Loading...
HomeMy WebLinkAboutAPPROVED, PA 16842.6121812020 Flonda Building Code Online Business& Professional Regulation BaS Florae Lop In User Registration Hot Topics Submit Surcharge Stats & Facts Publications bo / r Product Approval -Ir USER: publicUser Product Approval Menu > Product or AppllcaUon 5earci_ > Application List Search Criteria ARM Contact Us a= Site Map Links Search Refine Search Code Version 2020 FL# 16842.6 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model, Number or Name ALL Product Description ALL Approved for use In HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL Search Results - A plications ELA DRE Manufacturer Validated Status �lL FL16842- Revision New5outh Window Solutions Ryan 3. Approved R6 FL#: FL16842.6 King, P.E. History Model: f, Series 9000 Model 9550 Slider XO - Impact Rated - HVHZ (813) 767- Description: Extruded Vinyl "impact" Horizontal Sliding Window with Flange 6555 Installation (XO or OX configurations) Category: Windows Subcategory: Horizontal Slider FL16842- Revision New5outh Window Solutions Ryan 1. Pending FBC RZ FL#: FL16842.6 King, P.E. Approval Model: f, Series 9000 Model 9550 Slider XO - Impact Rated - HVHZ (813) 767- Description: Extruded Vinyl "Impact" Horizontal Sliding window with Flange 6555 Installation (XO or OX configurations) Category: Windows Subcategory: Horizontal Slider 'Approved by DBPR. Approvala by OBPR>¢ I be reviewed and ratified by the POC and/or the Commkaion If necessary. Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer..Qo YrIght 2007-2013 State of Florida.:: Prfvacy Statement :: Acc=Iblllty. Statement :: Refund Ste ement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mall to this entity. instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), norida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F,5, must provide the Department wltti an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, ES., please dick hers-, Product Approval Accepts: © to®e_rt-r Credit Card Sate htips://www.floridabuilding.org/pr/pr_app_lst.aspx 111 12/8/2020 Florida Building Code Online B= Moms Lop In User Reg Watlan F! tiila dpr _ Product Approvol USR:Public User Product Approval Menem > Prvdutt or Agpii(;anDr Seaisri > 600iication List > Application Detail MM'l FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Hot 7l pks Submit Surcharge Stats & Facts Publications Contact Us BCIS Ste Map unks Search FL16842-R6 Revision 2020 Approved NewSouth Window Solutions 10741 Crossroads Commerce Blvd. tampa, FL 33610 (013)626-6000 danochstein@newsouthwindow.com Vivian Wright rickw@rwbldgconsultants,com Windows Horizontal Slider Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Lyndon F. Schmidt, P.E. Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2021 Validated By Ryan ). King, P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL€6842 R6 COI fe) Certificate of Independence,p�if Referenced Standard and Year (of Standard) Standard Year AAMA/WDMA/CSA101/I.S.2/A440 2008 AAMA/WDMA/C5A101/1.S.2/A440 2005 AAMA/WDMA/CSA101/I.S.2/A440 2011 ASTM E1886 2005 ASTM E1996 2006 ASTM E1996 2005 ASTM E1996 2009 TAS 201, 202, 203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL16542 R6 Eapiv of Standards(A),pQ https://www.floriiiabuilding.orglprlpr app_dd.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZ076]FGu3AxBTPX3DrJTXeXQ%3d°/a3d 1/5 12/8/2020 Sections from the Code Florida Building Code Online Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Date Revised Summary of Products Go to Page 0 Method I Option D 07/26/2020 08/10/2020 08/18/2020 10/13/2020 10/28/2020 0 0 Page 1/ 2 0 0 FL # Nodal, Number or Name Description 16842.1 a. Series 9000 Model 950D Slider XO Extruded Vinyl "Nan -Impact" Horizontal Sliding Window utllWnq a Nall Fin Installation (XO or OX configurations) Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 16842.1 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. 16842.2 b. Series 9000 Model 9500 Slider XO Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 16842.2 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Installation Instructions FL16842 R6 II (f) Inst 16842.1.(-If Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports EL16842 R6 AE (f) Eval 16842 Lp_gff Created by Independent Third Party: Yes Extruded Vinyl "Non -Impact" Horizontal Sliding Window with Flange Installation (XO or OX configurations) Installation Instructions FL16842 R6 II (f) Inst 16842.2.pdf Verified By: Lyndon F Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL16842 R6 AE (f) Eval 16842.2.pdf Created by Independent Third Party: Yes C. Series 9000 Model 9550 Slider XO Extruded Vinyl "Impact" Horizontal Sliding Window utilizing a - Impact Rated Nall Fin Installation (XO or OX configurations) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 16842.3 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Installation Instructions FL16842 R6 II (f) Inst 16842,3.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL16842 R6 AF if', E-v 1684e_=poi Created by Independent Third Party: Yes 16842.4 d. Series 9000 Model 9550 Slider XO Extruded Vinyl "Impact" Horizontal Sliding Window with Flange - Impact Rated Installation (XO or OX configurations) Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 16842.4 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Installatlon Instructions Fi_16842 R6 II (f) lnst 16842.4.p_df Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL16842 R6 AE (f) Eval 16842.4.pgJf Created by Independent Third Party: Yes 16842.5 e. Series 9000 Model 9550 Slider XO Extruded Vinyl "Impact" Horizontal Sliding Window utilizing a - Impact Rated - HVHZ Nail Fin Installation (XO or OX configurations) Limps of Use Installation Instructions Approved for use In HVHZ: Yes FL16842 R6 II (f) Inst 16842,t>.p-LT for use outside HVHZ: Yes Verified By: Lyndon F Schmidt, RE. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 16B42.5 for Design Pressure Ratings, any FL161142 R6 AE (f) Eval 16842.5.pdf additional use limitations, installation instructions and product. Created by Independent Third Party: Yes particulars. https://www.floridabuilding.org/pripr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZ076[FGu3AxBTPX3Dr-JTXeXQ"/`3d%3d 2/6 12/8/2020 Florida Building Code Online 16842.6 f. Series 9000 Model 9550 Slider XO - Impact Rated - HVHZ Extruded Vinyl "Impact" Horizontal Sliding Window with Flange Installation (XO or OX configurations) Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 16842.6 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. 16842.7 g. Series 9000 Model 9500-3 Slider XOX Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 16842.7 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. 1-- ____ — 16842.8 h. Series 9000 Model 9500-3 Slider IXOX Limits of use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 16842.8 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Installation Instructions EL16642 R6 II if) Inst 16842.6.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL16842 R6 AE (f) Eval 16842.6.pdf Created by Independent Third Party: Yes Extruded Vinyl "Non -Impact" Horizontal Sliding Window Utilizing a Nail Fin Installation (XOX, configuration) Installation Instructions FL16842 R6 II (f) Inst 16842.7.12df Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL16842 R6 AE lf) Eval 1b842.7.p_d_f Created by Independent Third Party: Yes Extruded Vinyl "Non -Impact" Horizontal Sliding Window with Flange Installation (XOX, configuration) Installation Instructions FL16842 R611- ffj Inst 16842.8.122 Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL16842 R6 AE_ {f) Eval 16842.8.= Created by Independent Third Party: Yes 16842.9 1. Series 9000 Model 9550-3 Slider Extruded Vinyl "Impact" Horizontal Sliding Window utilizing a XOX - Impact Rated Nall Fin Installation (XOX, configuration) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 16842.9 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Installation Instructions FL16642 R6 lI (f) Inst 16842.9.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL16842 R§ AE f) Eval 16842.9.Pdf Created by Independent Third Party: Yes 16842.10 J. Series 9000 Model 9550-3 Slider Extruded Vinyl "Impact" Horizontal Sliding window with Flange XOX - Impact Rated Installation (XOX, configuration) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 16842.10 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Installation Instructions FL16842 R6 II (f) Inst 16842.10.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FLIGS42 Created by Independent Third Party: Yes 16842.11 k. Series 9000 Model 9550-3 Slider Extruded Vinyl "Impact" Horizontal Sliding Window utilizing a XOX - Impact Rated - HVHZ Nall Fin Installation (XOX, configuration) Limits of Use Approved for use In HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 15842.11 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. 16842.12 I. Series 9000 Model 9500-3 Slider XOX - Impact Rated - HVHZ Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 16842.12 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Installation Instructions FL16842 R6 I1`(f) Inst i6842.1L�f Verified By. Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL16842 R6 AE (f) Eval 16842,11 pof Created by Independent Third Party: Yes Extruded Vinyl "Impact" Horizontal Sliding Window with Flange Installation (XOX, configuration) Installation Instructions FL16842 R6 II if) InsL 16842.12.= Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL16842 R6 AE (f) Eval 16842.12.pdf Created by Independent Third Party: Yes https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsf°/`2fLKgxApZZ0761FGu3Ax8TPX3DcJTXeXQ%3d%3d 3/5 12/8/2020 Florida Building Code Online 16842.13 m. DuraGard Slider XX I Extruded Vinyl "Non -Impact" Horizontal Sliding Window utilizing a Nall Fin Installation (XX, configuration) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: This Product is No Longer Offered by New South Window Solutions. See FL-16842.13-R5 Florida Building Code version 2017 for Historical Documents regarding this Approval. 16842.14 I n. DuraGard Slider XX Installation Instructions FL16842 R6 II Product Offerin S,L3),pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL16842 R6 AE Product Offering _(.13),pdf Created by Independent Third Party: Yes Extruded Vinyl "Non -Impact" Horizontal Sliding Window (XX, configuration) Limits of Use Installation Instructioru Approved for use in HVHZ: No FL16842 R6 II Product (21;fering-k,1-4).af Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: This Product is No Longer Offered by New South FL16842 R6 AE Product Offering L14_1p�t Window Solutions, See FL-16842.14-R5 Florida Building Code Created by Independent Third Party: Yes version 2017 for Historical Documents regarding this Approval. 16842.15 o. DuraGard - 3 Slider XOX Extruded Vinyl "Non -Impact" Horizontal Sliding Window utilizing a Nall Fin Installation (XOX, configuration) Limps of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: This Product is No Longer Offered by New South Window Solutions. See FL-16842.15-R5 Florida Building Code version 2017 for Historical Documents regarding this Approval. 16842.16 1 p. DuraGard - 3 Slider XOX Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: This Product is No Longer Offered by New South Window Solutions. See FL-16842.16-RS Florida Building Code version 2017 for Historical Documents regarding this Approval. 16842.17 � q. Sashlite Slider XX Installation Instructions FL16842 R6 11 Product Offering ,j$j,W Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Patty: Yes Evaluation Reports FL16842 R6 AE Product Offering1,L5j,,p�f Created by Independent Third Party: Yes Extruded Vinyl "Non -Impact" Horizontal Sliding Window with Flange Installation (XOX, configuration) Installation Instructions FL16842 R6 11 Product Offering_(,j_¢, pdf Verified By: Lyndon F Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL16842 R6 AE Product Offering (.161df Created by Independent Third Party: Yes Extruded Vinyl "Non -Impact" Horizontal Sliding Window utilizing a Nall Fin Installation (XX, configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL16842 R6 II Product Offering�,�7j,p Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: This Product is No Longer Offered by New South FL16842 R6 AE Product Offeringj17),p Window Solutions. See FL-16842.17-R5 Florida Building Code Created by Independent Third Party: Yes version 2017 for Historical Documents regarding this Approval. , 16842.18 1 r. Sashlite Slider XX Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: This Product is No Longer Offered by New South Window Solutions, See FL-16842.18-R5 Florida Building Code version 2017 for Historical Documents regarding this Approval. 16842.19 s. Sashlite - 3 Slider XOX LAnks of Use Approved for use In HVHZ; No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: This Product is No Longer Offered by New South Window Solutions. See FL-16842.19-R5 Florida Building Code version 2017 for Historical Documents regarding this Approval, Extruded Vinyl "Non -Impact" Horizontal Sliding Window (XX, configuration) Installetion Instructions FL16842 R6 II Product_Qfferinn_(,M,Rz ff Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL16B42 R6 AE Product Offeringl.1y).off Created by Independent Third Party: Yes Extruded Vinyl "Non -Impact" Horizontal Sliding Window utilizing a Nall Fin Installation (XOX, configuration) Installation Instructions FL16842 R6 11 Product Offerng_(,a).Ut Verified By: Lyndon F Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL16842 R6 AE Product Offering (.19),pdi Created by Independent Third Party: Yes Di https:llwww.floridabuilding,org/prlpr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZQ761 FGu3AxBTPX3DcJTXeXQ%3d%3 d 4/5 12/8/2020 Florida Building Code Online Go to Page 0. 16842.20 I It. Sashlite - 3 Slider XOX Extruded Vinyl "Non -impact" Horizontal Sliding Window (XOX, configuration) Umlts of Use Installation Instructions Approved for use In HVHZ: Na FL16842 R6 II Product Offehn 1,2Q),pLff Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: This Product is No Longer Offered by New South FL16842 R6 AE Product Offerings 20),pdf Window Solutions. See FL-16842.20-R5 Florida Building Code Created by Independent Third Party: Yes version 2017 for Historical Documents regarding this Approval. 0 0 Page 1/ 2 0 a Contact U 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Coavriaht 2007-2013 State of Florida : Privacy Statement :: Acce$51billty Statement :: Refund Statement Under Florida taw, email addresses are public records. If you do not want your e-mail address released in response to a publlc-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. `Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an emall address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public, To determine M you are a licensee under Chapter 455, F,S., please dick here . Product Approval Accepts: ® W: I ® °' i Credit Card Safe https:IJwww.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxAp7_ZQ761FGu3Ax8TPX3Dc.lTXeXQ%3d%3d 5/5 '.NI alHri ...0 + a i OC :\ £IQ8 'ON KIWO-a3d8A Le IH'BSa'CLQ e MCC -u 'wul n 'OCL WB 'Old 'am 'SLN nnsN00 ONICnin9 Bv►C+ 'oN 'S'd kplwyas 'd UOPUA\ w w. 1-4 w.u+ea MON WWN39 ,P S38nS53Nd NDrS3a 'HOUV3U T#0k Al •A181'13iKtl Nfl 1Wd N w N k E a 31tl0 ON S- l OEU * 10t 'C3 H1S OL 3LM7dn sl 9Z 8 Jtl' IZY10 OOY if►N T300M 357A3 I Ll Zl W7^OSMoN lZrKKMd � N� O9lOL '63 Hl9 Ol 3LMOdf1 Ll ZZ 8 7• -rm Nu OZOL 'D3 H1L Ol 31YOd(I DZ L s ;wi :1&_ ow'De A^P EO►$t'ON — :' '�Z�LIII 111000 o a O 0 0% 4� h 6W'9'ZMI 1f1SM WZOV 2e89t _13\S6U, < ]WP9S IelumuoH Z"%,Ij18en ddy unMd WWII • V)LN3NvW113d LwOPulM LOOS m@N151u4�IDVq�\[O>P11 'ark m+ insNoo emanins 'M.W v LUZ C LOS 'ON XMl60ti 3dBd' Le l6'699'£ L6 !'ON wood qq 465CC ld '�F+IPA 'OCL �Lp9 '0'd SNOUO3S SSM �a'�NozlaaH -rrOILa3n l H " VL � w N ipl i e V4 ON 537 �B.i 4[OZ 'Q3 HIS 0, 3iY0df1 4L SL 9 L JFI1 'ONF 'S3Nd1�nSN0O 9N1Q7X16 •A�W35Stl i1O I1fVd Ht' NIZYi9 OOY r1i7V 73O0W 35Vt'32f SI Ll d1 i S31 NOILVO09 WHOW 'IW 03Q0V 8i 82 6 `0ijillijill /LL• .� T�-�O. Li dotcv 'eN '3'd fi!' oa. 0 '03 His 01 mv0d(F LL Z8 8 ',I4i} OB.d OZ0Z 'Q3 H!L UL 3landn OC L S ���,.• fI iPkw4e5 'd ucPu,(� �" �% 41��SMoN ��� ' • Fa Lid n ++ a -nnooad T 23 ow woe /qrr 6o►er •oN ` r � �.�� �O HJS N do V taut 'Iwa NIW.iII l llf11F1114ti .Z U tuu. r O ^ .. N • � � M N A�LLL W � W o � C O 1 n L� W � � •� • N • O E r N � H �y z V �m u M $� Y .4 ^ N N �! H H hi V 0 0= r Wx yHy� y2 ` fS � pp12 \ 1 V U N y _ ° m � N 06 t3 HIPD + •• W CC •o A GCb Z [J of bM"7ML-lMH (=Z) ZML-I:f txiw0 - WOp4S MUMUGH ZML-I:AsleAojddv Unpad epuold - YLLN3NVWN3d -OPWM W OS "NVWD!1510 w LVM 'ONI a MoNco OWOC lRO Ww 416E 0 £ M -ON AAWFBVtl 3d9d' SND[f.��$ � a T/1NOZRfOH W 7tDUd3M1 469fi '3d 'WNI°A 'D£L -6 '0'd � � � N ,*Ni 's1NVl-insNoo ownins - " �� '-A19 Y lva q Z �SI \{tll r! I {, Wiwe ss 'A U � 4i+a5raN Cq %` Va W wde+d ewm~0 '.ianooad a M € R dC omz 'os 'N14N.i1!'l z M • is M M i 0 M M ..r G w C ig Pi � PI m N s7 s1 W W a p° C C4 V t V If1 • � • ° � c N � t C cy ME y V dY z E u� �- M �a � M F o ca h w W z� W x NP7 Z Z U0 �0 &�o im .+ N vv a ~ z yeti •- M ` u :i „ 1-6 ON Sit oae 6i0Z '03 1r[5 0l 31VOdR s[ sl 1 xr aov rrvr[ zaaow s[ [ a z SdT NOLL 1 8[ 9Z 6 £ )FI' �H! L[OZ 'W [i19 Ol 3LVl7dR LI e i aw � ozaz •W H11 41 3cvpdn az os c s 6MP5'iYS91-1i15U lUiozl z4B9L-lils$uu+aip - JWP!5leiuoxuaH iY69L-ldls!enoAddy unpad ¢P?+a13 - VLLN3NVWil3d sMoPu!M 47no5 —N153ue!!JU9^J1[0aP11 ,.M R1N-. -5-00 ONIO-8 -m-w Y Luz CM 'ON FJP15O21 3dej' jNIHOHONY SN I ] a LBL6'BCOTL6 ='aN aO4d J.B 31VO ON m ...I �1�1 3 zone yg9M 'U 'o VFPA 'OCZ -" '0'd ,pl-�/+ Si'7 08� 4l QL 'Q3 H1S 01 31.YOdfi 5'! SZ 9 ! vi x � 'ONt 'S1NYill15N00 ONIQ'71f19 J'!i(JIfJAlBW355Y JO llfld kP IZV79 OOV 3WVN l3QOW 35fA3N Sl Ll Z[ Z o� �' } '� a�0 �� r•LC+/'i� 60tifY aN '� d Sj l Nouvool OEU L 09 '03 HUS 01y31VQ� C L LL fi Z '�_�•``��993PP++4�6 '� �oW� yinoSraN 0'dU 36� OZOZ '03 H.[L Ol 31YQd11 OZ Of C ••�••••� �. P�roLud R0 :13f1008d 0 o='os 4nr i�i��'11rFfJ$tL�t� S'dlli NJ z l IIII �I zi W Q W 7 z zN N 'nvw JR I to Y CG4L � w� LL P 'x c 8_gg ti U P t - WUNINVOW WO4� 'OHI —vain—vm ONI6lMB 'M'tl b I OZ £196 'ON "Doti 3dBi' 51N3MOdrro� L6t6'699'£L9 %pN &ueyd ON r b tq 969££ id 'COi�[DA 'OaKO8 'O'd A /a Sil ou rioz •m His of �.mdn 914909 1 y a 'ONI 'SIWI-InSNO'J ONIMMS CJJU .'),-MrGWV HO iWd LNg 0W 1.30fN"f 3SIA3if l 1 Zl Z a z ♦♦`��till_ III1���Z / N .-NA MICNQ Y W 91 HL 6 £ 4'�I ♦ 'jr �• e0i£► 'oN '3'd kP Diu o '03 H" CU 31KMn Ll ZL 6 ♦ N t ! ♦♦ ♦ ��i WIu+4�5 'q uopuA43nogNPN m 58u OLOZ '03 H1L Ol 3lvudn S3 a Ozaa 'oe Amr GDM'°H - f'rwilJB%ti,%% .LY 4 c o acro 0 Q m JOT 46'o Ey .6L 1 o 1 UiJ ,sL' � M .9i0 o z W n hull c' O� P'9'Z"91-13 U ZDZ Z49 -% IMgJO - 7 aRIS ILqU07poH ZMI-ld\SIEAbjddV 7MPad tPucnl - N3NVHN9d auoPU!M 4lnOS AQ D kWP1\ ".SNP i1NVllfIYHO•.j mmici a -M-y b l OZ £LOB 'ON Z+NIbem 3dSd' SIM343 SNIZV79 Ow N 1 SOAN �0 lil8 I OWSSO'£LO -ON w514921311?Y eyd 3LVa ON r co Ipl G64££ U 'GOIJIIDA '0£Z NOB 'O'd �},� Sil tiOL '433 HIS 01 2LVGdR Si SZ 9 ! '3NI 'S.LNV1lnSNW ONIMMS (1J `,klHV 'W NO �d rr 2M OGV 3iriN T3M 3SM41 Si L2 Z! Z Li '03H HLV SZ Ol 31Yddn L L 8 ! N, �� i� ap!wyo6 .d uePu,C� 4#neSMoN J1'0 'jgj OZOL '03 H1L 01 31Ytld(i 0Z 0£ L O Ci .•tijpYlOjlj'•. S �i .,IG d gO�urroea "12ncl0i1d C oewos Am 3 iaR= 111111 NI11IL1� m °C N o o 10 D to F z Z Qm {TJ U z a0 LU cd O� W a� xi p 0 z� 3S �O O Q` U U O W p W N a oWc Q� w� 9 6MP'9ZML-VSN (OZOZ) ZML-I.AOUINRJ(3 - ]UaPIi5 InuomOH zm9f-Id\SIEnOaddy Phpwd eppold - V11N3NVWM3d fmOPO!M 4L^OS NAMSwa!I]v9A+1Ll � � W �y0.4lL�aCQ nn��00dO(.rQp�a�rQyy Q QQQQ c 4 O C �u z z w O HaO pc7�U' a ae U O�u�� sms ��m � UO=� EO �Q ��, Edpppbm"_' W C7C7Y nw '�1 Z� ZN �ztl0 n'W 4Y � �d Z�n� ��n,,. hoc �oc��iry � U �N�Q � x Ox a_x»>Ooc w scZo3 U Y=�sz❑7� � ���x����xocviocQaQi3 CD UO W �Y P\1 R W R W Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry C P 0 Box 234 Valrico, FL 33595 Phone 813.659.9197 Flonda Board or Professional Engineers Registry Liccnse No. 9913 Product Sub Category Manufacturer Product Name Category NewSouth Window Solutions Series 9000 Model 9550 Slider XO Windows Horizontal Slider 10741 Crossroads Commerce Blvd. Impact Rated - HVHZ Tampa, FL 33610 w! Flange 813 626-6000 Scope: Product Evaluation report issued by R W Building Consultants, Inc & Lyndon F Schmidt, P.E. (System ID # 1998) for NewSouth Window Solutions, based on Rule Chapter No. 61 G20-3, Method 10 of the State of Florida Product Approval, Dept. of Business & Professional Regulation, RW Building Consultants and Lyndon F, Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 7th Edition (2020) Florida Building Code (FBC) including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the "HVHZ", this product complies with Section 1626 of the FBC and does not require an impact resistant covering 4. When used in areas outside of the "HVHZ' requiring wind borne debris protection, this product complies with Section 1609.1.2.2 & R301.2 1 2 1 of the FBC and does not require an impact resistant covering. This product meets missile level "0" and includes Wind Zone 4 as defined in ASTM E 199E and FBC Sections 1609.1.2.2 & R301.2.1.2.1. 5 For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction 6 Site conditions that deviate from the details of drawing FL-16842.E require further engineering analysis by a licensed engineer or registered architect. 7. This product meets water infiltration requirements for "HVHZ". 8. See drawing FL-16842 6 for size and design pressure limitations. Supporting Documents: 1 Test Report No. TEL 02031488 TEL 02031489 TEL 02031566 2 Miaml Dade NOA 18-0301.05 3 Drawing No. No. FL-16842.6 4 Calculations Anchoring ASTM E1300 Glass Load Test Standard TAS 201, 202, 203-94 TAS 201. 202, 203-94 TAS 201, 202. 203-94 Materials Testin Testing Laboratory Testing Evaluation Lab. Testing Evaluation Lab Testing Evaluation Lab. Signed by William B Shelton, P.E. William B Shelton, P E. William B Shelton, P.E. Saflex" PVB Interlayer (Eastman Chemical Co.) Prepared by ,%O11111111lll, Signed & Sealed by RW Building Consultants. Inc (#9813) �� �, SCHM/0! F.. Lyndon F. Schmidt, P E. Prepared by ���� ~'�,��'�NSF ��� Signed & Sealed by RW Building Consultants, Inc. (#9813) No 43409 Lyndon F. Schmidt, P.E. Lyndon F. Schmidt, P F 5 Quality Assurance =-3 1. Certificate of Participation issued by National Accreditation and STAT E O O . Lyndon F. Schmidt, P.E. Management Institute, certifying that NewSouth Window Solutions is 11.1� ,�'•,�� 9 P:� ���� FL PE Na. 4340s manufacturinwith ISOIlEC9 products020 and Gthin a uide 53uality assurance program t8heetolnof1ls ',�f19 . / O �••' ��`, 8r3/202a ,,j�s��irir+3 t-.%