WB 0.59 Horz(CT) 0.03 9 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-MSH Weight: 187 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-7-5 oc pudins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. All bearings 0-8-0 except Qt=length) 16=0-4-0, 13=0-4-0. (lb) - Max Horz 2=212(LC 9) Max Uplift All uplift 100 lb or less at joint(s) except 2=-288(LC 10), 9=-302(LC 10), 16=-686(LC 10), 13=-715(LC 10) Max Grav All reactions 250 lb or less at joints) except 2=451(LC 15), 9=527(LC 16), 16=1125(LC 19), 13=1185(LC 20) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-947/494, 3-4=-338/135, 4-5=-325/669, 5-6=-58/715, 6-7=-348/707, 7-8=-471/221, 8-9=-1083/570 BOT CHORD 2-18=-291/979, 17-18=-295/986, 16-17=-23/293, 15-16=-328/181, 13-15=-426/296, 12-13=0/332, 11-12=-365/945, 9-11=-359/937 WEBS 3-17=-599/468, 4-17=-51/419, 4-16=-986/630, 5-16=-792/685, 5-15=-520/206, 6-15=-489/297, 7-12=-72/391, 8-12=-588/458, 6-13=-773/671, 7-13=-997/703 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf,, h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) A-4-0 to 2-7-10, Intedor(1) 2-7-10 to 5-0-6, Exterior(21R) 5-0-6 to 12-11-10, Interior(1) 12-11-10 to 26-8-6, Exterior(2R) 26-8-6 to 34-7-10, Interior(1) 34-7-10 to 37-0-6, Exterior(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Bearing at joint(s) 2, 9 considers parallel to grain value using ANSI[TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 288 lb uplift at joint 2, 302 lb uplift, at joint 9, 686 lb uplift at joint 16 and 715 lb uplift at joint 13. Q) Load case(s) 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 15, 16, 17, 18 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard Except: continued on page 2 February 4,2021 A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5119/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not• a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MO 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 123/5 WATERSTONE T22727472 2631413 A07 SPECIAL 1 1 Jab Reference (optional) tsullaers mrsi6ource trlant uty, t-Lj, mans city, I-L - 33btif, 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Feb 4 10:04:13 2021 Page 2 ID:193QG WBBpX3jR187zeOm7kz5?ad-EYOHOf11DMtLvvbQEy2XCrPhK?SO2 W B431 beYxzoYgO LOAD CASE(S) Standard Except: 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-54, 4-7=-54, 7-10=-54, 17-19=-20, 12-17=-20, 12-22=-20 4) Dead + 0.6 C-C Wind (Pos. Internal) Case 1: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=105, 2-25=59, 25-26=47, 4-26=70, 4-28=70, 28-31=47, 7-31=70, 7-33=70, 33-34=47, 9-34=59, 9-10=105, 17-19=-10, 16-17=-10, 13-16=20(F=30), 12-13=-10, 12-22=-10 Horz: 1-2=-113, 2-25=-67, 25-26=-56, 4-26=-78, 7-33=78, 33-34=56, 9-34=67, 9-10=113 5) Dead + 0.6 C-C Wind (Neg. Internal) Case 1: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=3, 2-4=-41, 4-7=-41, 7-9=-41, 9-10=3, 17-19=-20, 16-17=-20, 13-16=1O(F=30), 12-13=-20, 12-22=-20 Horz: 1-2=-17, 2-4=27, 7-9=-27, 9-10=17 6) Dead +0.6 MWFRS Wind (Pos. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=42, 2-4=13, 4-29=45, 29-32=26, 7-32=16, 7-9=31, 9-10=21, 17-19=-10, 16-17=-10, 13-16=20(F=30), 12-13=-10, 12-22=-10 Horz: 1-2=-50, 2-4=-22, 7-9=39, 9-10=29 7) Dead + 0.6 MWFRS Wind (Pos. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=21, 2-4=31, 4-27=16, 27-30=26, 7-30=45, 7-9=13, 9-10=42, 17-19=-10, 16-17=-10, 13-16=20(F=30), 12-13=-10, 12-22=-10 Horz: 1-2=-29, 2-4=-39, 7-9=22, 9-10=50 8) Dead +0.6 MWFRS Wind (Neg. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-26, 2-4=-36, 4-7=-16, 7-9=5, 9-10=15, 17-19=-20, 16-17=-20, 13-16=10(F=30), 12-13=-20, 12-22=-20 Horz: 1-2=12, 2-4=22, 7-9=19, 9-10=29 9) Dead + 0.6 MWFRS Wind (Neg. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=15, 2-4=5, 4-7=-16, 7-9=-36, 9-10=-26, 17-19=-20, 16-17=-20, 13-16=10(F=30), 12-13=-20, 12-22=-20 Horz: 1-2=-29, 2-4=-19, 7-9=-22, 9-10=-12 10) Dead +0.6 MWFRS Wind (Pos. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=74, 2-4=45, 4-7=45, 7-9=45, 9-10=74, 17-19=-10, 16-17=-10, 13-16=20(F=30), 12-13=-10, 12-22=-10 Horz: 1-2=-82, 2-4=-54, 7-9=54, 9-10=82 11) Dead + 0.6 MWFRS Wind (Pos. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=45, 2-4=16, 4-7=16, 7-9=16, 9-10=45, 17-19=-10, 16-17=-10, 13-16=20(F=30), 12-13=-10, 12-22=-10 Horz: 1-2=-53, 2-4=-25, 7-9=25, 9-10=53 12) Dead + 0.6 MWFRS Wind (Neg. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-5, 2-4=-16, 4-7=-16, 7-9=-16, 9-10=-5, 17-19=-20, 16-17=-20, 13-16=10(F=30), 12-13=-20, 12-22=-20 Horz: 1-2=-9, 2-4=2, 7-9=-2, 9-10=9 13) Dead + 0.6 MWFRS Wind (Neg. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-5, 2-4=-16, 4-7=-16, 7-9=-16, 9-10=-5, 17-19=-20, 16-17=-20, 13-16=10(F=30), 12-13=-20, 12-22=-20 Horz: 1-2=-g, 2-4=2, 7-9=-2, 9-10=9 15) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Left): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-53, 2-4=-61, 4-7=-45, 7-9=-30, 9-10=-22, 17-19=-20, 16-17=-20, 13-16=61(F=81), 12-13=-20, 12-22=-20 Horz: 1-2=9, 2-4=17, 7-9=14, 9-10=22 16) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Right): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-22, 2-4=-30, 4-7=-45, 7-9=-61, 9-10=-53, 17-19=-20, 16-17=-20, 13-16=61(F=81), 12-13=-20, 12-22=-20 Horz: 1-2=-22, 2-4=-14, 7-9=-17, 9-10=-9 17) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 1 st Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-37, 2-4=-45, 4-7=-45, 7-9=-45, 9-10=-37, 17-19=-20, 16-17=-20, 13-16=61(F=81), 12-13=-20, 12-22=-20 Horz: 1-2=-7, 2-4=1, 7-9=-1, 9-10=7 18) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 2nd Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-37, 2-4=-45, 4-7=-45, 7-9=-45, 9-10=-37, 17-19=-20, 16-17=-20, 13-16=61(F=81), 12-13=-20, 12-22=-20 Horz: 1-2=-7, 2-4=1, 7-9=-1, 9-10=7 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 611g/2020 BEFORE USE. �'' Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/1"Pl1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Type City Ply LOT 12315 WATERSTONE TAOss T22727473 2631413 SPECIAL 1 1 Job Reference o tional tiunders I-irstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Feb 410:04:14 2021 Page 1 ID:193QGWBBpX3jR187zeOm7kz5?ad-ikafc?1 Nzf?CW3Acofzmk2ysMPiOntoEIhKC40zoYg? ., r1 4-0, 7-0-0 12-3-1 16-0-8 19-10-0 22-5-14 26-3-5 32-8-0 39-8-0 s11-0-Q 1-4-0 7-0-0 5-3 3-9-8 2-7-14 3-9-8 6-4-11 7-0-0 6.00 12 5x6 = 3x8 = 3x4 = 3 24 25 4 2627 28 5 29 3x6 :::� 3.00 FIT 2x4 II 5x6 = 5x12 = 5x6 = 30 6 31 7 32 833 34 35 9 3x8 = Scale = 1:72.0 c+� N 1.5x8 STP = 0 11 0 3x6 ZZ L 7-1-8 U-3-1 12r8-0 19-10-0 26-2-0 26�3-5 32-6-8 39-8-0 ' 7-1-8 5 7-4-0 6-4-0 0- -5 6-3-3 7-1-8 , Plate Offsets (X,Y)— [2:0-0-10,Edge], [3:0-3-0,0-2-0], [4:0-3-8,0-1-8], [7:0-3-0,0-3-0], [8:0-3-8,0-2-8], [9:0-4-0,0-2-8], [10:0-0-10,Edge], [12:0-8-0,0-0-8], [13:0-3-8,0-3-0], 1`16:0-3-8,0-3-01,r17:0-5-4,0-0-81 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.83 Vert(LL) 0.24 14-16 >696 240 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.90 Vert(CT) -0.27 14-16 >630 180 BCLL 0.0 Rep Stress Incr NO WB 0.95 Horz(CT) 0.06 10 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-MSH Weight: 177 lb FT = 20 LUMBER- BRACING - TOP CHORD 2x4 SP No.2 'Except' TOP CHORD Structural wood sheathing directly applied or 3-10-9 oc pudins. 7-9: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 5-5-4 oc bracing. BOT CHORD 2x4 SP No.2 WEBS 1 Row at midpt 8-12 WEBS 2x4 SP No.3 REACTIONS. All bearings 0-8-0 except Gt=length) 16=0-4-0, 13=0-4-0. (lb) - Max Horz 2=-171(LC 6) Max Uplift All uplift 100 lb or less at joint(s) except 2=-356(LC 8), 10=-429(LC 8), 16=-1695(LC 8), 13=-1859(LC 8) Max Grav All reactions 250 lb or less at joints) except 2=612(LC 1), 10=697(LC 1), 16=2263(LC 1), 13=2397(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1245/434, 3-4=-1038/444, 4-5=-573/923, 5-6=-856/1302, 6-7=-856/1302, 7-8=-866/1022, 8-9=-1360/708, 9-10=-1598/729 BOTCHORD 2-17=-263/1089, 16-17=-923/751, 14-16=-529/321, 13-14=-435/248, 12-13=-1022/891, 10-12=-507/1412 WEBS 3-17=-102/288, 4-16=-1311/939, 5-16=-1398/1438, 5-14=-602/680, 6-14=-421/437, 7-14=-775/753, 7-13=-1427/1490, 8-13=-1441/1137, 9-12=-14/366, 4-17=-1017/2098, 8-12=-1419/2494 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load, shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 2, 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 356 lb uplift at joint 2, 429 lb uplift;at • joint 10, 1695 lb uplift at joint 16 and 1859 lb uplift at joint 13. 9) Load case(s) 4, 5, 6, 7, 8, 9, 10, 11, 13, 14, 15, 16 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. February 4,2021 continued on page 2 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE.' Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek" is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP/t Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Saletyinformadon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 12315 WATERSTONE T22727473 2631413 A08 SPECIAL 1 1 Job Reference o tional tdunaers t-Irst source lviant ldty, hL), Flan L:Ity, i-L-33bb7, 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Feb 4 10:04:14 2021 Page 2 ID:193QGWBBpX3jR187zeOm7kz5?ad-ikafc?1 Nzf?CW3AcofZmk2ysMPiOntoElhKC40zoYg? NOTES- 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 175 lb down and 159 lb up at 7-0-0, 111 lb down and 197 lb up at 9-0-12, 111 lb down and 197 lb up at 11-0-12, 111 lb down and 197 lb up at 13-0-12, 111 lb down and 197 lb up at 15-0-12, 111 lb down and 197 lb up at 17-0-12, 111 lb down and 197 lb up at 19-0-12, 111 lb down and 197 lb up at 20-7-4, 111 lb down and 197 lb up at 22-7-4, 111 lb down�and 197 lb up at 24-7-4, 111 lb down and 197 lb up at 26-7-4, 111 lb down and 197 lb up at 28-7-4, and 111 lb down and 197 lb up at 30-7-4, and 175 lb down and 356 (b up at 32-8-0 on top chord, and 353 lb down and 128 lb up at 7-1-8, 92 lb down at 9-0-12, 92 lb down at 11-0-12, 92 lb down at 13-0-12, 92 lb down at 15-0-12, 92 lb down at 17-0-12, 92 lb down at 19-0-12, 92 lb down at 20-7-4, 92 lb down at 22-7-4, 92 lb down at 24-7-4, 92 lb down at 26-7-4, 92 lb down at 28-7-4, and 92 lb down at 30-7-4, and 353 lb down and 128 lb up at 32-6-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-9=-54, 9-11=-54, 17-18=-20, 12-17=-20, 12-21=-20 Concentrated Loads (lb) Vert: 3=-175(B) 7=-111(B) 9=-175(B) 17=-330(B) 15=46(13) 12=-330(B) 24=-111(B) 25=-111(B) 26=-111(B) 28=-111,(B) 29=-111(B) 30=-111(B) 31=-111(B) 32=-111(B)33=-111(13)34=-111(B)35=-111(B)36=46(B)37=-46(B)38=46(B)39=46(B)40=-46(B)41=46(B)42=46(B)43=-46(B)44=-46(B)45=-46(B) 46=-46(B) 4) Dead + 0.6 MWFRS Wind (Pos. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=42, 2-3=13, 3-27=45, 27-34=26, 9-34=16, 9-10=31, 10-11=21, 17-18=-10, 16-17=-10, 13-16=49(F=59), 12-13=-10, 12-21=-10 Horz: 1-2=-50, 2-3=-22, 9-10=39, 10-11=29 Concentrated Loads (lb) Vert: 3=130(B) 7=156(B) 9=257(B) 17=108(B) 15=-23(B) 12=108(B) 24=136(B) 25=136(B) 26=136(B) 28=156(B) 29=156(B) 30=156(B) 31=156(B) 32=156(B) 33=156(B) 34=156(B) 35=165(B) 36=-23(B) 37=-23(B) 38=-23(B) 39=-23(B) 40=-23(B) 41=-23(B) 42=-23(B) 43=-23(B) 44=-23(B) 45=-23(B) 46=-23(B) 5) Dead + 0.6 MWFRS Wind (Pos. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=21, 2-3=31, 3-25=16, 8-25=26, 8-9=45, 9-10=13, 10-11=42, 17-18=-10, 16-17=-10, 13-16=49(F=59), 12-13=-10, 12-21=-10 Horz: 1-2=-29, 2-3=-39, 9-10=22, 10-11=50 Concentrated Loads (Ib) Vert: 3=1 59(B) 7=1 56(B) 9=246(B) 17=1 08(B) 15=-23(B) 12=1 08(B) 24=1 65(B) 25=1 56(B) 26=1 56(B) 28=1 56(B) 29=1 56(B) 30=1 56(B) 31 =1 56(B) 32=1 56(B) 33=1 36(B) 34=1 36(B) 35=1 36(B) 36=-23(B) 37=-23(B) 38=-23(B) 39=-23(B) 40=-23(B) 41 =-23(B) 42=-23(B) 43=-23(B) 44=-23(B) 45=-23(B) 46=-23(B) 6) Dead + 0.6 MWFRS Wind (Neg. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-26, 2-3=-36, 3-9=-16, 9-10=5, 10-1 1=15,17-18=-20, 16-17=-20, 13-16=39(F=59), 12-13=-20, 12-21=-20 Horz: 1-2=12, 2-3=22, 9-10=19, 10-11=29 Concentrated Loads (lb) Vert: 3=54(B) 7=197(B) 9=315(B) 17=128(B) 15=-13(B) 12=128(B) 24=197(B) 25=197(B) 26=197(B) 28=197(B) 29=iW(B) 30=197(B) 31=197(B) 32=197(B) 33=197(B) 34=197(B) 35=197(B) 36=-13(B) 37=-13(B) 38=-13(B) 39=-13(B) 40=-13(B) 41=-13(B) 42=-13(B) 43=-13(B) 44=-13(B) 45=-13(B) 46=-13(B) 7) Dead + 0.6 MWFRS Wind (Neg. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=15, 2-3=5, 3-9=-16, 9-10=-36, 10-11=-26, 17-18=-20, 16-17=-20, 13-16=39(F=59), 12-13=-20, 12-21=-20 Horz: 1-2=-29, 2-3=-19, 9-10=-22, 10-11=-12 Concentrated Loads (lb) Vert: 3=54(B) 7=197(B) 9=356(B) 17=128(B) 15=-13(B) 12=128(B) 24=197(B) 25=197(B) 26=197(B) 28=197(B) 29=197(B) 30=197(B) 31=197(B) 32=197(B) 33=197(B) 34=197(B) 35=197(B) 36=-13(B) 37=-13(B) 38=-13(B) 39=-13(B) 40=-13(B) 41=-13(B) 42=-13(B) 43=-13(B) 44=-13(B) 45=-13(B) 46=-13(B) 8) Dead + 0.6 MWFRS Wind (Pos. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=74, 2-3=45, 3-9=45, 9-10=45, 10-11=74, 17-18=-10, 16-17=-10, 13-16=49(F=59), 12-13=-10, 12-21=-10 Horz: 1-2=-82, 2-3=-54, 9-10=54, 10-11=82 Concentrated Loads (lb) Vert: 3=130(B)7=136(B)9=214(B)17=108(B)15=-23(B)12=108(B)24=136(B)25=136(B)26=136(B)28=136(B)29=136(B) 30=136(B)31=136(B)32=136(B)33=136(B)34=136(B)35=136(B)36=-23(B)37=-23(B)38=-23(B)39=-23(B)40=-23(B) 41=-23(B) 42=-23(B) 43=-23(B) 44=-23(B) 45=-23(B) 46=-23(B) 9) Dead + 0.6'MWFRS Wind (Pos. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=45, 2-3=16, 3-9=16, 9-10=16, 10-11=45, 17-18=-10, 16-17=-10, 13-16=49(F=59), 12-13=-10, 12-21=-10 Horz: 1-2=-53, 2-3=-25, 9-10=25, 10-11=53 Concentrated Loads (lb) Vert: 3=116(B)7=165(B)9=271(B)17=108(B)15=-23(B)12=108(B)24=165(B)25=165(B)26=165(B)28=165(B)29=165(B) 30=165(B)31=165(B)32=165(13)33=165(B)34=165(B)35=165(13)36=-23(B)37=-23(B)38=-23(B)39=-23(B)40=-23(B) 41=-23(B) 42=-23(B) 43=-23(B) 44=-23(B) 45=-23(B) 46=-23(B) 10) Dead + 0.6 MWFRS Wind (Neg. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-5, 2-3=-16, 3-9=-16, 9-10=-16, 10-11=-5, 17-18=-20, 16-17=-20, 13-16=39(F=59), 12-13=-20, 12-21=-20 Horz: 1-2=-9, 2-3=2, 9-10=-2, 10-11=9 Concentrated Loads (lb) Vert: 3=72(B) 7=197(B) 9=335(B) 17=128(B) 15=-13(B) 12=128(B) 24=197(B) 25=197(B) 26=197(B) 28=197(B) 29=197(B) 30=197(B)31=197(B)32=197(B)33=197(B)34=197(B)35=197(B)36=-13(13)37=-13(B)38=-13(B)39=-13(B)40=-13(B) 41=-13(B) 42=-13(B) 43=-13(B) 44=-13(B) 45=-13(B) 46=-13(B) 11) Dead + 0.6 MWFRS Wind (Neg. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-5, 2-3=-16, 3-9=-16, 9-10=-16, 10-11=-5, 17-18=-20, 16-17=-20, 13-16=39(F=59), 12-13=-20, 12-21=-20, Horz: 1-2=-9, 2-3=2, 9-10=-2, 10-11=9 Continued on page 3 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDEb MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M iTelCs is always required for stability and to prevent collapse with possible personal Injury and property, damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPI1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa; FL 36610 Job Truss Truss Type Qty Ply LOT 123/5 WATERSTONE T22727473 2631413 A08 SPECIAL 1 1 Job Reference o tional tswlaers mr-stbource (runt uny, ra), Nlant aty, FL - 3356f, 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Feb 410:04:14 2021 Page 3 ID:193QGWBBpX3jR187zeOm7kz5?ad-ikafc?1 Nzf?CW3AcofZmk2ysMPiOntoElhKC40zoYg? LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 3=72(B) 7=1 97(B) 9=335(B) 17=1 28(B) 15=-1 3(B) 12=1 28(B) 24=1 97(B) 25=1 97(B) 26=1 97(B) 28=1 97(B) 29=1 97(B) 30=1 97(B) 31 =1 97(B) 32=1 97(B) 33=197(B) 34=197(B) 35=197(B) 36=-13(B) 37=-13(B) 38=-13(B) 39=-13(B) 40=-13(B) 41=-13(B) 42=-13(B) 43=-13(B) 44=-13(B) 45=-13(B) 46=-13(B) 13) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Left): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-53, 2-3=-61, 3-9=-45, 9-10=-30, 10-11=-22, 17-18=-20, 16-17=-20, 13-16=24(F=44), 12-13=-20, 12-21=-20 Horz: 1-2=9, 2-3=17, 9-10=14, 10-11=22 Concentrated Loads (lb) Vert: 3=-19(B) 7=145(B) 9=232(B)17=76(B)15=-13(B)12=76(B)24=145(B)25=145(B)26=145(B)28=145(B)29=145(B)30=145(B)31=145(B)32=145(B) 33=145(B) 34=145(B) 35=145(B) 36=-13(B) 37=-13(B) 38=-13(B) 39=-13(B) 40=-13(B) 41=-13(B) 42=-13(B) 43=-13(B) 44=-13(B) 45=-13(B) 46=-13(B) 14) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Right): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plo Vert: 1-2=-22, 2-3=-30, 3-9=-45, 9-10=-61, 10-11=-53, 17-18=-20, 16-17=-20, 13-16=24(F=44), 12-13=-20, 12-21=-20 Horz: 1-2=-22, 2-3=-14, 9-10=-17, 10-11=-9 Concentrated Loads (lb) Vert: 3=-19(B)7=145(B)9=262(B)17=76(B)15=-13(B)12=76(B)24=145(B)25=145(B)26=145(B)28=145(B)29=145(B)30=145(B)31=145(B)32=145(B) 33=145(B) 34=145(B) 35=145(B) 36=-13(B),37=-13(B) 38=-13(B) 39=-13(B) 40=-13(B) 41=-13(B) 42=-13(B) 43=-13(B) 44=-13(B) 45=-13(B) 46=-13(B) 15) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 1 st Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-37, 2-3=-45, 3-9=-45, 9-10=-45, 10-11=-37, 17-18=-20, 16-17=-20, 13-16=24(F=44), 12-13=-20, 12-21=-20 Horz: 1-2=-7, 2-3=1, 9-10=-1, 10-11=7 Concentrated Loads (lb) Vert: 3=-5(B) 7=1 45(B) 9=247(B) 17=76(B) 15=-1 3(B) 12=76(B) 24=1 45(B) 25=1 45(B) 26=1 45(B) 28=1 45(B) 29=1 45(B) 30=1 45(B) 31 =1 45(B) 32=1 45(B) 33=145(B) 34=145(B) 35=145(B) 36=-13(B) 37=-13(B) 38=-13(B) 39=-13(B) 40=-13(B) 41=-13(13) 42=,13(B) 43=-13(B) 44=-13(B) 45=-13(B) 46=-13(B) 16) Dead + 0.75 Roof Live (bat.) + 0.75(0.6 MWFRS Wind (Neg. Int) 2nd Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-37, 2-3=-45, 3-9=-45, 9-10=-45, 10-1 1=-37,17-18=-20, 16-17=-20, 13-16=24(F=44), 12-13=-20, 12-21=-20 Horz: 1-2=-7, 2-3=1, 9-10=-1, 10-11=7 Concentrated Loads (lb) Vert: 3=-5(B) 7=1 45(B) 9=247(B) 17=76(B) 15=-1 3(B) 12=76(B) 24=1 45(B) 25=1 45(B) 26=1 45(B) 28=1 45(B) 29=1 45(B) 30=1 45(B) 31 =1 45(B) 32=1 45(B) 33=145(B) 34=145(B) 35=145(B) 36=-13(B) 37=-13(B) 38=-13(B) 39=-13(B) 40=-13(B) 41=-13(B) 42=-13(B) 43=-13(B) 44=-13(B) 45=-13(13) 46=-13(B) ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an individual building component, not '��• a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing iVliTek" is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPli Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MO 20601 Tampa, FL 36610 Job Truss Truss Type City Ply LOT'123/5 WATERSTONE T22727474 2631413 A09 SPECIAL 1 1 Job Reference c tional Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Feb 4 10:04:16 2021 Page 1 ID:193QG W BBpX3jR187zeOm7kz5?ad-f6iPOh3eVHGwmNK_w4bEgT1 AuCMEFpZWI?pJ8GroYfz 1-4-0 6-8-0 13-0-0 19-10-0 1-0 23-10-0 26-8-0 33-0-01-0- 1-4-0 6-B-0 .6-4-0 6-10-0 -2-0 2-10-0 2-10-0 6-4-0 6-8-0 Scale = 1:75.5 ^ - r.__ 5x8 = 5x6 i 3x6 = 6x12 MT20HS 1 5xB 3.00 12 5x8 8-B-0 15-7-5 24-0-11 31-0=0 39-8-0 8-8-0 6-11-5 8-5-6 6-11-5 8-8-0 Plate Offsets (X,Y)-- [2:0-2-7,Edge], [3:0-3-0,0-3-0], [4:0-5-0,0-2-0], [7:0-3-0,Edge], [9:0-3-0,0-3-0], [10:0-2-7,Edge] LOADING (pso SPACING- 2-0-0 CSI. DEFL. in (loc) I/defli Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.95 Vert(LL) 0.63 12-13 >757 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.94 Vert(CT) -0.96 13-15 >497 180 MT20HS 187/143 BCLL 0.0 Rep Stress ]net YES WB 0.81 Horz(CT) 0.60 10 n/a n/a BCDL 10.0 Code FBC2020ITP12014 Matrix-MSH Weight: 199 lb FT = 20 LUMBER- BRACING - TOP CHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied. Except: 3-4,8-9: 2x4 SP M 31, 1-3,9-11: 2x4 SP No.1 1 Row at midpt 6-8 BOT CHORD 2x4 SP M 31 *Except* BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. 14-16,12-14: 2x4 SP No.2 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 10=0-8-0 Max Horz 2=-351(LC 8) Max Uplift 2=-797(LC 10), 10=-797(LC 10) Max Grav 2=1540(LC 1), 10=1540(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-4917/3040, 3-4=-4613/2864, 4-5=-3032/2004, 5-6=-3037/1932, 6-8=-2899/1832, 8-9=-4664/2728, 9-10=-4929/2866 BOT CHORD 2-16=-2647/4620, 15-16=-1516/2827, 13-15=-1718/3209, 12-13=-1412/2856, 10-12=-2425/4456 WEBS 3-16=-368/396, 4-16=-104111945, 4-15=-103/484, 5-15=-339/221, 5-13=-415/327, 8-13=-186/531, 8-12=-942/1816, 9-12=-298/322 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 9-0-6, Exterior(21R) 9-0-6 to 16-11-10, Interior(1) 16-11-10 to 21-0-7, Exterior(2R) 21-0-7 to 23-10-0, Extedor(2E) 23-10-0 to 26-4-1, Interior(1) 26-4-1 to 37-0-6, Extedor(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. -8) Bearing atjoint(s) 2, 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 797 lb uplift at joint 2 and 797 lb uplift at joint 10. 10) Graphical puriin representation does not depict the size or the orientation of the puriin along the top and/or bottom chord. February 4,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTpik* is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Qty Ply LOT 123/5 WATERSTONE Trusse T22727475 2631413 A10 1 1 Job Reference o tional tsunaers t-irstsource (Fiant city, t-t_), Fiant uty, FL - 33b6/, 13.43u s NOV.3U 2u2u MI I eK Inaustnes, Inc. I nu t-eD 4 1u:1.14:16 tun I -age 1 ID:193QG W BBpX3jRI87zeOm7kz5?ad-bVgARN4u 1 u We?gTN1 Vejvu6VeO6tjnspCJ IPC9zoYfx rt 4-0 5-11-1 11-0-0 16-11-1 19-0-0 , 22-9-15 23-t0i0 28-8-0 33-8-15 39-8-1 1-4-0 5-11-1 5-0-15 5-10-] 2-1-15 3-9-15 -0- 4-10-15 5-11-1 Scale = 1:75.5 5x6 = 6x12 MT20HS 8 31 5x6 = 2x4 I 5x6 i 4 5 30 7 10 6.00 12 27 28 6 2x4 26 2x4 I 2x4 M 3 11 1.5x8 STP = `° 1.5x8 STP = 25 29 0 2 18 17 16 15 14 12IQ 0 1 8xl4 MT20HS = 5x8 = 5x8 — 4x6 = 8x14 MT20HS = 11 5x8 % 3.00 FIT 5x8 8-8-0 16-10-11 22-9-5 i 31-0-0 39-8-0 8-8-0 8-2-11 5-10-11 8-2-11 8-8-0 Plate Offsets (X Y)-- 12:0-2-7 Edge] [4:0-3-8 0-2-4] [7:0-3-0,0-3-0] [12:0-2-7,Edge], [14:0-7-0 0-3-91, [18:0-7-0,0-3-9] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 1.00 Vert(LL) 0.68 15-17 >704 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.67 Vert(CT) -0.95 17 >499 180 MT20HS 1871143 BCLL 0.0 Rep Stress Incr YES WB 0.56 Horz(CT) 0.55 12 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-MSH Weight: 228 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. 1-4,10-13: 2x4 SP M 31 Except: BOT CHORD 2x4 SP M 31 *Except* 1 Row at midpt 6-7, 7-10 16-18,14-16: 2x6 SP No.2 BOT CHORD Rigid ceiling directly applied or 4-6-1 oc bracing. WEBS 2x4 SP No.3 JOINTS 1 Brace at Jt(s): 7 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 12=0-8-0 Max Horz 2=-351(LC 8) Max Uplift 2=-797(LC 10), 12=-797(LC 10) Max Grav 2=1540(LC 1), 12=1540(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-4912/3208, 3-4=-4607/2953, 4-5=-4155/2803, 5-6=-4155/2803, 6-7=-3887/2655, 7-9=-3697/2494, 9-10=-3697/2494, 10-11=-4713/2868, 11-12=-4921/3021, 6-8=-336/262, 8-10=-359/270 BOT CHORD 2-18=-2784/4606, 17-18=-1907/3299, 15-17=-2254/3973, 14-15=-1844/3338, 12-14=-2569/4446 WEBS 3-18=-326/377, 4-18=-785/1550, 4-17=-577/1023, 5-17=-457/439, 7-17=-172/405, 7-15=-293/294, 10-15=-471/888, 10-14=-703/1474, 11-14=-229/273 NOTES- 1) Unbalanced roof live loads have been.considered forthis design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 7-0-6, Exterior(2R) 7-0-6 to 14-11-10, Interior(1) 14-11-10 to 19-10-6, Exterior(2R) 19-10-6 to 27-9-10, Interior(1) 27-9-10 to 37-0-6, Exterior(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 18) Bearing at joint(s) 2, 12 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 797 lb uplift at joint 2 and 797 lb uplift at joint 12. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. February 4,2021 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M114473 rev. 5/1012020 BEFORE USE. Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MITPrk• is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 123/5 WATERSTONE T22727476 2631413 All SPECIAL 1 1 Job Reference fto tional Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Feb 4 10:04:19 2021 Page 1 ID:3xt7Yd6RbYnXO16Sf6ghjjz4cnz-3hNYfj5WoCeVdg2ZbC9yR6fgxQP4S9JzRz2zkbzoYfw r1 4 0 7-0-0 23-10-0 31-6-0 380 Ill 6-0 200 3-1 3-8-8 7-8-0 820 3x6 % 3.00 12 Scale = 1:73.7 5x6 = 14 13 - 46 = 3x6 = 3x6 = 6x8 = 29-6-4 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) 1/defi L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.97 Vert(LL) -0.26 11-13 >887 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0:86 Vert(CT) -0.40 11-13 >582 180 BCLL 0.0 Rep Stress Incr YES WB 0.87 Horz(CT) -0.02 13 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-MSH Weight: 198 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied. BOT CHORD 2x4 SP No.2 *Except* BOT CHORD Rigid ceiling directly applied or 5-2-0 oc bracing. Except: 6-13: 2x4 SP No.3, 9-12: 2x4 SP No.1 3-4-0 oc bracing: 13-15 WEBS 2x4 SP No.3 WEBS 1 Row at midpt 7-13 REACTIONS. (size) 2=0-8-0, 13=0-4-0, 9=0-8-0 Max Horz 2=351(LC 9) Max Uplift 2=-495(LC 10), 13=-614(LC 10), 9=-482(LC 10) Max Grav 2=911(LC 15), 13=1807(LC 15), 9=1002(LC 16) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP'CHORD 2-3=-2386/1504, 3-4=-2061/1313, 4-5=-1309/930, 5-6=-245/302, 6-7=-205/413, 7-8=-1244/782, 8-9=-1366/742 BOT CHORD 2-17=-1231/2415, 16-17=-854/1893, 15-16=-473/773, 13-15=-1016/719, 11-13=0/251, 9-11=-454/1151 WEBS 3-17=-327/308, 4-17=-352/913, 4-16=-530/308, 5-16=-141/814, 5-15=-1061/824, 7-13=-688/240, 7-11=-466/1148, 8-11=-537/503 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 5-0-6,'Exterior(2R) 5-0-6 to 12-11-10, Interior(1) 12-11-10 to 19-10-6, Extedor(2R) 19-10-6 to 27-9-10, Interior(1) 27-9-10 to 37-0-6, Extedor(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 7 Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 495 lb uplift at joint 2, 614 lb uplift at joint 13 and 482 lb uplift at joint 9. February 4,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. ' Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing iVliTek` is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPIf Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply LOT 12315 WATERSTONE T22727477 2631413 Al2 SPECIAL 1 1 Job Reference (optional) ounuers rr3WUurue train l ny, rLl, rianl Idly, rL - JJOo/, 0.4JU S Nov JU ZUZU MI I eK InUUSIrIeS, Inc. I nu reD 4 IU:U4:ZZ ZUZI rage I I D:3xt?Yd6 RbYnXO16Sf6ghjjz4cnz-TG3g Hk805704 U In 8GLif3kH FtdQVfZhP7xG d LwzoYft .. r1-4-0, 7-0-0 9-2-2 12-8-0 , 15-0-0 ,17-1-13 20-1-3 22-4-0 25-4-0 31-0-2 35-4-2 39.8-0 1-4-0 7-0-0 2-2-2 3-5-14 2-4-0 2-1-13 2-11-11 2-2-8 3-0-0 5-8-2 4-3-15 4-3-14 3x8 1 5x6 :::- 3.00 FIT 8xl2 = 7-1-8 , 9-10-0 3x4 I 8 5x6 = 5x8 = 9 10 Scale = 1:73.4 20 1.5x6 STP = 7V/ ��ZZ I I 13lol 14 Iv 9 18 17 16 15 c 19 3x6 = 3x6 = 3x6 = 6x12 MT20HS = 3x4 = LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr NO Code FBC2020/TPI2014 CSI. TC 0.73 BC 0.88 WB 0.70 Matrix-MSH DEFL. Vert(LL) Vert(CT) Horz(CT) in (cc) I/deft Lid 0.25 24 >981 240 -0.33 24 >751 180 -0.03 18 n/a n/a PLATES MT20 MT20HS Weight: 237lb GRIP 2441190 187/143 FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-6-6 cc purlins. BOT CHORD 2x4 SP No.2 *Except* BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing, Except: 5-23: 2x8 SP 240OF 2.OE, 20-22: 2x6 SP M 26, 8-18: 2x4 SP M 31 4-10-8 cc bracing: 2-25 WEBS 2x4 SP No.3 5-0-4 cc bracing: 24-25 WEDGE 6-5-10 cc bracing: 23-24. Left: 2x4 SP No.3 5-10-0 cc bracing: 18-20 WEBS 1 Row at midpl 10-18 REACTIONS. (size) 2=0-8-0, 18=0-4-0, 13=0-8-0 Max Horz 2=321(LC 7) Max Uplift 2=-691(LC 8), 18=-932(LC 8), 13=-406(LC 8) Max Grav 2=1187(LC 1), 18=2161(LC 1), 13=787(LC 14) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3450/1751, 3-4=-3077/1697, 4-5=-2993/1733, 5-6=-3360/1924, 6-7=-1098/877, 7-8=-223/736, 8-9=-192/586, 9-10=-137/471, 10-11=-422/262, 11-12=-1076/465, 12-13=-1222/516 BOT CHORD 2-25=-1429/3117, 24-25=-1405/3091, 23-24=-847/1665, 21-22=-938/1657, 18-20=-1196/748, 8-20=-307/255, 15-17=-164/714, 13-15=-336/1048 WEBS 3-25=-424/1159, 3-24=-321/23, 4-24=-176/251, 22-24=-632/1451, 6-22=-801/1838, 6-21=-1505/917, 7-21=-797/1542, 7-20=-1074/642, 9-18=-290/80, 10-18=-901/343, 10-1 7=-1 88/531, 11-17=-616/383, 11-15=-64/397 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. '9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 691 lb uplift at joint 2, 932 lb uplift, at joint 18 and 406 lb uplift at joint 13. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 179 lb down and 164 lb up at 7-0-0, and 115 lb down and 182 lb up at 9-0-12, and 115 lb down and 182 lb up at 11-0-12 on top chord, and 343 lb down and 129 lb up at 7-1-8, arid 81 lb down at 9-0-12, and 81 lb down at 11-0-12 on bottom chord. The design/selection of such connection :ontftfddeAR)0aQWresponsibility of others. February 4,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5119/2020 BEFORE USE. Design valid for use onlywith MITek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI77Pl1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Informal/on available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 123/5 WATERSTONE T22727477 2631413 Al2 SPECIAL 1 1 Job Reference (optional) uullaers mrstbource (Plant uty, t-L), Nlant c;lty, t-L - 33bbf, 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Feb 4 10:04:22 2021 Page 2 ID:3xt7Yd6RbYnX016Sf6ghiz4cnz-TG3gHk8O5704U ln8GLif3kH FtdQVfZhP7xGdLwzoYft NOTES- 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-6=-54, 6-9=-54, 9-10=-54, 10-14=-54, 25-26=-20, 23-25=-20, 20-22=-20, 18-19=-20, 18-29=-20 Concentrated Loads (lb) Vert: 3=-179(F) 25=-343(F) 24=-59(F) 4=-115(F) 32=-115(F) 34=-59(F) ® WARNING - verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/10/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of individual truss web andfor chord members only. Additional temporary and permanent bracing MOW always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS117P/1 Quality Criteria, DSB-69 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply LOT 12315 WATERSTONE T22727478 2631413 B02 SPECIAL 1 1 Jab Reference o tional Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Feb 410:04:24 2021 Page 1 I D:3xt?Yd6RbYnXO16Sf6ghjjz4cnz-QfBRiQ9fdk GnjbxXO m I789 M b LRAg7ROi b FlkQpzoYfr 4-10-5 8-1-8 9-0-0 14-8-0 21-1-2 27-8-0 29-0-0 4-10-5 3-3-3 -10- 5-8-0 6-5-2 6-6-14 1-4-0 Scale = 1:49.9 3x4 = 3x6 i 5x8 = 3 4 23 5 Io q N 13 3x6 = 3x4 = 6x12 MT20HS = 3x4 = 2x4 11 14-8-0 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2020/TPI2014 CSI. TC 0.73 BC 0.58 WB 0.81 Matrix-MSH DEFL. Vert(LL) Vert(CT) Horz(CT) in (loc) 1/defl Lid -0.10 10-12 >999 240 -0.18 10-12 >999 180 0.02 7 n4 n/a PLATES MT20 MT20HS Weight: 141 lb GRIP 244/190 187/143 FT = 20 LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-11-15 oc purlins. BOT CHORD 2x4 SP No.2 *Except` BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 3-12: 2x4 SP M 31 6-0-0 oc bracing: 1-14. WEBS 2x4 SP No.3 6-0-0 oc bracing: 12-14 WEBS 1 Row at midpt 5-12 REACTIONS. (size) 12=0-4-0, 7=0-8-0 Max Horz 12=-242(LC 8) Max Uplift 12=-694(LC 10), 7=-376(LC 10) Max Grav 12=1691(LC 15), 7=848(LC 16) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-176/548, 2-3=-311/779, 3-4=0/339, 4-5=-34/452, 5-6=-497/333, 6-7=-1 1721556 BOT CHORD 1-14=-447/235, 12-14=-965/670, 3-14=-609/507, 10-12=0/390, 9-10=-310/980, 7-9=-308/986 WEBS 2-14=-331/307, 5-10=-192/670, 5-12=-11071626, 6-9=0/268, 6-10=-797/470 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; VuIt=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5tt; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2E) 0-0-0 to 3-11-10, Interior(1) 3-11-10 to 5-0-6, Exterior(2R) 5-0-6 to 18-7-10, Interior(1) 18-7-10 to 25-0-6, Exterior(2E) 25-0-6 to 29-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 694 lb uplift at joint 12 and 376 Ib,uplift at joint 7. February 4,2021 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/19/2020 BEFORE USE. ' Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36510 Job Truss Truss Type Qty Ply LOT 123/5 WATERSTONE T22727479 2631413 B03 SPECIAL 1 1 Job Reference o floral Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Feb 410:04:26 2021 Page 1 ID:3xt?Yd6RbYnX016Sf6ghhz4cnz-M2JB76Bv9LWVyv4vVAnbDaR DEpLbNw?2ZEgUhzoYfp 7-0-0 7-10-0 12.3-0 16-8-0 z1-3-6 27-8-0 z9-0-o 7-0-0 10-0 4-5-0 45-0 4-7-6 64-10 Scale=1:48.7 3x4 = 3x4 II 4x6 = 3x4 = 6.00 12 2 3 24 4 25 26 27 5 IT e d N 16 4x6 = 3x8 = 2x4 II 3x4 = 1.5x8 STP = 6x8 = 1-1-2 1�i 4-0-0 741-0 7-iq-0 10.8-0 21-3-0 27.8-0 1-0-0 �� 2-10-14 343.0 0- 0 e-10-0 47-e 64-10 Plate Offsets (X,Y)— [1:0-0-4,Edge],[1:0-2-10,0-1-8],[2:0-2-0,0-2-8] [12:0-3-8,0-3-0] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defi L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.45 Vert(LL) 0.17 14-22 >571 240 MT20 244/190 TCDL 7.0 LumberDOL 1.25 BC 0.82 Vert(CT) -0.31 10-12 >756 180 MT20HS 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.68 Horz(CT) -0.06 12 n/a n/a BCDL 10.0 Code FBC2020fTP12014 Matrix-MSH Weight: 138 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-3-7 oc purlins. BOT CHORD 2x4 SP No.2 *Except* BOT CHORD Rigid ceiling directly applied or 7-1-7 oc bracing. Except: 3-12: 2x4 SP No.3 6-0-0 oc bracing: 12-14 WEBS 2x4 SP No.3 WEDGE Left: 2x6 SP No.2 REACTIONS. (size) 12=0-8-0, 7=0-8-0, 1=0-4-0 Max Horz 1=-201(LC 8) Max Uplift 12=-435(LC 10), 7=-498(LC 10), 1=-444(LC 10) Max Grav 12=1017(LC 2), 7=1017(LC 16), 1=415(LC 21) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-266/393, 2-3=-213/442, 3-4=-1961431, 4-5=-906/773, 5-6=-10481784, 6-7=-1535/951 BOT CHORD 12-14=-349/239, 3-14=-270/218, 10-12=-262/523, 9-10=-659/1310, 7-9=-659/1310 WEBS 4-1 0=-1 04/469, 4-12=-731/458, 6-10=-614/405 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2E) 0-0-0 to 3-11-10, Extedor(2R) 3-11-10 to 10-11-10, Interior(1) 10-11-10 to 12-8-6, Extedor(2R) 12-8-6 to 20-7-10, Interior(1) 20-7-10 to 25-0-6, Extedor(2E) 25-0-6 to 29-0-0 zone; cantilever left exposed ; end vertical left exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer/ Project engineer responsible forverifying applied roof live load,shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. .7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0,wide will fit between the bottom chord and any other members, with BCDL = IO.Opsf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 435 lb uplift at joint 12, 498 lb uplift at joint 7 and 444 lb uplift at joint 1. February 4,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5119/2020 BEFORE USE. ' Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Welk' always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply LOT 12315 WATERSTONE T22727480 2631413 B04 SPECIAL 1 1 Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Feb 4 10:04:27 2021 Page 1 I D:3xt?yd6RbYnXO16Sf6q hjjz4cnz-q EsZKS BXvfe Ma3f63u Iq mn_Ade62 Kpm 8 H D-017zoYfo -1-4-0 5-0-0 7-10.0 13-3-0 18-8-0 21-4-10 z7-8-0 zs-0-o 1-4-0 5-0-0 2-10-0 5-5-0 5-5-0 2-8.10 6-3-6 14-0 6.00 12 3x4 = 2x4 II 4x6 = 3x4 = 3 4 23 5 24 25 26 6 1.5x8 STP = 11 12 46 = 3x8 = 3x4 = 6x8 = Scale=1:50.7 co 0 4 T Io 4 N 1-0-0 0-104' , 5-0-0 7-e-0 7-10-0 18-8.0 27.8-0 -104 4-0-0 2-8-0 0- 0 10.10.0 0-1-12 9-0-0 Plate Offsets (X,Y)— [2:0-0-4,Edge], [2:0-0-12,Edge], [3:0-2-0,0-2-8], [8:0-0-4,Edge], [12:0-3-8,0-3-0] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.41 Vert(LL) -0.29 10-12 >804 240 MT20 244/190 TCDL 7.0 LumberDOL 1.25 BC 0.98 Vert(CT) -0.5910-12 >403 180 MT20HS 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.71 Horz(CT) -0.05 12 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-MSH Weight: 130 lb FT = 20 LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-8-4 oc purlins. BOT CHORD 2x4 SP No.2 `Except` BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. Except: 4-12: 2x4 SP No.3 6-0-0 oc bracing: 12-13 WEBS 2x4 SP No.3 WEDGE Left: 2x6 SP No.2 REACTIONS. (size) 12=0-8-0, 8=0-8-0, 2=0-4-0 Max Horz 2=175(LC 9) Max Uplift 12=-492(LC 10), 8=-477(LC 10), 2=-51 O(LC 10) Max Grav 12=934(LC 1), 8=831(LC 16), 2=450(LC 19) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-225/305, 3-4=-193/308, 4-5=-169/343, 5-6=-864/778, 6-7=-997/824, 7-8=-1195/915 BOT CHORD 12-13=-352/297, 4-13=-287/280, 10-12=-357/642, 8-10=-626/1027 WEBS 5-1 0=-41/328, 6-1 0=-1 29/313, 7-1 0=-340/352, 5-12=-756/534 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Exterior(2R) 2-7-10 to 8-11-10, Interior(1) 8-11-10 to 14-8-6, Extedor(2R) 14-8-6 to 22-7-10, Interior(l) 22-7-10 to 25-0-6, Exterior(2E) 25-0-6 to 29-0-0 zone; cantilever left exposed ; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer/ Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. ^8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 492 lb uplift at joint 12, 477 Ib uplift at joint 8 and 510 lb uplift at joint 2. February 4,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 511M020 BEFORE USE. ' Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/f Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. SafetyInformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Oty Ply LOT 123/5 WATERSTONE T22727481 2631413 B05 SPECIAL 1 1 Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Feb 410:04:29 2021 Page 1 I D:3xt?Yd 6 RbYnXO16Sf6 q hjjz4cnz-md_Kl7DoRGu4p Np UAJKIrC3ShSsPop PRkXTV50zoYfm 1-1-4-0 , 3-0-0 7- 2-0 14-3-0 20-8-0 27-8-0 29-0-0 3-0-0 ' 4-10-0 ' 6-5-0 ' 6.5-0 7-0-0 1-4-0 4x6 = 6.00 12 5x6 = 3 21 22 4 YI1 0 2x4 11 23 5 5x8 = 16 1.5x8 STP = 11 "" 12 3x4 = 3x8 = 2x4 II 3x4 = 3x6 11 Scale = 1:50.7 3-0-0 7-8-0 7-14-0 14-3-0 20-8-0 27-8-0 3-0-0 4-8-0 0-'2'-0 6-5-0 6-5.0 7-0-0 Plate Offsets (X,Y)— [4:0-2-4,0-3-0),[6:0-6-0,0-2-8) LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.69 Vert(LL) 0.18 13-14 >529' 240 MT20 2441190 TCDL 7.0 LumberDOL 1.25 BC 0.67 Vert(CT) 0.1513-14 >650' 180 BCLL 0.0 * Rep Stress Incr NO WB 0.38 Horz(CT) -0.07 7 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-MSH Weight: 126 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-0-8 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 7-9-13 oc bracing. Except: WEBS 2x4 SP No.3 5-8-0 oc bracing: 12-13 REACTIONS. (size) 2=0-4-0, 12=0-8-0, 7=0-8-0 Max Horz 2=134(LC 7) Max Uplift 2=-563(LC 8), 12=-655(LC 8), 7=-485(LC 8) Max Grav 2=405(LC 1), 12=1002(LC 1), 7=810(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-400/657, 3-4=-344/626, 4-5=-966/668, 5-6=-966/668, 6-7=-1186/614 BOT CHORD 2-14=-480/332, 13-14=-498/344, 12-13=-936/673, 4-13=-847/502, 9-10=-377/1000, 7-9=-379/993 WEBS 6-9=0/288, 5-10=-373/303, 4-10=-386/1001 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 563 lb uplift at joint 2, 655 lb uplift at joint 12 and 485 lb uplift at joint 7. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 2 lb down and 60 lb up at 13-0-0, and 62 lb up at 5-0-12, and 62 Ito up at 7-0-12 on top chord, and 40 lb down and 139 lb up at 3-0-0, and 15 lb down and 60 lb up at 5-0-12, and 15 lb down and 60 lb up at 7-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-6=-54, 6-8=-54, 13-15=-20, 12-18=-20 Concentrated Loads (lb) Vert: 3=2(F) 14=-20(F) 21=4(F) 22=4(F) 24=-8(F) 25=-8(F) February 4,2021 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE. Design valid for use onlywith MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the - fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI7 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply LOT 12315 WATERSTONE T22727482 2631413 C1 JACK 4 1 Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Feb 410:04:29 2021 Page 1 I D:3xt?Yd 6 RbYnXO16Sf6ghjjz4cnz-md_KI7DoRGu4p Np UAJ KIrC3ZxSO Fou MRkXTV50zoYfm 0-11-4 0-11-4 Scale = 1:7.6 Plate Offsets (X,Y)— [2:0-1-410-0-21 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.23 Vert(LL) 0.00 5 >999; 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.04 Vert(CT) 0.00 5 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 _ 4 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix -MP Weight: 5 lb FT = 20 LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 0-11-4 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling ditectly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=79(LC 10) Max Uplift 3=-3(LC 1), 2=-195(LC 10), 4=-15(LC 1) Max Grav 3=20(LC 10), 2=159(LC 15), 4=44(LC 10) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 3 lb uplift at joint 3, 195 lb uplift at,joint 2 and 15 lb uplift at joint 4. February 4,2021 i ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, thebuilding designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing WOW always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI TP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 123/5 WATERSTONE . T22727483 2631413 C1P Jack -Open 2 1 Jab Reference (optional) ounuc,o team Ly, nanl uity, rL - 000D1, 8.'4JU 5 NOV JU ZUZU MI I eK inausmes, Inc. I nu reD 4 iu:U4mu 2UZl rage 1 ID:193QG WBBpX3jR187zeOm7kz5?ad-EpYiyTEQCaOxRWOhkOsXOQckgsMUXLbazBC2dSzoYfl -1-4-0 0-11-4 1-4-0 0-11-4 Scale = 1:7.6 LOADING (psf) SPACING- 2-0-0 CSI.. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.23 Vert(LL) 0.00 5 >999 240 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.04 Vert(CT) 0.00 5 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 4 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix -MP Weight: 5 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 0-11-4 cc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing. REACTIONS. (size) 3=Mechanical, 2=0-3-8, 4=Mechanical Max Horz 2=79(LC 10) Max Uplift 3=-6(LC 7), 2=-213(LC 10), 4=-23(LC 15) Max Grav 3=15(LC 10). 2=158(LC 1), 4=32(LC 10) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 6 lb uplift at joint 3, 213 lb uplift at joint 2 and 23 lb uplift at joint 4. February 4,2021 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. ' Design valid for use only with MTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing WOW is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 12315 WATERSTONE T22727484 2631413 C1 V SPECIAL 6 1 Job Reference o tional Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Feb 410:04:31 2021 Page 1 ID:193QG W BBpX3]Rl87zeOm7kz5?ad-i?64ApF2zu8o3gztlkNmwd9vQFilGorkCrybAvzoYfk 0-11-4 9 m 0 1 � m Iq I9 00 Scale = 1:7.6 Plate Offsets (X,Y)— [2:0-0-15,Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.23 Vert(LL) 0.00 7 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.04 Vert(CT) 0.00 7 >999 , 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 2 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix -MP Weight: 5 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 0-11-4 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=79(LC 10) Max Uplift 3=-4(LC 1), 2=-181(LC 10), 4=-14(LC 1) Max Grav 3=16(LC 10), 2=158(LC 1), 4=35(LC 10) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4 lb uplift at joint 3, 181 lb uplift at joint 2 and 14 lb uplift at joint 4. February 4,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDEb MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE. Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of individual truss web andlor chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS117P11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss pe QtyPly LOT 123/5 WATERSTONET22727485 TJACK 2631413 C3 4 1 i Job Reference (optional) Builders FirstSDurce (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Feb 4 10:04:31 2021 Page 1 ID:3xt?Yd 6RbYnXO16Sf6 q hjjz4 cnz-i?64Ap F2zu8o3gztlkNmwd9vQ Fh bGorkCrybAvzoYfk 2-11-4 2-11-4 Scale = 1:12.7 2-11-4 2-11-4 Plate Offsets (X,Y)— [2:0-4-0,0-0-41 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.23 Vert(LL) -0.01 4-7 >999 240 MT20 244/190 TCDL 7.0 LumberDOL 1.25 BC 0.11 Vert(CT) -0.01 4-7 >999, 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix -MP Weight: 12 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2,11-4 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=132(LC 10) Max Uplift 3=-52(LC 10), 2=-157(LC 10) Max Grav 3=72(LC 15), 2=197(LC 15), 4=49(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf, h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 52 lb uplift at joint 3 and 157 lb uplift at joint 2. February 4,2021 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 iev.5/19f2020 BEFORE USE. ' Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safely information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldod, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 12315 WATERSTONE T22727486 2631413 C3V SPECIAL 6 1 Job Reference o tional Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Feb 4 10:04:32 2021 Page 1 ID:193QGWBBpX3jRl87zeOm7kz5?ad-BBgSN9FgkBHfhgY3sRu?Trh4Af1 o?F5tQVh9iLzoYfj -14-0 2-11-4 ' 14-0 ' 2-114 Scale = 1:12.7 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.23 Vert(LL) -0.01 4-7 >999' 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.12 Vert(CT) -0.01 4-7 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 3 n/a, n/a BCDL 10.0 Code FBC2020f'rP120.14 Matrix -MP Weight: 12 lb FT = 20 LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-11-4 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=132(LC 10) Max Uplift 3=-57(LC 10), 2=-149(LC 10) Max Grav 3=74(LC 15), 2=196(LC 15), 4=49(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer/ Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSUTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 57 lb uplift at joint 3 and 149 lb uplift at joint 2. February 4,2021 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/19/2020 BEFORE USE. ` Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job s Truss Type Oty Ply LOT 123/5 WATERSTONE FC5 T22727487 2631413 JACK 4 1 Job Reference o tional Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Feb 4 10:04:33 2021 Page 1 ID:3xt?Yd6RbYnXO16Sf6ghjjz4cnz-fOErbVGI VVPW I_7GP9PE02EAL31jkh L1 f9RiEnzoYfi -1-4-0 4-11-4 1-4-0 4-11-4 Scale = 1:17.6 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL.. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TIC 0.52 Vert(LL) 0.06 4-7 >999 240 MT20 2441190 TCDL 7.0 LumberDOL 1.25 BC 0.39 Vert(CT) -0.06 4-7 >908 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix -MP Weight: 18 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-11-4 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=185(LC 10) Max Uplift 3=-107(LC 10), 2=-167(LC 10) Max Grav 3=134(LC 15), 2=267(LC 15), 4=87(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 107 lb uplift at joint 3 and 167 lb uplift at joint 2. February 4,2021 ® WARNING - Verify design pammelers and READ NOTES ON THIS AND INCLUDED mrrEK REFERENCE PAGE MII.7473 rev. 51192020 BEFORE USE. ' Design valid for use only with MiTek® connectors. This design is based only upon parametersshown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa; FL 36610 Job Truss Truss Type Qly Ply LOT 12315 WATERSTONE ' T22727488 2631413 C5V SPECIAL 6 1 Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Feb 410:04:33 2021 Page 1 ID:193QG W BBpX3jR187zeOm7kz5?ad-fOErbVGI VVPW I_7GP9PE02EAk31?khL1 f9RiEnzoYfi -14-0 4-114 14-0 4-114 Scale = 1:17.6 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Vdefl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.56 Vert(LL) 0.06 4-7 >925 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.44 Vert(CT) -0.07 4-7 >875 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.01 3 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix -MP Weight: 18 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-11-4 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=185(LC 10) Max Uplift 3=-112(LC 10). 2=-161(LC 10) Max Grav 3=136(LC 15), 2=265(LC 15), 4=87(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 112 lb uplift at joint 3 and 161 lb uplift at joint 2. February 4,2021 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 ev. 5/1912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI7TPI1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MO 20601 Tampa, FL 36610 Job Truss Truss Type City Ply LOT 12315 WATERSTONE T22727489 2631413 D02 HIP 1 1 Job Reference o tional Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 1.4-0 a 7-0-0 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Feb 4 10:04:34 2021 Page 1 I D:3xt?Yd6RbYnXO16Sf6ghjjz4cnz-7anDorHwGpXNw8iSzswTYGnErTXPT4TAuoAGm DzoYfh 19-11-4 , 21-3-4 , 6-0-0 5x8 = 46 = 3 16 17 4 3x6 = 2x4 11 4x6 = 3x4 = 3x6 = LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 LumberDOL 1.25 Rep Stress Incr NO Code FBC2020/PPI2014 CSI. TC 0.99 BC 0.81 WB 0.26 Matrix-MSH LUMBER - TOP CHORD 2x4 SP No.2 *Except* 3-4: 2x4 SP No.1 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 5=0-8-0 Max Harz 2=-171(LC 6) Max Uplift 2=-784(LC 8), 5=-804(LC 8) Max Gram 2=1422(LC 1), 5=1426(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2542/1275, 3-4=-2217/1247, 4-5=-2531/1309 BOT CHORD 2-9=-974/2206, 7-9=-977/2229, 5-7=-1003/2193 WEBS 3-9=-80/686, 3-7=-298/60, 4-7=-56/694 Scale = 1:36.8 DEFL. in (too) I/deft L/d PLATES GRIP Vert(LL) 0.14 9-12 >999 240 MT20 244/190 Vert(CT) -0.19 9-12 >999 180 Horz(CT) 0.06 5 n/a n/a Weight: 86 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 5-9-0 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; VuIt=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0,wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 784 lb uplift at joint 2 and 804 lb uplift at joint 5. 8) Hanger(s) or other connection devices) shall be provided sufficient to support concentrated load(s) 116 lb down and 87 lb up at 7-0-0, 86 lb down and 162 lb up at 9-0-12, and 86 lb down and 162 lb up at 10-11-4, and 116 lb down and 290 lb up at 13-0-0 on top chord, and 374 lb down and 163 lb up at 7-0-0, 65 lb down at 9-0-12, and 65 lb down at 10-11-4, and 374 lb down and 163 lb up at 12-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-4=-54, 4-6=-54, 10-13=-20 Concentrated Loads (lb) Vert: 3=-116(B) 4=-116(B) 9=-374(B) 7=-374(B) 16=-86(B) 17=-86(B) 18=-40(B) 19=40(B) February 4,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE. Design valid for use onlywith MTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MOW is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1rFII Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 , I i b Job Truss Truss Type City Ply LOT 12315 WATERSTONE T22727490 2631413 E3 JACK 3 1 Job Reference o tional Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Feb 410:04:35 2021 Page 1 ID:3xt?Yd6 RbYnX016Sf6 q hjj z4cnz-bm Lb 0 B IY16fEYl HeXZRi5TJbQt2U CbrJ 7SwpJgzoYfg -1-4-0 3-0-0 1-4-0 3-0-0 Scale = 1:12.8 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.23 Vert(LL) 0.01 4-7 >999 240 MT20 2441190 TCDL 7.0 LumberDOL 1.25 BC 0.12 Vert(CT) -0.01 4-7 >999' 180 BCLL 0.0 Rep Stress [nor YES WB 0.00 Horz(CT) -0.00 3 nla nla BCDL 10.0 Code FBC2020rrP12014 Matrix -MP Weight: 12 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=04-0, 4=Mechanical Max Horz 2=133(LC 10) Max Uplift 3=-64(LC 10), 2=-213(LC 10), 4=-42(LC 7) Max Grav 3=66(LC 15), 2=197(LC 1), 4=50(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2E) zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0,wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 64 lb uplift at joint 3, 213 lb uplift at joint 2 and 42 lb uplift at joint 4. February 4,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 511912020 BEFORE USE. ' Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing' MiTek• Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems,. see ANS11TPH Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type I Qty Ply LOT 123/5 WATERSTONE T22727491 2631413 E7 JACK 4 1 Job Reference (optional) uw.�rna ruawwi�o trio... inry, r�l, nanr .,..y, r� - oouor, 0.40U s rvuv oU [UN Na r eK inuusines, mc. I nu reo 4 l U:U4:30 /Uzi rage i ID:3xt7Yd6RbYnXO16Sf6ghj z4cnz-bmLb0BIY16fEYIHeXZRi5TJQJttSCbrJ7SwpJgzoYfg 1 4-0 7-0-0 1-4-0 7-0-0 Scale=1:22.6 3x6 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.94 Vert(LL) 0.22 4-7 >381 , 240 MT20 244/190 TCDL 7.0 LumberDOL 1.25 BC 0.82 Vert(CT) -0.23 4-7 >368 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.01 3 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix -MP Weight: 24 lb FT = 20% LUMBER - TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.2 REACTIONS. (size). 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=241(LC 10) Max Uplift 3=-162(LC 10), 2=-184(LC 10) Max Grav 3=198(LC 15), 2=343(LC 15), 4=124(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 7-7-14 oc bracing. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0'wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 162 lb uplift at joint 3 and 184 lb uplift at joint 2. February 4,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE. Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall /� building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1rPl1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. SafetyInformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Type Qty Ply LOT 123/5 WATERSTONE TE'1UVs T22727492 2631413 SPECIAL 10 1 Job Reference (optional) FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Feb 410:04:36 2021 Page 1 ID:193QGW BBpX31R187zeOm7kz5?ad-3zvzDXIBoQn59Rrg5HyxdhsaCGCpx25TL6fMr6zoYff 1 4-0 7-0-0 1-4-0 i --- 700 Scale = 1:22.6 3x6 Plate Offsets (X,Y)— [2:0-0-14,0-0-71 LOADING (psf) SPACING- 2-0-0 CST. DEFL. in (loc) Ildefl' Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 1.00 Vert(LL) 0.23 4-7 >354 , 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.88 Vert(CT) -0.23 4-7 >356 - 180 BCLL 0.0 Rep Stress [nor YES WB 0.00 Horz(CT) -0.03 3 n/a n/a BCDL 10.0 Cade FBC2020frP12014 Matrix -MP Weight: 25lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP No.1 TOP CHORD Structural wood sheathing directly applied. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 4-9-5 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=241(LC 10) Max Uplift 3=-166(LC 10), 2=-179(LC 10) Max Grav 3=200(LC 15), 2=341(LC 15), 4=124(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 166 lb uplift at joint 3 and 179 lb uplift at joint 2. February 4,2021 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19l2020 BEFORE. USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for on individual building component, not • a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 i f 1 k Job Truss Truss Type Qty Ply LOT 123/5 WATERSTONE T22727493 2631413 E7VP SPECIAL 7 1 Job Reference o tional trtani t ity, FL), mant tarty, hL - SSbbf, 8A30 s Nov 30 2020 MiTek Industries, Inc. Thu Feb 410:04:37 2021 Page 1 ID:3xt?Yd6RbYnXO16Sf6ghjjz4cnz-X9TLQsJpZkvxnbQ1 e_UAAuPoQgZMgVKcam PwNYzoYfe -"-0 7-0-0 1-4-0 7-0-0 Scale = 1:22.6 3Xb Plate Offsets (X,Y)— f2:0-6-7,0-0-51 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.77 Vert(LL) 0.21 4-7 >387 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.79 Vert(CT) 0.19 4-7 >436 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.D1 3 n/a n/a BCDL 10.0 Cade FBC2020fTP12014 Matrix -MP Weight: 31 lb FT = 20% LUMBER - TOP CHORD 2x4 SP No.1 BOT CHORD 2x6 SP No.2 REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=308(LC 10) Max Uplift 3=-153(LC 10), 2=-307(LC 10), 4=-150(LC 10) Max Grav 3=157(LC 15), 2=336(LC 1), 4=140(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. BRACING - TOP CHORD Structural wood sheathing directly applied or 4-11-3 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-1 oc bracing. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf, h=15ft; B=4511; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2E) zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 153 lb uplift at joint 3, 307 lb uplift'at joint 2 and 150 lb uplift at joint 4. February 4,2021 ® WARNING - Verify design parametersand READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/1912020 BEFORE USE. ' Design valid for use only with Mrrek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/Tp/1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 123/5 WATERSTONE T22727494 2631413 H3 JACK 1 1 Job.Raference o tienal Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Feb 4 10:04:37 2021 Page 1 ID:3xt?Yd6RbYnXO16Sf6ghjjz4cnzTX9TLQsJpZkvxnbQ1 e_UAAuPwCgkKgVKcamPwNYzoYfe 4-2-3 4-2-3 Scale=1:12.6 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.27 Vert(LL) 0.01 4-7 >999 : 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.09 Vert(CT) -0.01 4-7 >999 180 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix -MP Weight: 16 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-2-3'oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-4-8, 4=Mechanical Max Horz 2=133(LC 8) Max Uplift 3=-58(LC 8), 2=-246(LC 8), 4=-48(LC 5) Max Grav 3=73(LC 1), 2=234(LC 1), 4=54(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11;Exp C; Encl., GCpi=0.18; MWFRS (directional); porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer/ Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) oftruss to bearing plate capable ofwithstanding 58 lb uplift atjoint 3, 246 lb uplift atjoint 2 and 48 lb uplift at joint 4. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 56 lb down and 62 lb up at 1-5-12, and 56 lb down and 62 lb up at 1-5-12 on top chord, and 22 lb up at 1-5-12, and 22 lb up at 1-5-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 4-5=-20 Concentrated Loads (lb) Vert: 8=46(F=23,B=23)9=22(F=11,B=11) February 4,2021 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/1912020 BEFORE USE. ' Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1TP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 ( 1 01 Job Truss Truss Type Qty Ply LOT 123/5 WATERSTONE T22727495 2631413 H7 MONO TRUSS 2 1 Job Reference o lional tduuaers mrst5ource (giant uty, t-L), t'lant Gity, FL - 33557, 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Feb 410:04:38 2021 Page 1 ID:3xt?Yd6RbYnXO16Sf6ghgz4cnz-?L1jeCKRK11 oPl?DCi?Pj6x?x4wNPsVmpQ8Tv?zoYfd -1-10-10 4-6-7 9-10-1 ' 1-10-10 ' 4-6-7 5-3-10 4-6-7 9-10-1 4-6-7 r 5-3-10 LOADING (pso TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr NO Code FBC2020/TP12014 CSI. TC 0.66 BC 0.74 WB 0.39 Matrix-MSH DEFL. Vert(LL) Vert(CT) Horz(CT) LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD BOT CHORD 2x4 SP No.2 BOT CHORD WEBS 2x4 SP No.3 REACTIONS. (size) 4=Mechanical, 2=0-8-0, 5=Mechanical Max Horz 2=240(LC 8) Max Uplift 4=-166(LC 8), 2=-226(LC 8), 5=-78(LC 8) Max Grav 4=159(LC 1), 2=443(LC 1), 5=300(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-734/233 BOT CHORD 2-7=-330/681, 6-7=-330/681 WEBS 3-7=0/322, 3-6=-719/349 in (loc) Vdefl L/d -0.07 6-7 >999 240 -0.15 6-7 >788 180 0.01 5 n/a n/a Scale = 1:22.0 PLATES GRIP MT20 244/190 Weight: 43 lb FT = 20% Structural wood sheathing directly applied or 6-0-0 oc purlins. Rigid ceiling directly applied or 9-8-5 oc bracing. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=51t; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) . This truss has been designed for a live load of 20.Opsf on the bottom chord in allareas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 166 lb uplift at joint 4, 226 lb upliftat joint 2 and 78 Ib uplift at joint 5. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 56 lb down and 62 lb up at 1-5-12, 56 lb down and 62 lb up at 1-5-12, 5 lb down and 68 lb up at 4-3-11, 5 lb down and 68 lb up at 4-3-11, and 50 lb down and 138 lb up at 7-1-10, and 50 lb down and 138 lb up at 7-1-10 on top chord, and 22 lb up at 1-5-12, 22 lb up at 1-5-12, 11 lb down and 7 lb up at 4-3-11, 11 lb down and 7 lb up at 4-3-11, and 51 lb down at 7-1-10, and 51 lb down at 7-1-10 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. �8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plo Vert: 1-4=-54, 5-8=-20 February 4,2021 Continued on page 2 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicabilityof design parameters and properly incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 A l • 1 Job Truss Truss Type City Ply WATERSTONET22727495 FLOT123/5 2631413 H7 MONO TRUSS 21eference (optional) tsunaers virstoource triant uny, t-L1, rtant L;ny, t-L - 33bbf, 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Feb 4 10:04:38 2021 Page 2 ID:3xt?Yd6RbYnX016Sf6ghjjz46nz-?L1jeCKRK11 oPl?DCi?Pj6x?x4wNPsVmpQ8Tv?zoYfd LOAD CASES) Standard Concentrated Loads (Ib) Vert: 3=36(F=18, B=18) 7=-11(F=-5, B=-5) 11=46(F=23, B=23) 12=-99(F=-50, B=-50) 13=22(F=11, B=11) 14=-51(F=-25, B=-25) ® WARNING •Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 511912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web andlor chord members only. Additional temporary and permanent bracing MiTek• Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 . r . Job Truss Truss Type Qty Ply LOT 12i 315 WATERSTONE T22727496 2631413 H7V SPECIAL 3 1 Job Reference o tional Builders FlrstScurce (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Feb 410:04:39 2021 Page 1 ID:193QGW BBpX3jR187ze0m7kz5?ad-TYb6rYL35L9fOvaPmPWeFJUBfUIL8KVvl4uOSRzoYfc 1-10-10 5-4-1 9-10-1 1-10-10 5-4-1 4-6-0 2 3x4 5-4-1 Scale=1:22.1 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.60 Vert(LL) 0.09 6-7 >999 240 MT20 244/190 TCDL 7.0 LumberDOL 1.25 BC 0.63 Vert(CT) -0.12 6-7 >999 180 BCLL 0.0 Rep Stress Incr NO WB 0.34 Horz(CT) 0.01 5 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-MSH Weight: 41 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-8-1 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-10-7 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 4=Mechanical, 2=0-8-0, 5=Mechanical Max Horz 2=240(LC 8) Max Uplift 4=-170(LC 8), 2=-248(LC 8), 5=-163(LC 5) Max Grav 4=141(LC 1), 2=439(LC 1), 5=300(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-998/624 BOT CHORD 2-7=-689/933, 6-7=-699/932 WEBS 3-7=0/293, 3-6=-918/685 NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf, BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing atjoint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 170 lb uplift at joint 4, 248 lb uplift at joint 2 and 163 lb uplift at joint 5. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 67 lb down and 52 lb up at 1-5-12, 67 lb down and 52 lb up at 1-5-12, 80 lb up at 4-3-11, 80 lb up at 4-3-11, and 50 lb down and 174 Ib up at 7-1-10, and 50 lb down and 174 Ib up at 7-1-10 on top chord, and 23 lb up at 1-5-12, 23 lb up at 1-5-12, 11 lb down and 7 lb up at 4-3-11, 11 lb down and 7 lb up at 4-3-11, and 51 lb down at 7-1-10, and 51 lb down at 7-1-10 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). ,LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-54, 5-8=-20 February 4,2021 continued on page 2 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1012020 BEFORE USE. Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and Is for an individual building component, not ,• a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall � /� building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing nlliTek" Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criterla, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 .: . Job Truss Type My Ply LOT 123/5 WATERSTONE THr.s T22727496 2631413 SPECIAL 3 1 Job Reference (optional) ounuere Fir5mource (riant ury, M), rrant Lary, M - 33bbf, 8.430 s Nov 30 2020 MiTek Industries, Inc. Thu Feb 4 10:04:39 2021 Page 2 ID:193QGWBBpX3jR187zeOm7kz5lad-TYb6rYL35L9fOvaPmPWeFJUBfU I L8KVvl4uOSRzoYfc LOAD CASE(S) Standard Concentrated Loads (Ib) Vert: 11=49(F=24, B=24) 12=36(F=18, B=18) 13=-99(F=-50, B=-50) 14=23(F=11, 13=11) 15=-11(F=-5, B=-5) 16=-51(F=-25, B=-25) A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/1912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIMP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Symbols PLATE LOCATION AND ORIENTATION 3j4' Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. 0-1/1B , For 4 x 2 orientation, locate plates 0- Vi ' from outside edge of truss. - This symbol indicates the required direction of slots in connector plates. "Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the plate 4 x 4 width measured perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Industry Standards: ANSVTPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths (Drawings not to scale) 1 2 BOTTOM CHORDS 8 7 3 6 S JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. PRODUCT CODE APPROVALS [CC -ES Reports: ESR-1311, ESR-1352, ESR1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. © 2012 MiTek® All Rights Reserved 0 MR, k1i MiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020 A General Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSIrrPI 1 Quality Criteria. 21.The design does not take into account any dynamic or other loads other than those expressly stated.