HomeMy WebLinkAboutRockwork Detail Plans1251 Carolyn Dr. Clermont, FL 34711352-241-4908P. 1 of 3 1. ENGINEERING MEETS OR EXCEEDS 2020 FLORIDA BUILDING CODE 7th EDITION, USING ASCE 7-16, 155 mph BASIC WIND SPEED. EXPOSURE C, RISK CATEGORY II. 2. POURED CONCRETE SHALL BE 3000 PSI (MIN.) CMU SHALL BE 1500 PSI (MIN.) MORTER SHALL BE TYPE M 3. REINFORCEMENT BARS ARE TO BE #3 BAR GRADE 40 UNLESS NOTED OTHERWISE. LAP AT SPLICE SHALL BE 12" MINIMUM 4. FOOTINGS ARE DESIGNED FOR A MINIMUM SOIL BEARING CAPACITY OF 2000 PSF. Wayne A. Block PE # 52583 A . BELNOYCAKWNESCEIL FLOR I D A R E PER NIO GFNEES S LIAON No. 52583 STATE OF Lildon Engineering Company, Inc. 920 Sunset Shores Dr. Minneola, Florida 34715 (352) 394-2590 Ph.& FAX Cert. Auth. # 2898 March 11, 2021MACK7840 SADDLEBROOK DR.PORT ST. LUCIE, FL 34986DESIGN LOADS + WIND PRESSURE = 30 PSF LIVE LOAD = 40 PSF DEAD LOAD = 100 PSF STAIRS = 40 PSF RAILING = 200 LB POINT LOAD ANYWHERE ON RAIL RAILING MESH = 50 LB POINT LOAD ANYWHERE ON MESH REINFORCED CONCRETE DESIGNED FOR TOTAL VERTICAL LOAD OF 170 PSF AND HORIZONTAL LOAD OF 40 PSF. This item has been electronically signed and sealed by Wayne A. Block, PE #52583. Printed copies of this item are not official copies. Signature must be verified on electronic copies. +5.2’ STAIRS 9 RISERS AT 6-⅞” 11” TREAD (MIN) +7’ +2’ +7’ +6’ +3’ PLAN VIEW 1/8” = 1’-0” SUPPORT COLUMN WITH FOOTING PAD (TYP) 6x6 #2PT POST 1.25" DIA ROPE T&B (TOP AT 36" ABOVE STAIRS) TWINE MESH, 1-3/4x1-3/4" OPENINGS (TYP) PREFAB SLIDE BY OTHERS WATERFALLB B A A 1 1 ’ - 0 ” (M A X ) PSbox8-12” w/ #5 BAR T&B P. 2 of 3 A . BELNOYCAKWNESCEIL FLOR I D A R E PER NIO GFNEES S LIAON No. 52583 STATE OF Wayne A. Block PE # 52583 Lildon Engineering Company, Inc. 920 Sunset Shores Dr. Minneola, Florida 34715 (352) 394-2590 Ph.& FAX Cert. Auth. # 2898 1251 Carolyn Dr. Clermont, FL 34711352-241-4908SEE CONSTRUCTION DETAILS ON PAGE 3 FOOTING AT PERIMETER FOOTING AT PERIMETER STAIRS 9 RISERS AT 6-7/8” 11” TREAD (MIN) SECTION DETAIL A - A GRADE GROTTO (TYP) HAND RAIL (SEE DETAIL)5’-2”36” (MIN) LANDING SUPPORT COLUMN FOOTING AT PERIMETER POOL SHELL & BENCH BY OTHERS WATERFALL BASIN STEP GROTTO (TYP)5’-2”SECTION DETAIL B - B POOL WATER LEVEL SUPPORT COLUMN This item has been electronically signed and sealed by Wayne A. Block, PE #52583. Printed copies of this item are not official copies. Signature must be verified on electronic copies. March 11, 2021MACK7840 SADDLEBROOK DR.PORT ST. LUCIE, FL 34986PSbox8-12” w/ #5 BAR T&B NTS BOULDER DETAILS POOL SHELL PER POOL PLANS #3 BAR x 8", 3" EMB., 12" OC (MIN. 2 PER BOULDER, DRILL & EPOXY AT POOL SHELL) 8x12 FTG6’MAXLARGE CONCRETE BOULDER 6" MIN CONSTRUCT PER HORZ. & VERT. SECTIONS 3’MAXSMALL CONCRETE BOULDER 5" MIN #3 BAR x 8", 3" EMB., 12" OC (MIN. 2 PER BOULDER, DRILL & EPOXY AT POOL SHELL) POOL SHELL PER POOL PLANS 8" MIN #3 BAR CONT. 4’ MAX 1" COVER (MIN) AT BOTTOM 7" MIN THICKNESS #3 BAR 12" OC EA. WAY 6" COVER (MIN) AT TOP 8'-0" MAX SPAN TYPICAL SECTION (PREDOMINANTLY HORIZONTAL)24x24x10 CONCRETE FTG WITH (3) #3 BAR EA. WAY 3" COVERVARIES12'-0" (MAX)COMPACTED EARTH 12x12 CMU COLUMN GROUT-FILLED WITH (2) #3 BAR TO FTG TYPICAL SECTIONS AT COLUMNS 24x24x10 CONCRETE FTG WITH (3) #3 BAR EA. WAY 3" COVERVARIES8'-0" (MAX)COMPACTED EARTH 8x8 CMU COLUMN GROUT-FILLED WITH (2) #3 BAR TO FTG POOL SHELL PER POOL PLANS #3 BAR x 8", 3" EMB. AT 12" OC DRILL & EPOXY AT POOL SHELL GROTTO TO SHELL CONNECTION POOL SHELL PER POOL PLANS (2) #3 BAR x 8", 3" EMB. DRILL & EPOXY AT POOL SHELL 8x12 or 8x16 FTG FOOTING TO SHELL CONNECTION #3 BAR 12" OC EA. WAY 1.5" COVER 8x12 CONCRETE FTG WITH (2) #3 BAR CONT. 6" MIN THICKNESS TYPICAL SECTION AT PERIMETER (PREDOMINANTLY VERTICAL) COMPACTED EARTH8'-0" (MAX) #3 BAR 8" OC EA. WAY 2" COVER 8x16 CONCRETE FTG WITH (2) #3 BAR CONT. 8" MIN THICKNESS COMPACTED EARTH12'-0" (MAX)P. 3 of 3 A . BELNOYCAKWNESCEIL FLOR I D A R E PER NIO GFNEES S LIAON No. 52583 STATE OF 1" COV E R ( M I N) A T B O T T O M #3 BAR 12" OC 5" C O V E R ( M I N) A T T O P 6" MIN THICKNESS #3 BAR BELOW EDGE OF EACH STEP TYPICAL STAIR SECTION 7-5/8” RISERS & 11” TREAD Wayne A. Block PE # 52583 Lildon Engineering Company, Inc. 920 Sunset Shores Dr. Minneola, Florida 34715 (352) 394-2590 Ph.& FAX Cert. Auth. # 2898 1251 Carolyn Dr. Clermont, FL 34711352-241-4908This item has been electronically signed and sealed by Wayne A. Block, PE #52583. Printed copies of this item are not official copies. Signature must be verified on electronic copies. 6x6 #2PT POST EMBEDDED 12" INTO CONCRETE WITH (2) #3 BAR x12" ADJACENT POST 1.5" DIA POLYESTER ROPE T&B 36" TWINE MESH, 1-3/4x1-3/4" OPENINGS NOTE: RAILING TO SUPPORT 200 LB POINT LOAD POST & ROPE RAILING DETAIL DRILL THROUGH CENTER OF POST AND FASTEN w/ (2) #10x2.5” SCREWS NET LASHED TO ROPE T&B w/ 1/4” POLYESTER ROPE 6x6 #2PT POST EMBEDDED 12" INTO CONCRETE WITH (2) #3 BAR x12” ADJACENT POST 1.5" DIA POLYESTER ROPE T&B 3/4" DIA POLYESTER ROPE, INTERTWINE THROUGH EACH 1.75” APERTURE IN NETTING 1/2" COPPER PIPE HANGERS ANCHORED TO POST w/ #10x1-1/4” COATED SCREWS AT 9” O.C. March 11, 2021MACK7840 SADDLEBROOK DR.PORT ST. LUCIE, FL 34986VARIES9'-0" (MAX)12x12 CMU COLUMN GROUT-FILLED WITH (2) #3 BAR TO FTG COLUMN SECTION AT SHELL POOL SHELL PER POOL PLANS MINIMUM 12” w/ DOUBLE MAT #3 BAR 12” OC EA. WAY #3 BARS x 12", 6" EMB. DRILL & EPOXY AT POOL SHELL BOX LINTEL PER PLAN 6” MIN COVER VARIES9'-0" (MAX)12x12 CMU COLUMN GROUT-FILLED WITH (2) #3 BAR TO FTG COLUMN SECTION w/ FOOTER 24x24x12 CONCRETE FTG WITH (3) #3 BAR EA. WAY 3" COVERCOMPACTED EARTH BOX LINTEL PER PLAN 6” MIN COVER GROTTO OVERHANG DETAIL PSbox8-12” w/ #5 BAR T&B 4" COVER (MIN) AT TOP #3 BAR 6" OC EA. WAY (2” COVER MIN) 36” (MAX) 1” (MIN) CLEARANCE