Loading...
HomeMy WebLinkAboutEngery Calcs FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: ALEXANDER&MiLLAN Builder Name: Street: LOT 19 NETTLES ISLAND Permit Office: City,State,Zip: JENSEN BEACH,FL, Permit Number: Owner: Jurisdiction: Design Location: FL,Fort Pierce 1. New construction or existing New(From Plans) 9. Wall Types(1258.5 sgft.) Insulation Area a.Concrete Block-Ext Insul,Exterior R=4.2 1258.50 ft2 2. Single family or multiple family Single-family b.N/A R= fV 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 1 d.N/A R= ft2 10.Ceiling Types (916.0 sqft.) Insulation Area 5. Is this a worst case? No a.Roof Deck(Unvented) R=20.0 916.00 ft2 6. Conditioned floor area above grade(ft2) 916 b.N/A R= ft2 Conditioned Floor area below grade(ft c.N/A R= ft22) 0 11.Ducts R ft2 7. Windows(142.2 sgft.) Description Area a.Sup:Attic,Ret:Attic,AH:LAUNDRY 6 195 a. U-Factor: Sgl,U=0.45 142.17 ft2 SHGC: SHGC=0.25 b. U-Factor N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 18.0 SEER.16.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Strip Heat 17.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.202 ft. Area Weighted Average SHGC: 0.250 14.Hot water systems 8. Floor Types (915.5 sgft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge insulation R=0.0 915.50 ft2 b. Conservation features EF•.G.900 b.N/A R= ft2 None c.N/A R= ft2 15.Credits CF Glass/Floor Area: 0.155 Total Proposed Modified Loads: 32.18 PASS Total Baseline Loads: 32.50 I hereby certify that the plans and specifications covered by Review of the plans and [NE 5Tg1� this calculation are in compliance with the Florida Energy specifications covered by this �` �.r� _ =�, p Code. calculation indicates compliances' vt with the Florida Energy Code. .4 p PREPARED BY: _ Before construction is completed a b� DATE: ��(�_ this building will be inspected for Q�R a ,-N� compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. c with the Florida Energy Code. OWNER/AGENT:_�_-},_ BUILDING OFFICIAL: DATE: _- /L' �o DATE: -_ Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 1/18/2016 12:16 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Pegs 1 of 5 FORM R405-2014 PROJECT Title: ALEXANDER&MILLAN Bedrooms: 1 Address Type: Street Address Building Type: User Conditioned Area: 916 Lot# Owner: Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: LOT 19 NETTLES ISLA Permit Office: Cross Ventilation: No County: ST.LUCIE COUNTY Jurisdiction: Whole House Fan: No City,State,Zip: JENSEN BEACH, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL_ST_LUCIE_GO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Entire House 916 8240 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 KTICHEN 154 1386 Yes 0 1 Yes Yes Yes 2 BATH 55 495 No 0 1 Yes Yes Yes 3 CLSET 35 315 No 0 1 Yes Yes Yes 4 BEDROOM 1 163 1467 No 2 1 1 Yes Yes Yes 5 LAUNDRY 49 441 No 0 1 Yes Yes Yes 6 BATH 2 49 441 No 0 1 Yes Yes Yes 7 FOYER 114 1026 No 0 1 Yes Yes Yes 8 LIVING 297 2669 No 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio KTICHEN 21 ft 0 154 ft2 _-__ 0 1 0 2 Slab-On-Grade Edge Insulatio BATH 5ft 0 55 ft2 ____ 0 1 0 3 Slab-On-Grade Edge Insulatio CLSET 5ft 0 35 ft2 0 1 0 4 Slab-On-Grade Edge Insulatio BEDROOM 1 28 ft 0 163 ft2 0 1 0 5 Slab-On-Grade Edge Insulatio LAUNDRY 7ft 0 49 ft' 0 1 0 6 Slab-On-Grade Edge Insulatio BATH 2 7ft 0 49 fly ____ 0 1 0 7 Slab-On-Grade Edge Insulatio FOYER 18 ft 0 114 ft2 __-_ 0 1 0 8 Slab-On-Grade Edge Insulatio LIVING 48.8 ft 0 296.5 ft' _--_ 0 1 0 1/18/2016 12:16 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 992 ftz 190 ftz Light 0.6 No 0.9 No 20 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 916 ftz N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic(Unvented) KTICHEN 20 154 ftz 0.1 Wood 2 Under Attic(Unvented) BATH 20 55 ftz 0.1 Wood 3 Under Attic(Unvented) CLSET 20 35 ftz 0.1 Wood 4 Under Attic(Unvented) BEDROOM 1 20 163 ftz 0.1 Wood 5 Under Attic(Unvented) LAUNDRY 20 49 ftz 0.1 Wood 6 Under Attic(Unvented) BATH 2 20 49 ftz 0.1 Wood 7 Under Attic(Unvented) FOYER 20 114 ftz 0.1 Wood 8 Under Attic(Unvented) LIVING 20 297 ftz 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below #__Omt- To Wall Type- -- Space .R-A1alue---Ft--_In -Et-In Arpa R-Vahi#- Fraction Absor. ° _ 1 NE Exterior Concrete Block-Ext InsulKTICHEN 4.2 7 0 9 0 63.0 ft' 0 0 0.8 0 _ 2 NW Exterior Concrete Block-Ext InsuIKTICHEN 4.2 14 0 9 0 126.0 ftz 0 0 0.8 0 _ 3 NW Exterior Concrete Block-Ext Insul BATH 4.2 5 0 9 0 45.0 ftz 0 0 0.8 0 4 NW Exterior Concrete Block-Ext Insul CLSET 4.2 5 0 9 0 45.0 ftz 0 0 0.8 0 5 SE Exterior Concrete Block-Ext InsBEDROOM 1 4.2 4 0 9 0 36.0 ft' 0 0 0.8 0 _ 6 SW Exterior Concrete Block-Ext InsEIIEDROOM 1 4.2 11 0 9 0 99.0 ftz 0 0 0.8 0 7 NW Exterior Concrete Block-Ext InsEDROOM 1 4.2 13 0 9 0 117.0 ftz 0 0 0.8 0 8 SE Exterior Concrete Block-Ext InsuLAUNDRY 4.2 7 0 9 0 63.0 ftz 0 0 0.8 0 9 SE Exterior Concrete Block-Ext Insul BATH 2 4.2 7 0 9 0 63.0 ftz 0 0 0.8 0 10 SE Exterior Concrete Block-Ext Insul FOYER 4.2 6 0 9 0 54.0 ftz 0 0 0.8 0 11 SW Exterior Concrete Block-Ext Insul FOYER 4.2 11 0 9 0 99.0 ftz 0 0 0.8 0 12 NW Exterior Concrete Block-Ext Insul FOYER 4.2 1 0 9 0 9.0 ftz 0 0 0.8 0 13 NE Exterior Concrete Block-Ext Insul LIVING 4.2 15 10 9 0 142.5 ftz 0 0 0.8 0 14 SE Exterior Concrete Block-Ext Insul LIVING 4.2 26 0 9 0 234.0 ftz 0 0 0.8 0 15 NW Exterior Concrete Block-Ext Insul LIVING 4.2 7 0 9 0 63.0 ftz 0 0 0.8 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SW Wood FOYER None .39 3 7 21 ftz 1/18/2016 12:16 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 WINDOWS Orientation shown is the entered,Proposed orientation. / Wall Overhang v # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 NE 1 None Low-E Single Yes 0.45 0.25 34.2 ft' 6 ft 0 in 1 ft 5 in None None 2 NW 2 None Low-E Single Yes 0.45 0.25 18.0 ftz 1 ft 0 in 1 ft 5 in None None 3 NW 3 None Low-E Single Yes 0.45 0.25 6.0 ftz 1 ft 0 in 1 ft 5 in None None 4 SW 6 None Low-E Single Yes 0.45 0.25 24.0 ftz 1 ft 0 in 1 ft 5 in None None 5 NW 7 None Low-E Single Yes 0.45 0.25 20.0 ft' 1 ft 0 in 1 ft 5 in None None 6 SW 11 None Low-E Single Yes 0.45 0.25 10.0 ftz 1 ft 0 in 1 ft 5 in None None 7 NE 13 None Low-E Single Yes 0.45 0.25 30.0 ftz 1 ft 0 in 1 ft 5 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000286 686.7 37.7 70.89 .2086 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP:1 17 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity _ Air Flow SHR _Block Ducts 1 Central Unit Split SEER:16 18 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Attic 0.9 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftz DUCTS --Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 195 ft2 Attic 40 ftz Default Leakage LAUNDRY (Default) (Default) 1 1 1/18/2016 12:16 PM EnergyGauge D USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 TEMPERATURES Programable Thermostat: N Ceiling Fans: Coolin Jan Feb Mar Apr May ri Jun ri Jul rl Aug ri Se Oct Nov Dec Heating HJan HFeb Mar r I May Jun Jul AuSep Oct X Nov Dec Jan Feb X Mar r IMa Jun Jul Aug Se (Xl Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM M 80 80 80 80 7 78 8 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 1/18/2016 12:16 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: ALEXANDER&MILLAN Builder Name: Street: LOT 19 NETTLES ISLAND Permit Office: City,State,Zip: JENSEN BEACH,FL, Permit Number: Owner: Jurisdiction: Design Location: FL,Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Comers and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. _ Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/doorjambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shalt be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 111 M016 12:16 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. LOT 19 NETTLES ISLAND, JENSEN BEACH, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.2 1258.50 ft' b.N/A R= ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 1 d.N/A R= ft' 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Roof Deck(Unvented) R=20.0 916.00 It' S. Conditioned floor area(IF) 916 b.N/A R= fe 7. Windows— Description Area c.N/A R= ft' a. U-Factor: Sgt,U=0A5 142.17 ft' 11.Ducts R ft2 SHGC: SHGC=025 a.Sup:Attic,Ret:Attic,AH:LAUNDRY 6 195 b. U-Factor: N/A ft' SHGC: 12.Cooling systems kStu/hr Efficiency c. U-Factor: N/A ft' a.Central Unit 18.0 SEER:16.00 SHGC: d. U-Factor: N/A fF 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Strip Heat 17.0 COPA.00 Area Weighted Average Overhang Depth: 2.202 ft. Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14.Hot water systems a.Electric Cap:40 F:ons 0.9 a.Slab-On-Grade Edge Insulation R=0.0 915.50 ft' EF:0.9 b.N/A R= ft' c.WA R= ft2 b. conservation features None 15.Credits CF I certify that this home has complied with the Florida Energy Efficiency Code for Building " Construction through the above energy saving features which will be installed (or exceeded) Oko FTHF sTgr� in this home before final inspection. Otherwise, a new EPL Display Card will be completed a3`9`� >> '=' 106 t;o � based on installed Code compliant features. �/ x � o Builder Signature: /G/ `mil C Date: Address of New Home: `�? /Vr,rlfSC jo f5 City/FL Zip: y.COD SRJ��r *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. vl arzol a 1 z:16 f M EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 Project Summary Date: Jan 18,2016 + - wrightsoft° Entire House By: QUICK CALCS, INC. 317 ST LUCIE LN., FT PIERCE, FL34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM Project Information For. ALEXANDER & MILLAN LOT 19 NETTLES ISLAND, JENSEN BEACH, FL Notes: D• • n Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 14422 Btuh Structure 10862 Btuh Ducts 1930 Btuh Ducts 1338 Btuh Central vent (48 cfm) 1490 Btuh Central vent(48 cfm) 798 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 17842 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 12348 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2119 Btuh Ducts 1154 Btuh Heating Cooling Central vent (48 cfm) 2022 Btuh Area(ftz) 916 916 Equipment latent load 5296 Btuh Volume V) 8240 8240 Air changes/hour 0.45 0.23 Equipment total load 17643 Btuh Equiv.AVF (cfm) 62 32 Req. total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Rheem Trade Trade RHEEM; RUUD Model Cond RA1618AJ1 AHRI ref Coil RH1T2417STAN AHRI ref 7940565 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 5.1 kW Sensible cooling 12600 Btuh Heating output 17448 Btuh Latent cooling 5400 Btuh Temperature rise 26 OF Total cooling 18000 Btuh Actual air flow 600 cfm Actual air flow 600 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.71 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. WC19f1tL50ft' RightSuite®Universal2015 15.0.19 RSU 2016-Jan-18 13:26:0408101 Page 1 MCA ...rs\Quick CalcslD cuments\ALEXANDER&MILLAN.rup Calc=MJ8 Front Door faces: N }+- wrightsoft, Right-A)Worksheet Job: Entire House Date: Jan 18,2016 By: QUICK CALCS, INC. 317ST.LUCIE LN., FT. PIERCE, FL34946 Phone:772-466-6799 Fax 772466-6796 Email:OUICKCALCS@AOL.COM 1 Room name Entire House KTICHEN 2 Exposed wall 139.8 ft 21.0 ft 3 Room height 9.0 ft d 9.0 ft heat/cool 4 Room dimensions 11.0 x 14.0 ft 5 Room area 915.5 ft2 154.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ftl Load number (Btuh/W°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) lHeatCool Gross N/P/S Heat Cod Gross N/P/S Heat Cool 6 13AAocs 0.143 ne 2.55 205 141 566 360 63 29 116 74 2 glazing,clr low-e 0.650 ne 26.88 30 0 546 806 0 0 0 0 2 glazing,clr low-e 0.650 ne 26.88 34 0 619 914 34 0 619 914 w 13A-4ocs 0.143 se 2.55 450 450 1802 1145 0 0 0 0 11 Vh13A-flocs 0.143 sw 2.55 198 143 573 364 0 0 0 0 2 glazing,clr low-e 0.650 sw 18.20 25.57 24 3 437 614 0 0 0 0 2 glazing,clr low-e 0.650 sw 18.20 25.87 10 1 182 259 0 0 0 0 11 DO 0.390 sw 10.92 11.31 21 21 229 238 0 0 0 0 13A-4ocs 0.143 nw 4.00 2.55 405 361 1445 919 126 108 432 275 2 glazing,clr low-e 0.650 nw 18.20 26.88 6 0 109 161 0 0 0 0 2 glazing,clr low-e 0.650 nw 18.20 26.88 18 0 328 484 18 0 328 484 2 coazing,clr low-e 0.650 nw 18.20 26.88 20 0 364 538 0 0 0 0 C 16X19-0md 0.408 - 1.59 1.49 916 916 1452 1361 154 154 244 229 F 22A-tpl 0.989 - 27.69 0.00 916 140 3870 0 154 21 582 0 6 c)AE D exwrsion 260 -34 Envelope lossigain 12521 8421 2321 1941 12 a) Infiltration 1902 521 286 78 b) Room ventilation 0 0 01 0 13 Internal gains: Occupants @ 230 4 920 0 0 Appliances/other 1000 1000 Subtotal(lines 6 to 13) 14422 10862 2606 3019 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 14422 10862 2606 3019 15 Duct loads 13% 12% 1930 1338 13% 12% 349 372 Total room load 16352 12199 2955 3391 Air reWred(cfm) 600 600 1 108 167 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� -11'- wrightsoft' R 2016Jan-1813:26:04 igMSulte®Universal 2015 15.0.19 RSU08101..rs\Quick Calcs\Documents\ALEXANDER 8 MILLAN.rup Cale=MA Front Door faces: N Page 1 + wrightsoft Right-J®Worksheet Job: Entire House Date: Jan 18,2016 By: QUICK CALCS, INC. 317 ST.LUGE LN., FT.PIERCE, FL34946 Phone:772-466-6799 Fax 772-1666796 Email:QUICKCALCS@AOL.COM 1 Room name BATH CLSET 2 Exposed wall 5.0 ft 5.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 11.0 x 5.0 ft 7.0 x 5.0 ft 5 Room area 55.0 ft' 35.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft2) Load number (Btuh/W°F) (Btuh/ft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13AAocs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 �-G 2 glazing,clr low-e 0.650 ne 18.20 26.88 0 0 0 0 0 0 0 0 �-G 2 glazing,clr low-e 0.650 no 18.20 26.88 0 0 0 0 0 0 0 0 W 13AAocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 11 yJ 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 0 0 0 0 III-�Gp 2 glazing,clr low-e 0.650 sw 18,20 25,57 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 sw 18.20 25.87 0 0 0 0 0 0 0 0 11 DO 0.390 sw 10.92 11.31 0 0 0 0 0 0 0 0 TE� 13AAocs 0.143 nw 4.00 2.55 45 39 156 99 45 45 180 115 2 glazing,clr low-e 0.650 rrw 18.20 26.88 6 0 109 161 0 0 0 0 2 glazing,clr low-e 0.650 nw 18.20 26.88 0 0 0 0 0 0 0 0 2 glazinq,clr low-e 0.650 rnv 18.20 26.88 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 - 1.59 1.49 55 55 87 82 35 35 55 52 F 22A-tpl 0.989 - 27.69 0.00 55 5 138 0 35 5 138 0 6 c)AE D e)cursion 38 -5 Envelope loss/gain 491 380 374 162 12 a) Infiltration 6B 19 68 19 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants® 230 0 0 0 0 AppliarrAWother 0 0 Subtotal(lines 6 to 13) 559 399 442 181 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistnbution 0 0 0 0 14 Subtotal 559 399 442 181 15 Duct loads 13% 12% 75 49 13% 12% 59 22 Total mom load 634 448 5501 203 Air required(cfm) 23 22 181 10 Calculations approved byACCA to meet all requirements of Manual J 8th Ed wrightsoft 2016-Jan-18 13.26:04 �� RightSuite®Universal 2015 15.0.19 RSU08101..rs\Quick Calcs\Documents\ALEXANDER 8 MILLAN.rup Calc=MJ8 Front Door faces: N Page 2 wrightsoft Right-J®Worksheet Job: Entire House Date: Jan 18,2016 By: QUICK CALCS, INC. 317ST LUCIE LN., FT. PIERCE, FL34946 Phone:772-466-6799 Fax 772466-6796 Email:QUICKCALCS@AOL.COM 1 Room name BEDROOM 1 LAUNDRY 2 Exposed wall 28.0 ft 7.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 163.0 ft 7.0 x 7.0 ft 5 Room area 163.0 ft2 49.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft?°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 no 4.00 2.55 0 0 0 0 0 0 0 0 �G 2 glazing,clr low-e 0.650 ne 18.20 26.88 0 0 0 0 0 0 0 0 �G 2 glazing,clr low-e 0.650 no 18.20 26.88 0 0 0 0 0 0 0 0 w 13Ar4ocs 0.143 se 4.00 2.55 36 36 144 92 63 63 252 160 11 1 MAocs 0.143 sw 4.00 2.55 99 75 300 191 0 0 0 0 2 glazing,clr low-e 0.650 sw 18.20 25.57 24 3 437 614 0 0 0 0 2 glazing,clr low-e 0.650 sw 18.20 25.87 0 0 0 0 0 0 0 0 11 DO 0.390 sw 10.92 11.31 0 0 0 0 0 0 0 0 1/1J 13A-4ocs 0.143 nw 4.00 2.55 117 97 388 247 0 0 0 0 2 glazing,clr low-e 0.650 rrva 18.20 26.88 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.650 rrvv 18.20 26.88 0 0 0 0 0 0 0 0 2(:lazinq,clr low-e 0.650 nw 18.20 26.88 20 0 364 538 0 0 0 0 C 16X19.0md 0.408 - 1.59 1.49 163 163 258 242 49 49 78 73 F 22A-tpI 0.989 - 27.69 0.00 163 28 775 0 49 7 194 0 6 c)AE D e)cursion 290 -7 Envelope loss/gain 2667 2213 524 227 12 a) Infiltration 381 104 95 26 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 2 460 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 3048 2777 619 253 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3048 2777 619 253 15 Duct loads 13% 12% 408 342 13% 12% 83 31 Total room load 3456 3120 702 284 Air required(cfm) 127 1531 1 1261 14 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsaft, RightSufte®Universal 2015 15.0.19 RSU08101 2016-Jan-18 13:226 04 ACCk ..rs\Quick Calcs\Documents\ALEXANDER 8 MILLAN.rup Calc=MJ8 Front Door faces: N Page 3 wrigntsoft Right-.1® Worksheet Job: Entire House Date: Jan 18,2016 By: QUICK CALCS, INC. 317 ST LUCIE LN., FT PIERCE, FL34946 Phone:772-466-6799 Fax 772466-6796 Email:QUICKCALCS@AOL.COM 1 Room name BATH 2 FOYER 2 Exposed wall 7.0 ft 18.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heaUcool 4 Room dimensions 7.0 x 7.0 ft 1.0 x 114.0 ft 5 Room area 49.0 ft' 114.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft� Load number (Btuh/ft''°F) (Btuh/ft�) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool G. N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.650 ne 18.20 26.88 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.650 no 18.20 26.88 0 0 0 0 0 0 0 0 w 13A-4ocs 0.143 se 4.00 2.55 63 63 252 160 54 54 216 137 11 Vh13AAocs 0.143 sw 4.00 2.55 0 0 0 0 99 68 272 173 2 glazing,clr low-e 0.650 sw 18.20 25.57 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0,650 sw 18.20 25.87 0 0 0 0 10 1 182 259 11 DO 0.390 sw 10.92 11.31 0 0 0 0 21 21 229 238 13AAocs 0.143 nw 4.00 2.55 0 0 0 0 9 9 36 23 2 glazing,cir low-e 0.650 nw 18.20 26.88 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.650 rm 18.20 26.88 0 0 0 0 0 0 0 0 2 glazinq,cir low-e 0.650 rm 18.20 26.88 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 - 1.59 1.49 49 49 78 73 114 114 181 189 F 22A-tpl 0.989 - 27.69 0.00 49 7 194 0 114 18 498 0 6 c)AE D excursion -7 58 Envelope loss/gain 524 227 16151 1057 12 a) Infiltration 95 26 245 67 b) Room ventilation 0 0 1 0 0 13 1ntemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 619 253 1860 1124 Less external bad 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 619 253 1860 1124 15 Duct loads 13% 12% 83 31 13% 12% 249 138 --T- --.. 1 Total room load 702 284 2109 1262 Air required(cfm) 26 14 T71 62 Calculations approved byACCA to meet all requirements of Manual J 8th Ed wrightsaft- RightSuite®Universal 2015 15.0.19 RSU08101 2016-Jan-18 13:26:04 ACCA rs\Quick Cabs\Documents\ALEXANDER&MILLAN.rup Calc=MJ8 Front Door faces: N Page 4 + wrightsort Right-J® Worksheet Job: Entire House Date: Jan 18,2016 By: QUICK CALCS, INC. 317 ST LUCIE LN, FT PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466-6796 Email.QUICKCALCS@AOL.COM 1 Room name LIVING 2 Exposed wall 48 8 ft 3 Room height 9.0 ft heat/cool 4 Room dimensions 1 0 x 296.5 ft 5 Room area 296.5 ft' Ty Construction U-value Or HTM Area (ft') Load Area Load number (BtuWft?°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W� 13A-4ocs 0.143 ne 4.00 2.55 142 112 450 286 2 glazing,clr low-e 0.650 ne 18.20 26.88 30 0 546 806 2 glazing,cir low-e 0.650 ne 18,20 26.88 0 0 0 0 W 13A-4ocs 0.143 se 4.00 2.55 234 234 937 596 11 N 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 2 glazing,cir low-e 0.650 sw 18.20 25.57 0 0 0 0 2 glazing,clr low-e 0,650 sw 18.20 25.87 0 0 0 0 11 DO 0.390 sw 10.92 11.31 0 0 0 0 1/p! 13A-4ocs 0,143 nw 4.00 2.55 63 63 252 160 �---G 2 glazing,clr low-e 0.650 nw 18.20 26,88 0 0 0 0 —G 2 glazing,clr low-e 0,650 nw 18.20 26,88 0 0 0 0 L—G 2 glazinq,clr low-e 0.650 nw 18,20 26.88 0 0 0 0 C 16X19-0md 0.408 1.59 1.49 297 297 470 441 F 22A-tpl 0.989 27,69 0.00 297 49 1350 0 6 c)AED excursion -74 Envelope loss/gain 4005 2215 12 a) Infiltration 664 182 b) Room ventilation 0 0 13 Intemal gains: Occupants @ 230 2 460 Appliances/other 0 Subtotal(lines 6 to 13) 4669 2857 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 4669 2857 15 Duct loads 13% 12% 625 352 Total room load 5294 3209 Air required(cfm) 194 158 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A wrightsoft 2016-Jan-1813:26:04 A GG A RightSuiteCa�Universal 2015 15 0.19 RSU08101 Page 5 ..rs\Quick Calcs\Documents\ALEXANDER 8 MILLAN.rup Ca lc=MJ8 Front Door faces. N