Certification for Design Load Compliance
Project Name: Century Complete -1449
Project Address: 7801 James Road,
s�nojlo r-ow ccn5elvx4ibf�
Permit#: Occupancy Type: f- i I k4 _Construction Type: c MCrPf-P
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for inteirior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 21017 Code Sixth Edition with 20 N/A Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed Partially Enclosed Open
3. Risk Category: I X II III IV Exposure Category: B X C D
4. Design Wind Velocity 160 mph ASD X LRFD End Zone Width: 3.6 ft
5. Mean Roof Height 11 ft Roof Pitch: 4 :12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: +19.3,-30.6 Zone 2: +19.3,-53.3 Zone 3: +19.3,-78.9 Zone 4: +33.5,-36.3 Zone 5: +33.5,-44.8 Garage: +31.7/-38.6
7. Design Loads: Floor: 40 PSF Roof/Dead: 17 PSF Roof/Live: 20 Balcony: N/A PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: 50 PSF
8. Were Shear Walls Considered For Structure? Y Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? Y Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 1500 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with t,�jgjgrj"'Ie structural portions of the building codes currently adopted and enforced by St. Lucie
County. ;t�riiy 1R tural elements depicted on these plans provide adequate resistance to the design
♦ •°°oeo®o•wo B
forceseO v�G li0g9 .• ti
+oo YIEE
�•� James G. Friling
*::f r
• Print Name Cert # & Co. Cert Auth.
�'0 �; Q. PE #77824 COA #27228
p :i : Q.—
�A °.°- ♦� Mulhern + Kulp Structural Engineering - 300 Brool�si�nb119002
�'��is��NA��e�♦♦♦,, ` Company Name & Address ^�p��l����
Revised 12/07/2018 . _ CODE COMPLIANCE
AllG2 5 20211 �To LUCIE COUNTY
B®CC