Loading...
HomeMy WebLinkAboutPlumbing Plan#8 Solid copper wire w/ Appr clamps(!.o ane side of pool-4 t (1) #8 Bare copper wire bonded to pool steel as shown EOUOPOTENTIAL N.T.S BONDING DETAIL Per FL Build Code Adaptation of N.E.C. 2008 sec680.26 WP Manual Starter Separate Circuit swnc typ) Time Clock for motor and light GFI Panel taker to, pump WP GFI 10'.20 F from water Pump Motor r — — — — — I Footer 8'x8' W#5 R SKR ...................... 78n. Screen enclosure 3'6" 15'x32' � 51 �� LIED g, R fp I I V /f�ne R 23n. LED 3,611 15'x32' 23ft. 51 LED R R • • Handral Vac/line o Ft tL Plumbing Plan Specifications Pool Dimensions: 15'x32' Area: 332Sq Ft Perimeter:85 LN FT. Pool returns: 4• Vac Stub Out: Yes with Approved Vac Lock Pool Capacity: 11,608.44 gallons Liaht: (2) 18 watt Savi Melody Total 18 Watt Skimmer: 2 Interior coating: Gem Coat Decking: 1618 Sq Ft Concrete With 8ffx8" #5R Footer Pump: Pentair Intelleflo VSP. @ 34 GPM Turnover Rate: 7 Hours Chlorinator(Salt generator), Filter: Pentair 200 sq ft cartridge Clean and Clear /00-0081 ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR C LIANCE REVIEWED BY PLANS AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE. 2-hard coil T Nails 099 0.1 % ENE Existing Wall confine 2 16Dnail. (all Material) tile %"-3/8" plaster Wall Section Cantilever N.T.S S.P.S.T. + Junction Box Toggle Po Switch Light Ground all Metal boxes.(Iigh ,motogecu.(Savi Melody light hitch requires no ground) With #8 wire (solid) Light fixtures do not require ground fault interrupter Electric Diagram N.T.S. THESE PLANS AND ALL PROPOSED WORK IaARE SUBJECT.TO ANY CORRECTIONS REQUIRED BYIFIELD INSPECTORS THAT - It.:' affk NECESSAAY IN ORDER:TO 'GONJPLYWITH AIL' AP&!CA61ek_CODES,1 i Specifications: Aft m� FILE CUP -My 1) PLANS AND ENGINEERING IN ACCORDANCE WITH THE FLORIDA BUILDING CODE RESIDENTIAL 2010, ANSI/NSPI 3, ANSI/NSPI 4, ANSI/NSPA 5, ANSI/NSPI 6, and ANSI/APSP 7. 2) ALL CONSTRUCTION AND INSTALLATIONS TO COMPLY WITH THE FLORIDA BUILDING CODE RESIDENTIAL 2010, ANSI/NSPI 3, ANSI/NSPI 4, ANSI/NSPA S, ANSI/NSPI 6, and ANSI/APSP 7. 3) GUNITE / SHORECRETE TO BE 3000 PSI MINIMUM AT 28 DAY. 4) ALL STEEL SHALL BE GRADE 40 MINIMUM. 5) ALL PIPING SHALL BE SCH 40 OR SCH 80 PVC, AND INSTALLATIONS SHALL COMPLY WITH FBC PLUMBING 2010. 6) ALL POOL AND SPA SHALL HAVE CONTINUOUS SOIL BEARING ON CLEAN COMPACTED SOIL WITH 2O00 PSF MINIMUM. TYP 12' concrete or Paver deck 7} ALL HANDRAILS, LADDERS, LIGHTS SHALL BE BONDED WITH #8 GROUND WIRE PER NEC 650. 2500 PSI !borate $„ I Water Level 8) POOL AND SPA SHALL BE PROVIDED WITH APPROVED CHILD BARRIER OR SCREEN ENCLOSURE, HOUSE Compacted fill —� #3 Rebar 118 i I SAFTEY BARRIER OR ALARM SYSTEM ALL IN ACCORDANCE WITH FBCR 4101.17.1. Bench Existing Slab a I 12" O.C. I 2" x a^ step 9} ALL GAS AND FUEL PIPING SHALL BE PER FBC FUEL AND GAS 2010 (SEPARATE CONTRACTOR). � Edge � a' O � 8n 10" Edge I Tile Swim In Bench Detail N.T.S. Pump & Filter to be screwed down with 1.5 " long 1/8 or larger approved concrete anchors.. Pump & Filter Tie Down N.T.S Water line 4 inch min to lens 5 1/2"Plywood Ly 8 Mill Polly Molilture Barrier Shoring Detail N.T.S. 12 volt 1" sch 40 transformer pJ-Boxvc \ No Needed - 1.5 sch 40 PVC I z inch min 1.5" conduit 14 s ralg No Bonding needed Light Detail SAVI MELODY N.T.S. 1st step - i (1) # 5 rebar e �l 10) ALL ELECTRICAL INSTALLATIONS SHALL BE IN ACCORDANCE WITH NEC 2008 EDITION. or (2) #3 11) POOL AND SPA EQUIPMENT SHALL BE SECURED TO CONCRETE PAD. rebar Undisturbed soil underneath / 2° or 1.5° PVC sch. 12) AFTER COMPLETION OF POOL CONSTRUCTION, HOMEOWNER SHALL CONSULT LISCENSED POOL Tooter 40 CONTRACTOR IN ORDER TO DRAIN POOL IF SO DESIRED. Continuous Pump Suction Side Steps N.T.S. 13) HEATING EQIUPMENT SHALL COMPLY WITH FBCR 4101.14 Footer Detail N.T.S. Skimmer Detail N.T.S. Total pool Length Typical section through POOL N.T.S. 11 Cuts de al f 5t andfrlh -4"thick w/#3 REBAFt @ 12' O/C each way 3 FT to 5 F .6" Thick w/#3 Rebar06" O/C each way 0 FT10 3 FT-&' Thii k w/43 Rebarod 6" O/C each way le Of 5 Reposge N.T.S. 'Excavation of angle of repose is allowed providing 1, Shoring is installed on excavated surfaces sufficient io secure soil from erosion or settlement, 2.No Undermining owurs,if undermining occurs cohsuli a design professional 3.Compackon test ofthe backfilled material are provided at Q.O. of the pool POOIS B Reed Sudderth y 4240 MC Carty Rd. Vitali,INC Fort Pierce. Ft 34945 Do not duplicate - This drawing is the property of Pools By Vitali,INC. (Family Pools Inc) and may State Lie.# CPC 1458526 be purchased separately for PAGE I DEPT DESIGNER REV $250. No duplication allowed. Vitali Bederak Violators may be prosecuted. SCALE 1 /8" - 1' SHEET 1 OF 1 PAUL WELCH INC. MECHANICAL ♦.ELECTRICAL . CIVIL ENr31NEERING 1984 SW BILTMORE ST - SUITE # 1 1 4 PORT ST.'LUCIE, FL 34984 PHONE: E-MAIL FAX (772)795-9888 PVvELCHINC@¢ACL.CCM 1772)785-9922 PAUL WELCH, P.E., FL REIS. No. 29945 12014