all FL# C20203
Application Type
Code Version Application Status
Comments
Archived
Product Manufacturer Extreme Metal Fabricators, LLC
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
flvalidation@yahoo.com
Authorized Signature Richard McKuhen
flvalidation@yahoo.com
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
rchard@emfab.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the David Eng
Evaluation Report
Florida License PE-81377
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 04/ 2—/2024
Validated By James R Wally, PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL17022 R8 COI 26ga VMAX plywo pdf
Referenced Standard and Year(of Standard) Standard Year
TAS 100 1995
TAS 125 2003
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
https://www.floridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR°/`2bd%2buNxXG%2bnlRhGTtoBWMIaQ%3d... 1/3
1/6/2021 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 10/05/2020
Date Validated 10/12/2020
Date Pending FBC Approval 10/25/2020
Date Approved 12/15/2020
Date Revised 12/16/2020
Summary of Products
FL�# C Model,Number or Name ;Description
j 17022.1 j 01: 26ga VMax on Plywood f 26ga (min)VMax 5V panel with 24"coverage on 15/32" (min)
If plywood or 3/4"(min)thick wood plank.
i Limits of Use Installation Instructions
j Approved for use in HVHZ: No FL17022 R8 II 26ga VMAX plywood.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A i Created by Independent Third Party:Yes
Design Pressure: +N/A/-228 Evaluation Reports
Other: Refer to evaluation report. FL17022 R8 AE 26ga VMAX plywood.pdf
j Created by Independent Third Party:Yes
17022.2 02: 032 Aluminum VMax on Plywood I Nominally 0.032"aluminum(or thicker)VMax 5V panel with
121"coverage on 15/32" (min) plywood or 3/4" (min)thick
I wood plank.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R8 II 032 VMAX 21in plywood.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng,PE 81377
i Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-168.5 Evaluation Reports
Other: Refer to evaluation report. FL17022 R8 AE 032 VMAX 21in plywood.pdf
LCreated by Independent Third Party: Yes i
17022.3 03: 26ga VMax on Plywood j 26ga(min)VMax 5V panel with 24"coverage on 15/32" (min)
plywood or 3/4"(min)thick wood plank. Option for fasteners in
I the flats and in the ribs.
Limits of Use j Installation Instructions
Approved for use in HVHZ: No FL17022 R8 II 26ga VMAX plywood flats.pdf
Approved for use outside HVHZ:Yes I Verified By: David Eng,PE 81377
Impact Resistant: N/A Created by Independent Third Party:Yes
Design Pressure: +N/A/-114.25 Evaluation Reports
Other: Refer to evaluation report. FL17022 R8 AE 26ga VMAX plywood flats.pdf
R Created by Independent Third Party:Yes II
17022.4 04: 26ga CorMax on Plywood 26ga (min)CorMax corrugated panel with 29.5"coverage on
15/32" (min) plywood or 3/4" (min)thick wood plank.
Limits of Use i Installation Instructions
Approved for use in HVHZ:Yes I FL17022 R8 II 26ga CorMax Plywood HVHZ.pdf
Approved for use outside HVHZ:Yes j Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party:Yes
I Design Pressure: +N/A/-161 Evaluation Reports
i Other: Refer to evaluation report. FL17022 R8 AE 26ga CorMax Plywood HVHZ.pdf
Created by Independent Third Party:Yes
17022.5 05: 26ga CorMax on Battens 26ga (min)CorMax corrugated panel with 29.5"coverage on
2x4(min) battens.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R8 II 26ga CorMax Battens.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-161 Evaluation Reports
Other: Refer to evaluation report. _ } FL17022 R8 AE 26ga CorMax Battens.pdf
i Created by Independent Third Party:Yes
0
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395,*Pursuant to Section 455.275(1),
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkU EoR%2bd%2buNxXG%2bnlRhGTtoBWM 1 aQ%3d... 2/3
p
EXTREMEMETAL
FABRICATORS
SKILLED C•RAFTCRS OFMETAL ROOFING SYSTEMS
26ga (min ) VMAX over 15/32" ( min ) plywood ,
Extreme Metal Fabricators
2120 SW Poma Dr I Palm City FL 34990
Product Description (
5V Crimp style exposed fastener panel with 24" max coverage and nominal
rib height of 3/8".
Product Material
26ga (min) steel
Corrosion resistant per FBC 1507.4.3 where required
Fastener
9 or #10 x 1.5" fastener with sealing washer
Compliant with FBC 1506.6 where required.
Substrate/Deck
15/32" (min) plywood or
3/4" (min) thick wood plank (min S.G. of 0.42)
Evaluated by:
David Eng, PE
Timberlake Cove, LLC
3324 W Univ Ave #206 1 Gainesville FL
FL PE 81377 1 FL CA 33344
www.TimberLakeCove.com
Q,• �.10ENS�• .�
David E Eng NO. 81377
..h - 2020.10.06 —_
00:08:33+01'00v
''0 STATE OF
`ONIAL��
digitallyThis item has been . .
and seated .
date indicated . copies
considereddocument are not signed
and seated and the signature must be
MAX
verified on any electroniccopies
r
II �■ ■ I � ■I ' � I I I . , � I
4 YAw
■
�I
mm
I
i
i
ti
■
ENGINEERING LOAD TABLES
Instructions:
Select the appropriate load table that applies to the
structure in question. X
�
Determine the design wind speed for the project a 2 2 13
location. 1 2
Use the attachment method indicated for that 2
P
winds eed within each roof zone. \1\ 2 2 3 a
2 1 2 2
NOTE: ASCE 7-16 and FBC 2020 adopt a 7-zone concept. //"/ _ }
For the load tables below, the worst case was taken �//Z 1/ 1 1 2
for each zone and reported using the standard zones 2/ —
a 3 2 2 3 a
Zone 1 includes zones 1 and 1} I
Zone 2 includes zones 2e, 2r, and 2n aL HIP ROOF GABLE ROOF -aL
Zone 3 includes zones 3e and 3r ---t>
Combining these zones creates a clear, simple fl:101;OF LEAST HOIZONTAL DIMENSION OR 0 dh,WHICHEVER IS SMALLER BUT NOT
LESS THAN EITHER A°e OF LEAST HORIZONTAL DIMENSION OR 3FT(OSM).
scheme, at the expense of some design efficiency. OR AS DETERMINED BY DESIGN OR OTHER APPLICABLE CODE.
Contact the manufacturer for further information, ROOF ZONES FOR GENERIC BUILDING
or consult a licensed design professional.
METHOD A: METHOD B: METHOD C: METHOD D:
#9 AT 16"O.C. #10 AT 16"O.C. #10 AT 8"O.C. #10 AT 6"O.C.
Ir —12" (NOM) 12"(NOM)— NR: NOT RATED. CONSULT DESIGN
PROFESSIONAL AS NEEDED
Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria:
Are located in Exposure B area Are located in B,C,or D exposure area
Have either a flat roof,or gable/hip roof with max slope of 12:12 Have either a flat roof,or gable/hip roof with max slope of 12:12
Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less
FL17022.01: 26 a 5V Crimp on 15/32" plywood FL17022.01: 26 a 5V Crim on 15/32" 121=ood
Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200
Zone 1: A A A A A A A A A A A Zone 1: A A A A A A A C D D D
Zone 2: A A A A A A A A C D D Zone 2: A A A A C D D D D D D
Zone 3: A A A A A A B C D D D Zone 3: A A A C D D D D D D
Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria:
Are located in Exposure B area Are located in B,C,or D exposure area
Have either a flat roof less than 70,hip roof with Have either a flat roof less than 70,hip roof with
max slope of 12:12,or gable roof with slope between 4.4:12&12:12 max slope of 12:12,or gable roof with slope between 4.4:12&12:12
Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less
FL17022.01: 26 a 5V Crimp on 15/32" plMood FL17022.01: 26 a 5V Crimp on 15/32" 121=ood
Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200
Zone 1: A A A A A A A A A A A Zone 1: A A A A A A A B C D D
Zone 2: A A A A A A A A A B C Zone 2: A A A A A B D D D D D
Zone 3: A A A A A A A B D D D Zone 3: A A A B D D D D D D D
TORS. s