Loading...
HomeMy WebLinkAboutAPPROVED CAROLINA CARPORT GENERIC 2020FBC - ESS page 1FBC APPROVED PRODUCTS LIST MAXIMUM ALLOWABLE TABLE 1 WIND SPEED RAFTER FRAME, END POST, GROUND ANCHOR AND PANEL FASTENER SPACING SPECIFICATIONS APPROVAL QA PARTIALLY AVERAGE FASTENER SPACING PRODUCT CATEGORY SUB CATEGORY MANUFACTURER No. &DATE EXPIRATION DATE OPENENCLOSED ENCLOSED RISK WIND EXPOSURE ULTIMATE WIND SPEED NOMINAL WIND SPEED MAXIMUM POST / RAFTER SPACING ON -CENTERS ALONG RAFTERS OR PURLINS, AND POSTS OR GIRTS (INCHES) STRUCTURAL COMPONENTS ROOF DECK CAROLINA CARPORTS, INC. 26 Gauge AG Panel FL6596.1-R6 12/15/20 04/05/27 180 180 180 INTERIOR END STRUCTURAL COMPONENTS STRUCTURAL WALL CAROLINA CARPORTS, INC. FL6702.1-R6 03/14/27 180 180 180 CATEGORY CATEGORY (MPH) (MPH) (FEET) POSTS/RAFTERS POSTS/RAFTERS 26 Gauge AG Panel 12/15/20 I C 110 TO 150 89 TO 116 5.0 6 6 STRUCTURAL COMPONENTS STRUCTURAL WALL CAROLINA CARPORTS, INC. 26 Gauge Dutch Lap Wall Panel FL6702.3-R6 12/15/20 ** 03/14/27 N/A 164 143 151 TO 180 117 TO 139 4.0 6 6 STRUCTURAL COMPONENTS FLOOD VENT CRAWL SPACE DOOR SYSTEMS, INC. FL29622.1 09/30/22 N/A N/A N/A NOTES: 1. Specifications applicable to 26 gauge metal roof and wall panels fastened directly to 12 or 14 gauge steel tube framing, or 18 16x8 Flood Vent 05/15/19 gauge hat channel roof purlins. EXTERIOR DOORS SWINGING ELIXIR DOOR AND METAL COMPANY Series 402-14 FL17996.3-R1 02/04/18 09/14/20 N/A 156 138 2. Specifications applicable only for mean roof height of 20 feet or less, and roof slopes of 7° to 27' (1.5:12 to 6:12 pitch). Spacing requirements for other roof heights and/or slopes may vary. GROUND ANCHOR SCHEDULE EXTERIOR DOORS SWINGING ELIXIR DOOR AND METAL COMPANY Series 407 FL17996.5-R1 02/04/18 09/14/20 N/A 165 147 METAL CARPORT INSTALLATION PLANS AND DETAILS AND FRAMING AND ULTIMATE WIND SPEED (mph) 110 120 130 140 150 160 170 180 EXTERIOR DOORS EXTERIOR DOORS EXTERIOR DOORS EXTERIOR DOORS EXTERIOR DOORS WINDOWS ROLL -UP ROLL -UP ROLL -UP ROLL -UP ROLL -UP SINGLE HUNG ASTA INDUSTRIES INC. Model 203 (12' Max. Width) CAROLINA CARPORTS, INC. Steel Roll Up Sheet Door (12' Max. Width) CAROLINA CARPORTS, INC. Steel Roll -Up Sheet Door - (8' Max. Width) CAROLINA CARPORTS, INC. Steel Roll -Up Sheet Door - (16' Max. Width) CAROLINA CARPORTS, INC. Steel Roll -Up Sheet Door - (10' Max. Width) MI WINDOWS AND DOORS Model 185SH FL8888.1-R6 12/29/20 FL16806.1-R5 12/16/20 FL16806.2-R5 12/16/20 FL16806.3-R5 12/16/20 FL16806.4-R5 12/16/20 FL17499.1-R8 11/27/20 1 12/31/21 04/05/29 04/05/27 04/05/27 04/05/27 10/17/23 N/A N/A N/A N/A N/A N/A 180 158 180 155 180 175 174 138 180 133 172 157 = � C� z m 12 14 16 18 20 22 24 26 28 30 30"Anchor Detail 1D FASTENER SPECIFICATIONS FOR CONSTRUCTION IN THE STATE OF FLORIDA PREPARED FOR: CAROLINA CARPORTS, INC. P.O. BOX 1263 DOBSON, NORTH CAROLINA 27017 PREPARED BY: BECHTOL ENGINEERING AND TESTING, INC. 605 WEST NEW YORK AVENUE DELAND, FLORIDA 32720 Certificate of Authorization No. 00005492 48" Anchor Detail 1C 60" Anchor Detail 1C DETAILS 1 C AND 1 D SHOWN ON SHEET 4 OF 6 NOTES: 1. DOORS AND WINDOWS SHOWN MAY BE SUBSTITUTED FOR DIFFERENT PRODUCT LINES AND/OR MODELS, PROVIDED THE FOLLOWING CONDITIONS ARE MET: PENDING A. PRODUCT SHALL HAVE A VALID FBC PRODUCT APPROVAL. B. COMPONENTS ARE INSTALLED ACCORDING TO MANUFACTURER'S INSTALLATION REQURIEMENTS. MAXIMUM POST SPACING FOR DUTCH LAP IS 4.0' 2. FRAMING CONNECTIONS FOR DOOR AND WINDOW FRAMES REMAIN THE SAME FOR SUBSTITUTED PRODUCTS. HEADERS AND WINDOW RAILS MAY BE RAISED OR LOWERED AS NECESSARY TO ACCOMODATE SUBSTITUTED PRODUCT. GENERAL NOTES: 1 THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET -BACKS, FINISH FLOOR ELEVATION AND SLOPE, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS. 2. THESE STRUCTURES ARE DESIGNED AS NON -HABITABLE UTILITY/STORAGE BUILDINGS (RISK CATEGORY 1) CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS, OR OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS LIST (THIS SHEET), AND NOT PROVIDED AND INSTALLED BY CAROLINA CARPORTS, INC., WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT THE OWNER'S RISK. BECHTOL ENGINEERING AND TESTING, INC., SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS. 3, ALL STEEL TUBING SHALL BE 50 KSI GALVANIZED STEEL. ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL. 4. ALL COMPONENTS AND CLADDING SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND SHALL MEET THE DESIGN PRESSURES REQUIRED BY THE FLORIDA BUILDING CODE (FBC) AT THE LOCATION OF THE BUILDING WITHIN THE STATE OF FLORIDA. 5. ALL FIELD FRAMING CONNECTIONS SHALL BE #12-14 x 3/4" SELF DRILLING SCREWS WITHOUT CONTROL SEAL WASHER. ALL SHOP FRAMING CONNECTIONS SHALL BE WELDED. 6. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS. THE REINFORCING STEEL SHALL BE MINIMUM GRADE 40. CONCRETE SLAB FOUNDATIONS SHALL BE REINFORCED WITH 6X6-W1 AXW1 .4 WELDED WIRE FABRIC COMPLYING WITH ASTM A 185, OR WITH SYNTHETIC FIBER REINFORCEMENT COMPLYING WITH ASTM C1116. 7. BASE RAIL GROUND ANCHOR REQUIREMENTS: ONE WITHIN 6" OF EVERY POST LOCATION, AND BOTH SIDES OF OPENINGS WHERE BASE RAIL IS ABSENT. GROUND ANCHORS ARE NOT REQUIRED FOR CONCRETE FOOTING AND/OR CONCRETE SLAB CONSTRUCTION. SEE GROUND ANCHOR SCHEDULE (THIS SHEET) FOR SPECIFIC TYPE GROUND ANCHOR REQUIREMENTS. 8. CONCRETE ANCHORS SHALL BE TAPCON REDHEAD LDT 1/2" x 5" OR EQUIVALENT OR WEJ-IT ANKR-TITE MODEL AT1252, OR SLEEVE ANCHOR MODEL HSA 1260, OR EQUIVALENT. 9. POST/RAFTER BRACING: BRACE ON EVERY POST/RAFTER CONNECTION, EXCEPT FOR END WALLS. 10. SLAB FOUNDATION SUBGRADE SOILS SHALL BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDER PER SECTION R318.1 OF THE FBC SEVENTH EDITION (2020) - RESIDENTIAL, AND SECTION 1816.1 OF THE FBC SEVENTH EDITION (2020) - BUILDING. MINIMUM ALLOWABLE FOUNDATION SOIL CONTACT BEARING PRESSURE OF 2,000 PSF IS ASSUMED. 11. 14 GA FRAMING: 2-1/2" x 2-1/2" TUBE STEEL (TS) WITH 2-1/4" x 2-1/4" TS NIPPLES. 12 GA FRAMING: 2-1/4" x 2-1/4" TS WITH 2" x 2" TS NIPPLES. 12. ENCLOSED AREAS REQUIRING FLOOD OPENINGS MUST HAVE A MINIMUM OF TWO (2) OPENINGS ON EXTERIOR WALLS. OPENINGS SHOULD BE INSTALLED ON AT LEAST TWO (2) SIDES OF ENCLOSED AREA, WITH BASE OF OPENINGS SET WITHIN 1-FOOT OF THE HIGHER OF INTERIOR OR EXTERIOR GRADE. REQUIRED TOTAL NUMBER OF FLOOD VENTS NOTED IN THE FBC APPROVED PRODUCTS LIST SHALL BE BASED ON ONE (1) FLOOD VENT PER EVERY 305 SQUARE FEET OF ENCLOSED AREA. SEE TYPICAL FLOOD VENT FRAMING PLAN, SHEET 5 OF 6. THIS IS TO CERTIFY THAT THE CALCULATIONS AND SPECIFICATIONS HEREIN HAVE BEEN PREPARED BY THE UNDERSIGNED PROFESSIONAL ENGINEER, AND ARE IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION 1609 OF THE FLORIDA BUILDING CODE, SEVENTH EDITION (2020). BECHTOL ENGINEERING AND TESTING, INC. 605 WEST NEW YORK AVENUE DELAND, FLORIDA 32720 Thomas Digitally signed by Thomas Bechtol Bechtol Date: 2021.01.12 08:54:46 05'00' Thomas Bechtol, P.E. President / Principal Engineer Thomas Bechtol, P.E., State of Florida, Professional Engineer, License No. 38538 This item has been digitally signed and sealed by Thomas R. Bectltol, P.E. on the date indicated here. Pdnted copies of this document are not considemd signed and sealed, and the signature must be verified on any electronic Copes. CAROLINA CARPORTS, INC. GENERIC PLANS FOR USE IN THE STATE OF FLORIDA 01/05/2021 BECHTOL ENGINEERING mkb SCALE. NITS or AND TESTING, Inc. ' tb G21001 CONSULTING GEOTECHNICAL, ENVIRONMENTAL, AND MATERIALS TESTING ENGINEFRS C"��"aA"�,°"�'M"N".aaO- ..L' TB SHEET 1 OF 6