Loading...
HomeMy WebLinkAboutCompaction TestUES Project No: Workorder No: Report Date: 3360.1800067.0000 227605-1 03/15/2021 607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580 In-Place Density Test Report Client:D.R. HORTON, INC. EAST FLORIDA DIVISION UES Technician:Sean Hayes 1430 Culver Drive, NE Palm Bay, FL 32907 Date Tested:03/11/2021 Project:CMT CREEKSIDE Yorktown Drive & Okeechobee Road,Fort Pierce, County, FL Type of Test: Area Tested:Lot 42 - 3322 Trinity Circle Field:ASTM D-6938 Nuclear Gauge Method Material:Native Laboratory:ASTM D1557 Modified Proctor Reference Datum:0 = Top of Final Grade The tests below meet the 95% minimum compaction requirement. Test No.Location of Test Range Maximum Density (pcf) Optimum Moisture (%) Field Dry Density (pcf) Field Moisture (%) Soil Compaction (%) Pass or Fail 1 NE Corner 0-1 ft 118.6 10.8 115.9 10.2 98 Pass 2 SW Corner 0-1 ft 118.6 10.8 114.7 9.9 97 Pass 3 Center 0-1 ft 118.6 10.8 116.9 10.2 99 Pass Remarks:Permit: 2011-0169 Reviewed By GFA International, Inc FBPE Registry No.4930 Thomas Dominic Montano Branch Manager STATE OF FLORIDA Professional Engineer No. 84146 To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1 This item has been digitally signed and sealed by Thomas Dominic Montano, P.E. on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.