HomeMy WebLinkAbout20-3182 (XL Autoparts), Dtls, (E-Signed 2-17-2021 MB)ENGINEERDESIGNED PER SECTION 2209 OF THE 2020 FBCFa = 1.6 & Ss = 0.05CODE USED IN DESIGNINSTALLATION OF STORAGE RACKSIN AN EXISTING BUILDINGSCOPE OF WORKTABLE OF CONTENTS 1. DRAWING No. 20-3182 TABLE OF CONTENTS 2. DRAWING No. S-1 OF 3 (FOR REFERENCE ONLY) SITE PLAN 3. DRAWING No. 20-3182-1 EGRESS PLAN 3RD LEVEL & 2ND LEVEL 4. DRAWING No. 20-3182-2 EGRESS PLAN GROUND LEVEL 5. DRAWING No. 20-3182-A STORAGE RACK DETAILS 6. DRAWING No. 20-3182-B STORAGE RACK DETAILS 7. DRAWING No. 20-3182-C LIGHT DUTY SHELVING CATWALK DETAILSSCHEDULE OF DOCUMENTSINSTALLATION OF STORAGE RACKS3053 INDUSTRIAL 31ST ST.FORT PIERCE, FL 34946XL AUTOPARTSBUILDING DATAPROJECT CONTACTBLDG SQ FT: 180,000CONSTRUCTION TYPE: II-BOCCUPANCY TYPE: B, S-1FULLY SPRINKLERED: YESSPRINKLER HEAD TYPE: PENDANT, 200 DEGREE F QUICKRESPONSE THROUGHOUT (UNLESS OTHERWISE NOTED)DENSITY: .20 GPM / SQ. FTK-FACTOR: 8.0SPRINKLER SYSTEM PERMIT NUMBER: AFS-21-08COMMODITIES: CLASS II AUTOMOTIVE AFTER-PARTSSTORED IN PLASTIC BAGS, RETAIL CARTONS,CORRUGATED CARDBOARD CARTONS, PLASTICAND/OR METAL DRUMS. SOME ITEMS MAY BESTORED IN PLASTIC TOTES AND/OR PLASTIC ORCARDBOARD BINS.OWNERADDRESS:DRAWING NUMBER:DESCRIPTION:DRAWN BY:DATE:LAST REV. BY:REV. DATE:APRV'D BY: SAL E. FATEENTYPE:DATEREV.BY DESCRIPTIONSCALE:N.T.S.SUBMITTALSERVICES1130 E. Cypress St.Covina, CA 91724909.869.0989XL AUTOPARTS 3053 INDUSTRIAL 31ST ST. FORT PIERCE, FL 34946 D.D.12/22/20TABLEOFCONTENTS20-3182PROJECT SQ FT: 20,000SAL FATEENSEIZMIC ENGINEERING, INC.1130 E. CYPRESS STREETCOVINA, CA. 91724TEL: (909) 869-0989KARI GRANGERPERMIT COORDINATORSUBMITTAL SERVICES, INC.1130 E. CYPRESS STREETCOVINA, CA. 91724TEL: (858) 239-3975KGRANGER@SEIZMICINC.COMDARRIN HERVIEUXTHE PARTS HOUSEDARRIN.HERVIEUX@XLPARTS.COMTEL: (570) 575-2390S ALFATEENPROFESSIONALENG INEER LI CENSEFLORIDASTATEOFNo.7259202-28-2021EXPIRES 22 23 24 9'-978" 79'-4" 80'-0" 75'-2" A2 B2 C2 D2 23 24 9'-978" 79'-4" 80'-0" 75'-2" A3 B3 C3 D3 E3 2526272829303132 23'-3"25'-0"25'-0"25'-0"25'-0"25'-0"25'-1"25'-0" 2526272829303132 23'-3"25'-0"25'-0"25'-0"25'-0"25'-0"25'-1"25'-0" EGRESS LEGEND PATH TRAVEL DIST. A3 82 FT. - DENOTES PATH OF TRAVEL EGRESS PATHS AS INDICATED PROVIDE A MINIMUM CLEAR WIDTH OF 36 INCHES & MINIMUM CLEAR HEIGHT OF 80 INCHES B3 77 FT. C3 77 FT. D3 103 FT. E3 103 FT. PATH TRAVEL DIST. B2 45 FT. C2 D2 C2 D2 PATH TRAVEL DIST. B1 80 FT. C1 155 FT. D1 145 FT. C1 155 FT. D1 145 FT. 45 FT. 45 FT. 45 FT. 45 FT. + + + + + + + + + += = = = = TOTAL 207 FT. 277 FT. 267 FT. 303 FT. 293 FT. EGRESS LEGEND PATH TRAVEL DIST. A2 45 FT. - DENOTES PATH OF TRAVEL EGRESS PATHS AS INDICATED PROVIDE A MINIMUM CLEAR WIDTH OF 36 INCHES & MINIMUM CLEAR HEIGHT OF 80 INCHES B2 45 FT. C2 45 FT. D2 45 FT.ADDRESS:DRAWING NUMBER: DESCRIPTION: DRAWN BY: DATE: LAST REV. BY: REV. DATE: APRV'D BY: SAL E. FATEEN TYPE:DATEREV.BYDESCRIPTIONSCALE:N.T.S. Tel.(909)869-0989 Covina, California EST. 1985 ENGINEERING, INC. 1130 E. Cypress St. SEIZMIC 91724 SEIZMICXL AUTOPARTS3053 INDUSTRIAL 31ST. STREETFORT PIERCE, FL 34946M.V. / T.C. 12/15/20 EGRESS PLAN 3RD LEVEL & 2ND LEVEL 20-3182-1 S A L F ATEE N PROF E SSIONA L E N GINEERL IC E NS E FLOR I D A STATE OF No.72592 02-28-2021 EXPIRES 3 3RD LEVEL TO 2ND LEVEL EGRESS PLAN 2 2ND LEVEL TO GROUND LEVEL EGRESS PLAN Training Offices 22 23 24 2526272829303132 9'-978" 24 23'-3"25'-0"25'-0"25'-0"25'-0"25'-0"25'-1"25'-0" 79'-4" 80'-0" 75'-2" 80'-0" EXIT A1 B1 C1 D1 EMERGENCY LIFT GATES EMERGENCY LIFT GATES TUNNEL BAY EGRESS LEGEND PATH TRAVEL DIST. A1 90 FT. - DENOTES PATH OF TRAVEL EGRESS PATHS AS INDICATED PROVIDE A MINIMUM CLEAR WIDTH OF 36 INCHES & MINIMUM CLEAR HEIGHT OF 80 INCHES B1 80 FT. C1 155 FT. D1 145 FT. - DENOTES ILLUMINATED EXIT SIGN ADDRESS:DRAWING NUMBER: DESCRIPTION: DRAWN BY: DATE: LAST REV. BY: REV. DATE: APRV'D BY: SAL E. FATEEN TYPE:DATEREV.BYDESCRIPTIONSCALE:N.T.S. Tel.(909)869-0989 Covina, California EST. 1985 ENGINEERING, INC. 1130 E. Cypress St. SEIZMIC 91724 SEIZMICXL AUTOPARTS3053 INDUSTRIAL 31ST. STREETFORT PIERCE, FL 34946M.V. / T.C. 12/15/20 EGRESS PLAN GROUND LEVEL 20-3182-2SALFATEE N PROF E SSIONA L E N GINEERL IC E NS E FLOR I D A STATE OF No.72592 02-28-2021 EXPIRES 1 GROUND LEVEL EGRESS PLAN MEANS OF EGRESS NOTES: 1. EXITS AND EXIT ACCESS DOORS SHALL BE MARKED BY AN APPROVED EXIT SIGN READILY VISIBLE FROM ANY DIRECTION OF EGRESS TRAVEL. THE PATH OF EGRESS TRAVEL TO EXITS AND WITHIN EXITS SHALL BE MARKED BY READILY VISIBLE EXIT SIGNS TO CLEARLY INDICATE THE DIRECTION OF EGRESS TRAVEL IN CASES WHERE THE EXIT OR THE PATH OF EGRESS TRAVEL IS NOT IMMEDIATELY VISIBLE TO THE OCCUPANTS. INTERVENING MEANS OF EGRESS DOORS WITHIN EXITS SHALL BE MARKED BY EXIT SIGNS. EXIT SIGN PLACEMENT SHALL BE SUCH THAT NO POINT IN AN EXIT ACCESS CORRIDOR OR EXIT PASSAGEWAY IS MORE THAN 100 FEET OR THE LISTED VIEWING DISTANCE FOR THE SIGN, WHICHEVER IS LESS, FROM THE NEAREST VISIBLE EXIT SIGN. NOTE: EXIT SIGNS ARE NOT REQUIRED IN ROOMS OR AREAS THAT REQUIRE ONLY ONE EXIT OR EXIT ACCESS. 2. EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. 3. TWO EXITS OR EXIT ACCESS DOORWAYS FROM ANY SPACE SHALL BE PROVIDED WHERE THE OCCUPANT LOAD OF THE SPACE EXCEEDS 29 OCCUPANTS PER IFC TABLE 1006.2.1, OR THE COMMON PATH OF EGRESS TRAVEL EXCEEDS THE VALUES IN IFC TABLE 1017.2. 4. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, SHALL BE ILLUMINATED AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT-CANDLE AT THE WALKING SURFACE LEVEL. 5. THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL NORMALLY BE PROVIDED BY THE PREMISES' ELECTRICAL SUPPLY. IN THE EVENT OF POWER SUPPLY FAILURE, AN EMERGENCY ELECTRICAL SYSTEM SHALL AUTOMATICALLY ILLUMINATE AISLES AND UNENCLOSED EGRESS STAIRWAYS IN SPACES THAT REQUIRE TWO OR MORE MEANS OF EGRESS AS DEFINED. 6. THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A DURATION OF NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF STORAGE BATTERIES, UNIT EQUIPMENT OR AN ON-SITE GENERATOR. THE INSTALLATION OF THE EMERGENCY POWER SYSTEM SHALL BE IN ACCORDANCE WITH SECTION 2702. 7. EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS AT LEAST AN AVERAGE OF 1 FOOTCANDLE AND A MINIMUM AT ANY POINT OF 0.1 FOOTCANDLE MEASURED ALONG THE PATH OF EGRESS AT FLOOR LEVEL. ILLUMINATION LEVELS SHALL BE PERMITTED TO DECLINE TO 0.6 FOOTCANDLE AVERAGE AND A MINIMUM AT ANY POINT OF 0.06 FOOTCANDLE AT THE END OF THE EMERGENCY LIGHTING TIME DURATION. A MAXIMUM-TO-MINIMUM ILLUMINATION UNIFORMITY RATIO OF 40 TO 1 SHALL NOT BE EXCEEDED. 8. EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. WHEN THE FACE OF AN EXIT SIGN IS ILLUMINATED FROM AN EXTERNAL SOURCE, IT SHALL HAVE AN INTENSITY OF NOT LESS THAN 5 FOOT-CANDLES. INTERNALLY ILLUMINATED SIGNS SHALL BE LISTED AND LABELED AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND IFC CHAPTER 27. EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. 3" APPROX. 3" APPROX. 4 4 1/8"TYP.7/8" 4 1 3" 5" 1/8" THK.3/4" 3/4" 2 3" 3" 14 GA. 1/8" 1/8"TYP. 1 TYP.Ø9/16" SOIL 2 1 (1) ANCHOR REQ'D PER BASE PLATE SLAB ON GRADE 1/2"Ø ANCHOR 3 5/8" NOMINAL EMBED. 1 1/2" 16 GA.1" 3" 3" 3" 3" 14 GA 14 GA 14 GA 3" 8 1/4" 3" 7 GA. 1 5/16"1 7/8" 5" 7/8" 1 11/16" 16 GA. 1/8"TYP. TYP.1/8" 5B 2 3/4" 6 3" 8 1/4" 3" 7 GA. 1 5/16"1 7/8" 3" 7/8" 1 11/16" 16 GA. 1/8"TYP. TYP.1/8" 5A 2 3/4" 6 3" TYP.6 5 1 35" 35" 41" 35" 35" 264" 144" FRONT VIEW TYPE 50"W x 207"H W/ 144" BEAMS 35" 35" 41" 35" 35" 264" 126" FRONT VIEW TYPE 50"W x 207"H W/ 126" BEAMS 35" 35" 41" 35" 35" 264" 96" FRONT VIEW TYPE 50"W x 207"H W/ 96" BEAMS 35" 35" 41" 35" 35" 264" 109" FRONT VIEW TYPE 50"W x 207"H W/ 109" BEAMS 111" 96" 264" 180" FRONT VIEW TYPE 32"W x 207"H W/ 180" BEAMS 111" 96" 264" 180" FRONT VIEW TYPE 50"W x 207"H W/ 180" BEAMS 5C 5A 5C 5A 5C 5A 5C 5A 9" 42" 50" 50" 50" 264" 50" SIDE VIEW 111" TOP OF DECK 35" 35" 41" 35" 35" 264" 56" FRONT VIEW TYPE 50"W x 264"H W/ 56" BEAMS 99" TOP OF DECK 5B 5A 5B 5A 50" 27" 28" 28" 5A 35" 35" 41" 35" 35" 264" 93" FRONT VIEW TYPE 50"W x 264"H W/ 93" BEAMS 5B 5A 5B 5A 27" 28" 28" 5A 5D 5D 5D 5D 9" 42" 50" 50" 50" 264" 50" SIDE VIEW 111" TOP OF DECK 99" TOP OF DECK 50" 27" 28" 28" 5A 5A 5C 27" 28" 28" 5A 5A 5C 27" 28" 28" 5A 5A 5C 27" 28" 28" 5A 5A 5C 9" 42" 50" 50" 50" 264" 32" SIDE VIEW 111" TOP OF DECK 99" TOP OF DECK 50" V-A 1 5 2 3 4 6 V-B 9 7 3" 8 1/4" 3" 7 GA. 1 5/16"1 7/8" 5 1/2" 7/8" 1 11/16" 16 GA. 1/8"TYP. TYP.1/8" 5C 2 3/4" 6 V-A TYPICAL BRACE TO COLUMN CONNECTION 1 COLUMN 2 BASE PLATE 3 ANCHOR 4 HORIZONTAL & DIAGONAL BRACE V-B TYPICAL BEAM TO COLUMN CONNECTION 5A BEAM 6 CONNECTOR STORAGE RACK ELEVATIONS GENERAL CONFIGURATION 5B BEAM 6 CONNECTOR 5C BEAM 6 CONNECTOR ADDRESS:DRAWING NUMBER: DESCRIPTION: DRAWN BY: DATE: LAST REV. BY: REV. DATE: APRV'D BY: SAL E. FATEEN TYPE:DATEREV.BYDESCRIPTIONSCALE:N.T.S. Tel.(909)869-0989 Covina, California EST. 1985 ENGINEERING, INC. 1130 E. Cypress St. SEIZMIC 91724 SEIZMICXL AUTOPARTS3053 INDUSTRIAL 31ST. STREETFORT PIERCE, FL 34946M.V. / T.C. 12/15/20 REP STORAGE RACK DETAILS 20-3182-ASALFATEE N PROF E SSIONA L E N GINEERL IC E NS E FLO R I D A STATE OF No.72592 02-28-2021 EXPIRES NOTES: 1. DESIGNED PER SECTION 2209 OF THE 2018 / 2020 FBC. Fa = 1.6 & Ss = 0.05 SEISMIC DESIGN CATEGORY: A. 2. STORAGE CAPACITY: 1,200# PER LEVEL. 3. STEEL: ASTM A1011 FOR SHAPE Fy = 55,000 PSI GRADE 55. 4. ALL BOLTS: A307 (UNLESS OTHERWISE NOTED). 5. ANCHORS: HILTI KWIK BOLT TZ. 6. ANCHORS SHALL BE INSTALLED PER ICC #ESR-1917. 7. CONCRETE: 6" THICK x 4,000 PSI. 8. MODULUS OF SUB-GRADE REACTION: 50 PCI. (DISTURBED SOIL: 500 PSF) 9. THE MAXIMUM TOP TO BOTTOM OUT-OF-PLUMB RATIO AND OUT-OF- STRAIGHT RATIO RACK COLUMN IS 1/240 (FOR EXAMPLE 1/2" PER 10 FEET OF HEIGHT). COLUMN WHOSE OUT-OF-PLUMB RATIO OR OUT- OF-STRAIGHT RATIO EXCEEDS THIS LIMIT SHALL BE UNLOADED AND RE-PLUMBED. ANY DAMAGED PARTS MUST BE REPAIRED OR REPLACED. 10. THE OWNER SHALL MAINTAIN THE STRUCTURAL INTEGRITY OF THE RACK SYSTEM BY ASSURING PROPER OPERATIONAL, HOUSE KEEPING, AND MAINTENANCE PROCEDURES, BUT NOT LIMITED TO, THE FOLLOWING: A) PROHIBIT ANY OVER LOADING OF ANY PALLET POSITIONS AND OF THE OVERALL RACK SYSTEM. B) REGULARLY INSPECT FOR DAMAGE. IF DAMAGE IS FOUND, IMMEDIATELY UNLOAD THE AFFECTED AREA AND REPLACE OR REPAIR ANY DAMAGED COLUMNS, BEAMS, OR OTHER STRUCTURAL COMPONENTS. C) REQUIRE ALL PALLETS TO BE MAINTAINED IN GOOD, SAFE OPERATING CONDITION. D) ENSURE THAT PALLETS ARE PROPERLY PLACED ONTO PALLET LOAD SUPPORT MEMBERS IN PROPERLY STACKED AND STABLE POSITION. E) REQUIRE THAT ALL GOODS STORED ON EACH PALLET TO BE PROPERLY STACKED AND STABLE. F) PROHIBIT DOUBLE STACKING OF ANY PALLET POSITION, INCLUDING THE TOP MOST POSITION, UNLESS THE RACK SYSTEM IS SPECIFICALLY DESIGNED FOR SUCH LOADING. G) ENSURE THAT THE RACKS ARE NOT MODIFIED OR REARRANGED IN A MANNER NOT WITHIN THE ORIGINAL DESIGN CONFIGURATIONS. 5D BEAM 6 CONNECTOR V-C CATWALK SUPPORT BEAM CONNECTION 4 3" APPROX. 3" APPROX. 4 4 TYP.1 1/4"1/8" 1 5/8" 5/8" Ø9/16" 5" 3" 1/8" THK. 2 13 GA. 3" 1 3" 1/8"TYP.1/8"TYP. SOIL 2 1 (1) ANCHOR REQ'D PER BASE PLATE SLAB ON GRADE 1/2"Ø ANCHOR 3 5/8" NOMINAL EMBED. 1 1/4"16 GA. 3/8" 1 1/2" V-A 1 5 2 3 4 6 V-B 9 7 3" 3" 3" 3" 14 GA 14 GA 14 GA 5" TYP.1/8" 16 GA. 1 3/4" TYP.1/8" 1" 1 5/8" 5 1 5/8" 7 GA. 6 3" 4" 1" 6" 1 5/8" 7 GA. 6 3" 4" 1" 6" 3" TYP.1/8" 16 GA. 1 3/4" TYP.1/8" 1" 1 5/8" 5 5 6 2" TYP. 1 7/16"Ø STUD 111" 96" 264" 180" FRONT VIEW TYPE 37"W x 207"H W/ 180" BEAMS 9" 51" 51" 71" 71" 264" 50" SIDE VIEW 111" TOP OF DECK 35" 35" 41" 35" 35" 264" 56" FRONT VIEW TYPE 50"W x 264"H W/ 56" BEAMS 99" TOP OF DECK 5B 5A 5B 5A 27" 28" 28" 5A 35" 35" 41" 35" 35" 264" 93" FRONT VIEW TYPE 50"W x 264"H W/ 93" BEAMS 5B 5A 5B 5A 27" 28" 28" 5A 5C 5C 9" 51" 51" 71" 71" 37" SIDE VIEW 111" TOP OF DECK 99" TOP OF DECK V-A TYPICAL BRACE TO COLUMN CONNECTION 1 COLUMN 2 BASE PLATE 3 ANCHOR 4 HORIZONTAL & DIAGONAL BRACE V-B TYPICAL BEAM TO COLUMN CONNECTION 5A BEAM 6 CONNECTOR 5B BEAM 6 CONNECTOR STORAGE RACK ELEVATIONS ADDRESS:DRAWING NUMBER: DESCRIPTION: DRAWN BY: DATE: LAST REV. BY: REV. DATE: APRV'D BY: SAL E. FATEEN TYPE:DATEREV.BYDESCRIPTIONSCALE:N.T.S. Tel.(909)869-0989 Covina, California EST. 1985 ENGINEERING, INC. 1130 E. Cypress St. SEIZMIC 91724 SEIZMICXL AUTOPARTS3053 INDUSTRIAL 31ST. STREETFORT PIERCE, FL 34946M.V. / T.C. 12/15/20 INT STORAGE RACK DETAILS 20-3182-BSALFATEE N PROF E S SIONA L E N GINEERL IC E NS E FLO R I D A STATE OF No.72592 02-28-2021 EXPIRES NOTES: 1. DESIGNED PER SECTION 2209 OF THE 2018 IBC / 2020 FBC. Fa = 1.6 & Ss = 0.05 SEISMIC DESIGN CATEGORY: A. 2. STORAGE CAPACITY: 1,200# PER LEVEL. 3. STEEL: ASTM A1011 FOR SHAPE Fy = 55,000 PSI GRADE 55. 4. ALL BOLTS: A307 (UNLESS OTHERWISE NOTED). 5. ANCHORS: HILTI KWIK BOLT TZ. 6. ANCHORS SHALL BE INSTALLED PER ICC #ESR-1917. 7. CONCRETE: 6" THICK x 4,000 PSI. 8. MODULUS OF SUB-GRADE REACTION: 50 PCI. (DISTURBED SOIL: 500 PSF) 9. THE MAXIMUM TOP TO BOTTOM OUT-OF-PLUMB RATIO AND OUT-OF- STRAIGHT RATIO RACK COLUMN IS 1/240 (FOR EXAMPLE 1/2" PER 10 FEET OF HEIGHT). COLUMN WHOSE OUT-OF-PLUMB RATIO OR OUT- OF-STRAIGHT RATIO EXCEEDS THIS LIMIT SHALL BE UNLOADED AND RE-PLUMBED. ANY DAMAGED PARTS MUST BE REPAIRED OR REPLACED. 10. THE OWNER SHALL MAINTAIN THE STRUCTURAL INTEGRITY OF THE RACK SYSTEM BY ASSURING PROPER OPERATIONAL, HOUSE KEEPING, AND MAINTENANCE PROCEDURES, BUT NOT LIMITED TO, THE FOLLOWING: A) PROHIBIT ANY OVER LOADING OF ANY PALLET POSITIONS AND OF THE OVERALL RACK SYSTEM. B) REGULARLY INSPECT FOR DAMAGE. IF DAMAGE IS FOUND, IMMEDIATELY UNLOAD THE AFFECTED AREA AND REPLACE OR REPAIR ANY DAMAGED COLUMNS, BEAMS, OR OTHER STRUCTURAL COMPONENTS. C) REQUIRE ALL PALLETS TO BE MAINTAINED IN GOOD, SAFE OPERATING CONDITION. D) ENSURE THAT PALLETS ARE PROPERLY PLACED ONTO PALLET LOAD SUPPORT MEMBERS IN PROPERLY STACKED AND STABLE POSITION. E) REQUIRE THAT ALL GOODS STORED ON EACH PALLET TO BE PROPERLY STACKED AND STABLE. F) PROHIBIT DOUBLE STACKING OF ANY PALLET POSITION, INCLUDING THE TOP MOST POSITION, UNLESS THE RACK SYSTEM IS SPECIFICALLY DESIGNED FOR SUCH LOADING. G) ENSURE THAT THE RACKS ARE NOT MODIFIED OR REARRANGED IN A MANNER NOT WITHIN THE ORIGINAL DESIGN CONFIGURATIONS. 5C BEAM 6 CONNECTOR V-C CATWALK SUPPORT BEAM CONNECTION GENERAL CONFIGURATION 5/16"Ø TYP. 13 GA. 1 1/2" 3/4" 2 5/8" 3/8" x 7/8" SLOTS TYP. SOIL SLAB ON GRADE 2 1 (1) ANCHOR REQ'D PER BASE PLATE @ PERIMETER COLUMNS 3/8"Ø ANCHOR 2 5/16" NOMINAL EMBED. ATTACH FOOT PLATE TO COLUMN W/ (1) 5/16"Ø BOLT B B A A VARIES VARIES ATTACH W/ (2) 1/4"Ø BOLTS TYP. 1A 1A 1B 1B 77 VARIES VARIES 1" x 13 GA. STRAP ATTACH W/ 1/4"Ø BOLTS 1A 4 5 36" FRONT VIEW TYPE 36" x 18" 265" 18" SIDE VIEW 12" 3" 16" 16" 16" 16" 16" 19" 14" 16" 16" 16" 16" 16" 111" COL. SPLICE 111" COL. SPLICE 16" 16" 16" 111" TOP OF DECK 96" TOP OF DECK 265" 18"36"18"18"48" FRONT VIEW TYPE 48" x 24" 265" 24" SIDE VIEW 12" 3" 16" 16" 16" 16" 16" 19" 14" 16" 16" 16" 16" 16" 16" 16" 16" 265" 24"36"24"24"36" FRONT VIEW TYPE 36" x 24" 265" 12" 3" 16" 16" 16" 16" 16" 19" 14" 16" 16" 16" 16" 16" 16" 16" 16" 43" 111" COL. SPLICE 111" COL. SPLICE 43" 111" COL. SPLICE 111" COL. SPLICE 43" 111" TOP OF DECK 96" TOP OF DECK 3/4" 1/8" 1" 13 GA. 2" 5/8" 2 1/8"1 1/8" SGL. 2 1/4" DBL 1 1/2" 14 GA. 5/16"Ø TYP. 3/8" x 7/8" SLOTS TYP.3 1/2" 2"3/8"3/8" 7/16"Ø HOLES 16 GA. THK.5/8" 13/16" 1/4"Ø BOLTS @ 12" O.C. 1B 6 6 WELDED SIDE PANEL 6 1" 3/4" 3/4" 1" 9/16" 3/8" 22 GA 22 GA VIEW A - A VIEW B - B 5 1 2 3 V-A 6 3/4" 1" 1" 1" 1/2" 13 GA 1A BEADED POST (FRONT)3 ANCHOR 5 SHELF 6 SIDE & REAR X-BRACESV-A TYPICAL SHELF TO POST CONNECTION V-B SPLICE CONNECTION DETAIL LIGHT DUTY STORAGE FIXTURE ELEVATIONS 4 SHELF CLIP1BANGLE POST (REAR)2 FOOT PLATE NOTES: 1. DESIGNED PER SECTION 1613 OF THE 2020 FBC. Fa = 1.6 & Ss = 0.05 SEISMIC DESIGN CATEGORY: A. 2. STORAGE CAPACITY: 100# PER SHELF 3. STEEL: ASTM A1011 FOR SHAPE Fy = 55,000 PSI GRADE 55. 4. ALL BOLTS: A307 (UNLESS OTHERWISE NOTED). 5. ANCHORS: DEWALT POWER-STUD+ SD1. 6. ANCHORS SHALL BE INSTALLED PER ICC #ESR-2818. 7. CONCRETE: 6" THICK x 4,000 PSI. 8. MODULUS OF SUB-GRADE REACTION: 50 PCI. (DISTURBED SOIL: 500 PSF) GENERAL CONFIGURATION 7 SPLICE CHANNEL ADDRESS:DRAWING NUMBER: DESCRIPTION: DRAWN BY: DATE: LAST REV. BY: REV. DATE: APRV'D BY: SAL E. FATEEN TYPE:DATEREV.BYDESCRIPTIONSCALE:N.T.S. Tel.(909)869-0989 Covina, California EST. 1985 ENGINEERING, INC. 1130 E. Cypress St. SEIZMIC 91724 SEIZMICXL AUTO PARTS3053 INDUSTRIAL 31ST. STREETFORT PIERCE, FL 34946M.V. / T.C. 12/15/20 LIGHT DUTY SHELVING CATWALK DETAILS 20-3182-CSALFATEE N PROF E SSIONA L E N GINEERL IC E NS E FLOR I D A STATE OF No.72592 02-28-2021 EXPIRES V-C CATWALK SUPPORT BEAM CONNECTION