Loading...
HomeMy WebLinkAboutBlower Door TesttEE1°>d.O.IJIL'18Ni & Ct�ICIn'a'TfTli Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition jurisdiction: Permit #: Job information IL Builder: K Hovnanian Community: LeLot: �►. Unit: Address:, (�3 1" City: ��r ��c rc State: FL Zip: House S.F: Avg. Ceiling Height. Total Volume: Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method OPRESCRIPTIVE METHOD The building or dwelling unit shall be tested and verified as having an air leakage rate or not exceeding 7 air change 'per hour at a pressure of 0'.2-lnch w.g. (50 pascals) in climate zones I and 2. r PeERFORMANCE OR ERI METHOD T The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50) value, as shown on FORM 14405-2017 (performance) or R40&2017 (FRI), section labeled as infiltration, sub" section ACH: ACH(50) specified on Form R405S 20174nergy Calc (Performance) or R406,TV, 017 (ERI): ; Pressure & Flow Data (For Single Point) Test # House Pressure: Pascals Flow: CFM (50) Ring Used ACH50 =CFM (50) x 60 /House Volume = Method for calculating building volume.` 0 Retrieved from architectural plans PASS ❑ FAI L Code Software calculated, ACH(50) is less than 3, Mechanical Ventilation installation must ❑When 0 Field measured and calculated be verified by building department. Testing, Testing shall be conducted in accordance with AN$I/RE5NET/lCC 380 and reported at a pressure or 0.2 inch w.g» (50 pascals). Testing shall be Conducted by either individual as defined in Section 553.993(5) or (7), Florida Statues, or individuals licensed as sot forth In Section 489.105(3)(f), (g), or (1) or an approved third party, A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. TestingComp; nay RunBrook, LLC 561-510-5715 Company Name. Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 61h Edition Florida Building Code Energy Conservation requirements according to the ompliance method selected above. Signature of Tester: Date of Test: L(7 y� Printed Name of Tester: Frank Costagliol 0 License/Certification #: 3243649 Issuing Authority: RESNET r. RUNBROOK Duct Leakage Test Report GREEN BUILDII►alp . NERGYTESTIN.t. Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition jurisdiction: Permit #: II� ,- Ukj ,fob information Builder: K Hovnanian Community:(c, Lot: Address: M` Unit: -,IF IF City: pk(L IF State: FL Zip�� C cri... I Duct Leakage Test Results ___ _IF .._ Prescriptive Method cfm25 (Total) IF IF 0 S stem 1 Y F F I I �- cfm25 ITo qualify as "substantially leak free" Qn must be less than or equal to System 2 0.04 if air handler unit is installed. If air handler unit is not installed, cfm25 Qn Total must be less than or equal to 0.03. This testing method System 3 meets the requirements in accordance with Section R403.3.3. cfm25 um of any N additional systems cfm25 PRO o Performance/ ERI Method cfm25 (out or Total) Total of all To qualify using this method, Qn must not be greater than the systems } cfm25 proposed duct leakage Qn specified on Form R405-2017 or R40&2,017. IF F .Qn n specified on form R405-2014 Leakage Type selected on Form Q Total of all Total Coo nditioned systems Square Footage R405-2017 (EnergyCalc) or R40&2017 (Energy Calc) or 40&2097 I ASS FAI L Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes, Testing Company RunBrook, LLC -510 -5715 Company Name: Phone: 561 I hereby verify that the above duct leakage testing results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: -r=` y Date of Test: 5/o/a Frank Costagliola Printed Name of Tester: