Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Engineering
BUILDINGS PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPONENTS A CLADDING (8SF.) FOR ASCE 7-16 - PEAK ROOF HEIGHT LESS THAN OR EQUAL TO 60 FEET BASIC WIND SPEED - 770 mph RISK CATEGORY Il BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS& COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) PFAK L-LESS THAN 7'-9' L"GREATER OR EQUAL THAN 7'-9'AND L-GREATER OR EQUAL THAN 12'-3" ROOF LESS THAN 12'-5' HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE POSITIVE NEGATIVE (h) ULTIMATE A.S.D. ULTIMATE A.S.O. -ULTIMATE A.S.O. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. * INDICATED DESIGN WIND PRESSURES O'- 15, 76.4 45.8 102.4 61.4 7J.0 43.8 95.5 573 68.5 41.1 86.4 51.8 CORRESPOND TO THE MAXIMUM END > 15'-20' 80.4 48.2 1076 64.6 76.8 46.1 100.4 60.2 72.0 43.2 ZONE AND INTERIOR ZONE CONDITIONS 90.8 54.5 AND FOR ALL ROOF >20'-25' 83.6 50.2 111.9 671 79.8 47.9 104.4' 62.6 74.8 44.9 94.4 56.6 SLOPES. >25'-a0' 86.2 51.7 115.5 69.3 82.4 49.4 107.7 64.6 77.3 46.4 97,4 58.4 **L ACCORD N SHUTTER' >30'-40' 90.7 54.4 121.4 72.8 86.6 52.0 11J.3 68.0 81.2 48.7 102.4 61.4 BLADE LENGTH OR BAHAMA ' SHUTTER HEIGHT. _ >40'-50' 94.3 56.6 126.2 75.7 90.0 54.0 117.7 70.6 84.4 50.6 T06.5 63.9 *at* PRODUCTS WHICH BEAR A >50'-60' 97.3 58.4 730.J 7B.2 92.9 55.7 121.5 72.9 87.2 52.3 109.9 65.9 NUNI-DAD£COUNTY OR A STATE OF FLORIDA APPROVAL BUILDINGS PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPONENTS & CLADDING (P.SF.) FOR ASCE 7-16 - PEAK ROOF HEIGHT GREATER THAN 60 FEFT* BASIC WIND SPEED - 170 mph RISK CATEGORY 11 BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS& COMMERCIAL BUILDINGS(RETAIL, WHOLESALE) P¢oOf C� �E1 PEAK L••LESS THAN 12-3" L-GREATER OR EQUAL THAN 12=3' ROOF HEIGHT POSI17VE NEGATIVE POSITIVE NEGARVf (h) ULTIMATE A.S.D. ULTIMATE A.S.O. ULTIWT£ A.S.D. ULTIMATE A.S.D. >60'-70' 91.5 54.9 1677 100.6 84.3 50.6 148.4 89.0 BUILDING SCHEMATIC > 70'-80' 93.6 56.2 171.6 103.0 86.2 51.7 151.9 91.1 >Bo'-9o' 95.6 574 175.2 105.1 88.0 52.8 155.0 9J.0 >9o,- too' 97J 5B.4 178.4 1074 89.7 53.8 1579 94.7 �> too..'_ 120'' 100.5 (,60,3' •,, 184.2 L,1'J0.S' 92.5 55.5 163.0 97.8 1`20'""14(T 103.2 61.9- 189.2 113.5 95.1 57.1 167.4 100.4 \``�����R > 140'= 160' 105.6 63.4 193.6 116.2 97J 58.4 171.3 102.8 ��Q�.,••"• ,7 4 > 16D'- 180, 1078 64.7 1976 118.6 99.3 59.6 174.9 104.9 `.`y�;• �\GENSF*•'•:P > 180'-200' 109.8 65.9 201.J 120.8 101.1 60.7 178.1 106.9 = N0.44167 >200'-250' 114.1 68.5 209.2 125.5 105.2 63.1 185.1 111.1 >250'-JOO' 117.8 70.1 216.0 129.6 108.5 65.1 191.1 114.7 = = = o'•• STATE OF >300'-J50' 121.0 72.6 221.9 1J3.1 111.5 66.9 196.3 1178 •�[L, >350'-400' 123.9 74.J 227.1 136.3 114.1 68.5 200.9 120.5 >400'-450' 126.4 75.8 231.8 1J9.1 116.5 69.9 205.1 12J.1 L7F J IING >450'-500' 126.8 77.3 236.1 141.7 118.E 71.2 208.9 725.3 �(1Ni1 f 00 NOES., I.)THIS CERTIFIED SIGNED AND SEALED WIND LOAD CHART,PREPARED BY THIS ENGINEER,BASED ON ASCE 7-16,FOR A BASIC WIND SPEED OF 170 MPH,AND 2020(7th EDMON)FLORIDA BUILDING CODE-BROWARD,PALM BEACH,MARTIN,ST. LUCI£&1ND14N RIVER COUNUES APPLICABLE RISK CATEGORY BUILDING&EXPOSURES IS COMPLETELY GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT. 2)'IH/S WIND LOAD CHART MUST BE SIGNED,SEALED AND DATED BY THIS ENGINEER IF 02020 MIECO,INC ASCE 7-16/ WIND PRESSURE CHART USED 70 OBTAIN A ONE TIME BUILDING PERMIT. STORM PANELS ACCORDION&&H"SHUTTERS DRA MP WN BY J.)CONTRACTOR OR PERMIT HOLDER TO BE RESPONSIBLE FOR THE SELECT/ON OF DESIGN WIND PRESSURE BASED ON THIS GENERIC WIND LOAD CHART. RISK CAT: !I SLOGS 0612312020 WIND PRESSURES ARE ULTIMATE AND A.S.O.PRESSURES. DATE 4.)THIS WIND LOAD CHART SHALL BE CONSIDERED INVALID!f ALTERED BY ANY MEANS. TILUT TESTING t ENGlNEFF/NO L E C O,M C.COMPANY WIND PRESSURE CHART ^ ate NM.JM2 S,M..X11,MACu¢7 GAYOTNS Tt mi. BASIC WIND SPEED= 170 mph \ ) 5.)DESIGN WIND LOAD SELECTED BY THE CONTRACTOR OR PERMIT HOLDER FROM THIS WIND LOAD CHART SHALL BE INDICATED ON A SEPARATE DOCUMENT PREPARED BY Prop:(wsleTr-rsw.r:(wlen-Issr EXPOSURE A Kd=0.85 20-117 THE CONTRACTOR OR PERMIT HOLDER(.p.,SPREADSHEET,OPENING SCHEDULE/TAKE OFF SHEET,ETC.). FA-0006719 DRAWING No WAITER A RLUT Jr.P. rNO ° ^"^' urs e[K w oocwrd ars r ,, FLORIDA Ue.[44167 a0 n-roe vV r SHEET 1 OF 1 ,