Loading...
HomeMy WebLinkAboutCompaction - signed.pdfHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net DATE TESTED:KSM JOB #: 212255-1d/MH/bm PERMIT #:NUC #630 CONTRACTOR:Edward Joyce Nuc Model:MC-1DR-P JOB LOCATION:5513 Pine Tree Drive Nuc Serial #:30630 Ft Pierce, Florida ITEM TESTED:Compacted Foundation Fill - Detached Garage TEST LOCATION OF SAMPLE DEPTH PEN READ DRY DENSITY MAX. DRY PROCTOR VALUE (P.C.F) PERCENT COMPACTION 1. S.W.0" - 12"50 112.3 114.7 97.9% 2. Center "50 113.8 "99.2% 3. N.E."50 112.9 "98.4% Soil Description: Brown Sand with Traces of Shell & Clay In Place Moisture: 6.2% Proctor Optimum Moisture: 12.0% Proctor Max. Dry Density: P.C.F. 114.7 @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets Minimum Requirement for Unstaked Foundation Respectfully Submitted: Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 3/25/2021 Email to: edjoycecitadel@aol.com SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 March 24, 2021 2102-0134 Disclaimer:Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the tested area has been altered from the approved inspected condition. Proudly Serving Florida since 1990 112.0 113.0 114.0 115.0 10 11 12 13 14 W E I G H T P . C . F . D R Y Moisture -% of Dry Weight