HomeMy WebLinkAboutNotice of Acceptance (3) 'L
h7 LE COPY
MIA MI DMIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF PERMITTING,ENVIRONMENT,AND REGULATORY AFFAIRS(PERA) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/nera
3M Company
3M Center Building 0220-05-E-06
St.Paul,MN. 55144-1000
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County PERA-Product Control Section to
be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right
to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: 3MTm 2-Component Foam Roof Tile Adhesive AH-160
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This renews and revises NOA# 11-0124.04 and consists of pages 1 through 7.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 12-0228.18
Expiration Date: 05/10/17
F.11921MIAMI•DAD,inly Approval Date:05/10/12
Page 1 of 7
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
Materials: Polyurethane
SCOPE:
This approves 3MTM 2-Component Foam Roof Tile Adhesive AH-160 as manufactured by 3M Company as
described in Section 2 of this Notice of Acceptance.For the locations where the design pressure requirements,as
determined by applicable building code,does not exceed the design pressure values obtained by calculations in
compliance with Roofing Application Standard RAS 127, for use with approved flat,low,and high profile roof tiles
system using 2-Component Foam Roof Tile Adhesive AH-160. Where the attachment calculations are done as a
moment based system for single patty placement,and as an uplift based system for double patty systems
PRODUCTS MANUFACTURED BY APPLICANT:
Product Dimensions Test Product Description
Specifications
3MTM 2-Component Foam N/A TAS 101 Two component polyurethane foam adhesive
Roof Tile Adhesive AH-
160
Foam Dispenser RTF1000 N/A Dispensing Equipment
ProPack®30 & 100 N/A Dispensing Equipment
PRODUCTS MANUFACTURED BY OTHERS:
Any Miami-Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment
resistance values with the use of 2-Component Foam Roof Tile Adhesive AH-160
roof tile adhesive.
MANUFACTURING LOCATION:
1. Tomball,TX.
PHYSICAL PROPERTIES:
Property Test Results
Density ASTM D 1622 1.6 lbs./ft.3
Compressive Strength ASTM D 1621 18 PSI Parallel to rise
12 PSI Perpendicular to rise
Tensile Strength ASTM D 1623 28 PSI Parallel to rise
Water Absorption ASTM D 2127 0.08 Lbs./Fe
Moisture Vapor Transmission ASTM E 96 3.1 Perm/Inch
Dimensional Stability ASTM D 2126 +0.07%Volume Change @-40°F.,2 weeks
+6.0%Volume Change @158°F., 100%Humidity,2
weeks
Closed Cell Content ASTM D 2856 86%
NOA No.: 12-0228.18
MIAMI•DADECOUNTY Expiration Date: 05/10/17
Approval Date: 05/10/12
Page 2 of 7
Note: The physical properties listed above are presented as typical average values as determined
by accepted ASTM test methods and are subject to normal manufacturing variation.
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Center for Applied Engineering #94-060 TAS 101 04/08/94
257818-IPA TAS 101 12/16/96
25-7438-3 SSTD 11-93 10/25/95
25-7438-4
25-7438-7 SSTD 11-93 11/02/95
25-7492 SSTD 11-93 12/12/95
Miles Laboratories NB-589-631 ASTM D 1623 02/01/94
Polymers Division
Ramtech Laboratories,Inc. 9637-92 ASTM E 108 04/30/93
Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94
01-6739-062b[l] ASTM E 84 01/16/95
Trinity Engineering 7050.02.96-1 TAS 114 03/14/96
Celotex Corp.Testing Services 528454-2-1 TAS 101 10/23/98
528454-9-1
528454-10-1
520109-1 TAS 101 12/28/98
520109-2
520109-3
520109-6
520109-7
520191-1 TAS 101 03/02/99
520109-2-1
LIMITATIONS:
1. Fire classification is not part of this acceptance.Refer to the Prepared Roof Tile Assembly for fire rating.
2. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall solely be used with flat,low,&high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of 3MTM 2-Component Foam Roof Tile Adhesive AH-
160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101.
5. Roof Tile manufactures acquiring acceptance for the use of HANDI-STICK roof tile adhesive with their tile
assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein.
F W
2
F'=
MS
NOA No.: 12-0228.18
Expiration Date: 05/10/17
MIAMI•DAD;COUNTY Approval Date: 05/10/12
Page 3 of 7
INSTALLATION:
1. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 may be used with any roof tile assembly having a current
NOA that lists uplift resistance values with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH-160.
2. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall be applied in compliance with the Component
Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive
attachment with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall provide sufficient
attachment resistance,expressed as an uplift based system,to meet or exceed the uplift resistance determined in
compliance with Miami-Dade County Roofing Application Standards RAS 127. The adhesive attachment data is
noted in the roof tile assembly NOA.
3. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 and its components shall be installed in accordance with
Roofing Application Standard RAS 120, and 3M Company's 3MTM 2-Component Foam Roof Tile Adhesive AH-
160 Operating Instruction and Maintenance Booklet.
4. Installation must be by a Factory Trained'Qualified Applicator'approved and licensed by 3M Company. 3M
Company shall supply a list of approved applicators to the authority having jurisdiction.
5. Calibration of the Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive.
The mix ratio between the "A" component and the"B" component shall be maintained between 1.0-1.15 (A): 1.0
(B). The dispense timer shall be set to deliver 0.0175 to 0.15 pounds per tile as determined at calibration. No
other settings shall be approved.
6. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall be applied with Foam Dispenser RTF1000 or
ProPack®30& 100 dispensing equipment only.
7. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall not be exposed permanently to sunlight.
8. Tiles must be adhered in freshly applied adhesive.Tile must be set within 2 to 3 minutes after 3MTM 2-
Component Foam Roof Tile Adhesive AH-160 has been dispensed.
9. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 placement and minimum patty weight shall be in
accordance with the'Placement Details'herein. Each generic tile profile requires the specific placement noted
herein.
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Profile Placement Detail Single Paddy Weight Two Paddy Weight per
Min.(grams) paddy Min.(grams)
Flat,Low,High Profiles #1 35 N/A
High Profile(2 Piece Barrel) #1 17/side on cap and 34/ an N/A
Flat,Low,High Profiles #2 24 N/A
Flat,Low,High Profiles #3 8
NOA No.: 12-0228.18
Expiration Date: 05/10/17
MIAMI•DAD;COUNTY Approval Date: 05/10/12
Page 4 of 7
i
LABELING:
Al13MTM 2-Component Foam Roof Tile Adhesive AH-160 containers shall comply with the Standard Conditions
listed herein.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
ADHESIVE PLACEMENT DETAIL 1
SINGLE PATTY
Nail through,plastic cement Paddy(Beneath Tile) Nail through plastic cement
- Paddy(Beneath Tile)
Undedayment • _ Undedayment
' 10 in.
in
10 in.
21n
Eave Course =_
Fascia Eave Course Fascia
Weephole
Eave course only: Eave course only: Eave closure
Eave Closure Keep adhesive approx. Keep adhesive approx, Drip edge
4 In.up from weepholes 4 In.up from weepholes
Nail through plastic cement Pad Beneath Tile) 1)Place Optional 2xNs for
( ace enough adhesive to achieve 17 to 23
Undedayment -_-- square Inches In contact with the pan file steep pitch applications Nall through plastic cement
2)Tom covers upside down.Place adhesive 112in.
To 1 In.From outside edge of cover tile.
Then Install the tile. o
Underlayment
10 in.
Eave Course '~'
Eave Closure
Eave course only: tRe Po
mov
Keep adhesive approx.41n.up Fascia of the eave Sheathing
from weepholes course covertile.
Abut to second course cf Optional
pan tiles.Ensure eave end of Point-up Mortar
pan and cover d%Wee
flush ateave lin on longitudinal
edges of file
Eaveclosurephole Fascia Bo
(mortarshown)
NOA No.: 12-0228.18
MIiAMI•DADE COUNTY Expiration Date:05/10/17
Approval Date:05/10/12
Page 5 of 7
ADHESIVE PLACEMENT DETAIL 2
SINGLE PATTY
Nail through plastic cement Paddy(Beneath Tile) Nail through plastic cement
Paddy(Beneath Tile)
Undedayment .� UnderlaymeM
7In. .�r2 in.
7 In%.
• Eave Course •
i
Fascia Fascia
Weephole
Eave Course Eave closure
Eave Closure Drip edge.
Nail through plastic cement Paddy(Beneath Tile)
Underlayment --
7 In. In.
Eave Closure
Eave Course Fascia
NOA No.: 12-0228.18
MIAMI•DADE COUNTY Expiration Date: 05/10/17
Approval Date: 05/10/12
Page 6 of 7
ADHESIVE PLACEMENT DETAIL 3
DOUBLE PATTY
Nail through plastic cement Paddy Nail through plastic cement Single paddy under file
(between Ole) Underlayment Single paddy between the
Paddy 2 In.x 7 In,medium
o (under tile) size paddy eave
4% 0 course only
Single paddy
I Re"1011 n.X 3 1"_;_1 n under tile
Tx 3 in. 4 In. 2 in.
Single
Single paddy an 2 in. 4 in.
urider. o paddyon
layment under-
layment
Single paddy Fascia
Eave course on top of the Weephole
Single paddy 2 In.X 7 in.medium Eave Eave closure
on top of the size paddy eave % Course Drip edge
Fascia course only
_j
Nail through plastic cement Single paddy
under Ole Single paddy
between the
ft3 In.x 3 in. 4 in.
Single paddy
on underlayment 2 n.
o
Single paddy Eave Closure
on top of Ole 2 In.x 7 in.medium
Eave Course size paddy eave course only
Fascia
END OF THIS ACCEPTANCE
NOA No.: 12-0228.18
MIAMI-DADE COUNTY Expiration Date:05/10/17
Approval Date:05/10/12
Page 7 of 7