HomeMy WebLinkAboutSewage Final Approvalr0qslz). STATE OF FLORIDA ±� DEPARTMENT OF HEALTH 'ONSITE 'SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION.INSPECTION AND FINAL APPROVAL APPLICANT.. - Standafd Pacific FL: GP Inc ACENTx The: Milcor Group, Inc. PROPERTY ADDRESS`: 3108 NW'Radcliffe Way Palm City, FL 34990 LOT: 21 BLOCK: 1� ICATION #:AP'1.214942' PERMIT #:56-SF 1645912, DOCUMENT # : FI ,,11:3832 DATE PAID:12/03/2015 FEE PAID, 00:00 RECEIPT #.:56-PID-2855397 SUBDIVISION: Riverbend ID#: 4425-703-0026-000-3 CBECKEDfIX3 ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED,. TANK INSTALLATION - SETBACKS ] [oi] TANK SIZE [1] 1050.00 [21 483.00 [ ] [27] SURFACE WATER 95 _ _ FT ] [02] TANK.MATERIAL. Concrete [ ] [28] DITCHES 20 FT ] [03] OUTLET DEVICE ( ] [291 PRIIVATE WELLS FT ]; 1041 MULTI -CHAMBERED [ Y N ] [ .] [30] PUBLIC WELLS ] [0$] OUTLET FILTER Polylok PL-68 [ ] [311 IRRIGATION WELLS FT ] [0.6] LEGEND 1. 28-015-08SC3 2. 70-143-54SC4 [ ] 1321 POTABLE WATER 57 FT ] {07] WATERTIGHT [ ] [33,1 BUILDING FOUNDATIONS 5'' FT ] [093 LEVEL [ ] [341 PROPERTY LINES 5 FT ]' [09] DEPTH TO LID [ ] [35] OTHER FT DRAINFIELD INSTALLATION FILLED /!MOUND SYSTEM ] [10] AREA [1] 803.72 [2] SQFT [ ] [36] DRAINFIELD COVER ]; [11] DISTRIBUTION BOX HEADER X [ ] [371 SHOULDERS ]' (-12] NUMBER OF DRAINLINES 1. 5.00 2. [ ] [381 SLOPES ] [13] DRAINLINE SEPARATION [ ] [391 STABILIZATION 05/15/2017 r [14] DRAINLINE SLOPE ] [151 DEPTH OF 'COVER ADDITIONAL INFORMATION ] 1163 ELEVATION ( ABOVE / BELOW ]BM 24.00 [ ] [401 UNOBSTRUCTED AREA ]' [17]. SYSTEM LOCATION [ ] [41] STORMWATER RUNOFF [3.8]; 'DOSING' PUMPS 1.00 [ ] [421 ALARM [ ] [191 AGGREGATE SIZE [ ] [43] MAINTENANCE AGREEMENT l j [201, [21]. AGGREGATE EXCESSIVE FINES AGGREGATE DEPTH [ [ ] ] [441 [451 BUILDING AREA LOCATION CONFORMS WITH SITE PLAN (. ] [' ] FILL / EXCAVATION MATERIAL [22] FILL AMOUNT ([Z3] FILL TEXTURE l6 L [ ti�11[ ] ] ] I467 [47] [48] FINAL SITE GRADING CONTRACTOR Brian 'Dayis',(-Bdan Dayis.Sept_, oTFIER INFILTRATOR Quick4 Plus; E036 LP [ ] [241 May EXCAVATION DEPTH ABANDONMENT [25], pr�<1vED AREA,REPLACED P` G [ l [49] TANK PUMPED [26] REPLACEMENT MATERIAL [ ] [501 TANK CRUSHED & FILLED Comments: Comments are on page 2. CONSTRUCTION [ APPROVED / DISAPPROVED 1: Fnvirnnmental FINAL,, SYSTEM [ APPROVED / DISAPPROVED ]: -L--- St. Lucie CHD DAM: 12/12/2016 J Ingram (ENVIRONMENTAL HEALTH) St. Lucie CHD IONMENTAL HEALTH) (Explanation of violations on following page) I DH 4016,, 08/09 (Obsoletes all previous- editions which may not be used) Incozpoated: 64E-6.003, FAC EH Database v 1.0.1 AP1214942 EID1645912 DATE: 05/.15/2017' Page 2 of 3 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSI'VE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment J, IcATxox #:AP12,14942 PEMUT #:56-SF-1645912 DOCMMNT #:F1111; 832 DATE PAID :12/03/2015 FEE PAZD A00.0,0 DT.rWTDT 0..56-PID-28553.9.7 The system is sized for 5 bedrooms with, a maximum occupancy of 10 persons (2 per bedroom); for a total estimated flow of 640 gpd.,1650<gal+483_gal ST in series. liberty 1/3 HP pump. 540gal DT 70-143-54SC4. 4x14+1x1511 ng=71 chambers. No violations; system,bk to cover. Contractor notified onsite. Needs final inspection for mound system and alarm check. Final system approved. Buildingr department and contractors emailed final approval. _ DR 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated:. 64E-6-..003, PAC EH Databaso v 1.0.1 AP1214942 EID1fi45912 Page. '2 of '3'