Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method I Project Name: Lot 24 Block 5 Waterstone 1635 BGR Builder Name: ADAM HOMES Street: 5364 Vespera Street Permit Office: I City, State, Zip: Fort Pierce, FL , 34951 Permit Number: I Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type$1573.15 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block Int Insul, Exterior R=4.1 1399.30 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent c. N/A R=13.0 174.22 ft2 R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (1635.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1635.00 ft2 6. Conditioned floor area above grade (ft2) 1635 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A I R= ft2 7. Windows(204.8 sqft.) Description Area 12. Ducts R ft2 a. U-Factor: Dbl, U=0.33 152.55 ft2 a. Sup: Attic, Ret: Main, AH: Main 6 327 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 18.33 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.31 a. Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl, U=0.55 17.78 ft2 SHGC: SHGC=0.70 Area Weighted Average Overhang Depth: 1.825 ft. 14. Heating systems i kBtu/hr Efficiency Area Weighted Average SHGC: 0.276 a. Electric Heat Pump 28.2 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 40 gallons 9. Floor Types (1635.0 sqft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 1635.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.125 Total Proposed Modified Loads: 55.16 PASS Total Baseline Loads: 55.67 I hereby certify that the plans ifications covere Re w of the plans and � S-r . this calculation are in corn it the Flo ' nergy specifications covered by this 0 Code. calculation indicates compliance with the Florida Energy Code. .a r' PREPARED BY: ..,. Before construction isicompleted r DATE: 1712-15-901 Winn Kenmany this building will be inspected for l; X compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes.. with the Florida �Re de. OWNER/AG �-- BUILDING OFFICIAL: DATE: DATE: I - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (111402.4.1.2). 2/15/2021 8:48 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4 .-.A FORM R405-2020 INPI IT CI IMIIAAOV rucr►lri 10-r oconn-r PROJECT Title: Lot 24 Block 5 Waterstone 16 Bedrooms: 4 Address Type: Lot Information Building Type: User Conditioned Area: 1635 Lot # 24-5 Owner Name: Total Stories: 1 Block/Subdivision: Waterstone # of Units: 1 Worst Case: No PlatBook: Builder Name: ADAM HOMES Rotate Angle: 0 Street: 5364 Vespera Street Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Detached FL, 34951 New/Existing: New (From Plans) Comment: CLIMATE / V Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Win;ter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 1635 15859.5 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1635 15859.5 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 158.9 ft 0 1635 ft2 ---- 0.29 0 0.71 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1828 ft2 408 ft2 Medium N 0.85 N 0.85 No 0 26.57 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1635 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1635 ft2 0.11 Wood 2/15/2021 8:48 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS \Z # Ornt Adjacent Space Cavity Width Heightl To Wall Type- Sheathing Framing Solar Below o 1 S Exterior Concrete Block - Int Insul Main 4.1 43 1 8 11 384.2 ftz 0 0 0.6 0 2 W Exterior Concrete Block - Int Insul Main 4.1 17 1 10 8 182.2 ftz 0 0 0.6 0 3 N Exterior Concrete Block - Int Insul Main 4.1 45 5 10 8 484.4 ft2 0 0 0.6 0 4 E Exterior Concrete Block - Int Insul Main 4.1 32 8 10 8 348.4 ft2 0 0 0.6 0 5 - Garage Frame - Wood Main 13 16 4 10 8 174.2 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated Main None .25 3 6 8 20 ft' 2 - Wood Main None 25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang 1/ # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Areal Depth Separation Int Shade Screening 1 S 1 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft' 1 ft 4 in 0 ft 10 in Drapes/blinds None 2 W 2 Vinyl Low-E Double Yes 0.33 0.31 N 5.0 ft2 1 6 ft 9 in 2 ft 6 in Drapes/blinds None 3 W 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft? 1 ft5 in 0 ft10 in Drapes/blinds None 4 W 2 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ftz 6 ft 9 in 4 ft 0 in Drapes/blinds None 5 N 3 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None 6 N 3 Vinyl Low-E Double Yes 0.33 0.23 N 64.8 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None 7 E 4 Metal Low-E Double Yes 0.55 0.7 N 17.8 ft? 1 ft 4 in 1 ft 0 in Drapes/blinds None 8 E 4 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft4 in 0 ft 10 in Drapes/blinds None 9 E 4 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ftZ1 1 ft 4 in 0 ft 10 in Drapes/blinds None GARAGE i # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 400 ft2 400 ftZ 64 ft 8 ft 1 INFILTRATION # Scope I Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000431 1850.3 101.51 . 190.58 .1365 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 29.2 kBtu/hr 1 sys#1 2/15/2021 8:48 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 4 I FORM R405-2020 INPUT SUMMARY CHECKLIST RFpnPT COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 28.4 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM i # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal, I 120 deg None SOLAR HOT WATER SYSTEM I FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 327 ft2 Main 81.75 ft Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling an Heating Jan Feb X Feb HMa r Mar Apr Appr Jul May Jun Jul May ri Jun rl lug Au ri Sep Se ri Oct Oct Nov Nov HX Dec Dec H Venting Jan [ Feb Mar [ Apr [ May JunJul Aug Se [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 I 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 Oft 0.3 Main 2/15/2021 8:48 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. 5364 Vespera Street, Fort Pierce, FL, 34951 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows- Description a. U-Factor: Dbl, U=0.33 SHGC: SHGC=0.23 b. U-Factor Dbl, U=0.33 SHGC: SHGC=0.31 c. U-Factor: Dbl, U=0.55 SHGC: SHGC=0.70 d. U-Factor: other (see details) SHGC: other (see details) Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A New (From Plans) 10. Wall Type and Insulation Detached a. Concrete Block -, Int Insul, Exterior b. Frame - Wood, Adjacent 1 c. N/A 4 d. N/A No 11. Ceiling Type and insulation level a. Under Attic (Vented) 1635 b. N/A Area c. N/A 152.55 ft2 12. Ducts, location & insulation level a. Sup: Attic, Ret: Main, AH: Main 18.33 ft2 13. Cooling systems 17.78 ft2 a. Central Unit 16.19 ft2 1.825 ft. 0.276 Area ft2 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 1635.00 ft2 b. N/A R= ft2 c. N/A R= ft2 14. Heating systems a. Electric Heat Pump 15. Hot water systems, a. Electric I b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: City/FL Zip: Insulation Area R=4.1 1399.30 ft2 R=13.0 174.22 ft2 R= ft2 R= ft2 Insulation Area R=30.0 1635.00 ft2 R= ft2 R= ft2 R ft2 6 327 kBtu/hr Efficiency 28.4 SEER:15.00 kBtu/hr Efficiency 28.2 HSPF:8.50 Cap: 40 gallons EF: 0.94 Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not. DEFAULT. 2/15/2021 8:48 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1