Loading...
HomeMy WebLinkAbout212254-1d Compaction - signed.pdfHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net DATE TESTED:KSM JOB #:212254-1d/MH/bm PERMIT #:NUC #630 CONTRACTOR:Homecrete Homes Nuc Model:MC-1DR-P JOB LOCATION:109 NE Charleston Oaks Drive Nuc Serial #:30630 Port St Lucie, Florida ITEM TESTED:Compacted Foundation Fill - House Pad TEST LOCATION OF SAMPLE DEPTH PEN READ DRY DENSITY MAX. DRY PROCTOR VALUE (P.C.F) PERCENT COMPACTION 1. N.W.0" - 12"50 109.5 111.8 97.9% 2. N.E."50 110.0 "98.4% 3. Center "50 111.4 "99.6% 4. S.W."50 108.3 "96.9% 5. S.E."50 110.4 "98.7% Soil Description: Brown Sand with Shell Fragments In Place Moisture: 8.3% Proctor Optimum Moisture: 12.0% Proctor Max. Dry Density: P.C.F. 111.8 @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets Minimum Requirement for Unstaked Foundation Respectfully Submitted: Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 3/25/2021 Email to: mshowman@homecretehomes.com Proudly Serving Florida since 1990 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 March 24, 2021 2012-0062 Disclaimer:Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the tested area has been altered from the approved inspected condition. 109.0 110.0 111.0 112.0 10 11 12 13 14 W E I G H T P . C . F . D R Y Moisture -% of Dry Weight