HomeMy WebLinkAboutCompaction TestANDERSEN ANDRE CONSULTING ENGINEERS, INC. 834 SW Swan Avenue Port St. Lucie, Florida 34983 Phone: 772-807-9191 Fax: 772-807-9192 www.aaceinc.com PROJECT: Parcel I.D. 4203-231-0002-000-9 FILE NO: 20-276 Carlton Rd., St. Lucie County REPORT NO: 1 REPORTED TO: Mr. Pete Debus DATE OF TEST(S): 10/30/2020 PAGE NO: 1 OF 1 TEST NO. Debus Residence, Carlton Road House Pad (Top 12" Lift) MDR MOISTURE DENSITY DRY PERCENT DEPTH NO. CONTENT (%) (NSI COMPACTION LOCATION 1 4'E and 6'S from the NW corner of pad 4115 6.9 111.3 97 0 to -12" FS 2 9'E and 16'N of SW corner of pad 4115 6.1 108.5 95 0 to -12" FS 3 TW and TN of SE corner of pad 4115 8A 108.9 95 0 to -12" FS 4 9'W and TS of NE corner of pad 4115 8.6 109.7 96 0 to -12" FS 5 Center of pad 4115 7.5 109.5 96 0 to -12" FS * DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 95 PERCENT. ** RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS PER SPECIFICATIONS FIELD TEST: 7 ASTM D-2937 ASTM D-6938 f- ASTM D-2167 ASTM D-1556 TECHNICIAN: KJ REMARKS: LABORATORY MOISTURE -DENSITY RELATIONSHIP F = SOIL DIRECTLY BELOW FOOTING FS = FLOOR SLAB SUBGRADE ASTOPTIMUM GA = SOIL IN GENERAL COMPACTED AREA PAV = SOIL BELOW STABILIZED SECTION MDR NO. TEST METIHOD DENSITY MOISTURE PSSG = STABILIZED SUBGRADE PB = PAVEMENT BASE CONTENT RS = ROADWAY NSSG = NON STABILIZED SUBGRADE 4115 D1557 114.6 PCF 9.8 % SBP = SOIL BELOW PAVEMENT TOP = TOP OF PIPE BOP = BOTTOM OF PIPE BOS = BOTTOM OF STRUCTURE OTHER: ���� �O P• 'ENO ���% N. Da !fP. A,/ Ire, Jbo 539W Flatter* yo. 53969Ix �r AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL Pf�pPE 1t?F CLIENYRIZAT14AI gam.. FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PE�D�1,R W�N.ND RITTEN APPROVAL. 0 `-'► '/idlllp, ANDERSEN ANDRE CONSULTING ENGINEERS, INC. 834 SW Swan Avenue Port St. Lucie, Florida 34983 A Phone: 772-807-9191 Fax: 772-807-9192 www.aaceinc.com MOISTURE -DENSITY RELATIONSHIPS PROJECT: Parcel I.D. 4203-231-0002-000-9 FILE NO: 20-276 Carlton Rd., St. Lucie County REPORT NO: 1 REPORTED TO: Mr. Pete Debus CC: PERMIT NO: 125 _ 120 O O LL V m 115 U 0: w a SUMMARY OF TEST RESULTS TEST METHOD: ASTM D-698 ASTM D-1557 (STANDARD)►+' (MODIFIED) MAXIMUM DRY DENSITY (lbs/ft3): 114.6 OPTIMUM WATER CONTENT (%): 9'8 REMARKS: 110 O CURVES OF 100% SATURATION FOR SPECIFIC GRAVITY EQUAL TO: a H m O 105 2.65 2.70 2.75 IL Z 100 95 0 5 10 15 20 25 30 35 MOISTURE CONTENT (PERCENT OF DRY WEIGHT) SAMPLE NO: 4115 DESCRIPTION: Brown to SAMPLE LOCATION: Composite sample, house pad fill ,yey to clayey fine sand w/traces of shell and rock,%,04M U////,/,, DATE SAMPLED: 10/30/2020 BY: SM \�PJ`O , e _'YVO,�j DATE TESTED: 11/3/2020 BY: RL _'David P. r(r.E. *.:Reg. No. 53069�— AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAI.BR E TY OF ��.�F ,,SSqqA�@AUTHQQ FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVEtY� &)BING OUF��M1lpPROVaU�