Loading...
HomeMy WebLinkAboutAPPROVED Engineering Submittal-DigiCert, Turney, 2.16.21(1) PRODUCT APPROVAL Product Opening Design Product Rated Manufacturer Model Number Product Approval Glass Method of Attachment Pressures ssurs __ Nambar T e . NjC Rr, ,: SEVES GLASS RIGID PVC PC LASTIC CHANNEL �% Z l + ¢ PLAN . -�...a q ,�'P_y._._,�►.��.:—��..-- .�'� THICKSET 90 8x8x4 SEVES GLASS BLOCK STRUCTURE` —_ 8x3x4 SEVES GLASS BLOCK THICKSET 90 STRUCTURE' RIGID PVC PLASTIC SPACER PERIMETER FRAMING SEALANT LOCATIONS F- GLASS BLOCK JOINTNSUBSTPATE PERIMETER FRAMING SEALANT LOCATIONSSEALANT LOCATIONS (LENGTH OF CHANNEL) q g RIGID PVC PLAST `" ( Zi'1_- CHANNEL PRE-PUNCHED HOLES FOR ANCHORING 4 I 4'-0"MAXIMUM L �sd NOMINAL WIDTH SECTION a ELEVATION tMPACTRESISTANT 6 BLOCKS x 12 BLOCKS DESIGN PRESSURE RATING SPECIFICATION NOTES: - :80.0 PSF - r • GLASS BLOCK UNITS:Thickset @ 90 Series 8V'X4"or 6`6x4"(nominal size), o r fi • FRAME AND SPACERS:Extruded while rigid PVC.Frame comers are cut square or mitered and are silicone sealed.Extruded by Cardinal Systems,Inc. • SEALANT:Seves Glass Block Sealant.One part neutral fast curing structural silirxme seala;rt. a f • SEALANT LOCATIONS:All twrizontai and vertical glass Gluck joints;inside comers of perimeter channels;two beads(Y`from each edge)between hack of perimeter channels and framing members;two beads each above and below"long"horizontal spacer and"short`vertical spacers;perimeterjoints between glass block and channel lags;and perimeterjoints between channels and flaming members. • REINFORCEMENT:PVC spacers between all horizontal and vertical dints.Spacers in channels are not required. - SHIM SPACES:Mar,(mum%'shim space between the perimeter channel and wood frame. + FIELD INSTALLATION:Loose materials(glass block,spacers,channels and sealant)are available from Seves Glass Block authorized duUibutom,dealers and home centers for on-site installation. Complete window units,framed within 20 treated lumber,and pre-fabricated by Seves Glass Block in accordance with these instructions.are also available from authorized distributors,dealers and home centers.NOTE:These windows are recommended for RESIDENTIAL APPLICATIONS ONLY. ANCHORAGE SCHEDULE- — — ! �,✓a'__ c ` SUBSTRATE MATERIAL DATA FASTENER SPACING MIN.EMBEDMENT(E) MIN.EDGE DISTANCE(E.D.) L ( C j �� � j ' �, _ f ^c GENERAL NOTES. STEEL MIN.18 GA, 910-16 HWH ITW TEK 2'FROM CORNER, 3 THREADS PENETRATION /• �` • v y e fir; Pr=33 KSi SCREW GR.5(FLAT HEAD) 6Y2"O,C, BEYOND STEEL FRAMING 7 CONCRETE � MIN.f4=3000 PSI %s"0 HILT KWIK CON 11+ 2"FROM CORNER, 1" +y" � " .,�t 1. THE OWNER WOULD LIKE TO REMOVE AN EXISTING 6080 SLIDING (FLATHEAD) �"oo, �,' GLASS DOOR IN THE KITCHEN. Y16"01TWTAPCONS 2"FROM CORNER, 1" f 2"1 ` - 2. SHE WOULD LIKE TO REPLACE IT WITH A GLASS BLOCK WINDOW I6/"n.C. I� ( � AND CBS INFILL. _ —......... _ MASONRY CONFORMS TOASTMC99 s/,6°0 HILTI KWIK CON If+1 2"FROM CORNER, 1" 1Ya -' - 3. THE INFILLED AREA TO BE INSULATED WITH FI-FOIL R-4.5 AND GROUT CONFORMS TO (FLAT HEAD) �"O.C. 1 » ASTM C476 MIN.GROUT l I FURRING WITH /2 DRYWALL ON INTERIOR. is=2000PSI X,a°0 ITti1'TAPCONS 2"FROM coRNER,11" 2° 4. STUCCO ON EXTERIOR TO MATCH EXISTING WITH PAINT. 6v^O.C. -- -- 5. 8" x 8" GLASS BLOCKS WITH IMPACT RATING INSTALLED PER WOOD MIN,S.G.=0.55 98 WOOD SCREW 2"FROM CORNER, 1-1/2" �" FLORIDA PRODUCT APPROVAL. (FLAT HEAD) �O.C. _ 6. THERE IS NO ELECTRICAL, PLUMBING OR HVAC WORK REQUIRED. SEVES GLASS BLOCK 7. ALL WORK TO BE IN COMPLIANCE WITH THE 2020 FLORIDA SERIES I PATTERN NOMINAL DIM. MIN,FACE THICKNESS BUILDING CODE 7t" EDITION AND ASCE 7-16.. THICKSET00 NUBIOe 8"x8"x4" 0,751N. 8. OWNER TO VERIFY ALL DIMENSIONS AND STUCTURAL 6"x6"x4" 0.751N. CONDITIONS.AS SHOWN ON THE PLANS. ANY DISCREPENCY THICKSET090 I CLARITYe 8"x8"x4" 0.75IN. WALL SECTION-,. BETWEEN THE PLANS AND THE ACTUAL EXISTING CONDITIONS fi"x6"x4" 0.T5 fN. "- SHOULD BE REPORTED TO THE ENGINEER. THICKSET*90 E:N:D:U::P:A:@::f— ft'&x4° 0.751N. 1 » SCALE / —�------ _GLASS BLOCK INFORMATION{_ o (.ornplete all that apply) z. clEstt;fa ct : Flor'sda 2. Structure Designed as# one): /Enclosed Partially Enclosed Open 3, Risk Category: —1 !f, Ill —IV Exposure Category: ✓8 C ___.,t3 4. Design Wind Velocity 0 Mph -K!ASO LRFD End Zcxrrw Width. h —*— S. Mean Roof Height ,_-I S/ ft Roof Pitch:._ _:12 Parapet: ft F- Components&Cladding Design Pressures Used:(PSF,based an 105gfi @ 1:5'MRH,clearly label on all plan openings); a Zone 3: "— Zone 2: Zone 3: Zane 4: a 5:_4f_d - Game: —� 7. resign loads: Floor:,5 PSF Roof/Dead: '��PSF Rocsf/Live:"y�, Balcony: PSF d't•E� �' , Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: _ PSF KITCHEN _ KITCHEN _ Were Shear ear Walls considered For Structure? .-.,,/yes _ Not Explain Why Not: 9. is A Continuous toad Path Provided?_ZYes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure:441L�PSF Soil Test Reports Submitted? Yes Design by: REVISED FLOOR PLAN J EXISTING FLOOR PLAN -- RICHARD A. JEMISON SCALE %" SCALE %" P.O. Box 5616 Ft. Pierce, Fl. 34954 (772) 215-5623 G. yy i This item has been electronically signed BENCHMARK ENGINEERING N and sealed by Bowdoin G. Hutchinson, P.E. OF THE TREASURE COAST r ��7 806 DELAWARE AVE. "0 ; using a Digital Signature and Date. Printed FT.PIERCE,FL.34950 r * = copies of this document are not considered (772)772-267-1399 02/15/21 ,�< OP , : �\ signed and sealed and the signature must SEAL REMOVE SGD & INFILL WALL SHEET SS,i� ORipp. be verified on any electronic copies. INSTALL GLASS BLOCKS & PANTRY 0AIAL ENG������ _ N TURNEY �ir1111+►�! DN: c--US, st=Florida, I--Fort Pierce, o Bowdoin G. BOWDOIN KATHRY Hutchinson, cn=Bowdoin G. Hutchinson HUTCHINSON 9125 PUMPKIN RIDGE Bowdoin G . Hutchinson _ s P.E.#70878 PORT ST. LUCIE, FLORIDA OF 1 Date: 2021 .02.1618:37:49 05'00' Adobe Acrobat version: 2021 .001 .20135