HomeMy WebLinkAboutPlumbing Plan#8 Solid copper
wire w/ Appr
clamps(!.o ane
side of pool-4 t
(1) #8 Bare copper wire
bonded to pool steel as
shown
EOUOPOTENTIAL N.T.S
BONDING DETAIL
Per FL Build Code Adaptation of
N.E.C. 2008 sec680.26
WP Manual Starter
Separate Circuit swnc typ) Time Clock
for motor and light
GFI Panel
taker to,
pump WP GFI 10'.20 F
from water Pump Motor
r — — — — — I Footer 8'x8' W#5 R
SKR ......................
78n. Screen enclosure
3'6"
15'x32'
�
51 �� LIED g, R
fp
I I
V /f�ne R 23n. LED 3,611 15'x32' 23ft. 51 LED
R
R
• • Handral Vac/line o Ft
tL
Plumbing Plan
Specifications
Pool Dimensions: 15'x32' Area: 332Sq Ft Perimeter:85 LN FT.
Pool returns: 4• Vac Stub Out: Yes with Approved Vac Lock Pool Capacity: 11,608.44 gallons
Liaht: (2) 18 watt Savi Melody Total 18 Watt Skimmer: 2
Interior coating: Gem Coat
Decking: 1618 Sq Ft Concrete With 8ffx8" #5R Footer
Pump: Pentair Intelleflo VSP. @ 34 GPM Turnover Rate: 7 Hours
Chlorinator(Salt generator), Filter: Pentair 200 sq ft cartridge Clean and Clear
/00-0081
ST. LUCIE COUNTY BUILDING DIVISION
REVIEWED FOR C LIANCE
REVIEWED BY
PLANS AND PERMIT MUST BE KEPT ON JOB
OR NO INSPECTION WILL BE MADE.
2-hard coil T Nails 099
0.1 % ENE
Existing Wall
confine 2 16Dnail. (all Material)
tile
%"-3/8"
plaster
Wall Section Cantilever N.T.S
S.P.S.T. + Junction Box
Toggle
Po
Switch Light Ground all Metal boxes.(Iigh ,motogecu.(Savi Melody light hitch requires no ground) With
#8 wire (solid)
Light fixtures do not require ground fault interrupter
Electric Diagram N.T.S.
THESE PLANS AND ALL PROPOSED WORK
IaARE SUBJECT.TO ANY CORRECTIONS
REQUIRED BYIFIELD INSPECTORS THAT -
It.:'
affk NECESSAAY IN ORDER:TO
'GONJPLYWITH AIL' AP&!CA61ek_CODES,1
i
Specifications:
Aft m�
FILE CUP -My 1) PLANS AND ENGINEERING IN ACCORDANCE WITH THE FLORIDA BUILDING CODE RESIDENTIAL 2010,
ANSI/NSPI 3, ANSI/NSPI 4, ANSI/NSPA 5, ANSI/NSPI 6, and ANSI/APSP 7.
2) ALL CONSTRUCTION AND INSTALLATIONS TO COMPLY WITH THE FLORIDA BUILDING CODE RESIDENTIAL
2010, ANSI/NSPI 3, ANSI/NSPI 4, ANSI/NSPA S, ANSI/NSPI 6, and ANSI/APSP 7.
3) GUNITE / SHORECRETE TO BE 3000 PSI MINIMUM AT 28 DAY.
4) ALL STEEL SHALL BE GRADE 40 MINIMUM.
5) ALL PIPING SHALL BE SCH 40 OR SCH 80 PVC, AND INSTALLATIONS SHALL COMPLY WITH FBC PLUMBING
2010.
6) ALL POOL AND SPA SHALL HAVE CONTINUOUS SOIL BEARING ON CLEAN COMPACTED SOIL WITH 2O00 PSF
MINIMUM.
TYP 12' concrete or Paver deck 7} ALL HANDRAILS, LADDERS, LIGHTS SHALL BE BONDED WITH #8 GROUND WIRE PER NEC 650.
2500 PSI !borate $„ I Water Level 8) POOL AND SPA SHALL BE PROVIDED WITH APPROVED CHILD BARRIER OR SCREEN ENCLOSURE, HOUSE
Compacted fill —�
#3 Rebar 118 i I SAFTEY BARRIER OR ALARM SYSTEM ALL IN ACCORDANCE WITH FBCR 4101.17.1.
Bench Existing Slab a I
12" O.C. I 2" x a^ step 9} ALL GAS AND FUEL PIPING SHALL BE PER FBC FUEL AND GAS 2010 (SEPARATE CONTRACTOR).
� Edge � a' O � 8n 10" Edge I
Tile
Swim In Bench Detail
N.T.S.
Pump & Filter to be screwed down with 1.5 "
long 1/8 or larger approved concrete anchors..
Pump & Filter Tie Down N.T.S
Water line
4 inch
min to
lens
5 1/2"Plywood
Ly
8 Mill Polly
Molilture Barrier
Shoring Detail N.T.S.
12 volt
1" sch 40 transformer
pJ-Boxvc \
No
Needed
-
1.5 sch 40 PVC
I z
inch min 1.5" conduit
14
s ralg
No Bonding
needed
Light Detail SAVI MELODY
N.T.S.
1st step - i
(1) # 5 rebar e �l 10) ALL ELECTRICAL INSTALLATIONS SHALL BE IN ACCORDANCE WITH NEC 2008 EDITION.
or (2) #3 11) POOL AND SPA EQUIPMENT SHALL BE SECURED TO CONCRETE PAD.
rebar Undisturbed soil underneath / 2° or 1.5° PVC sch. 12) AFTER COMPLETION OF POOL CONSTRUCTION, HOMEOWNER SHALL CONSULT LISCENSED POOL
Tooter 40 CONTRACTOR IN ORDER TO DRAIN POOL IF SO DESIRED.
Continuous Pump Suction Side
Steps N.T.S. 13) HEATING EQIUPMENT SHALL COMPLY WITH FBCR 4101.14
Footer Detail N.T.S. Skimmer Detail N.T.S.
Total pool Length
Typical section through POOL N.T.S.
11
Cuts de al f 5t andfrlh -4"thick w/#3
REBAFt @ 12' O/C each way
3 FT to 5 F .6" Thick w/#3 Rebar06" O/C each way
0 FT10 3 FT-&' Thii k w/43 Rebarod 6" O/C each way
le Of
5 Reposge N.T.S.
'Excavation of angle of repose is allowed providing
1, Shoring is installed on excavated surfaces sufficient io secure soil from
erosion or settlement,
2.No Undermining owurs,if undermining occurs cohsuli a design professional
3.Compackon test ofthe backfilled material are provided at Q.O. of the pool
POOIS B Reed Sudderth
y 4240 MC Carty Rd.
Vitali,INC Fort Pierce. Ft 34945
Do not duplicate - This
drawing is the property of
Pools By Vitali,INC.
(Family Pools Inc) and may State Lie.# CPC 1458526
be purchased separately for PAGE I DEPT DESIGNER REV
$250. No duplication allowed. Vitali Bederak
Violators may be prosecuted. SCALE 1 /8" - 1' SHEET 1 OF 1
PAUL WELCH INC.
MECHANICAL ♦.ELECTRICAL . CIVIL ENr31NEERING
1984 SW BILTMORE ST - SUITE # 1 1 4
PORT ST.'LUCIE, FL 34984
PHONE: E-MAIL FAX
(772)795-9888 PVvELCHINC@¢ACL.CCM 1772)785-9922
PAUL WELCH, P.E., FL REIS. No. 29945
12014