Loading...
HomeMy WebLinkAboutAPPROVED KORNILOFF DIGITAL WINDLOAD7_16_C&C _HVHZ_TallBuildings_Temp.xls 1 of 3 Contractor Statewide Windows and Doors 3725 Investment Lane, West Palm Beach, FL 33404 Specialty Engineering Consultants, Inc 1599 SW 30 Ave. #20 Boynton Beach, FL 33426 D. Adam LeBlanc, PE #77012 FL CA# 0009217 Mark Type W H 1 SH 30.75 50.75 2 SH 35.75 62.375 3 SH 35.75 62.375 4 SGD 105 95.75 5 SGD 141.88 95.75 6 AL. Mull (1x4)35.75 62.375 9940 S. Ocean Drive #703, Jensen Beach, FL 34957 Korniloff Residence 3/11/2021 Change out: 3 Windows and 2 Doors no size modifications 7_16_C&C _HVHZ_TallBuildings_Temp.xls 2 of 3 Specialty Engineering Consultants, Inc 1599 SW 30 Ave. #20 Boynton Beach, FL 33426 D. Adam LeBlanc, PE #77012 FL CA# 0009217 Home Owner:Contractor :Statewide Windows and Doors Address:3725 Investment Lane, Location:West Palm Beach, FL 33404 Date:3/11/2021 (+) psf (-) psf (+) psf (-) psf 1 SH 30.75 50.75 y FL 22250.1 60 80 55.7 60.1 n y Dining Room 2 SH 35.75 62.375 y FL 22250.1 60 80 55.7 60.1 n y Bedroom 1 3 SH 35.75 62.375 y FL 22250.1 60 80 55.7 60.1 n y Bedroom 1 4 SGD 105.95.75 y 20-1118.06 60 60 55.2 59.9 n y Master Bedroom 5 SGD 141.875 95.75 y 20-1118.06 60 60 55.1 59.8 n y Living Room 6 AL. Mull (1x4)35.75 62.375 y 20-0814.10 125.2 125.2 55.7 60.1 n y Bedroom 1 - Vertical Between Marks 2 and 3 1 2 3 4 5 6 Jensen Beach, FL 34957 Product Approval #Window/Door SGD, mull We have attempted to accurately depict the field conditions based on information submitted by others. This information may be lacking but we respectfully submit that this does not impact our calculations. If there is a substantial difference, then notify this engineer for a revised plan/calculations. Allowable pressure see NOA Wind design pressures are calculated in accordance with, Florida Building Code 2020, ASCE 7-16, Method 2, see attached calculations. All door and window frames to be attached through wood bucks per NOA specifications. Quantity and spacing of fasteners shall be in accordance with the NOA and/or manufacturer's specifications. Shutters are not required in accordance with the "Existing Building Florida Building Code" section 707.4, "area replaced is less than 25% of total aggregate area". Comments Replace existing doors or windows as designated with new doors w/ current Miami-Dade product approval or State of Florida product approval No change in rough opening size(s) were made. The existing opening is not to be modified. 9940 S. Ocean Drive #703, Korniloff Residence NOTES Window/door replaced? (y/n) Shutter required? (y/n) Req'd Wind Pressure, see calc'sMARK Product rated for impact? (y/n) HEIGHT (in) WIDTH (in) Specialty Engineering Consultants, Inc. 7_16_C&C _HVHZ_TallBuildings_Temp.xls 3 of 3 Specialty Engineering Consultants, Inc 1599 SW 30 Ave. #20 Boynton Beach, FL 33426 D. Adam LeBlanc, PE #77012 FL CA# 0009217 Home Owner Korniloff Residence Address 9940 S. Ocean Drive #703, Location Jensen Beach, FL 34957 Date 3/11/2021 Opening Mark width (in)height (in) Effective Area of component (ft^2) GCp (positive, 4&5) GCp (negative, 4) GCp (negative, 5) P positive P negative P positive P negative 1 30.75 50.75 10.8 0.900 -0.900 -1.800 55.7 -60.1 2 35.75 62.38 15.5 0.900 -0.900 -1.800 55.7 -60.1 3 35.75 62.38 15.5 0.900 -0.900 -1.800 55.7 -60.1 4 35.00 95.75 23.3 0.889 -0.896 -1.784 55.2 -59.9 5 35.47 95.75 23.6 0.888 -0.896 -1.782 55.1 -59.8 6 35.75 62.38 15.5 0.900 -0.900 -1.800 55.7 -60.1 V (mph)170 1620 FBC for HVHZ, or Fig. 26.5-1b 1.0 Building Category II Table 1.5-1, page 4 Exposure D Section 26.7 Length of Building (ft)66 Width of Building (ft)265 Mean Roof height (ft)118 Kz(h)1.47 Table 26.10-1, page 268 Kd 0.85 Table 26.6-1, page 266 Kzt 1 Figure 26.8-1, page 268 pitch of roof 0/12 theta 0.0 degrees 1.0 Reduction factor for slope of roof qh (psf)92.74 Velocity Wind Pressure @ mean roof height GCpi 0.18 -0.18 0.55 -0.55 See Table 26.13-1, page 271 a1 26.50 10% of width 1 a2 6.60 10% of width 2 a3 47.2 0.4*mean roof height a 6.60 End Zone distance z (ft)70 Zone 4 Unbreached Zone 5 Unbreached Component and Cladding Pressures, Wall and/or Window components in accordance with ASCE 7-16 w/ mean roof height > 60 ft 0.0 degrees Loads specified are for Allowable Stress - 0.6*W(ult) 2.4.1 #7 (0.6D+0.6W) Specialty Engineering Consultants, Inc. p q G C.p⋅( ) ⋅q.i G C.pi⋅( ) ⋅−:=