Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2014 , I FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION 'r - Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Standard Pacific RB Wentworth Lot 21 Builder Name: Standard Pacific Homes Street: 310 S AAA) (�OC����, � -) Permit Office: Port St Lucie City, State�Zip: Port St Lucie , FL , Permit Number: Owner: Standard Pacific Homes Jurisdiction: 461100 Design Location: FL, Fort Pierce i 1. New construction or existing New (From Plans) 9. Wall Types (6556.9 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 6023.40 ftz b. Frame - Wood, Adjacent R=11.0 373.45 ftz 3. Number of units, if multiple family 1 c. Concrete Block - Int Insul, Adjacent R=4.1 160.05 ftz 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (3300.0 sqft.) Insulation Area a. Under Attic (Vented) R=38.0 3300.00 ftz 6. Conditioned floor area above grade (ftz) 5903 b. N/A R= ftz Conditioned floor area below grade (ftz) 0 ! c. N/A R= ftz 11. Ducts R ftz 7. Windows(931.2 sqft.) Description Area a. Sup: AC 1 Club Room Living Room Bed, Ret: AC 6 175 a. Lf-Factor: Sgl, U=1.07 414.07 ftz b. Sup: Attic, Ret: AC 2 Family Kitchen Dining Foy, 6 150 ,SHGC: SHGC=0.30 c. Sup: Attic, Ret: Attic, AH: AC 3 Second Floor 6 275 b. 'U-Factor: Sgl, U=1.00 258.99 ftz 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a. Central Unit 30.0 SEER:14.00 b. Central Unit 45.5 SEER:14.00 c. U-Factor: Sgl, U=1.05 240.00 ftz c. Central Unit 41.0 SEER:14.00 SHGC: SHGC=0.28 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 18.18 ftz a. Electric Heat Pump 29.6 HSPF:8.20 SHGC: other (see details) i b. Electric Heat Pump 45.0 HSPF:8.20 Area Weighted Average Overhang Depth: 7.566 ft. c. Electric Heat Pump 38.5 HSPF:8.20 Area Weighted Average SHGC: 0.301 14. Hot water systems 8. Floor Types (3300.0 sqft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 3300.00 ftz b. Conservation features EF: 0.920 b. N/A R= ftz None c. N/A R= ftz 15. Credits Pstat Glass/Floor Area: 0.158 Total', Proposed Modified Loads: 152.56 PASS Total Baseline Loads: 153.09 i I hereby certify that the plans and specifications, covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this s 0 Code. Digitally signed by Chris Wildroudt cn=Chris u=us, Chris calculation indicates compliance o=E Air, LLCt, o=Engineered Air, LLC, ou=New AConstructionSales with the Florida Energy Code. gy PREPARED BY: and ngmeenng, -DATE: Before construction is completed �emalt stldsw@engineeredairlls. I A f_O�esigned, this building will be inspected for " , Corn 1 � ,. Date: 2015.09.15 13:66:12-04'00' compliance with Section 553.908 Florida Statutes.I s * � hereby certify that this building, as isi, in compliance with the Florida Energy Code. 1) WE OWNER/AGENT: BUILDING OFFICIAL: DATE: k1 Zv 1 DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. r 9/15/2015 1:54 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2014 PROJECT Title: Standard Pacific RB Wentwor Bedrooms: 4 Address Type: Lot Information Building Type: User Conditioned Area: 5903 Lot # 21 Owner: Standard Pacific Homes Total Stories: 2 Block/SubDivision: Riverbend # of Units: 1 Worst Case: No PlatBook: Builder Name: Standard Pacific Homes Rotate Angle: 0 Street: Permit Office: Port St Lucie Cross Ventilation: County: St. Lucie Jurisdiction: 461100 Whole House Fan: City, State, Zip: Port St Lucie , Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ST_LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Blockl 1465 15631.5 2 Block2 1835 26142.3 3 Block3 2603 24286 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 AC 1 Club Room Li 1465 15631.5 No 3 1 1 Yes Yes Yes 2 AC 2 Family Kitche 1835 26142.3 Yes 3 0 1 Yes Yes Yes 3 AC 3 Second Floor 2603 24286 No 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio AC 1 Club Room 173 ft 0 1465 ft2 _--- 0 0 1 2 Slab -On -Grade Edge Insulatio AC 2 Family Kitch 183 ft 0 1835 ft2 ---- 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Barrel tile 3574 ft2 0 ft2 Light 0.6 No 0.75 No 38 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 3300 ft2 N N 9/15/2015 1:54 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2014 CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) AC 2 Family Kitch 38 697 ft2 0.11 Wood 2 Under Attic (Vented) AC 3 Second Flo 38 2603 ft2 0.11 Wood WALLS V # Ornt To Wall Type Adjacent p $ ace Cavity _ Width Height n Et In Area Sheathing Framing R_Valiia Frartlon Solar Qbcnr Below Grade%, 1 E Exterior Concrete Block - Int'InsAIC 1 Club Ro 4.1 9 0 10.67 0 96.0 ft2 0.3 0 0.3 0 2 S Exterior Concrete Block - Int InsAC 1 Club Ro 4.1 56 0 10.67 0 597.5 ft2 0.3 0 0.3 0 3 W Exterior Concrete Block - Int InsAIC 1 Club Ro 4.1 22 0 10.67 0 234.7 ft2 0.3 0 0.3 0 4 W Exterior Concrete Block - Int InsW 1 Club Ro i 4.1 29.5 0 10.67 0 314.8 ft2 0.3 0 0.3 0 5 N Exterior Concrete Block - Int InsW 1 Club Ro 4.1 14.5 0 10.67 0 154.7 ft2 0.3 0 0.3 0 6 N Exterior Concrete Block - Int Ins&C 1 Club Ro 4.1 14 0 10.67 0 149.4 ft2 0.3 0 0.3 0 7 E Garage Frame - Wood i AC 1 Club Ro 11 16 0 10.67 0 170.7 ft2 0.3 0 0.3 0 8 E Garage Concrete Block - Int InsW 1 Club Ro 4.1 6 0 10.67 0 64.0 ft2 0.3 0 0.3 0 9 S Garage Frame - Wood AC 1 Club Ro 11 6 0 10.67 0 64.0 ft2 0.3 0 0.3 0 10 E Exterior Concrete Block - Int InsAC 2 Family 4.1 12 0 10.67 0 128.0 ft2 0.3 0 0.3 0 11 E Exterior Concrete Block - Int InstAC 2 Family 4.1 12 0 10.67 0 128.0 ft2 0.3 0 0.3 0 12 E Exterior Concrete Block - Int I'hsAC 2 Family 4.1 9 0 10.67 0 96.0 ft2 0.3 0 0.3 0 _ 13 S Exterior Concrete Block - Int InSJ15iC 2 Family 4.1 18 0 21.67 0 390.1 ft2 0.3 0 0.3 0 14 W Exterior Concrete Block - Int IhstAC 2 Family 4.1 30 0 10.67 0 320.1 ft2 0.3 0 0.3 0 15 W Exterior Concrete Block - Int InstAC 2 Family 4.1 22.5 0 21.67 0 487.6 ft2 0.3 0 0.3 0 16 N Exterior Concrete Block - Int I,I s0iC 2 Family 4.1 19 0 21.67 0 411.7 ft2 0.3 0 0.3 0 17 N Exterior Concrete Block - Int InsiAC 2 Family 4.1 38.5 0 10.67 0 410.8 ft2 0.3 0 0.3 0 18 E Garage Concrete Block - Int InsAC 2 Family 4.1 9 0 10.67 0 96.0 ft2 0.3 0 0.3 0 19 E Garage Frame - Wood AC 2 Family 11 13 0 10.67 0 138.7 ft2 0.3 0 0.3 0 _20 E Exterior Concrete Block - Int InsW 3 Second 4.1 70 0 9.33 0 653.1 ft2 0.3 0 0.3 0 _21 S Exterior Concrete Block - Int InsAC 3 Second 4.1 59 0 9.33 0 550.5 ft2 0.3 0 0.3 0 _22 W Exterior Concrete Block- Int In sA C 3 Second 4.1 22 0 9.33 0 205.3 ft2 0.3 0 0.3 0 _23 W Exterior Concrete Block - Int InsAC 3 Second 4.1 29.5 0 9.33 0 275.2 ft2 0.3 0 0.3 0 _24 N Exterior Concrete Block - Int IHsAC 3 Second 4.1 45 0 9.33 0 419.9 ft2 0.3 0 0.3 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated AC 1 Club Ro None .4 2.7 8 21.4 ft2 WINDOWS - Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 E 1 Metal Low-E Single Yes 1.05 0.28 30.0 ft2 10 ft 0 in 2.67 ft 0 i None None 2 E 1 Metal Low-E Single Yes 1 0.32 9.0 ft2 7 ft 0 in 1 ft 0 in None None 3 S 2 Metal Low-E Single Yes 1 0.32 13.3 ft2 1 ft 0 in 14.5 ft 0 i None None 4 S 2 Metal Low-E Single Yes 1.07 0.3 61.6 ft2 10 ft 0 in 14.5 ft 0 i None None 5 S 2 Metal Low-E Single Yes 1.07 0.3 9.2 ft2 1 ft 0 in 14.5 ft 0 i None None 9/15/2015 1:54 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2014 WINDOWS Orientation shown is the entered, Proposed orientation. . / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 6 W 4 Metal Low-E Single Yes 1.07 0.3 18.4 ft2 13.5 ft 0 i 2 ft 0 in None None 7 W 4 Metal Low-E Single Yes 1.05 0.28 30.0 ft2 13.5 ft 0 i 2 ft 0 in None None 8 W 4 Metal Low-E Single Yes 1 0.32 35.0 ft2 13.5 ft 0 i 2 ft 0 in None None 9 N 5 Metal Low-E Single Yes 1.07 0.3 9.2 ft2 1 ft 0 in 14.5 ft 0 i None None 10 N 6 Metal Low-E Single ! Yes 1.05 0.28 30.0 ft2 29.5 ft 0 i 2 ft 0 in None None 11 E 10 Metal Low-E Single Yes 1 0.32 9.0 ft2 12 ft 0 in 1 ft 0 in None None 12 E 10 Metal Low-E Single Yes 1.05 0.28 30.0 ft2 12 ft 0 in 2.67 ft 0 i None None 13 E 11 Metal Low-E Single Yes 1 0.3 9.2 ft2 1 ft 0 in 1.33 ft 0 i None None 14 E 12 Metal Low-E Single Yes 1.05 0.32 9.0 ft2 7 ft 0 in 1 ft 0 in None None 15 E 12 Metal Low-E Single Yes 1.05 0.28 30.0 ft2 7 ft 0 in 2.33 ft 0 i None None 16 S 13 Metal Low-E Single Yes 1.05 0.28 30.0 ft2 29.5 ft 0 i 2 ft 0 in None None 17 W 14 Metal Low-E Single Yes 1.07 0.3 18.4 ft2 13.5 ft 0 i 2 ft 0 in None None 18 W 14 Metal Low-E Single Yes 1.05 0.28 30.0 ft2 13.5 ft 0 i 2 ft 0 in None None 19 W 14 Metal Low-E Single Yes 1 0.32 35.0 ft2 13.5 ft 0 i 2 ft 0 in None None 20 W 15 Metal Low-E Single Yes 1.07 0.3 61.6 ft2 1 ft 0 in 14.5 ft 0 i None None 21 W 15 Metal Low-E Single Yes 1 0.32 61.6 ft2 1 ft 0 in 8 ft 0 in None None 22 W 15 Metal Low-E Single Yes 1 0.32 61.6 ft2 1 ft 0 in 1.5 ft 0 in None None 23 N 16 Metal Low-E Single Yes 1.07 0.3 18.4 ft2 1 ft 0 in 14.5 ft 0 i None None 24 N 16 Metal Low-E Single Yes 1.07 0.3 18.4 ft2 1 ft 0 in 1.5 ft 0 in None None 25 N 17 Metal Low-E Single Yes 1.07 0.3 30.8 ft2 1 ft 0 in 14.5 ft 0 i None None 26 N 17 Metal Low-E Single Yes 1.07 0.3 18.4 ft2 1 ft 0 in 14.5 ft 0 i None None 27 E 20 Metal Low-E Single Yes 1.07 0.3 32.3 ft2 1 ft 0 in 1.5 ft 0 in None None 28 S 21 Metal Low-E Single Yes 1.07 0.3 9.2 ft2 1 ft 0 in 1.5 ft 0 in None None 29 S 21 Metal Low-E Single Yes 1.07 0.3 27.5 ft2 1 ft 0 in 1.5 ft 0 in None None 30 S 21 Metal Low-E Single Yes 1 0.32 25.0 ft2 1 ft 0 in 1.5 ft 0 in None None 31 S 21 Metal Low-E Single Yes 1 0.32 9.5 ft2 1 ft 0 in 1.5 ft 0 in None None 32 W 22 Metal Low-E Single Yes 1.07 0.3 48.5 ft2 1 ft 0 in 1.5 ft 0 in None None 33 W 23 Metal Low-E Single Yes 1.07 0.3 32.3 ft2 13.5 ft 0 i 1.5 ft 0 in None None 34 W 23 Metal Low-E Single Yes 1.05 0.28 30.0 ft2 13.5 ft 0 i 1.33 ft 0 i None None GARAGE # Floor Area Ceiling,Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 1005.984 ft2 1006,ft2 125 ft 10.67 ft 1 INFILTRATION # Scope Method I SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 5505 302.22 568.36 .3195 5 9/15/2015 1:54 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2014 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts y - 1 2 3 Electric Heat Pump Electric Heat Pump Electric Heat Pump Split Split Split HSPF:8.2 29.6 kBtu/hr HSPF:8.2 45 kBtu/hr HSPF:8.2 38.5 kBtu/hr 1 2 3 sys#1 sys#2 sys#3 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 3 Central Unit Central Unit Central Unit Split Split Split SEER: 14 30 kBtu/hr 1000 cfm 0.75 SEER: 14 45.5 kBtu/hr 1600 cfm 0.75 SEER: 14 41 kBtu/hr 1400 cfm 0.75 1 2 3 sys#1 sys#2 sys#3 HOT WATER SYSTEM # System Type SubType 'Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 50 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS # ---- Supply ---- Location R-Value Area ---- Return --- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 2 3 AC 1 Club Ro 6 175 ft2 Attic 6 150 ft2 Attic 6 275 ft2 AC 1 Club Ro 45 ft2 Default Leakage AC 1 Club (Default) (Default) AC 2 Family 15 ft2 Default Leakage AC 2 Famil (Default) (Default) Attic 60 ft2 Default Leakage AC 3 Secon (Default) (Default) 1 1 2 2 3 3 TEMPERATURES Programable Thermostat: Y Coolin Jan Feb Mar Heating Jan Feb Mar Ventin Jan Feb X Mar Ceiling Fans: Apr Ma rj JunJul rj Au �Xj Se Oct Apr MaY Jun Jul AuSep f Oct [X A r [ Ma Jun Jul Aug Se [X Oct [ ] Nov []Nov [X] Nov Dec Dec H Dec 9/15/2015 1:54 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2014 "Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 9/15/2015 1:54 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 6 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) - DISPLAY CARD " ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower thei EnergyPerformance Index, the more efficient the home. Port St Lucie, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 6023.40 ft2 b. Frame - Wood, Adjacent R=11.0 373.45 ft 3. Number of units, if multiple family 1 c. Concrete Block - Int Insul, Adjacent R=4.1 160.05 ft2 4. Number of Bedrooms 4 d. N/A R= i ft2 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=38.0 3300.00 ft2 6. Conditioned floor area (ft2) 5903 b. N/A R= ft2 7. Windows- Description Area c. R= ft 2 a. U-Factor: Sgl, U=1.07 Ducts 414.07 ft2 a. a. Sup: AC 1 Club Room Living Room Bed, Ret: AC R ft 6 175 SHGC: SHGC=0.30 b. Sup: Attic, Ret: AC 2 Family Kitchen Dining Foy, 6 150 b. U-Factor: Sgl, U=1.00 258.99 ft2 c. Sup: Attic, Ret: Attic, AH: AC 3 Second Floor 6 275 SHGC: SHGC=0.32 12. Cooling systems kBtu/hr Efficiency C. U-Factor: Sgl, U=1.05 240.00 ft2 a. Central Unit 30.0 SEER:14.00 SHGC: SHGC=0.28 b. Central Unit 45.5 SEER:14.00 d. U-Factor: other (see details) 18.18 ft2 c. Central Unit 41.0 SEER:14.00 13. Heating systems kBtu/hr Efficiency SHGC: other (see details) a. Electric Heat Pump 29.6 HSPF:8.20 Area Weighted Average Overhang Depth: 7.566 ft. b. Electric Heat Pump 45.0 HSPF:8.20 Area Weighted Average SHGC: I 0.301 c. Electric Heat Pump 38.5 HSPF:8.20 8. Floor Types Insulation Area 14. Hot water systems Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 3300.00 ft 2 a. Electric EF: 0.92 b. N/A R= ft2 c. N/A R= � ft2 b. Conservation features None 15. Credits Pstat I certify that this home has complied with the; Florida Energy Efficiency Code for Building Construction through the above energy savirig features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: _ Date Address of New Home: S PgA,ice Lj-, City/FL Zip:1?bek c� �oD f *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain'ia Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web 'site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 9/15/2015 1:55 PM EnergyGauge® USA - FlaRes2014 -Section R405.4.1 Compliant S wILE 0 Pa c' of 1 Stan Pac RB Wentworth Model HVAC Load Calculations for Standard Pacific Homes Prepared By: Greg Bolinsky Engineered Air LLC 2520 N Andrews Ave Ext Pompano Beach, FL 33064 954 974-7277 Tuesday, May 06, 2014 ILRhvac is an ACCA approved Manual J and Manual D computer program. � Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Project Title: Designed By: Project Date: Client Name: Company Name: Company Representative: Company Address: Company City: Company Phone: Company Fax: Company Comment: Greg Bolinsky Thursday, May 1, 2014 Standard Pacific Homes Engineered Air LLC Greg Bolinsky 2520 N Andrews Ave Ext Pompano Beach, FL 33064 954 974-7277 954 973-1883 ' Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 42 39.4 n/a n/a 70 n/a Summer: 90 ' 78 59% 50% 75 61 Total Building Supply CFM: 3,876 CFM Per Square ft.: 0.657 Square ft. of Room Area: 5,903 Square ft. Per Ton: 690 Volume (ft') of Cond. Space: 59,497 Bu`I v LoadsT1, .�n Total Heating Required Including Ventilation Air: 70,308 Btuh 70.308 MBH Total Sensible Gain: 85,191 Btuh 83 % Total Latent Gain: 17,419 Btuh 17 % Total Cooling Required Including Ventilation Air: 102,609 Btuh 8.55 Tons (Based On Sensible + Latent) Rhvac is an ACCA approved Manual J an'd Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\Stan Pac RB Wentworth Model.rh9 Tuesday, May 06, 2014, 10:04 AM C Lo-E French Door: Glazing-Low-E French Door, u-value 96 2,068 0 2,034 2,034 0.77, SHGC 0.22 Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value 296.1 3,315 0 7,351 7,351 0.4, SHGC 0.31 Lo-E operable: Glazing-Low-E Operable'Glass, u-value 624.6 10,507 0 15,159 15,159 0.6, SHGC 0.31 Lo-E Fixed: Glazing-Lo-E Insulated Tinted Impact Fixed 56 628 0 702 702 Glass, u-value 0.4, SHGC 0.31 Lo-E French Door: Glazing-Low-E French Door, u-value 96 2,068 0 2,000 2,000 0.77, SHGC 0.22 Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value 74 830 0 928 928 0.4, SHGC 0.31 Lo-E French: Glazing-Lo-E Insulated Tinted Impact 288 5,640 0 5,608 5,608 French Door, u-value 0.7, SHGC 0.19 11 J: Door -Metal - Fiberglass Core 21.4 192 0 192 192 13A-4ocs: Wall -Block, board insulation only, R-4 board 4492.7 17,988 0 9,828 9,828 insulation, open core, siding finish 12B-Obw: Part -Frame, R-11 insulation in 2 x 4 stud 213.4 310 0 310 310 cavity, no board insulation, brick finish, wood studs 13A-4ocs: Part -Block, board insulation only, R-4 board 160.1 343 0 343 343 insulation, open core, siding finish 12B-Osw: Part -Frame, R-11 insulation in 2 x 4 stud 138.7 202 0 202 202 cavity, no board insulation, siding finish, wood studs 16B-38: Roof/Ceiling-Under Attic with Insulation on Attic 3300 2,402 0 4,290 4,290 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-38 insulation 22A-pl: Floor -Slab on grade, No edge insulation, no 356 9,859 0 0 0 insulation below floor, any floor cover; passive, light soil Subtotals for structure: 56,352 0 48,947 48,947 People: 10 3,000 2,800 5,800 Equipment: 7,500 10,600 18,100 Lighting: 835 2,847 2,847 Ductwork: 6,328 1,568 7,667 9,235 Infiltration: Winter CFM: 248, Summer CFM: 129 7,628 5,351 2,124 7,475 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: 0 0 10,205 10,205 Total Building Load Totals: 70,308 17,419 85,191 102,609 `Check FjgUres�� Total Building Supply CFM: 3,876 CFM Per Square ft.: 0.657 Square ft. of Room Area: 5,903 Square ft. Per Ton: 690 Volume (ft3) of Cond. Space: 59,497 Total Heating Required Including Ventilation Air: 70,308 Btuh 70.308 MBH Total Sensible Gain: 85,191 Btuh 83 % Total Latent Gain: 17,419 Btuh 17 % Total Cooling Required Including Ventilation Air: 102,609 Btuh 8.55 Tons (Based On Sensible + Latent) N'o�es s Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\Stan Pac RB Wentworth Model.rh9 Tuesday, May 06, 2014, 10:04 AM System 1 Room Load Summary ---cone .i--- 1 AC 1 - Club 1,465 21,066 274 9-6 536 20,822 3,906 947 947 Room, Living Room & Bedroom 5 Duct Latent 386 System 1 total 1,465 21,066 274 20,822 4,292 947 947 System 1 Main Trunk Size: 12x14 in. Velocity: 812 ft./min Loss per 100 ft.: 0.106 in.wg Net Required: 2.09 83% / 17% 20,822 4,292 25,114 Actual: 2.40 75% / 25% 21,600 7,200 28,800 VE, ofant�©ata, ' Heating System Coolinq System Type: Air Source Heat Pump Air Source Heat Pump Model: 25HBC530A**30 25HBC530A**30 Indoor Model: FX4DN(B,F)031L Brand: CARRIER AIR CONDITIONING CARRIER AIR CONDITIONING Description: Air Source Heat Pump Air Source Heat Pump Efficiency: 8.5 HSPF 15.2 SEER Sound: 0 0 Capacity: 28,200 Btuh 28,800 Btuh Sensible Capacity: n/a 21,600 Btuh Latent Capacity: n/a 7,200 Btuh AHRI Reference No.: n/a 7017565 This system's equipment was selected in,accordance with ACCA Manual S. Manual S equipment sizing data: SODB:,90F, SOWB: 78F, WODB: 42F, SIDB: 75F, SIRH: 50%, WIDB: 70F, Sen. gain: 20,822 Btuh, Lat. gain: 4,292 Btuh, Sen. loss: 21,066 Btuh, Entering clg. coil DB: 75F, Entering clg. coil WB: 62.5F, Entering htg. coil DB: 70F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req. clg. airflow: 947 CFM, Req. htg. airflow: 274 CFM C:\ ...\Stan Pac RB Wentworth Model.rh9 Tuesday, May 06, 2014, 10:04 AM System 2Room Load Summary ---cone i--- 2 AC 2 - Family 1,835 28,063 365 15-6 544 35,224 5,611 1,603 1,603 Room, Kitchen, Dinina & Fover Duct Latent 555 System 2 total 1,835 28,063 365 35,224 6,166 1,603 1,603 System 2 Main Trunk Size: 18x18 in. Velocity: 712 ft./min Loss per 100 ft.: 0.054 in.wg Coolant S�rst2m Su , ma Net Required: Actual: Type: Model: Indoor Model: Brand: Description: Efficiency: Sound: Capacity: Sensible Capacity: Latent Capacity: AHRI Reference No.: 3.45 85% / 15% 35,224 3.96 75% / 25% 35,625 Heating System Air Source Heat Pump 25HBC548A**30 CARRIER AIR CONDITIONING Air Source Heat Pump 8.5 HSPF 0 45,500 Btuh n/a n/a n/a 6,166 11,875 Air Source Heat Pump 25HBC548A**30 FX4DN(B, F)049L CARRIER AIR CONDITIONING Air Source Heat Pump 15 SEER 0 47,500 Btuh 35,625 Btuh 11,875 Btuh 6936854 41,390 47,500 This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODB:i90F, SOWB: 78F, WODB: 42F, SIDB: 75F, SIRH: 50%, WIDB: 70F, Sen. gain: 35,224 Btuh, Lat. gain: 6,166 Btuh, Sen. foss: 28,063 Btuh, Entering clg. coil DB: 75F, Entering clg. coil WB: 62.517, Entering htg. coil DB: 70F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req. clg. airflow: 1603 CFM, Req. htg. airflow: 365 CFM C:\ ...\Stan Pac RB Wentworth Model.rh9 Tuesday, May 06, 2014, 10:04 AM CA ...\Stan Pac RB Wentworth Model.rh9 Tuesday, May 06, 2014, 10:04 AM