HomeMy WebLinkAboutSewageSTATE OF FLORIDA CENTRAX #: 56-SF-07603
DEPARTMENT OF HEALTH DATE PAID:
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM FEE PAID $
N
CONSTRUCTION PERMIT RECEIPT
OPY
R 04-0872- -N
ONSTRUCTION PERMIT FOR:
X ]New System " [ ]Existing System FE ]HoldinILE g Tank C-- [ ] Innovative Other
]Repair [ ]Abandonment [ ]Temporary [ ]
PPLICANT: Letteriello, Arthur AGENT:ALEXANDER PIAZZA
ROPERTY STREET ADDRESS: Brocksmith Rd Fort Pierce FL 34945
,OT: 14 BLOCK: 3 SUBDIVISION: McHurlen Farms
[Section/Township/Range/Parcel No.]
,ROPERTY ID #: --- [OR TAX ID NUMBER]
YSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF CHAPTER 64E-6,FAC
EPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE SATISFACTORY PERFORMANCE FOR ANY SPECIFIC TIME
ERIOD. ANY CHANGE IN MATERIAL FACTS WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT,
EQUIRE THE APPLICANT TO MODIFY THE PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS,
ERMIT,BEING MADE NULL AND VOID. ISSUANCE.OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM
OMPLIANCE WITH OTHER FEDERAL, STATE OR LOCAL PERMITTING REQUIRED FOR PROPERTY DEVELOPMENT.
YSTEM DESIGN AND SPECIFICATIONS
[ .1050 ]Gallons SEPTIC TANK MULTI-CHAMBERED/IN SERIES: [Y ]
[ 0 ]Gallons MULTI-CHAMBERED/IN SERIES: [Y ]
[' 0 ]GALLONS GREASE INTERCEPTOR CAPACITY
[ 0 ] GALLONS DOSING TANK CAPACITY [ 0 ] GALL/ONS Q [0 ] DOSES
%PtE�R�24 HRS #),PUMPS[ 0 ]
[ 615 ] SQUARE FEET PRIMARY DRAINFIELD SYSTEM L5
[ 0 ]SQUARE FEET SYSTEM v
TYPE SYSTEM: [ N ]STANDARD [ N ]FILLED [ Y ]MOUND [-N ]
CONFIGURATION: [ N ]TRENCH [ Y ]BED [ N ]
LOCATION TO BENCHMARK: C/L of Road @ North Property Line
ELEVATION OF PROPOSED SYSTEM SITE [ ] [ INCHES J [ BELOW] BENCHMARK/REFERENCE POINT
.BOTTOM OF DRAINFIELD TO BE [ 12.0 ] [ INCHES '] [ ABOVE] BENCHMARK/ REFERENCEPOINT
FILL REQUIRED:[ 42.0 ]INCHES EXCAVATION REQUIRED: [ 96.0 ] INCHES
THER REMARKS:
he licensed contractor installing the system is responsible for installing the minimum
ategory of tank in accordance with s. 64E-6.013(3)(f),, FAC.
Home stubout invert to be 24 i.nches above reference point.
Excavate 531xl4'x8' deep.
0
PECIFICATIONS BY:DUNCAN, JAMES
PPROVED BY: Polissky, Jodi
%TE ISSUED: 11/16/04
TITLE:
TITLE: Environmental Spec
St. Lucie CHD
EXPIRATION DATE: 5116106
[ 4016, 03/97 (Obsoletes previous editions which may not be used)
stock Number: 5744-061-4016-0). [ostds-cons-4016-1) Page 1 of 2
STATE OF FLORIDA
DEPARTMENT OF HEALTH
< ONSITE SEWAGE DISPOSAL SYSTEM
w SITE EVALUATION AND SYSTEM SPECIFICATIONS
,PPLICANT: Letteriello, Arthur. r '
.GENT: ALEXANDER PIAZZA
iOT: 14 BLOCK: 3 SUBDIVISION: McHurlen Farms
CENTRAX #: 56-SF-07603
.OSTDSNBR 04-0872-N
ID#: ---
'0 BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE,
UST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE
OR OTHER QUALIFIED PERSON. ENGINEER'S
OF SUBMITTAL COMPLETE'ALL ITEMS
ROP•ERTY SIZE CONFORMS TO SITE
PLAN: [X]YES [ ]NO
NET
USABLE AREA AVAILABLE: 4.80 ACRES
'OTAL ESTIMATED SEWAGE FLOW:-
400 GALLONS
PER DAY
[64E-6, TABLE 11
UTHORIZED SEWAGE FLOW:
7200 GALLONS
PER DAY
[1500GPD/ACRE OR 2500GPD/ACRE]
NOBSTRUCTED AREA'AVAILABLE:
3000 SQFT
UNOBSTRUCTED AREA REQUIRED: 1231 SQFT
ENCHMARK/REFERENCE POINT LOCATION: C/L of Road @ North Property Line
LEVATION OF PROPOSED SYSTEM SITE IS 12.00 [ INCHES ] [ BELOW ]BENCHMARK/REFERENCE POINT
HE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES:
URFACE WATER: 75 FT DITCHES/SWALES:
15 FT NORMALLY WET? [ ]YES
[ X
]NO
'ELLS: PUBLIC: N/A FT LIMITED
USE: N/A
FT PRIVATE: 75 FT NON -POTABLE:
N/A
FT
UILDING FOUNDATIONS: 10 FT
PROPERTY
LINES:
10 FT POTABLE WATER LINES:
10
FT
ITE SUBJECT TO FREQUENT FLOODING:
[ ]YES
[ X ]NO
10 YEAR FLOODING? [ ]YES
[ X
]NO
0 YEAR FLOOD ELEVATION FOR SITE:
0 FT
NGVD
SITE ELEVATION: 0 FT
NGVD
SOIL PROFILE INFORMATION SITE 1
Munsell #/Color Texture Depth
lQVR-4/7-n 'GY rinP Rand 0 t0 6
l (1VR-44l -n ny Fi nP Rand f, to 7 R
iOVR-4/1-n MV rla34 lR to 79
to
to
to
to
to.
USDA SOIL SERIES: 25 Nettles sand
SOIL PROFILE INFORMATION SITE 2
Munsell #/Color Texture Depth
l OVR-41l -n CWY Fine Rand 0 to l R
l OVR-4/] -n ry ('1 ay l R to
4--
USDA SOIL SERIES
4 ..
4 ..
to
to
25 Nettles sand
BSERVED WATER TABLE: 36.00 INCHES [ BELOW ] EXISTING GRADE TYPE: [PERCHED ]
STIMATED WET SEASON WATER TABLE ELEVATION: 0.00 INCHES [ BELOW ] EXISTING GRADE.
IGH WATER TABLE VEGETATION: [ ]YES [X]NO MOTTLING: [']YES [XI NO DEPTH: 0.0 INCHES
OIL TEXTURE/LOADING RATE FOR -SYSTEM SIZING :Fine Sand/0.65 DEPTH OF EXCAVATION:96.0 INCHES
RAINFIELD CONFIGURATION: [ ]TRENCH [ X ]BED [ ]OTHER (SPECIFY)
EMARKS/ADDITIONAL CRITERIA:
ITE EVALUATED BY: JAMES DUNCAN DATE: 11/5/04
1 4015, 03/97 (Obsoletes previous editions which may not be used)
Stock Number: 5744-003-4015-1) [ostds_eval_4015-3] Page 3 of 3
STATE OF FLORIDA PERMIT NO. %
o
DEPARTMENT OF HEALTH DATE PAID:
ONSITE SEWAGE TREATMENT AND DISPOSAL FEE PAID:
'•tic' SYSTEM. RECEIPT .#:
WE APPLICATION FOR CONSTRUCTION PERMIT
APPLICATION FOR:
[ X ] New System* [ ] Existing System [ ] HoldingTank
[ ] Repair [ ] Abandonment Tempor[ ] Innovative
[ 7 ary [ 7
APPLICANT:.ARTHUR AND KELLI LETTERIELLO
AGENT: .Llexander J. Piazza PSM, Inc. TELEPHONE: 1-772-460-0160
MAILING ADDRESS: 1216 SE INDUSTRIAL BOULEVARD, PORT ST. LUCIE, FL 34952
TO BE COMPLETED BY APPLICANT OR APPLICANT'S AUTHORIZED AGENT. SYSTEMS MUST BE CONSTRUCTED
BY A PERSON, LICENSED PURSUANT TO 489.105(3)(m) OR 489.552, FLORIDA STATUTES. IT IS THE
APPLICANT'S RESPONSIBILITY TO PROVIDE DOCUMENTATION -OF THE DATE THE LOT WAS CREATED OR
PLATTED (MM/DD/YY) IF REQUESTING CONSIDERATION OF STATUTORY GRANDFATHER PROVISIONS.
PROPERTY INFORMATION
DATE
LOT: E 11 14 BLOCK: 3 SUBDIVISION: MC NURLEN FARMES PLATTED: 169
PROPERTY
ID #:
[Section/Township/Range/Parcel
No. ZONING:
PROPERTY
SIZEt•
4.80 ACRES [Sgft/43560] PROPERTY WATER SUPPLY:
[X] PRIVATE [ ] PUBLIC
PROPERTY STREET ADDRESS: BROCKSMITH ROAD, FORT PIERCE, FL 34945
DIRECTIONS. TO PROPERTY: SEE ' MAP
BUILDING INFORMATION [ X ],RESIDENTIAL [. ] COi24ERCIAL
Unit Type of No. of Building Commercial/Institutional System Design
No Establishment Bedrooms Area Sqft -Table 1, Chapter 64E-6, FAC
1 Residential 4 2314
. 2
3
4
X ] Garbage Grinders/Disposals [ X ] Spas / Hot Tubs
[. ] Ultra -low Volume Flush Toilets [ ] Other (Specify)
APPLICANT'S SIGNATURE:
DH 4015, 10/97 (Previous Editions May Be Used)
AJP JOB#: 04-0489 -
[ ] Floor/Equipment Drains
DATE:, 7-24-04
Page 1 of 3
j
Ji
I
9, STATE OF FLORIDA
DEPARTMENT; OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
'., SITE EVALUATION AND SYSTEM SPECIFICATIONS
APPLICANT: ARTHUR & KELLI LETTERIELLO
LOT: E ;t 14 BLOCK: 3 SUBDIVISION: MC NURLEN FARMS
PERMIT #
AGENT: Alexander J. Piazza PSM, Inc.
PROPERTY ID #: [Section/Township/Parcel No. or Tax ID Number]
TO BE COMPLETED BY ENGINEER, HEALTH, DEPARTEMENT EMPLOYEE,OR OTHER QUALIFIED PERSON. ENGINNEERS
MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS.
PROPERTY SIZE CONFORMS TO' SITE
PLAN: [ X ] YES [
] NO NET USABLE AREA AVAILABLE: 0.23 ACRES
TOTAL ESTIMATED SEWAGE FLOW:
300; GALLONS
PER DAY [RESIDENCES -TABLE
1/OTHER-TABLE21
AUTHORIZED SEWAGE FLOW:
GALLONS
PER DAY [1500 GPD/ACRE OR
2500 GPD/ACRE]
UNOBSTRUCTED AREA AVAILABLE:
900 +\- SQFT '
UNOBSTRUCTED AREA REQUIRED:.
SQFT
BENCHMARK/REFERENCE POINT LOCATION: 47'N AND 861W OF SE PROPERTY CORNER (20' OFFSET CORNER)
ELEVATION OF PROPOSED SYSTEM SITE IS 8 [INCHES/FT] [ABOVE/BELOW] BENCHMARK/REFERENCE POINT
i
THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES
SURFACE WATER: 100 FT DITCHES/SWALES: 15 FT NORMALLY WET? [ ] YES [ X ] NO
W LLS: PUBLIC: 200 FT LIMITED USE: '100 FT PRIVATE: 75 FT NON -POTABLE: 50 FT
BUILDING FOUNDATIONS: 7 FT PROPERTY LINES: 11 FT POTABLE WATER LINES: 100 FT
SITE SUBJECT TO FREQUENT FLOODING: [ ] YES. [ X ] NO, 100 YEAR FLOODING? [ ] YES [X] NO
100 YEAR FLOOD ELEVATION FOR SITE: FT MSL/NGVD SITE ELEVATION: FT MSL/NGVD
.1V1L YKVr-1Li. 1Nr'VKMA'1'1VN 511E 1
MUNSELL #/COLOR TEXTURE DEPTH .
TO
TO
TO
TO
I TO
TO
TO
TO
TO
USDA SOIL SERIES:
SVIL-FXUYIILE INFORMATION SITE 2
MUNSELL #/COLOR . TEXTURE DEPTH
USDA SOIL SERIES:
1V
TO
TO
TO
TO
mn
.OBSERVED WATER TABLE: 40+ INCHES' [ABOVE / BELOW] EXISTING GRADE. TYPE: [PERCHED / APPARENT]
ESTIMATED WET SEASON WATER TABLE ELEVATION: INCHES [ABOVE / BELOW] EXISTING. GRADE
HIGH WATER TABLE VEGETATION: [ ] YES [ ] NO MOTTLING: .[ ] YES- [ ] NO DEPTH: INCHES
'SOIL TEXTURE/LOADING RATE -FOR SYSTEM SIZING:
VRAINFIELD CONFIGURATION: [ ] .TRENCH [ X ] BED
REMARKS/ADDITIONAL CRITERIA:
SITE EVALUATED BY:
DEPTH OF EXCAVATION: INCHES
[ ]'OTHER (SPECIFY)
DH 4015, 10/96 (Replaces HRS-H Form 4015 [page 31 which may be used)
AJP JOB#: 04-0489-
Page 3 of 3
i S. I nrsb/ wsh tut ► W eorrplq aia b +D1k M,+ orTYo JA paw Cede
+nd fur , woe W went or rffdW mawv l,TI. I me" Lu Lue r W M obtatr„/
PAW IrmnrwCA-d of Vol wa%dero to" W*"a M of "pfaw e, ru
wp,cooaa 1, x,6.0 and Wt I oa Maie ee mu q Vp- i Fe4 eeir.Md" ooi, r Yc+l
Gownrr4N4 a pptcsbk. l Wed a prwW e vdeon l `1 repen V Iw WM W k'Veero
• Akv HLne or 11+, p„ni e:arSa r1rkl�vioan its J
STATE OF FLORIDA PERMIT APPLICATION TO'CONSTRUCTI
Permit No. •—
Y Q REPAIR, MODIFY, 0'R ABANDON•A WELL
Scpuc No.
0 Southwest
Permit Stipulations equued
0 Northwest THIS FORM MUST BE FILLED OUT COMPLETELY.
62-524 wcll 0
0 SL Johns River The walaws0•confractorls nspoA&W# lorcompl•Ung the
-jP/
0 South Florida Farm and Forwarding the permit to th.e approprfafs delegated
' •a°Op�
""P ApP lication No.
0 Suwannee River c0uaywhenappkcab1i.
'CHECK BOX FOR APPROPRIATE DISTRICT
`
- • o/% ET • -�.5�,�-.�9/ /a:�/ T _ /�Sr : e �G 35�9•-f3
Owner, Legal Nime or Entity Corporation Address ;Ity
�P-s - ... wo,-,�s�•r�
ZJp Tererliore Numbu
Well Ltxatlon —Address, Road.Name, Cky and ZIP
3,� William H. Barrett 11144 (777) 781-1769
I t a... No Telephone
No. NW HE
Well Drilling Contrscicr
2441' S. E. Dixie . Hwy. , 4. _Yof Y.orsection4
Address t+I O�ve
'(Indlale Well on Chart)
Stuart Florida 34996 . b. Ta+rtuhip� Range
City State ZIP r
6. - St. Lucie
County Subdlvislon Nuns Lot Block Unit
E
7. Number of proposed wells % Check the use of well: DomesUc (Res. Home) _Monitor _ Irrigation (Residential)
_ IrrigaUon (Business) _ Public Water Supply (Business) List Other
Distance from septic system;�1 _R. �s Dpyfrom foundetlon �'� R. Description of facility
Estimated start of consjrucdon date f/ j
a. Application for. r New Construction Repalr/Modlfy APP-31 Stamp
Abandonment (Reason for abandonment )
9. Estimated: Weil Depth Casing Depth
Screen Interval from l (o �'J Casing Material: B0',31 G • PVf✓
Casing Diameter��T_ SeaLMatirlal ar'�
10. 1f applicable: Proposed From to Seal Material
Grouting Interval From to Seal Material -
From to Seal Material txaw a nap dr,1 L�atiril and vz'tah rir sire Intel an x. lCaC3Y tr'wn
Rwds ud brdmarks; pvride �t tiofwe,n lrel
11. Telescope Casing or liner (check one) Diameter
Blk-Steel / Galvanized / PVC Other (specify): �(�r
12. Method of Construction: —�- Rotary Cable Tod _ Combination
Auger Other (specify):
13. Indiate total No. of wells on site List No. of unused wells on site 0 W94I E,n
14.113 this wal or any otherwel orwsW wlthdrsxal on the owne(s con duo? l N oNe� Yaat U 1 DD ►5 oN
a Cori umptllre 31* Usa Pem1lt (CUP/4YUP) or CUPA'NP APpba Lw Et A�KEAtM
sr
(u yss. oompr•re Me k owing) CUWHUP No. VISiO
District well ID No.
Latitude Longitude'
Data obtaUled from GPS -_ or MP _ or survey ._. (n%aP datum W1D 27 _ F1AD 83 _ )
I Well, Rat I et t• ewer of M trop,rd, fur fr idor M&A r7A6e0Ii ftrfW, erd Wtl sn sr+n of Rf
,e,pbe,+�:iM wd�r OWW 3n pa I a SW gK 0 eirbe rprapertr eb. n r" y,•C ar. I ar7r M I an
Moponcbuw r sail o � ►VWV4 d N W or a NPN&&-A*- +— a tr .Wa mod e,L
Approval Granted By. �I� Issue Date:
Owner Number. Fee Received: Re
Hydrologist Approval
Check. No.:
Date:
Inspected by:
THIS PERMIT NOT VALID UNTIL PROPERLY SIGNED BY AN AUTHORIZED OFFICER OR REPRESEHTATNE OF THE
Y&ID. (TSHHALlld SHALL BE
90 days leom da r, 'E AT1. of ru LL
SrTE SURING ALL DRILLING OPERATIONS.
Form 0173
LEGAL DESCRIPTION:
EAST ONE-HALF (E 1/2) OF LOT 14, BLOCK 3, OF McNURLEN
FARMS, ACCORDING TO THE PLAT THEREOF AS RECORDED IN
PLAT BOOK 4, PAGE 56, OF THE PUBLIC RECORDS OF ST.
LUCIE COUNTY, FLORIDA.
CONTAINING 209,163 SQUARE
OR LESS.
W1,2LOT 11
B OCK 3
(PB 4, PG 56)
FEET OR 4.802 ACRES, MORE
FND IRC
* GCY"
10.01'W,0.21'S
rnc�'0
ui
St, P-uc,,Q CiDulitY Hiaalth Dept
EnviPoi` mePi al a`,4P__a;'ta`i Sett on
Site PFoan Ap m Y„ed for °;1:. �istructio. i
.vious PI n for
Revd wel':
E 112 LOT 11
BLOCK 3
(PB 4, PG 56)
I 4' WIRE FENCE
' WIRE FE PL
FND IRC
"PLS#3435"
b I x�
x� 1 N89046'26"E 6,
�+
x �x
o� �'
0.01 S
APPROVED
o
o
O
\
004
C 2 2 .p
LUNTY
PROPOSED
288.90' WELL
26'
\
�� N
ST HEALTH DEPARTMENT ^s
o
-ENVIROBMNTAH DI 110N
;13 x�..
g
LOCK 3 (,i (,,t
(PB 4, PG 56) �
oo
DIMEICVJ
,p rn
, 4
lu m
0
r r
SEE DETAIL A
DRAINFIELD &--
SEPTIC SYSTEM
��
J
ti
w
w
�
x moo.
4' WIRE FENCE.
t1.0'W OF PL
FND IRC
_ "PLS#3435"_ _
0.03'W,0.12 S
00
ABBREVIATIONS:
(C) = CALCULATED `7 c/r�T 0(0
(M) = MEASURED IOC %s -4 Cj
(P) = PLATTED
CMP = CORRUGATED METAL PIPE S6 ��
CNS = COULD NOT SET
CONC = CONCRETE
!PE = DRAINAGE EASEMENT
FFE = FINISHED FLOOR ELEVATION
FND = FOUND 5/8" IRON REBAR
•IE = INGRESS -EGRESS EASEMENT
IRC = 5/8" IRON REBAR WITH PLASTIC CAP
t/S = OFFSET
PCOR = PROPERTY CORNER.
PCP = PERMANENT CONTROL POINT
PL = PROPERTY LINE
PUDE = PUBLI.0 UTILITIES AND DRAINAGE EASEMENT
R/W = RIGHT-OF-WAY
R = RADIUS OF CURVE
L = LENGTH OF CURVE
SF = SQUARE FOOT
UE = UTILITY EASEMENT
4 = DELTA OF CURVE
0 ='SET 5/8" IRON REBAR WITH PLASTIC
:CAP ".AJP PSM 6330"
I
�Q.
cfl � w II
Ln
CV M (D N
35' `-Y 0-
15' O~0
Jmm
xt1ro
xq a $
LOCATION MAP
NOT TO SCALE
SURVEYORS NOTES:
1. THIS IS A SPECIFIC PURPOSE SURVEY AS DEFINED IN
CHAPTER 6113174.002(8) FLORIDA ADMINISTRATIVE CODE.
2. THIS SURVEY IS BASED ON A BOUNDARY 'SURVEY PREPARED BY
JAMES FOWLER, DATED 5-9-03, DRAWING NO.: 3776-B'AND A
SPECIFIC PURPOSE SURVEY TO SHOW EASEMENTS, DATED
8/12/03, DRAWING NO.: 3776B-B EASEMENTS. NO BOUNDARY
VERIFICATION WAS PERFORMED BY ALEXANDER J. PIAZZA
PSM, INC. OF THE UNDERLYING MCNURLEN FARMS PLAT AS
RECORDED IN. PLAT BOOK 4, PAGE 56, OF THE PUBLIC
RECORDS OF ST. LUCIE COUNTY, FLORIDA.
3. THE SPECIFIC PURPOSE OF THIS SURVEY IS TO OBTAIN A
BUILDING,PERMIT. THIS SURVEY IS NOT VALID FOR ANY
OTHER USE.
3. NO UNDERGROUND UTILITIES OR IMPROVEMENTS WERE LOCATED
UNLESS OTHERWISE SHOWN.
4. THIS SITE LIES WITHIN FLOOD ZONE "X", ACCORDING TO
THE FLOOD INSURANCE RATE MAP, COMMUNITY PANEL NO.
12111CO165 F, EFFECTIVE DATE AUGUST 19, 1991.-
5 If O0 ZONE SHOWN HEREON IS AN INTERP, TATIONI BY THE
SURVEYOR AND IS PROVIDED AS A COURTESY: THE FLOOD
ZONE SHOULD BE VERIFIED BY A DETERMINATION AGENCY.
6. BEARINGS SHOWN HEREON ARE BASED ON THE WEST LINE OF
LOT 14 AS'BE ING N00'04'22"W ACCORDING TO THE PLAT
DESCRIBED HEREON.
7. ALL LOT DIMENSIONS SHOWN ARE PER SURVEY PREPARED BY
JAMES FOWLER, SPECIFIC PURPOSE SURVEY 'TO - SHOW
EASEMENTS, DATED 8/12/03, DRAWING NO.: 3776B-B
EASEMENTS, UNLESS OTHERWISE NOTED.
8. NOT VALID WITHOUT THE SIGNATURE AND ORIGINAL RAISED
SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER.
9. THIS SURVEY IS PREPARED ONLY FOR THE PARTIES LISTED
BELOW AND IS NOT ASSIGNABLE.
PREPARED FOR: ARTHUR AND KELLI LETTIELLO
LEXAND J. PlAzow
Professional' ur\1 & Mo pper
Florida Certificate No.: 630
LAST FIELD DATE: 7-20-04
8 _0 C G 0 0 GA G R JP ALEXANDER J. PIAZZA PSM, INC. SPECIFIC PURPOSE SURVEY �n K:\BUILDERS\CAMPBELL ACRE$\DWG\04-489
Surveying • Mapping - Consulting ICKD
EF K: \BUILDERS\CAMPBELL ACRES\DWG\CAMPMG01
1216 SE Industrial Boulevard LOT 14, CAMPBELL ACRES LO SIN FS. PG. JOB 04-0489
® Port St. Lucie, Florida 34952 SEC 20, TWP 35S, RGE 39E
Phone: (772) 380-0000 AS PREPARED FOR FF AJP DATE 07/24/04
DATE: REVISIONS: s . w r/m Fax: (772) 380-0520 1ARTHUR AND KELLI LETTERIELLO AJP SHEET 1 OF 1 DWG
• C-015
D IRC
LS#2391"
�
°
JI I t OLINt r1P
+10.18 ASSI
°ox
FND IRC
"PLS#3435'!
20 o S E
ba E 1 /2LOT 14 0�
(PBBL4, BL00
56) 0m
VACANT
270.86'
CO
U..1
a -
_j m
Z11 1
PROPOSED DRIVE
rr~U
285.17'
m
r
9 SITE BENCHMARK
-+•10.00 ASSUMED
50' IE,UE,DE
(ORB 1920, PG 1373)
y a
FND IRC
.s "PLS .3435"
x X 20 /S E
o s
ox S89'46'33"W4!�x634.49' 6
E 1W2 'LOT 15 x
LOCK 3
(PB 4, PG 56)
r74.67'
N
w
u
PROPOSED CBS SCALE; 1•-10'
IRESIDENCE 25.33' DETAIL "A I
18.00' 7
67' w I
w
n<<
Om
W �I� N Az D
I w o= as �� 11.33'N PROPOSR�V�
ED I
v� w
c„
moo-Imoo-I 34.67' I
{ 6 - 6I - - -
0 o M
c� 0
Y ❑-
l__ U
35' O O •4
15' m m
PLOT PLAN
- WELL AND SEPTIC