HomeMy WebLinkAboutAPPROVED CAROLINA CARPORT GENERIC 2020FBC - ESS page 52"x2"x2" 16 GA ANGLE CLIP
SECURE TO POST AND
RAFTER WITH (4) #12-14 x 3/4"
SDF's, (2) ON BOTTOM,
(2) ON SIDE
OR
2"x4" 16 GA PLATE
SECURE TO EACH SIDE OF
TS END POST POST/RAFTER CONNECTION
WITH (4) #12-14 x 3/4" SDF's,
A (2) ON POST, (2) ON RAFTER
EcP/RAFTER CONN. DETAIL
��
1-1/2" x 1-1/2" x 2" 16 GA \
CLIP ANGLE SECURE TO
RAFTER POST AND GABLE
RAIL WITH (4) #12-14 x 3/4" SDF's
(2) ON TOP, (2) ON SIDE
RAFTER POST
1-1/2" x 1-1/2" x 2" 16 GA CLIP
ANGLE SECURE TO RAFTER
AND GABLE RAIL WITH (4)
#12-14 x 3/4" SDF's, (2) ON TOP,
(2) ON BOTTOM
GABLE RAIL
GABLE RAIL TO RAFTER POST
CONNECTION DETAIL
I IAA Not To Scale
2-1/4" FOR
12 GA FRAMING
2-1/2" FOR
14 GA FRAMING
16 GAUGE U-CHANNEL BRACE
FASTENED TO THE POST AND
RAFTER WITH (2) #12-14 x 3/4" SDF'S
AT EACH END (4 PER BRACE)
BRACE SECTION
Not To Scale
NIPPLE TO
DBL. HDR.
5 NIPPLE
EACH WITH
x 3/4"
-LING FASTENERS
GA TS POST
RAFTER POST/DBL. HEADER DETAIL
Not To Scale
1-1/2" x 1-1/2" x 2" 16 GA CLIP ANGLE
SECURE TO RAFTER POST AND
GABLE RAIL WITH (4) #12-14 x 3/4" SI
TOP AND BOTTOM i
1-1/2" x 1-1/2" x 2" 16 GA CLIP ANGLE
SECURE TO RAFTER AND GABLE
RAIL WITH (4) #12-14 x 3/4" SDF's,
(2) ON TOP, (2) ON BOTTOM
—6" LONG TS NIPPLE
SECURE RAFTER AND POST TS GABLE RAIL
TO NIPPLE WITH (4) #12-14 x 3/4"
SELF -DRILLING FASTENERS
TS RAFTER POST
GABLE RAIL TO RAFTER POST
^^o CONNECTION DETAIL
I I o Not To Scale
1-1/2" 18 GAUGE FURRING CHANNEL FASTENED
TO EACH RAFTER WITH (2) #12-14 x 3/4" SDF
SPACED NOT MORE THAN 48" O.C.
26 GA. METAL ROOF
PANEL
TS RAFTER
ROOF PANEL ATTACHMENT
(ALTERNATE FOR VERTICAL ROOF PANELS)
Not To Scale
FTER POST
VG TS NIPPLE
RE WITH (4) #12-14 x 3/4"
DRILLING FASTENERS
DOUBLE TS HEADER
NIPPLE TO
DBL. HDR.
RAFTER POST/HEADER DETAIL
Not To Scale
RAFTER
TO X 3/16"
RAFTER �
TS RAFTER 12" LONG TS NIPPLE.
SECURE POST TO NIPPLE
WITH (4) #12-14 x 3/4" SDF's,
24" 16 GA U-CHANNEL BRACE (5' TO 7' POST)
48" 16 GA U-CHANNEL BRACE (8' TO 14' POST)
BRACE ANGLE SHALL BE MIN. 45o
TO MAX. 60° FROM HORIZONTAL
TS LEG
TS
TS BAS
6" LONG TS NIPPLE
SECURE WITH (4) #12-14 x 3/4" SDF's
TS RAFTER POST
SIDE EXTENSION
RAFTER/POST DETAIL
1 Not To Scale
TYPICAL FLOOD
VENT FRAMING PLAN
NOT TO SCALE
SEE GENERAL NOTE No. 12, SHEET 1 OF 6.
6" LONG TS NIPPLE
SECURE EACH WITH (4) #12-14 x 3/4"
SELF -DRILLING FASTENERS
12 GA TS POST
TS BASE RAIL
3/16" NIPPLETO
BASE RAIL
RAFTER POST/BASE
BASE RAIL CONNECTION DETAIL
Not To Scale
TS RAFTER POST
2"x4" 16 GA PLATE (ONE REQUIRED)
SECURE TO EITHER SIDE OF
POST/RAFTER CONNECTION
WITH (4) #12-14 x 3/4" SDF's,
(2) ON POST, (2) ON RAFTER
TS LEAN-TO RAFTER
2"x2"x2" 16 GA ANGLE CLIP
SECURE TO POST AND
RAFTER WITH (4) #12-14 x 3/4"
SDF's, (2) ON RAFTER,
(2) ON POST
IS/ LEAN-TO RAFTER CONN. DETAIL
Not To Scale
BECHTOL ENGINEERING AND TESTING, INC.
605 WEST NEW YORK AVENUE
DELAND, FLORIDA 32720
Thomas Digitally signed by Thomas
Bechtol
Bechtol Date: 2021.01.12 09:06:30
05'00'
Thomas Bechtol, P.E.
President / Principal Engineer
Thomas Bechtol, P.E., State of Florida, Professional Engineer, License No. 38538
This item has been digitally signed and sealed by Thomas R. Bechtol, P.E.
on the date indicated here. Printed copies of this document are not considered
signed and sealed, and the signature must be vedfled on any electronic copies.