ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020)
Based on Section 1525 of the Florida Building Code-Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Required Sections of Attachments Required
j Roof System the Permit Application See List Below
Form
Low Slope Application A,B, C 1,2,3,4,5,6,7 '
Prescriptive BUR-RAS 150 A, B,C 2,4,5,6,7
Asphaltic Shingles A, B,D 1,2,4,5,6,7
Concrete or Clay Tile A,B, D, E 1,2,3,4,5,6,7
Metal Roofs A,B,D 1,2,3,4,5,6,7
Wood Shingles and A, B,D IA4,5,6,7
Shakes
Other As Applicable 1,2,3,4,5,6,7
ATTACHMENTS REQUIRED As Applicable):
1. Fire Directory Listing Page
2. From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3. Design Calculations per Chapter 16,or if applicable, RAS 127 or RAS 128
4. Other Component of Product Approval
5. Municipal Permit Application
6. Owners Notification for Roofing Considerations(Reroofing Only)
7. Any Required Roof Testing/Calculation Documentation
Form RooflnfoFeb21 Rev Feb 18,2021
to
ST LUCIE WORKS
Section A (General Information)
Master Permit No. Process No.
,Ohl ILL IPS
Contractors Name: License#
Job Address _�635 SILoQi,R 0AV, L?(L, f 0
ROOF CATEGORY
❑Low Slope ❑Mechanically Fastened Tile ❑Mortar/Adhesive Set Tiles
❑Asphaltic Shingles Metal Panel/Shingles ❑Wood Shingles/Shakes
❑ Prescriptive BUR-RAS 150
ROOF ROOF TYPE.x
[INew roof ❑ Repair ❑ Maintenance Reroofing ,Recovering
ROOF SYSTEM INFORMATION -
Low Slope Roof Area(SF) � Steep Sloped Roof Area (SF) Total(SF)
,3o So
Section B(Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets.
0011 lv /
I� IV
f f�
f
1 i '
f �
ST. LUCIE 4,F` O Rs ,
Section C (Low Slope Roof)
Surfacing: 7� 7 G►��(r�, Pry -s 7rgm
Fill in specific roof assembly components and identify Fastener Spacing for Anchor/Base Sheet Attachment:
Zone 1 ._.._. oc @Lap,#Rows_�
manufacturer L4 °
ac
(If a component is not used,identify as"NA") ,� 3 ® °o0
Zone 1:_�z._ oc @Lap, #Rows
System Manufacturer: S�l1,�JS /���/�� yv •Zone 2-L"oc @ Lap, #Rows-2-® °oc
Product Approval No.: . Zone 3•� "oc @ Lap, #Rows @ oc
Number of Fasteners Per Insulation Board:
Design Wind Pressures,From RAS 128 Or Calculations: Zone 1': Zone 1., Zone 2: Z �he 3:
•i
Zone V: one 1:-�N-Zone 2 Zone 3-(r3►J Illustrate Components Noted a Details as Applicable:
Max. Design Pressure, from the specific product approval Woodblocking, Gutter, Edge ermination, Stripping,
system: �� �'� Flashing, Continuous Cleat, Cant. trip, Base Flashing,
Counterflashing,Coping,Etc.,
Deck: Indicate: Mean Roof Height, Parapet Height, Height of Base
Type: / ��(,JO(� Flashing,Component Material, Material'Thickness, Fastener
l s/ 3 2 Type,Fastener Spacing or Submit Manufacturers Details that
Gauge Thickness: Comply with RAS 111 and Chapter 16..
V �
Slope: �a P !_LK � 11� r.,
Anchor/Base Sheet&No.df Ply s):
/s/6z =�� �� p�y��
FT.
Anchor/Base heet Fastener/ riding Material:
Insulation 6ase Layer: N/A N r
Base Insultation Size and ess: Pa apet
Base Insulation Fastener/Bonding Material: Height
Top Insulation Layer:
Top Insulation Size and Thickness: A FT.
Top Insulation Fastener/Bondi g Material: f
N Mean I
Base Sheet(s)&No.of Ply(s): ./`11A I Roof /
Base Sheet Fastener/Bonding Materi I: 7 A Height
Ply Sheet(s)'& No. of Ply(s):fs 3Z �'LrL •
Ply Sheet Fastener/Bonding Material:
Top Ply: aw: 4ckuCat 5✓ c crime �AWAL-UP-IF-
Top Ply Fastener/Bonding Material:
CSt' -X)S IPJZI
10
ST. LUCIE V11 RKS
Section D (Steep Slope Roof System)
Roof System Manufacturer:
Notice of Acceptance Number: ( ,
Minimum Design Wind Pressures,If Applicable(From RAS 127 or Calculations):
Zone 1:_Zone 2e: one 2n:_Zone 2r:_—Zone 3e:_Zone 3r: /" A
Deck Type: /S �Z rPK Co }� L ILL
Type Underiaymenti 30-* Qj
Roof Slope:
lf� 12
insulation: P A
Fire Barrier:
Ridge Ventlation? Fastener Type&Spacing:
_ JA)
va,, � Adhesive Type:
Type Cap Sheet: Z y �� �A►aC�� �11��P
Mean Roof Height: Roof Covering:
Type&Size Drip �• �QC�u/''ll��%`''I j���l/o
Edge: � `�
ll
REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS
It is the responsibility of the roofing contractor to provide the owner with the required roofing Permit,and to
explain to the owner the content of this form. The owner's initials in the designated space indicates that the
item has been explained.
1. Aesthetics-workmanship:The workmanship provisions of Chapter 15(High Velocity Hurricane
one)are for the purpose of providing that the roofing system meets the wind resistance and water intrusion
performance standards. Aesthetics(appearance)are not a consideration with respect to workmanship
provisions.Aesthetic issues such as color or architectural appearance,that are not part of a zoning code,should
be addressed as part of the agreement between the owner and the contractor.
2.Renailing wood decks:When replacing roofing,the existing wood roof deck may have to be renailed
1 accordance with the current provisions of Chapter 16(High Velocity Hurricane Zones)of the Florida Building
Code. (The roof deck is usually concealed prior to removing the existing roof system).
3.Common Roofs:Common roofs are those which have no visible delineation between neighboring
nits(i.e.townhouses,condominiums,etc.).In buildings with common roofs,the roofing contractor and/or
owner should notify the occupants of adjacent units of roofing work to be performed.
4.Exposed'Ceilings:. Exposed,open beam ceilings are where the underside of the roof decking can be
viewed from below. The owner may wish to maintain the architectural appearance;therefore,roofing nail
penetrations of the underside of the decking may not be acceptable.The owner provides the option of
maintaining thls appearance.
S.Ponding Water:The current roof system and/or deck of the building may not drain well and may
cause water to pond(accumulate)in low-lying areas of the roof. Ponding can be an indication of structural
distress and may require the review of a professional structural engineer.Ponding may shorten the life
expectancy and performance of the new roofing system.Ponding conditions may not be evident until the
original roofing system is removed.Ponding conditions should be corrected.
6. Overflow scuppers(wall outlets):it is required that rainwater flow off so that the roof is not
verloaded from a buildup of water.Perimeter/edge walls or other roof extensions may block this discharge if
overflow scuppers(wall outlets)are not provided.It may be necessary to install overflow scuppers in
accordance with the requirements of:Chapter 15 and 16 herein and the Florida Building Code, Plumbing.
7. Ventilation:Most roof structures should have some ability to vent natural airflow through the
terior of the structural assembly(the building itself).The existing amount of attic ventilation shall not be
reduced.
Owner's/Agent'sSignature: .� 71Date:[]