Loading...
HomeMy WebLinkAboutAPPROVED CAROLINA CARPORT GENERIC 2020FBC - ESS page 52"x2"x2" 16 GA ANGLE CLIP SECURE TO POST AND RAFTER WITH (4) #12-14 x 3/4" SDF's, (2) ON BOTTOM, (2) ON SIDE OR 2"x4" 16 GA PLATE SECURE TO EACH SIDE OF TS END POST POST/RAFTER CONNECTION WITH (4) #12-14 x 3/4" SDF's, A (2) ON POST, (2) ON RAFTER EcP/RAFTER CONN. DETAIL �� 1-1/2" x 1-1/2" x 2" 16 GA \ CLIP ANGLE SECURE TO RAFTER POST AND GABLE RAIL WITH (4) #12-14 x 3/4" SDF's (2) ON TOP, (2) ON SIDE RAFTER POST 1-1/2" x 1-1/2" x 2" 16 GA CLIP ANGLE SECURE TO RAFTER AND GABLE RAIL WITH (4) #12-14 x 3/4" SDF's, (2) ON TOP, (2) ON BOTTOM GABLE RAIL GABLE RAIL TO RAFTER POST CONNECTION DETAIL I IAA Not To Scale 2-1/4" FOR 12 GA FRAMING 2-1/2" FOR 14 GA FRAMING 16 GAUGE U-CHANNEL BRACE FASTENED TO THE POST AND RAFTER WITH (2) #12-14 x 3/4" SDF'S AT EACH END (4 PER BRACE) BRACE SECTION Not To Scale NIPPLE TO DBL. HDR. 5 NIPPLE EACH WITH x 3/4" -LING FASTENERS GA TS POST RAFTER POST/DBL. HEADER DETAIL Not To Scale 1-1/2" x 1-1/2" x 2" 16 GA CLIP ANGLE SECURE TO RAFTER POST AND GABLE RAIL WITH (4) #12-14 x 3/4" SI TOP AND BOTTOM i 1-1/2" x 1-1/2" x 2" 16 GA CLIP ANGLE SECURE TO RAFTER AND GABLE RAIL WITH (4) #12-14 x 3/4" SDF's, (2) ON TOP, (2) ON BOTTOM —6" LONG TS NIPPLE SECURE RAFTER AND POST TS GABLE RAIL TO NIPPLE WITH (4) #12-14 x 3/4" SELF -DRILLING FASTENERS TS RAFTER POST GABLE RAIL TO RAFTER POST ^^o CONNECTION DETAIL I I o Not To Scale 1-1/2" 18 GAUGE FURRING CHANNEL FASTENED TO EACH RAFTER WITH (2) #12-14 x 3/4" SDF SPACED NOT MORE THAN 48" O.C. 26 GA. METAL ROOF PANEL TS RAFTER ROOF PANEL ATTACHMENT (ALTERNATE FOR VERTICAL ROOF PANELS) Not To Scale FTER POST VG TS NIPPLE RE WITH (4) #12-14 x 3/4" DRILLING FASTENERS DOUBLE TS HEADER NIPPLE TO DBL. HDR. RAFTER POST/HEADER DETAIL Not To Scale RAFTER TO X 3/16" RAFTER � TS RAFTER 12" LONG TS NIPPLE. SECURE POST TO NIPPLE WITH (4) #12-14 x 3/4" SDF's, 24" 16 GA U-CHANNEL BRACE (5' TO 7' POST) 48" 16 GA U-CHANNEL BRACE (8' TO 14' POST) BRACE ANGLE SHALL BE MIN. 45o TO MAX. 60° FROM HORIZONTAL TS LEG TS TS BAS 6" LONG TS NIPPLE SECURE WITH (4) #12-14 x 3/4" SDF's TS RAFTER POST SIDE EXTENSION RAFTER/POST DETAIL 1 Not To Scale TYPICAL FLOOD VENT FRAMING PLAN NOT TO SCALE SEE GENERAL NOTE No. 12, SHEET 1 OF 6. 6" LONG TS NIPPLE SECURE EACH WITH (4) #12-14 x 3/4" SELF -DRILLING FASTENERS 12 GA TS POST TS BASE RAIL 3/16" NIPPLETO BASE RAIL RAFTER POST/BASE BASE RAIL CONNECTION DETAIL Not To Scale TS RAFTER POST 2"x4" 16 GA PLATE (ONE REQUIRED) SECURE TO EITHER SIDE OF POST/RAFTER CONNECTION WITH (4) #12-14 x 3/4" SDF's, (2) ON POST, (2) ON RAFTER TS LEAN-TO RAFTER 2"x2"x2" 16 GA ANGLE CLIP SECURE TO POST AND RAFTER WITH (4) #12-14 x 3/4" SDF's, (2) ON RAFTER, (2) ON POST IS/ LEAN-TO RAFTER CONN. DETAIL Not To Scale BECHTOL ENGINEERING AND TESTING, INC. 605 WEST NEW YORK AVENUE DELAND, FLORIDA 32720 Thomas Digitally signed by Thomas Bechtol Bechtol Date: 2021.01.12 09:06:30 05'00' Thomas Bechtol, P.E. President / Principal Engineer Thomas Bechtol, P.E., State of Florida, Professional Engineer, License No. 38538 This item has been digitally signed and sealed by Thomas R. Bechtol, P.E. on the date indicated here. Printed copies of this document are not considered signed and sealed, and the signature must be vedfled on any electronic copies.