Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
jurisdiction:
Permit #:
Job information IL
Builder: K Hovnanian Community: LeLot:
�►.
Unit:
Address:, (�3
1"
City: ��r ��c rc State: FL Zip:
House S.F:
Avg. Ceiling Height.
Total Volume:
Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method
OPRESCRIPTIVE METHOD The building or dwelling unit shall be tested and verified as having an air leakage rate or not exceeding 7 air
change 'per hour at a pressure of 0'.2-lnch w.g. (50 pascals) in climate zones I and 2.
r PeERFORMANCE OR ERI METHOD T The building or dwelling unit shall be tested and verified as having an air leakage rate of not
exceeding the selected ACH(50) value, as shown on FORM 14405-2017 (performance) or R40&2017 (FRI), section labeled as infiltration, sub"
section ACH:
ACH(50) specified on Form R405S 20174nergy Calc (Performance) or R406,TV, 017 (ERI): ;
Pressure & Flow Data (For Single Point)
Test #
House Pressure: Pascals
Flow: CFM (50)
Ring Used
ACH50 =CFM (50) x 60 /House Volume = Method for calculating building volume.`
0 Retrieved from architectural plans
PASS ❑ FAI L
Code Software calculated,
ACH(50) is less than 3, Mechanical Ventilation installation must
❑When
0 Field measured and calculated
be verified by building department.
Testing, Testing shall be conducted in accordance with AN$I/RE5NET/lCC 380 and reported at a pressure or 0.2 inch w.g» (50 pascals). Testing shall be
Conducted by either individual as defined in Section 553.993(5) or (7), Florida Statues, or individuals licensed as sot forth In Section 489.105(3)(f), (g), or (1) or
an approved third party, A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing
shall be performed at any time after creation of all penetrations of the building thermal envelope.
TestingComp; nay
RunBrook, LLC 561-510-5715
Company Name. Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2017 61h Edition Florida Building Code
Energy Conservation requirements according to the ompliance method selected above.
Signature of Tester: Date of Test: L(7 y�
Printed Name of Tester: Frank Costagliol
0
License/Certification #: 3243649 Issuing Authority: RESNET
r.
RUNBROOK
Duct Leakage Test Report
GREEN BUILDII►alp . NERGYTESTIN.t.
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
jurisdiction:
Permit #: II� ,- Ukj
,fob information
Builder: K Hovnanian
Community:(c, Lot:
Address:
M`
Unit:
-,IF
IF
City:
pk(L
IF
State: FL
Zip��
C cri...
I
Duct Leakage Test Results
___ _IF
.._
Prescriptive Method cfm25 (Total) IF IF
0
S stem 1
Y
F F I I
�-
cfm25
ITo qualify as "substantially leak free" Qn must be less than or equal to
System 2
0.04 if air handler unit is installed. If air handler unit is not installed,
cfm25
Qn Total must be less than or equal to 0.03. This testing method
System 3
meets the requirements in accordance with Section R403.3.3.
cfm25
um of any
N
additional systems
cfm25
PRO
o Performance/ ERI Method cfm25 (out or Total)
Total of all
To qualify using this method, Qn must not be greater than the
systems }
cfm25
proposed duct leakage Qn specified on Form R405-2017 or R40&2,017.
IF F
.Qn n specified on form R405-2014
Leakage Type selected on Form Q
Total of all Total Coo nditioned
systems Square Footage
R405-2017 (EnergyCalc) or R40&2017 (Energy Calc) or 40&2097
I ASS
FAI L
Duct tightness shall be verified
by testing in
accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section
553.993(5) or (7), Florida Statutes, or individuals
licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes,
Testing Company
RunBrook, LLC -510 -5715
Company Name: Phone: 561
I hereby verify that the above duct
leakage
testing results are in accordance with the 2017 6th Edition Florida Building Code Energy
Conservation requirements according to the compliance method selected above.
Signature of Tester:
-r=` y Date of Test: 5/o/a
Frank Costagliola
Printed Name of Tester: