Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutEnergy Calculation Form & Manual J's FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: TULIP 111 MODEL 4735 SELVITZ ROAD Builder Name: JC&Sons Home Builder, Inc.
Street: 4735 SELVITZ ROAD Permit Office: ST. LUCIE COUNTY
City,State,Zip: PORT ST.LUCIE,FL, Permit Number:1705-0035
Owner: Jurisdiction:
Design Location: FL, Fort Pierce County:: ST.LUCIE COUNTY(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(2531.7 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Ext Insul, Exterior R=4.1 2351.70 ft2
b.Frame-Wood, Exterior R=11.0 180.00 ft2
3. Number of units,if multiple family 1 c.N/A
R= ft2
4. Number of Bedrooms 5 d.N/A R= ft2
5. Is this a worst case? No 10.Ceiling Types (2783.0 sqft.) Insulation Area
a. Roof Deck(Unvented) R=20.0 2783.00 ft2
6. Conditioned floor area above grade(ft2) 2783 b. N/A R= ft2
Conditioned floor area below grade(ft2) 0 c R= ft2
11.Ducts R ft2
7. Windows(391.1 sqft.) Description Area a.Sup:Attic, Ret:Attic,AH:Garage 6 325
a. U-Factor: Sgl,U=0.65 391.07 ft2
SHGC: SHGC=0.25
b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: a.Central Unit 46.5 SEER:16.00
c. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a. Electric Strip Heat 34.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 3.370 ft.
Area Weighted Average SHGC: 0.250 14. Hot water systems
8. Floor Types (2783.2 sqft.) Insulation Area a.Electric Cap:50 gallons
a.Slab-On-Grade Edge Insulation R=0.0 2783.20 ft2 b. Conservation features EF:0.950
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.141
Total Proposed Modified Loads: 85.97 PASS
Total Baseline Loads: 92.17
1 hereby certify that the plans and specifications covered by Review of the plans and O�T$E Sr'4?�
.this calculation are in compliance with the Florida Energy specifications covered by this O�
Code. calculation indicates compliance
with the Florida Energy Code. ti ifill/
PREPAWD Y: Before construction is completed
DATE' this building will be inspected for O i a
compliance with Section 553.908 * e
1 hereby certify that this.building, as designed, is in com?aQze Florida Statutes. 5�
with the Florida Ener G'pD WE
OWNER/AGENT: BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
8/10/2017 10:51 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2014
PROJECT
Title: TULIP 111 MODEL 4735 SEL Bedrooms: 5 Address Type: Street Address
Building Type: User Conditioned Area: 2783 Lot#
Owner: Total Stories: 1 Block/SubDivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: JC&Sons HOme Builder, Inc Rotate Angle: 0 Street: 4735 SELVITZ ROAD
Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: ST.LUCIE COUNTY
Jurisdiction: Whole House Fan: No City,State,Zip: PORT ST.LUCIE,
_ Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment:
CLIMATE
IECC Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
1 Entire House 2783 25470.8
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 BEDROOM 2 180 1440 No 1 1 1 Yes Yes Yes
2 BATH 2 72 576 No 0 1 Yes Yes Yes
3 BEDROOM 3 180 1440 No 1 1 1 Yes Yes Yes
4 BATH 3 72 576 No 0 1 Yes Yes Yes
5 BEDROOM 4 213 1704 No 1 1 1 Yes Yes Yes
6 HALL 63 504 No 0 1 No Yes Yes
7 LIVING ROOM 304 3040 No 1 1 Yes Yes Yes
8 FOYER 148 1480 No 0 1 Yes Yes Yes
9 KITCHEN 234 2340 Yes 0 1 Yes Yes Yes
10 DINING 198 1980 No 0 1 Yes Yes Yes
11 MASTER BEDROO 361 3610 No 1 1 1 Yes Yes Yes
12 WIC 60 480 No 0 1 No Yes Yes
13 MASTER BATH 125 1000 No 0 1 Yes Yes Yes
14 LAUNDRY 61 488 No 0 1 No Yes Yes
15 A/C 20 188 No 0 1 No Yes Yes
16 SUITE#2 378 3553.2 No 0 1 1 Yes Yes Yes
17 BATH#3 60 564 No 0 1 Yes Yes Yes
18 CABANA 54 507.6 No 0 1 Yes Yes Yes
8/10/2017 10:51 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6
FORM R405-2014
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft2 ---- 0 1 0
2 Slab-On-Grade Edge Insulatio BATH 2 6 ft 0 72 ft2 ---- 0 1 0
3 Slab-On-Grade Edge Insulatio BEDROOM 3 15 ft 0 180 ft2 ---- 0 1 0
4 Slab-On-Grade Edge Insulatio BATH 3 6 ft 0 72 ft2 ---- 0 1 0
5 Slab-On-Grade Edge Insulatio BEDROOM 4 34 ft 0 213 ft2 ---- 0 1 0
6 Slab-On-Grade Edge Insulatio HALL 1 ft 0 63 ft2 ---- 0 1 0
7 Slab-On-Grade Edge Insulatio LIVING ROOM 16 ft 0 304 ft2 ---- 0 1 0
8 Slab-On-Grade Edge Insulatio FOYER 9 ft 0 148 ft2 ---- 0 1 0
9 Slab-On-Grade Edge Insulatio KITCHEN 9 ft 0 234 ft2 ---- 0 1 0
10SIab-On-Grade Edge Insulatio DINING 11 ft 0 198 ft2 ---- 0 1 0
11SIab-On-Grade Edge Insulatio MASTER BEDRO 49 ft 0 361 ft2 ---- 0 1 0
12SIab-On-Grade Edge Insulatio WIC 1 ft 0 60 ft2 ---- 0 1 0
13SIab-On-Grade Edge Insulatio MASTER BATH 14 ft 0 125 ft2 ---- 0 1 0
14SIab-On-Grade Edge Insulatio LAUNDRY 1 ft 0 61 ft2 ---- 0 1 0
15SIab-On-Grade Edge Insulatio A/C 1 ft 0 20 ft2 ---- 0 1 0
16SIab-On-Grade Edge Insulatio SUITE#2 45 ft 0 378.2 ft2 ---- 0 1 0
17SIab-On-Grade Edge Insulatio BATH#3 16 ft 0 60 ft2 ---- 0 1 0
18SIab-On-Grade Edge Insulatio CABANA 15 ft 0 54 ft2 ---- 0 1 0
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 2933 ft2 0 ft2 Medium 0.6 No 0.9 No 20 18.4
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Unvented 0 2783 ft2 N N
8/10/2017 10:51 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 6
FORM R405-2014
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Unvented) BEDROOM 2 20 Blown 180 ft2 0.1 Wood
2 Under Attic(Unvented) BATH 2 20 Blown 72 ft2 0.1 Wood
3 Under Attic(Unvented) BEDROOM 3 20 Blown 180 ft2 0.1 Wood
4 Under Attic(Unvented) BATH 3 20 Blown 72 ft2 0.1 Wood
5 Under Attic(Unvented) BEDROOM 4 20 Blown 213 ft2 0.1 Wood
6 Under Attic(Unvented) HALL 20 Blown 63 ft2 0.1 Wood
7 Under Attic(Unvented) LIVING ROOM 20 Blown 304 ft2 0.1 Wood
8 Under Attic(Unvented) FOYER 20 Blown 148 ft2 0.1 Wood
9 Under Attic(Unvented) KITCHEN 20 Blown 234 ft2 0.1 Wood
10 Under Attic(Unvented) DINING 20 Blown 198 ft2 0.1 Wood
11 Under Attic(Unvented) MASTER BEDRO 20 Blown 361 ft2 0.1 Wood
12 Under Attic(Unvented) WIC 20 Blown 60 ft2 0.1 Wood
13 Under Attic(Unvented) MASTER BATH 20 Blown 125 ft2 0.1 Wood
14 Under Attic(Unvented) LAUNDRY 20 Blown 61 ft2 0.1 Wood
15 Under Attic(Unvented) A/C 20 Blown 20 ft2 0.1 Wood
16 Under Attic(Unvented) SUITE#2 20 Blown 378 ft2 0.1 Wood
17 Under Attic(Unvented) BATH#3 20 Blown 60 ft2 0.1 Wood
18 Under Attic(Unvented) CABANA 20 Blown 54 ft2 0.1 Wood
WALLS
Adjacent R_Va�lp Et In Et In R-Nhahle
10 _ypeSpace Cavity Width Height Sheathing Framing Solar Below
1 E Exterior Concrete Block-Ext IndKDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.6 0
2 E Exterior Concrete Block-Ext Insul BATH 2 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0
3 E Exterior Concrete Block-Ext ImEEDROOM 3 4.1 15 0 8 0 120.0 ft2 0 0 0.6 0
4 E Exterior Concrete Block-Ext Insul BATH 3 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0
5 E Exterior Concrete Block-Ext InOEDROOM 4 4.1 13 0 8 0 104.0 ft2 0 0 0.6 0
6 S Exterior Concrete Block-Ext InfiffDROOM 4 4.1 15 0 8 0 120.0 ft2 0 0 0.6 0
7 W Exterior Concrete Block-Ext InfiffDROOM 4 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0
8 S Exterior Concrete Block-Ext InddVING ROO 4.1 16 0 10 0 160.0 ft2 0 0 0.6 0
9 S Exterior Concrete Block-Ext Insul FOYER 4.1 8 0 10 0 80.0 ft2 0 0 0.6 0
10 W Exterior Concrete Block-Ext Insul FOYER 4.1 1 0 10 0 10.0 ft2 0 0 0.6 0
11 N Exterior Concrete Block-Ext InsuKITCHEN 4.1 9 0 10 0 90.0 ft2 0 0 0.6 0
12 N Exterior Concrete Block-Ext Insul DINING 4.1 11 0 10 0 110.0 ft2 0 0 0.6 0
13 N Exterior Concrete Block-Ext InsMASTER BE 4.1 19 0 10 0 190.0 ft2 0 0 0.6 0
_14 E Exterior Concrete Block-Ext InsMASTER BE 4.1 11 0 10 0 110.0 ft2 0 0 0.6 0
_15 W Exterior Concrete Block-Ext In4dASTER BE 4.1 19 0 10 0 190.0 ft2 0 0 0.6 0
16 W Exterior Concrete Block-Ext InEMASTER BA 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0
17 E Exterior Concrete Block-Ext InsuSUITE#2 4.1 18 0 9 5 169.5 ft2 0 0 0.6 0
18 W Exterior Concrete Block-Ext InsuSUITE#2 4.1 27 0 9 5 254.3 ft2 0 0 0.6 0
_19 N Exterior Concrete Block-Ext InsuBATH#3 4.1 10 0 9 5 94.2 ft2 0 0 0.6 0
_20 E Exterior Concrete Block-Ext InsuBATH#3 4.1 6 0 9 5 56.5 ft2 0 0 0.6 0
_21 N Exterior Concrete Block-Ext InsuICABANA 4.1 9 0 9 5 84.8 ft2 0 0 0.6 0
_22 W Exterior Concrete Block-Ext InsuICABANA 4.1 6 0 9 5 56.5 ft2 0 0 0.6 0
8/10/2017 10:51 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6
FORM R405-2014
WALLS
Adjacent Cavity ity Width Height Sheathing Framing Solar Below
()rnt To MIMI Type
le Et In Ft In Area R-1/allie Ecartoon AhSor r4rarle%
23 N Exterior Frame-Wood CABANA 11 20 9 180.0 ft2 0.23 0.6 0
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 E 1 Metal Low-E Single Yes 0.65 0.25 33.8 ft2 1 ft 4 in 1 ft 4 in None None
2 E 2 Metal Low-E Single Yes 0.65 0.25 9.0 ft2 1 ft 4 in 1 ft 4 in None None
3 E 3 Metal Low-E Single Yes 0.65 0.25 33.8 ft2 1 ft 4 in 1 ft 4 in None None
4 E 4 Metal Low-E Single Yes 0.65 0.25 9.0 ft2 1 ft 4 in 1 ft 4 in None None
5 S 6 Metal Low-E Single Yes 0.65 0.25 33.8 ft2 1 ft 4 in 1 ft 4 in None None
6 S 8 Metal Low-E Single Yes 0.65 0.25 22.1 ft2 8 ft 0 in 1 ft 4 in None None
7 S 8 Metal Low-E Single Yes 0.65 0.25 22.6 ft2 8 ft 0 in 1 ft 4 in None None
8 N 11 Metal Low-E Single Yes 0.65 0.25 13.6 ft2 8 ft 0 in 1 ft 4 in None None
9 N 12 Metal Low-E Single Yes 0.65 0.25 61.2 ftz 8 ft 0 in 1 ft 4 in None None
10 N 13 Metal Low-E Single Yes 0.65 0.25 22.2 ft' 1 ft 4 in 1 ft 4 in None None
11 N 13 Metal Low-E Single Yes 0.65 0.25 22.7 ft' 1 ft 4 in 1 ft 4 in None None
12 E 14 Metal Low-E Single Yes 0.65 0.25 17.7 ft2 1 ft 4 in 1 ft 4 in None None
13 W 16 Metal Low-E Single Yes 0.65 0.25 11.3 ft2 1 ft 4 in 1 ft 4 in None None
14 E 17 Metal Low-E Single Yes 0.65 0.25 45.4 ft2 1 ft 4 in 1 ft 4 in None None
15 W 18 Metal Low-E Single Yes 0.65 0.25 19.4 ft2 1 ft 4 in 1 ft 4 in None None
16 N 19 Metal Low-E Single Yes 0.65 0.25 6.9 ft2 1 ft 4 in 1 ft 4 in None None
17 N 21 Metal Low-E Single Yes 0.65 0.25 6.9 ft2 1 ft 4 in 1 ft 4 in None None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 480 ft2 480 ft2 20 ft 9 ft 11
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000407 2971.6 163.14 306.8 .2972 7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Strip Heat None COP:1 34 kBtu/hr 1 sys#1
8/10/2017 10:51 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6
FORM R405-2014
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER: 16 46.5 kBtu/hr 1395 cfm 0.8 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
--Supply--- ---Return-- Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 325 ft2 Attic 105 ft2 Default Leakage Garage (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans: rl
Heating HJan HFeb Mar Apr May Apr May rl Jun IX�Jul Aug rj Sep �jOct HNNov Dec
ov HDecVenting Jan Feb X Mar Jun Jul Aug Sep
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
8/10/2017 10:51 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 6
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: TULIP 111 MODEL 4735 SELVITZ ROAD Builder Name: JC&Sons Home Builder, Inc.
Street: 4735 SELVITZ ROAD Permit Office: ST.LUCIE COUNTY
City,State,Zip: PORT ST.LUCIE,FL, Permit Number:1705-0035
Owner: Jurisdiction:
Design Location: FL,Fort Pierce
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall not be used as a sealing material.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings,drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
• Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls,or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
8/10/2017 10:51 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 93
The lower the EnergyPerformance Index, the more efficient the home.
4735 SELVITZ ROAD, PORT ST. LUCIE, FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Ext Insul, Exterior R=4.1 2351.70 ftz
b.Frame-Wood,Exterior R=11.0 180.00 ft
3. Number of units,if multiple family 1 c.N/A R= ftZ
4. Number of Bedrooms 5 d.N/A R= ftZ
5. Is this a worst case? No 10.Ceiling Types Insulation Area
a.Roof Deck(Unvented) R=20.0 2783.00 ftZ
6. Conditioned floor area(ftZ) 2783 b.N/A R= ft2
c. N/A R= ftZ
7. Windows— Description Area 11. Ducts R ftZ
a. U-Factor: Sgl, U=0.65 391.07 ftZ a.Sup:Attic,Ret:Attic,AH:Garage 6 325
SHGC: SHGC=0.25
b. U-Factor: N/A ftZ
SHGC: 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ftZ a.Central Unit 46.5 SEER:16.00
SHGC:
d. U-Factor: N/A ftZ 13.Heating systems kBtu/hr Efficiency
SHGC: a. Electric Strip Heat 34.0 COP:1.00
Area Weighted Average Overhang Depth: 3.370 ft.
Area Weighted Average SHGC: 0.250
8. Floor Types Insulation Area 14.Hot water systems
a.Electric Cap:50 gallons
a.Slab-On-Grade Edge Insulation R=0.0 2783.20 ftZ EF:0.95,
b.N/A R= ftZ
c.N/A R= ftZ b. Conservation features
None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building �gE sT
Construction through the above energy saving features which will be installed (or exceeded) 0
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home: City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
8/10/2017 10:51 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
Pro ect Summa Job:
- wrightsoft® Entire House Date:
By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772466-6796 Email:QUICKCALCS@4OL.COM
Proaect Information
For: TULIP MODEL III
4735 SELVITZ ROAD, FT. PIERCE, FL 34981
Notes:
Desiqn Information
Weather: Fort Pierce, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 42 OF Outside db 90 OF
Inside db 70 OF Inside db 75 OF
Design TD 28 OF Design TD 15 OF
Daily range L
Relative humidity 50 %
Moisture difference 61 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 37441 Btuh Structure 33334 Btuh
Ducts 18 Btuh Ducts 12 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 37459 Btuh Use manufacturer's data n
Rate/swing multiplier 0.95
Infiltration Equipment sensible load 31679 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 3842 Btuh
Ducts 3979 Btuh
Central vent(0 cfm) 0 Btuh
Heating Cooling (none)
Area(ftz) 2783 2783 Equipment latent load 7821 Btuh
Volume(ft') 25513 25513
Air changes/hour 0.32 0.16 Equipment total load 39500 Btuh
Equiv.AVF (cfm) 136 68 Req. total capacity at 0.70 SHR 3.8 ton
Heating Equipment Summary Cooling Equipment Summary
• Make Make Rheem
Trade Trade RHEEM
Model Cond RA1648AJ 1 N B
AHRI ref Coil RH1T4821MTANJA
AHRI ref 8080956
Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER
Heating input 7.8 kW Sensible cooling 32550 Btuh
Heating output 26682 Btuh Latent cooling 13950 Btuh
Temperature rise 16 OF Total cooling 46500 Btuh
Actual air flow 1550 cfm Actual air flow 1550 cfm
Air flow factor 0.041 cfm/Btuh Air flow factor 0.046 cfm/Btuh
Static pressure 0.50 in H2O Static pressure 0.50 in H2O
Space thermostat Load sensible heat ratio 0.81
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
WI'1 htsoft' 2017-Aug-1011:15:22
9 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 1
ACCk ...Documents\TULIP 111 MODEL-4735 SELVITZ ROAD.rup Cale=MJ8 Front Door faces: N
wrightsoft° Right-J®Worksheet Job:
Entire House Date:
By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name Entire House BEDROOM 3
2 Exposed wall 257.0 ft 12.0 ft
3 Room height 9.2 ft d 8.0 ft heat/cool
4 Room dimensions 15.0 x 12.0 ft
5 Room area 2783.0 112 180.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A-4ocs 0.143 n 4.00 2.55 569 435 '1743 1108 0 6 0 0
1A-c1om 1.270 n 35.56 34.77 14 0 484 474 0 0 0 0
1A-c1om 1.270 n 35.56 34.77 22 0 784 767 0 0 0 0
1A-clom 1.270 n 35.56 34.77 23 0 803 785 0 0 0 0
11 1A-c1omd 1.270 n 35.56 34.77 61 0 2176 2128 0 0 0 0
4A5-2om- _ _ 0.770 n- 21.56 _ 19.31 _ 14 0 - _ 299 _ 268 0 0 _ 0- 0
13A-4ocs 0.143 a 4.00 2.55 752 649 2598 1652 96 62 250 159
10A-m 1.670 a 46.76 53.19 18 0 821 934 0 0 0 0
1A-clom 1.270 a 35.56 84.36 18 2 640 1518 0 0 0 0
lA-c1om--_- _1.270 a 3.5.56-_._87.90 _ 67 34- 4 2390 5907 ___ 2_ _ _1195 _. 2953
W 13A-flocs 0.143 s 4.00 2.55 360 261 1044 664 0 0 6 0
IA-clom 1.270 s 35.56 34.77 34 34 1195 1168 0 0 0 0
1A-clom 1.270 s 35.56 34.77 22 22 784 767 0 0 0 0
1A-clom 1.270 s 35.56 34.77 23 23 803 785 0 0 0 0
_11DO - ___. 0.390 s. 10.92 _ __11.31 21 _ 21 _ _-229 _ 238-- __ 0 0___ _ 0 -0
N
13A-flocs 0.143 w 4.00 2.55 670 595 2381 1513 0 0 0 0
1A-clom 1.270 w 35.56 83.01 11 2 400 934 0 0 0 0
4A5-tom 0.770 w 21.56 45.52 45 3 973 2055 0 0 0 0
4A5-2om- ,-_- --_- --- _- 0.770 w 21.56_._45.63 _ _._. 19__ 1 415 _ 879, - ,- 0 0 - -- -_0 _. 0
P_ _ _ 12C-0sw 0.091 2.55 _ 1.28 299 _ 299_ .- . 762 .384 0 0 0 0
C __ 16X19-0md _ 0.408 1.59 _- 1.49 _ 2783 _ 2783 4413 _ 4136 _ 180 _ 180__- _ 285 __267
F ' _22A-tp1 __ _ 0.989_-- - 27.69 0.00_ 2783 257 __ 7117 0_. _180- 12 _ 332
6 c)AED excursion 0 -6
Envelope loss/gain 33254 29063 2062 3373
12 a) Infiltration 4187 1122 171 46
b) Room ventilation 0 0 0 0
13 Intemal gains: Occupants @ 230 5 1150 1 230
Appliances/other 2000 0
Subtotal(lines 6 to 13) 37441 33334 2233 3649
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 37441 33334 2233 3649
151 Duct loads 0% 0% 18 12 0% 0% 0 0
Total room load 37459 33M 2233 3649
Air required(cfm) 15501 1550 92 170
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
- wrigFrtsoft' 2017-Aug-10 11:15:22
Right-Suite®Universal 2017 17.0.14 RSU08101 Page 1
ACC` ...Documents\TULIP 111 MODEL-4735 SELVITZ ROAD.rup Calc=MJ8 Front Door faces: N
- wrightsoft° Right-J®Worksheet Job:
Entire House Date:
By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name BATH#4 BEDROOM 4
2 Exposed wall 6.0 ft 15.0 ft
3 Room height 8.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 12.0 x 6.0 ft 12.0 x 15.0 ft
5 Room area 72.0 ft' 180.0 ftz
Ty Construction U-value Or HTM Area (ftz) Load Area (ft� Load
number (Btuh/ftL°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A-4ocs 0.143 n 4.00 2.55 0 0 0 0 0 0 0 6
1A-clom 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
IA-clom 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
IA-c1om 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
11 1Aclomd 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
4A5-2om._ ____ 0.770 n- 21.56 _ 19.31 0 0 _ __ 0 . 0- 0 0 _ _ 0 _0
22 13A-4ocs 0.143 a 4.00 2.55 48 39 156 99 120 86 346 0
10A-m 1.670 a 46.76 53.19 0 0 0 0 0 0 0 0
IA-clom 1.270 a 35.56 84.36 9 1 320 759 0 0 0 0
_1A-c1om. _ 1.270 _e 35.56 ._ 87.90 .. _0. 0 _ ___0 0 ._ _ 34 2_ _ 1195 2953
13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0
1A-clom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
1A-clom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
1A-c1orn 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
_11DO _ _- ___ 0.390 s 10.92 __.11.31 0 - 0_ _. - .__0 0 0 _ _0 0 0
VVV���III 13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0
IA-c1om 1.270 w 35.56 83.01 0 0 0 0 0 0 0 0
4A5.2om 0.770 w 21.56 45.52 0 0 0 0 0 0 0 0
Vh 4A5.2om _ 0.770 .w 21.56 45.63 0 0 0 0 _ _ _ 0 0 0 0
P _ _ 12C-Osw.' 0.091 - _ _ 2.55 1.28 0 0 0 0 0,_ 0 _ 0 . 0
C 16X19-0md 0.408 - 1.59 _ 1.49 72 72 114 107 180 160 285 267
F 22A-tpl 0.989 - 27.69 _0.00 72 6 166 _ 0 180 15 _ _ 415 __0
6 c)AED excursion -31 -11
Envelope loss/gain 757 934 2242 3429
12 a) Infiltration 86 23 214 57
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 1 230
Appliances/other 0 0
Subtotal(lines 6 to 13) 842 957 2455 3717
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 842 957 2455 3717
15 Duct Icads 0% 0% 0 0 0% 0% 0 0
Total room load 842 957 2455 3717
Air required(cfm) 35 44 102 173
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
- - wrigF�tsoft' 2017-Aug-10 11:15:22
Right-Suite®Universal 2017 17.0.14 RSU08101 Page 2
'CC�` ...Documents\TULIP 111 MODEL4735 SELVITZ ROAD.rup Calc=MJ8 Front Door faces: N
- wrightsoft° Right-J®Worksheet Job:
Entire House Date:
By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax.772-466-6796 Email:QUICKCALCS@4OL.COM
1 Room name BATH#5 BEDROOM 5
2 Exposed wall 6.0 ft 34.0 ft
3 Room height 8.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 12.0 x 6.0 ft 1.0 x 213.0 ft
5 Room area 72.0 ft2 213.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft� Load
number (Btuh/ -°F) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A-4ocs 0.143 n 4.00 Z55 0 0 0 0 0 0 0 0
1A-c1om 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
1A-c1om 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
1A-ciom 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
11 1A-c1omd 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
.4A5-2om_____ ____ _ _ .'0.770 n. 21.56 _ 19.31 __ 0 _ . . _ 0 0 0- 0 _ 0 _____ 0 _0
N13A-4ocs 0.143 a 4.00 2.55 48 39 156 99 104 104 416 265
10A-m 1.670 a 46.76 53.19 0 0 0 0 0 0 0 0
1A-c1om 1.270 a 35.56 84.36 9 1 320 759 0 0 0 0
1A-glom_ ._. 1.270 a 35.56_,. _87.90 _ ._ ....0... 0 _.... 0 0 0 0 0 - 0
13A-4ocs 0.143 s 4:00 2.55 0 0 0 0 120 86 346 220
1A-c1om 1.270 s 35.56 34.77 0 0 0 0 34 34 1195 1168
1A-c1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
1A-c1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
11DO - __-.____ 0.390.- s 10.92. 11.31 .0 0. _.- 0 0 -0 __0_ - 0 _ 0
13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 48 48 192 122
1A-c1om 1.270 w 35.56 83.01 0 0 0 0 0 0 0 0
4A5-2om 0.770 w 21.56 45.52 0 0 0 0 0 0 0 0
4A5-tom-. _ _ 0.770 w 21.56 45.63 0 0 0 0 0 -0 _ 0 0
P 12C_0sw__ 0.091 - 2.55 1.28 0 0 ._ 0 0_ 0 0 0 _. _ 0
C _ _ 16X1Mmd 0.408 - 1.59 1.49 72 72 114 107 213 213 338 317
IF 22A7tpl _ __ 0.989 - 27.69 0.00 72 6 166 0 213 34 _ 942 _ ___ 0
6 c)AED excursion -31 -169
Envelope loss/gain 757 934 3429 1923
12 a) Infiltration 86 23 485 130
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 1 230
Appliances/other 10 0
Subtotal(lines 6 to 13) 842 957 3913 2282
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 842 957 3913 2282
15 Duct loads 0% 0% 0 0 0% 0% 0 0
Total room load 842 957 3913 2282
Air required(cfm) 35 44 162 106
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsoft' 2017-Aug-10 11:15:22
�� Right-Suite®Universal 2017 17.0.14 RSU08101 Page 3
..Documents\TULIP 111 MODEL-4735 SELVITZ ROAD.rup Calc=MJ8 Front Door faces: N
-wrightsoft° Right-M Worksheet Job:
Entire House Date:
By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772466-6796 Email:QUICKCALCS@4OL.COM
1 Room name HALL LIVING ROOM
2 Exposed wall 0 ft 16.0 ft
3 Room height 8.0 ft heat/cool 10.0 ft heat/cool
4 Room dimensions 3.0 x 21.0 ft 16.0 x 19.0 ft
5 Room area 63.0 ftz 304.0 ft'
Ty Construction U-value Or HTM Area (f:2) Load Area (ft� Load
number (Btuh/f:2-*F) (Btuh/ftj or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A-4ocs 0.143 n 4.00 2.55 0 0 0 0 o 0 0 0
1A-clom 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
IA-clom 1.270 n 35.56 34.77 0 0 0 0 0 0 0 -0
1A-clom 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
11 1A-clomd 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
4A5.2om__ 0.770 n 21.56 19.31 ,. 0 _ 0 0 0 _ 0 _ 0 0 _- _ 0
WWWJJJ 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0
1OA-m 1.670 a 46.76 53.19 0 0 0 0 0 0 0 0
1A-clom 1.270 a 35.56 84.36 0 0 0 0 0 0 0 0
1Ac1om.., 1270_ e _ 35.56 87.90 _ _0 _ _ 0 _ _ -0 _ -0 __- 0 _.,0 0
W 13A-4ocs 0.143 s 4.00 2.55 6 0 0 6 160 115 462 2M
91A-c1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
IA-clom 1.270 s 35.56 34.77 0 0 0 0 - 22 22 784 767
IA-clom 1.270 s 35.56 34.77 0 0 0 0 23 23 803 785
- 11DO _._ _ 0.390__s 10.92 11.31 0 _._. _ 0 0 _ 0- ._ . _ 0 .0 . . 0 ._ _0.
13A-4om 1.270 w 4.56 3.01 0 0 0 0 0 0 0 0
1A�1om 1.270 w 35.56 83.01 0 0 0 0 0 0 0 0
4A5-2om 0.770 w 21.56 45.52 0 0 0 0 0 0 0 0
4A5 tom 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0
P 12C-Osw,_._ 0.091 2.56 1.28 0 0 0 0 _ 0 0 0 _ 0
C 16X190md 0.408 - 1.59 1.49 63 63 100 94 304 304 482 _ 452
F- 22A-tpl.__._. 0.989 - 27.69 0.00 _ 63 0 0 0 304 16 443 0
6 c)AED excursion -6 -180
Envelope loss/gain 100 87 2974 2117
12 a) Infiltration 0 0 285 76
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 1 230
Appliances/other 0 0
Subtotal(lines 6 to 13) 100 87 3259 2424
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 100 87 3259 2424
151 Duct loads 18% 14% 18 12 0% 0% 0 0
Total room load 118 100 3259 2424
Air required(cfm) 5 5 1 1 135 113
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wright6oTt" 2017-Aug-10 11:15:22
Right-Suite®Universal 2017 17.0.14 RSU08101 Page 4
'��` ...DocumentslTULIP 111 MODEL-4735 SELVITZ ROAD.rup Calc=MJ8 Front Door faces: N
wrightsoft° Right-M Worksheet Job:
Entire House Date:
By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name FOYER KITCHEN
2 Exposed wall 9.0 ft 9.0 ft
3 Room height 10.0 ft heat/cool 10.0 ft heat/cool
4 Room dimensions 1.0 x 148.0 ft 13.0 x 18.0 ft
5 Room area 148.0 ftz 234.0 ftz
Ty Construction U-value Or HTM Area (ft� Load Area (ft� Load
number (Btuh/ft;°F) (Btuh/ft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 VP 13A-4ocs^ 0.143 n 4.00 2.55 0 0 F 0 ' 0 90 76 306 194
1A-clom 1.270 n 35:58 34.77 0 0 0 0 14 0 484 474
IA-clom 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
IA-clom 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
11 1A-clomd 1.270 n 35.58 34.77 0 0 0 0 0 0 0 0
4A5-2om_ .__ 0.770 -n 21.56 . 19.31 0 .-, -0 0 - 0, 0 0 0 0
13A-nn 1.670 a 4.76 2.19 0 0 0 0 0 0 0 0
10A-m 1.670 a 46.76 53.19 0 0 0 0 0 0 0 0
1Aclom 1.270 a 35.56 84.36 0 0 0 0 0 0 0 0
1A-c1om 1.270 a 35.56 _ _87.90 0 0 0 0 0 __0__ 0 0
w 13A-4ocs - 6.143 s 4.06 2.56 80 59 238 150- 0 0 0 0
IA-c1om ' 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
IA-c1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
1A-clom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
11 DO_ - _ _ _ 0.390 .s 10.92 11.31. 21 _ 21 229 _ 238 0 0- .0 0
1VVl���JJJ 13A-4ocs 0.143 w 4.00 2.55 10 10 40 25 0 0 0 0
1A-clom 1.270 w 35.58 83.01 0 0 0 0 0 0 0 0
4A5-2om 0.770 w 21.58 45.52 0 0 0 0 0 0 0 0
4A5-2om __ 0.770 w 21.56_ 45.63 0 ., 0 0 _ 0 ..,. . ._ 0 0_ 0._ _ 0
P 12__ C-Osw 0.091 _ - 2.55, 1.28 140 140 357 _ 180 0 0 0 0.
C_ 16X19-0md- 0.408 - 1.59 1.49 148 148 235 220 234 234 371 348
F _ __ 22A-tpl_ _. 0.989 - 27.69 0.00 148 _ 9 249 0 ___ 234 9 _ 249 0
6 c)AED excursion -59 -211
Envelope loss/gain 1348 754 1410 805
12 a) Infiltration 160 43 160 43
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 2000
Subtotal(lines 6 to 13) 1507 797 1571 2847
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 1507 797 1571 2847
151 Duct loads 0% 0% 0 0 0% 0% 0 0
Total room load 1507 797 1571 2847
Air required(cfm) 62 37 65 132
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsofY 2017-Aug-10 11:15:22
Right-Suite®Universal 2017 17.0.14 RSU08101 Page 5
..Documents\TULIP 111 MODEL-4735 SELVITZ ROAD.rup Calc=MJ8 Front Door faces: N
-�-wrightsoft° Right-J®Worksheet Job:
Entire House Date:
By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@,AOL.COM
1 Room name DINING MASTER BEDROOM
2 Exposed wall 11.0 ft 49.0 ft
3 Room height 10.0 ft heat/cool 10.0 ft heat/cool
4 Room dimensions 11.0 x 18.0 ft 19.0 x 19.0 ft
5 Room area 198.0 ft2 361.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number (Btuh/ft2--°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A-4ocs 0.143 n 4.00 2.55 110 49 195 124 190 145 582 370
1A-clom 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
1A-clom 1.270 n 35.56 34.77 0 0 0 0 22 0 784 767
1A-c1om 1.270 n 35.56 34.77 0 0 0 0 23 0 803 785
11 1A-c1omd 1.270 n 35.56 34.77 61 0 2176 2128 0 0 0 0
4A5-2om _ 0.770 n 21.56 19.31 0 0 0 0- 0 0, 0 _ .. 0
13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 110 92 370 235
10A-m 1.670 a 46.76 53.19 0 0 0 0 18 0 821 934
IA-c1om 1.270 a 35.56 84.36 0 0 0 0 0 0 0 0
IA-c1om 1.270 a 35.56__ 87.90 _ __ 0 0 -_ ._ 0 0 0 _ _ 0 0 _ _ 0
W 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 0 6 0 0
1A-c1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
IA-c1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
1A-c1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
11DO _ . ._ 0.390_.s. 10.92 11.31 0 .. __ 0 0 0 0 0 0 ._. ._ 0
13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 190 190 761 484
IA-c1orn 1.270 w 35.56 83.01 0 0 0 0 0 0 0 0
4A5.2om 0.770 w 21.56 45.52 0 0 0 0 0 0 0 0
4A5-2om 0.770 w 21,56 45.63 0 0 0 0 0 0_ 0 _ 0
P 12C-0sw_.. -
0.091 _- 2.55 1.28 _ . _ 0 _ 0 . .. _ 0 _ -_ 0 _ _ 0 _ - 0 - 0 __ _._ .0
C 16X19-0md _ 0.408 - 1.59 1.49 198 198 314 294 _ 361 361 572 __ 536
F _ 22A-tpl ___ 0.989 -_ 27.69 0.00. 198 11 305 0 361 49 1357 0
6 c)AED excursion -179 -316
Envelope loss/gain 2990 2367 6051 3796
12 a) Infiltration 196 52 873 234
b) Room ventilation 0 0 0 0
13 Intemal gains: Occupants @ 230 0 0 1 230
Appliances/other 0 0
Subtotal(lines 6 to 13) 3186 2420 6923 4259
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 3186 2420 6923 4259
15 Duct loads 0% 0% 0 0 0% 0% 0 0
Total room load 3186 2112 6923 4259
Air required(cfm) 132 112 286 198
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
"FIF wrightsoft- 2017-Aug-I 11:15:22
Right-Suite®Universal 2017 17.0.14 RSU08101 ACC` ...Documents\TULIP 111 MODEL-4735 SELVITZ ROAD.rup Calc=MJ8 Front Door faces: N Page 6
- wrightsoft° Right-J®Worksheet Job:
Entire House Date:
By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@/10L.COM
1 Room name WIC MASTER BATH
2 Exposed wall 0 ft 14.0 ft
3 Room height 8.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 6.0 x 5.0 ft 1.0 x 125.0 ft
5 Room area 30.0 ft' 125.0 ft2
Ty Construction U-value Or HTM Area (W) Load Area (ftl Load
number (Btuh/ft?°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A-flocs 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0
1A-ciom 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
1Aclom 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
IA-c1om 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
11 IA-ciomd 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
4A5-2om__ _____ 0.770 n. - 21.56 19.31 0 _ 0 0 _0 0 0 ._. _ 0 _ _ 0
13A-m 1.670 a 4.76 2.19 0 0 0 0 0 0 0 0
10A-m 1.670 a 46.76 53.19 0 0 0 0 0 0 0 0
1A-c1om 1.270 a 35.56 84.36 0 0 0 0 0 0 0 0
1A-c1om - - 1.270 e. - 35.56 .._ 87.90 _. _. 0 0 _ -0.- 0.,- 0 - 0 - 0 . .- 0
W 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0
1Aclom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
1A-c1om 1.270 s 35.56 34.77 0 0 0 0 0 0, 0 0
1A-clom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
- 11D0-_- .-s__ _ _ 0.390 s 10.92 _ 11.31 _ __ _0 0 ._._ __ 0 0__ .0 0 __ _.0 0
13A-4ots 0.143 w 4.00 2.55 0 0 0 0 112 101 403 256
1A-c1om 1.270 w 35.56 83.01 0 0 0 0 11 2 400 934
4A5-2om 0.770 w 21.56 45.52 0 0 0 0 0 0 0 0
4A5-2om 0.770 w- _ 21.56 45.63 0 0 0 0 _ _ 0- 0 ___ 0 0
P. - 120-0sw 0.091 - 2.55 _1.28 0 0 0 _ _ 0 80 80_ 204 163
C 16X19-0md 0.408 - 1.59 1.49 30 _ 30 48 45 125 125 198 186
F 22A-tpl- _ _. __ _ __ . - 0.989_-- _ 27.69 ___ 0.00 30 0 _ 0_ _ _ -0 125 _ _ 14 388 0
6 c)AED excursion -3 384
Envelope loss/gain 48 42 1593 1863
12 a) Infiltration 0 0 200 53
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 48 42 1793 1916
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 47 26
14 Subtotal 48 421 1839 1942
15 Duct loads 0% 0% 0 0 0% 0% 0 0
Total room load 48 42 --r1839 1942
Air required(cfm) 2 2 76 90
Calculations approved bV ACCA to meet all requirements of Manual J 8th Ed.
wrigf�tsoft' 2017-Aug-10 11:15:22
Id Right-Suite®Universal 2017 17.0.14 RSU08101 Page 7
'CC` ...Documents\TULIP 111 MODEL-4735 SELVITZ ROAD.rup Calc=MJ8 Front Door faces: N
+wrightsoft° Right-J®Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By:
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fare 772-466-6796 Email:QUICKCALCS@,AOL.COM
1 Room name LAUNDRY A/C
2 Exposed wall 0 ft 0 ft
3 Room height 8.0 ft heat/cool 9.4 ft heat/cool
4 Room dimensions 1.0 x 61.0 ft 5.0 x 4.0 ft
5 Room area 61.0 ftz 20.0 ft'
Ty Construction U-value Or HTM Area (ft� Load Area (ft� Load
number (Btuh/ft2-°F) (Btuh/t� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A-4ocs 0.143 n 4.00 2.55 0 0 0 0 _ _ 0 0 0 0
1A-clom 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
IA-c1om 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
1A-c1om 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
11 IA-c1omd 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
4A5-2om-_ __ 0.770 .n 21.56 _19.31 0 0 _ 0 0 - 0. - _ 0 0. _-.0
0
13A-4ocs 1.670 a 4.76 3.19 0 0 0 0 0 0 0 0
10A-m 1.670 a 46.76 53.19 0 0 0 0 0 0 0 0
1A-c1om 1.270 a 35.56 84.36 0 0 0 0 0 0 0 0
1A-c1om-_ - 1.270 a 35.56 _ 87.90 ,_0 _ 0 0 0 _. 0 0 _ _ _ _ _ _- 0 0
13A-flocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0
1A-c1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
IA-clom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
1A-clom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
11DO _ _____ . 0.390 _ s 10.92 ._ 11.31 0.. 0 _ _ 0 0 _ 0 0 __ _ .0 _ __ __0
VVV���lll 13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0
1A-clom 1.270 w 35.56 83.01 0 0 0 0 0 0 0 0
4A5-2om 0.770 w 21.56 45.52 0 0 0 0 0 0 0 0
4A5-2om 0.770, w 21.56_ 45.63 _ _ -__-0- - 0 _-_0 _ 0_ _ 0 0 _ 0 0
P_ _- 12C-0sw 0.091. = 2.55 _ 1.28 32 -_ . . 32 ._._ .82 41 __ 47 47, _ 120 60
C. 16X19-0md--- 0.408 - 1.59 1.49 61 61 97 _ 91 20 20 32 _30
F__ _ 22A-tpl.. 0.989 _- 27.69..- 0.00 61 0- _-0 0 20 -0 0 _ 0
6 c)AED excursion -9 -6
Envelope loss/gain 178 123 151 84
12 a) Infiltration 0 0 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 178 123 151 84
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 105 58 -151 -84
14 Subtotal 283 181 0 0
15 Duct loads 0% 0% 0 0 0% 0% 0 0
Total room load 283 181 1 1 0 0
Air required(cfm) 12 8 0 0
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
w..ightsoft' 2017-Aug-10 11:15:22
Right-Suite®Universal 2017 17.0.14 RSU08101 Page 8
..Documents\TULIP 111 MODEL-4735 SELVITZ ROAD.rup Calc=MJ8 Front Door faces: N
-�-wrightsoft, Right-M Worksheet Job:
Entire House Date:
By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@,AOL.COM
1 Room name SUITE#2 BATH#3
2 Exposed wall 36.0 ft 16.0 ft
3 Room height 9.4 ft heat/cool 9.4 ft heat/cool
4 Room dimensions 19.0 x 18.0 It 10.0 x 6.0 ft
5 Room area 342.0 ft' 60.0 ft'
Ty Construction U-value Or HTM Area ffl Load Area (ft� Load
number (Btuh/ft�°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A-4ocs 0.143 n 4.00 255 0 0 0 0 94 87 349 222
1A-clom 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
1A-clom 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
IA-clom 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
11 IA-c1omd 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
4A5-2om_ __ _ 0.770 n _ 21.56 _ 19.31 _ ----0 0 0_._ _ 0 7 0 149 134
N13A-4ocs 0.143 a 4.00 2.M 169 169 677 431 56 56 226 144
10A-m 1.670 a 46.76 53.19 0 0 0 0 0 0 0 0
IA-clom 1.270 a 35.56 84.36 0 0 0 0 0 0 0 0
1A-clom _ „ _ _ ,. _ 1,270 e- 35.56._ 87.90 0 0 0 _ _ 0 0 0 0 0
W 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0
1A-clom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
1A-clom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
IA-c1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
11D0. _ .__ ____ 0.390 s 10.92_ _11.31 0 _ 0 _ 0 0 0 .0 _ _ 0 0
jj� 13A-4ocs 0.143 w 4.00 2.55 169 127 510 324 0 0 0 0
IA-c1om 1.270 w 35.56 83.01 0 0 0 0 0 0 0 0
4A5-2om 0.770 w 21.56 45.52 23 1 487 1028 0 0 0 0
4A5-2om 0.770 w 21.56 45.63 19 1 _ _ 415 879 0 0 0 0
P_. 12C-Osw _ _ 0.091 __.2.M _ 1.28 0 . - 0 - .0 _ . 0 _ _0 - -
C 16X190md 0.408 - 1.59 1.49 342 342 542 508 60 60 95 89
F _. 22A-tpl, _- 0.989 - 27.69 , 0.00 342 36 997 _ 0 60 16 443 0
6 c)AED excursion 596 -46
Envelope loss/gain 3629 3766 1262 543
12 a) Infiltration 603 161 268 72
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 4232 3928 1530 614
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 4232 3928 1530 614
15 Ductloads 0% 0% 0 0 0% 0% 0 0
Total room load 4232 3928 1 1 1530 614
Air required(cfm) 175 183 63 29
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsoft� 2017-Aug-10 11:16:22
Right-Suite®Universal 2017 17.0.14 RSUD8101 Page 9
'CC�` ...Documents\TULIP 111 MODEL-4735 SELVITZ ROAD.rup Calc=MJ8 Front Door faces: N
- wrightsoft° Right-J®Worksheet Job:
Entire House Date:
By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name CABANA WIC 2
2 Exposed wall 15.0 ft 0 ft
3 Room height 9.4 ft heat/cool 9.4 ft heat/cool
4 Room dimensions 9.0 x 6.0 ft 6.0 x 5.0 ft
5 Room area 54.0 ft2 30.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number (Btuh/ft2--°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A-4ocs , 0.143 n 4.00 2.55 85 - .- 78 311 198- 0 __. . 0 0 0
1A-clom` 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
1Aclom 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
11J11Aclom 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
1Aclomd 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
_ .4A5-2om . __ 0.77Q _n _ 2,156 19.31_ _ 7- ----- 0 WGL 134 _A _ ,__ 's._.0 __- O _ _. _1
1OA-flocs 1.670 a 4.76 3.19 0 0 0 0 0 0 0 0
10A-m 1.670 a 46.76 53.19 0 0 0 0 0 0 0 0
1A-clom 1.270 a 35.56 84.36 0 0 0 0 0 0 0 0
- 1A_clom.-.., - --- -1.270 e_ -35.56-_ 87.90 . _ 0 -- 0 0 - -0- 0 - 0- - 0 _.0
W --13A floc§ 0.143 s 4.00 2-55 __0 0 0 6 0 0 0 ,. 0
1A-clom ., 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
1A-clom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
1A-c1om 1.270 s 35.56 34.77 0 0 0 0. ,' 0 0 0 0
11DO,,,-a ___ __ .. -0.390 _s ____.10.92 . _11.31 .__ _0.-.__-_ ." 0.., _.-_-_ _0 __ 0 -=0 _. __- .0 0 _ 0,
VVV���✓✓✓ 13A40cs 0.143 w 4.00 2.55 56 34 135 86 0 0 0 0
1A-clom 1.270 w 35.56 83.01 0 0 0 0 0 0 0 0
4A5-2om 0.770 w 21.56 45.52 23 1 487 1028 0 0 0 0
4A5-2om__,__._ 0 0.7
70_w 21._ 56 45.63 _ _ 0 0._ _ _ _0 _ -0 __ _Q_----_0 _ 0
_ _ ,_- _ _ _ __- --_-
255 1,28 _0_ _ - ._0 _..-- _0 ---. _0 _.---_0 -�� _`..0 _ __..0 �.,..�:-0
C 16X19-Omd 0.408 - 1.59 1.49 54 54 86 80 30 30 48 45
F. 22P tpl-- - -0.989 _27.69 0 00 54- _15 _ 415• 0....-_._ 30_ _ ",_0.- - -- 0 ,_ Q
6 c)AED excursion 309 -3
Envelope loss/gain 1584 1835 48 42
12 a) Infiltration 251 67 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 1835 1902 48 42
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 1835 1902 48 42
15 Duct loads 0% 0% 0 0 0% 0% 0 0
Total room load T-T1835 1902 48 42
Air required(cfm) 761 88 1 1 2 2
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
- - wrigtrtt9oft` 2017-Aug-10 11:15:22
Right-Suite®Universal 2017 17.0.14 RSU08101 Page 10
'CC$` ...Documents\TULIP 111 MODEL-4735 SELVITZ ROAD.rup Calc=MJ8 Front Door faces: N
- -wrightsoft° Right-M Worksheet Job:
Entire House Date:
By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@,AOL.COM
1 Room name HALL BAR
2 Exposed wall 9.0 ft
• 3 Room height 9.4 It heat/cool
4 Room dimensions 4.0 x 9.0 ft
5 Room area 36.0 IV
Ty Construction U-value Or HTM Area (ftj Load Area Load
number (Btuh/ftZ-°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A flocs- - - - ..-0.143 n ..4.00 2.55 - - 0... ....._._6. . _0 -
1A-clom 1,270 n 35.56 34.77 0 0 0 0 y
1Aclom 1,270 n 35.56 34.77 0 0 0 0
1Aclon 1.270 n .35.56 34.77 0 0 0 0
11 IA-clomd 1.270 n 35.56 34.77 0 0 0 0
-- 4A5_2om._.._ ---- _-_0.770.-n- 21.50,_ .19.31 0 _0
VV��JJ 13A-flocs 0.143 a 4.00 2.55 0 0 0 0 _
I -G 10A-m 1.670 a 46.76 53.19 0 0 0 0
l��G 1Aclom 1.270 a 35.56 84.36 0 0 0 0
1A-clom 1.270__e_ 35.56 87.90 0 0 0 0
13A-40cs 0.143 s 4.00 2.55 0_ 0 - 0 - --0
1A-clom 1'.270 s 35.56 34.77 0 0 0 0
1A-clom 1:.270 s 35.56 34.77 0 0 0 0
1Aclom 1.270 s 35.56 34.77 0 0 0 0 -
11D0-...:__ ._ __-_- _- w.__0.390__s_ _10.92 _.-11.31 ___._ _-0 -_-.:-- _.0.. __..___. 0 -____. _0__
N13A-4ocs 0.143 w 4.00 2.55 85 85 339 215 -
1Aclom 1.270 w 35.56 83.01 0 0 0 0
4A5-2om 0.770 w 21.56 45.52 0 0 0 0
4A5-2om __,_0.770 w 21.56 45.63 0 0 0 -
P U2 _:qsw __ _..._ - - - -
. __... 0.091 _ -_ ,265 _r1.28 ..TO ___.-----0 _.__ _0 _ 0__,__.._. ,
C 16X19-0md 0.408 - 1.59 1.49 36 36 57
E _0.989 -_-, _ 27,69,_ 0.00__.__._.35 _. . 9 _.._ _.249
--- -- --.,._.
6 c)AED excursion -21
Envelope loss/gain 645 247
12 a) Infiltration 151 40
b) Room ventilation 0 0
13 Internal gains: Occupants @ 230 0 0
Appliances/other 0
Subtotal(lines 6 to 13) 796 288
Less external load 0 0
Less transfer 0 0
Redistribution 0 0
14 Subtotal 796 288
15 Duct loads 0% 0% 0 0
Total room load 288
Air required(cfm) F3973 13
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
_ - wr7gFtttsoft" 2017-Aug-10 11:15:22
Right-Suite®Universal 2017 17.0.14 RSU08101 Page 11
'CC` ...Documents\TULIP 111 MODEL-4735 SELVITZ ROAD.rup Calc=MJ8 Front Door faces: N
-�- wrightsoft® Duct System Summary Dab
Entire House By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCWOL.COM
Project • •
For: TULIP MODEL III
4735 SELVITZ ROAD, FT. PIERCE, FL 34981
Heating Cooling
External static pressure 0.50 in H2O 0.50 in H2O
Pressure losses 0 in H2O 0 in H2O
Available static pressure 0.50 in H2O 0.50 in H2O
Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O
Lowest friction rate 0.216 in/100ft 0.216 in/100ft
Actual air flow 1550 cfm 1550 cfm
Total effective length (TEL) 231 ft
• • Branch Detail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv
Name (Btuh) (cfm) (cfm) FIR (in) (in) Matl Ln (ft) Ln (ft) Trunk
BATH#3 h 1530 63 29 0.217 4.0 Ox0 VIFx 75.5 155.0 st4
BATH#4 c 957 35 44 0.282 4.0 Ox0 VIFx 42.5 135.0 st3
BATH#5 c 957 35 44 0.245 4.0 Ox0 VIFx 48.8 155.0 st5
BEDROOM 3 c 3649 92 170 0.265 7.0 Ox0 VIFx 53.5 135.0 st3
BEDROOM 4 c 3717 102 173 0.287 7.0 Ox0 VIFx 39.0 135.0 st3
BEDROOM 5 h 3913 162 106 0.240 7.0 Ox0 VIFx 53.6 155.0 st5
CABANA c 1902 76 88 0.216 4.0 Ox0 VIFx 76.1 155.0 st4
DINING h 3186 132 112 0.369 7.0 Ox0 VIFx 20.6 115.0 st2
FOYER h 1507 62 37 0.356 6.0 Ox0 VIFx 25.6 115.0 st2
HALL h 118 5 5 0.221 4.0 Ox0 VIFx 71.6 155.0 st4
HALL BAR h 288 33 13 . 0 0 Ox0 VIFx 0 0
KITCHEN c 2847 65 132 0.288 7.0 Ox0 VIFx 38.5 135.0 st3
LAUNDRY h 283 12 8 0.507 4.0 Ox 0 VIFx 3.6 95.0
LIVING ROOM h 3259 135 113 0.357 7.0 Ox0 VIFx 24.9 115.0 st2
MASTER BATH c 1942 76 90 0.370 6.0 Ox 0 VIFx 20.3 115.0 st1
MASTER BEDROOM h 3462 143 99 0.389 7.0 Ox0 VIFx 13.6 115.0 st1
MASTER BEDROOM-A h 3462 143 99 0.380 7.0 Ox0 VIFx 16.7 115.0 st1
SUITE#2 c 1964 88 91 0.230 7.0 Ox0 VIFx 62.7 155.0 st4
SUITE#2-A c 1964 88 91 0.232 7.0 Ox0 VIFx 60.4 155.0 st4
WIC c 48 2 2 0.387 4.0 Ox0 VIFx 14.2 115.0 st1
WIC 2 c 48 2 2 0.389 4.0 Ox0 VIFx 13.6 115.0 st1
wri htsoft® 2017-Aug-1011:15:24
ti 9 Right-SURe®Universal 2017 17.0.14 RSU08101 Page 1
ACC& ...Documents\TULIP 111 MODEL4735 SELVITZ ROAD.rup Calc=MJ8 Front Door faces: N
SupplyDetail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk
st4 Peak AVF 319 304 0.216 406 12.0 0 x 0 VinlFlx st3
st5 Peak AVF 197 151 0.240 564 8.0 0 x 0 VinlFlx st3
st3 Peak AVF 810 974 0.216 911 14.0 0 x 0 VinlFlx st2
st2 Peak AVF 1139 1236 0.216 885 16.0 0 x 0 VinlFlx
st1 Peak AVF 367 292 0.370 467 12.0 0 x 0 VinlFlx
TableReturn Branch Detail
Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Mat[ Trunk
rb1 Ox 0 1550 1550 0 0 0 0 Ox 0 VIFx
ti wri htSoft' 2017-Aug-10 11:15:24
ti 9 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 2
ACC' ...Documents\TULIP 111 MODEL-4735 SELVITZ ROAD.rup Calc=MJ8 Front Door faces: N
03
_ -
File, Co
0RM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: TULIP 111 MODEL 4735 SELVITZ ROAD Builder Name: JC&Sons Home Builder, Inc.
Street: 4735 SELVITZ ROAD Permit Office: ST.LUCIE COUNTY
City,State,Zip: PORT ST.LUCIE, FL, Permit Number:1705-0035
Owner: Jurisdiction:
Design Location: FL,Fort Pierce County:: ST.LUCIE COUNTY(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(2531.7 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Ext Insul, Exterior R=4.1 2351.70 ft2
b.Frame-Wood, Exterior R=11.0 180.00 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 5 d.N/A R= ft2
5. Is this a worst case? No 10.Ceiling Types (2783.0 sqft.) Insulation Area a. Roof Deck(Unvented) R=20.0 2783.00 ft2
6. Conditioned floor area above grade(ft2) 2783 b. N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(390.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 325
a. U-Factor: Sgl, U=0.53 281.73 ft2
SHGC: SHGC=0.24
b. U-Factor: Sgl, U=0.55 60.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.25 a.Central Unit � r 5 E 16.00
C. U-Factor: Sgl, U=0.55 48.26 ft2 , G F,a ; P
_ Y..r. e�, air '-! -}
SHGC: SHGC 0.22 13.Heatinh sii ��. ;� � A.A tfilftr F62 ,f 1piency
d. U-Factor: N/A ft2 a .0IetnStnplP:1.00
SHGC:
Area Weighted Average Overhang Depth: 3.357 ft. `'1
Area Weighted Average SHGC: 0.239 14. of aesstem
aap
1 allons
8. Floor Types (2783.2 sqft.) Insulation Area
r i 5a+yid gs y
'4 EE.1,0.950
a.Slab-On-Grade Edge Insulation R=0.0 2783.20 ft2 b. ohs'�iidtFi features
b.N/A R= ft2 None
c. N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.140 Total Proposed Modified Loads: 84.42 PASS
Total Baseline Loads: 92.13
I hereby certify that the plans and specifications covered by Review of the plans and O�gHE Srq?�
this calculation are in compliance with the,Florida Energy specifications covered by this1+
Code. calculation indicates compliance
with the Florida Energy Code. ti mr,r.,:.'"-. •;: ,;.,,� ,� O
PREPA D Y: Before construction is completed
DATE: this building will be inspected for
compliance with Section 553.908
Florida Statutes.
I herebycertify that this in des' ed i `t
fy m ph n
with the Florida Ene y
OWNER/AGENT: BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
8/17/2017 10:21 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6
II
FOR R405-2014
PROJECT
Title: TULIP 111 MODEL 4735 SEL Bedrooms: 5 Address Type: Street Address
Building Type: User Conditioned Area: 2783 Lot#
Owner: Total Stories: 1 Block/SubDivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: JC&Sons Home Builder, Inc Rotate Angle: 0 Street: 4735 SELVITZ ROAD
Permit Office: ST.LUCIE COUNTY Cross Ventilation: No, County: ST.LUCIE COUNTY
Jurisdiction: Whole House Fan: No. City,State,Zip: PORT ST.LUCIE,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment:
CLIMATE
IECC Design Temp Int Design Temp Heating Design Daily Temp
v Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
1 Entire House 2783 25470.8
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 BEDROOM 2 180 1440 No 1 1 1 Yes Yes Yes
2 BATH 2 72 576 No 0 1 Yes Yes Yes
3 BEDROOM 3 180 1440 No 1 1 1 Yes Yes Yes
4 BATH 3 72 576 No 0 1 Yes Yes Yes
5 BEDROOM 4 213 1704 No 1 1 1 Yes Yes Yes
6 HALL 63 504 No 0 1 No Yes Yes
7 LIVING ROOM 304 3040 No 1 1 Yes Yes Yes
8 FOYER 148 1480 No 0 1 Yes Yes Yes
9 KITCHEN 234 2340 Yes 0 1 Yes Yes Yes
10 DINING 198 1980 No 0 1 Yes Yes Yes
11 MASTER BEDROO 361 3610 No 1 1 1 Yes Yes Yes
12 WIC 60 480 No 0 1 No Yes Yes
13 MASTER BATH 125 1000 No 0 1 Yes Yes Yes
14 LAUNDRY 61 488 No 0 1 No Yes Yes
15 A/C 20 188 No 0 1 No Yes Yes
16 SUITE#2 378 3553.2 No 0 1 1 Yes Yes Yes
17 BATH#3 60 564 No 0 1 Yes Yes Yes
18 CABANA 54 507.6 No 0 1 Yes Yes Yes
8/17/2017 10:21 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6
FORM R405-2014 •
.� FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft2 ____ 0 1 0
2 Slab-On-Grade Edge Insulatio BATH 2 6 ft 0 72 ft2 ____ 0 1 0
3 Slab-On-Grade Edge Insulatio BEDROOM 3 15 ft 0 180 ft2 ____ 0 1 0
4 Slab-On-Grade Edge Insulatio BATH 3 6 ft 0 72 ft2 0 1 0
5 Slab-On-Grade Edge Insulatio BEDROOM 4 34 ft 0 213 ft2 ____ 0 1 0
6 Slab-On-Grade Edge Insulatio HALL 1 ft 0 63 ft2 ____ 0 1 0
7 Slab-On-Grade Edge Insulatio LIVING ROOM 16 ft 0 304 ft2 _—_ 0 1 0
8 Slab-On-Grade Edge Insulatio FOYER 9 ft 0 148 ft2 ____ 0 1 0
9 Slab-On-Grade Edge Insulatio KITCHEN 9 ft 0 234 ft2 ____ 0 1 0
10SIab-On-Grade Edge Insulatio DINING 11 ft 0 198 ft2 ____ 0 1 0
11Slab-On-Grade Edge Insulatio MASTER BEDRO 49 ft 0 361 ft2 ____ 0 1 0
12SIab-On-Grade Edge Insulatio WIC 1 ft 0 60 ft2 ____ 0 1 0
13SIab-On-Grade Edge Insulatio MASTER BATH 14 ft 0 125 ft2 0 1 0
14SIab-On-Grade Edge Insulatio LAUNDRY 1 ft 0 61 ft2 ____ 0 1 0
15Slab-On-Grade Edge Insulatio A/C 1 ft 0 20 ft2 ____ 0 1 0
16SIab-On-Grade Edge Insulatio SUITE#2 45 ft 0 378.2 ft2 ____ 0 1 0
17SIab-On-Grade Edge Insulatio BATH#3 16 ft 0 60 ft2 ____ 0 1 0
18Slab-On-Grade Edge Insulatio CABANA 15 ft 0 54 ft2 0 1 0
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 2933 ft2 0 ft2 Medium 0.6 No 0.9 No 20 18.4
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Unvented 0 2783 ft2 N N
8/17/2017 10:21 AM EnergyGauge@)USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 6
I '
FORM R405-2014
r CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Unvented) BEDROOM 2 20 Blown 180 ft2 0.1 Wood
2 Under Attic(Unvented) BATH 2 20 Blown 72 ft2 0.1 Wood
3 Under Attic(Unvented) BEDROOM 3 20 Blown 180 ft2 0.1 Wood
4 Under Attic(Unvented) BATH 3 20 Blown 72 ft2 0.1 Wood
5 Under Attic(Unvented) BEDROOM 4 20 Blown 213 ft2 0.1 Wood
6 Under Attic(Unvented) HALL 20 Blown 63 ft2 0.1 Wood
7 Under Attic(Unvented) LIVING ROOM 20 Blown 304 ftz 0.1 Wood
8 Under Attic(Unvented) FOYER 20 Blown 148 ft2 0.1 Wood
9 Under Attic(Unvented) KITCHEN 20 Blown 234 ft2 0.1 Wood
10 Under Attic(Unvented) DINING 20 Blown 198 ft2 0.1 Wood
11 Under Attic(Unvented) MASTER BEDRO 20 Blown 361 ft2 0.1 Wood
12 Under Attic(Unvented) WIC 20 Blown 60 ft2 0.1 Wood
13 Under Attic(Unvented) MASTER BATH 20 Blown 125 ft2 0.1 Wood
14 Under Attic(Unvented) LAUNDRY 20 Blown 61 ft2 0.1 Wood
15 Under Attic(Unvented) A/C 20 Blown 20 ft2 0.1 Wood
16 Under Attic(Unvented) SUITE#2 20 Blown 378 ft2 0.1 Wood
17 Under Attic(Unvented) BATH#3 20 Blown 60 ft2 0.1 Wood
18 Under Attic(Unvented) CABANA 20 Blown 54 ft2 0.1 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
_ 1 E Exterior Concrete Block-Ext InOEDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.6 0
2 E Exterior Concrete Block-Ext Insul BATH 2 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0
3 E Exterior Concrete Block-Ext InfiffDROOM 3 4.1 15 0 8 0 120.0 ft2 0 0 0.6 0
4 E Exterior Concrete Block-Ext Insul BATH 3 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0
5 E Exterior Concrete Block-Ext InQEDROOM 4 4.1 13 0 8 0 104.0 ft2 0 0 0.6 0
_ 6 S Exterior Concrete Block-Ext InfiffDROOM 4 4.1 15 0 8 0 120.0 ft2 0 0 0.6 0
7 W Exterior Concrete Block-Ext IndIffDROOM 4 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0
_ 8 S Exterior Concrete Block-Ext InddVING ROO 4.1 16 0 10 0 160.0 ft2 0 0 0.6 0
9 S Exterior Concrete Block-Ext Insul FOYER 4.1 8 0 10 0 80.0 ft2 0 0 0.6 0
10 W Exterior Concrete Block-Ext Insul FOYER 4.1 1 0 10 0 10.0 ft2 0 0 0.6 0
11 N Exterior Concrete Block-Ext InsuKITCHEN 4.1 9 0 10 0 90.0 ft2 0 0 0.6 0
12 N Exterior Concrete Block-Ext Insul DINING 4.1 11 0 10 0 110.0 ft2 0 0 0.6 0
13 N Exterior Concrete Block-Ext InsMASTER BE 4.1 19 0 10 0 190.0 ft2 0 0 0.6 0
14 E Exterior Concrete Block-Ext InEMASTER BE 4.1 11 0 10 0 110.0 ft2 0 0 0.6 0
15 W Exterior Concrete Block-Ext InsMASTER BE 4.1 19 0 10 0 190.0 ft2 0 0 0.6 0
_16 W Exterior Concrete Block-Ext InsMASTER BA 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0
17 E Exterior Concrete Block-Ext InsuSUITE#2 4.1 18 0 9 5 169.5 ft2 0 0 0.6 0
18 W Exterior Concrete Block-Ext Insu6UITE#2 4.1 27 0 9 5 254.3 ft2 0 0 0.6 0
19 N Exterior Concrete Block-Ext InsuBATH#3 4.1 10 0 9 5 94.2 ft2 0 0 0.6 0
_20 E Exterior Concrete Block-Ext InsuBATH#3 4.1 6 0 9 5 56.5 ft2 0 0 0.6 0
_21 N Exterior Concrete Block-Ext InsuCABANA 4.1 9 0 9 5 84.8 ft2 0 0 0.6 0
_22 W Exterior Concrete Block-Ext InsuCABANA 4.1 6 0 9 5 56.5 ft2 0 0 0.6 0
8/17/2017 10:21 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6
i
FORM R405-2014 •
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
23 N Exterior Frame-Wood CABANA 11 20 9 180.0 ft2 0.23 0.6 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 S Insulated FOYER None .39 3 7 21 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 E 1 Metal Low-E Single Yes 0.53 0.24 33.8 ft' 1 ft 4 in 1 ft 4 in None None
2 E 2 Metal Low-E Single Yes 0.53 0.24 9.0 ft2 1 ft 4 in 1 ft 4 in None None
3 E 3 Metal Low-E Single Yes 0.53 0.24 33.8 ft2 1 ft 4 in 1 ft 4 in None None
4 E 4 Metal Low-E Single Yes 0.53 0.24 9.0 ft2 1 ft 4 in 1 ft 4 in None None
5 S 6 Metal Low-E Single Yes 0.53 0.24 33.8 ft2 1 ft 4 in 1 ft 4 in None None
6 S 8 Metal Low-E Single Yes 0.53 0.24 22.1 ft2 8 ft 0 in 1 ft 4 in None None
7 S 8 Metal Low-E Single Yes 0.53 0.24 22.7 ft2 8 ft 0 in 1 ft 4 in None None
8 N 11 Metal Low-E Single Yes 0.53 0.24 13.6 ft2 8 ft 0 in 1 ft 4 in None None
9 N 12 Metal Low-E Single Yes 0.55 0.25 60.0 ft2 8 ft 0 in 1 ft 4 in None None
10 N 13 Metal Low-E Single Yes 0.53 0.24 22.2 ft2 1 ft 4 in 1 ft 4 in None None
11 N 13 Metal Low-E Single Yes 0.53 0.24 22.7 ft2 1 ft 4 in 1 ft 4 in None None
12 E 14 Metal Low-E Single Yes 0.55 0.22 17.7 ft2 1 ft 4 in 1 ft 4 in None None
13 W 16 Metal Low-E Single Yes 0.55 0.22 11.3 ft2 1 ft 4 in 1 ft 4 in None None
14 E 17 Metal Low-E Single Yes 0.53 0.24 45.4 ft' 1 ft 4 in 1 ft 4 in None None
15 W 18 Metal Low-E Single Yes 0.55 0.22 19.4 ft2 1 ft 4 in 1 ft 4 in None None
16 N 19 Metal Low-E Single Yes 0.53 0.24 6.9 ft2 1 ft 4 in 1 ft 4 in None None
17 N 21 Metal Low-E Single Yes 0.53 0.24 6.9 ft2 1 ft 4 in 1 ft 4 in None None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 480 ft2 480 ft2 20 ft 9 ft 11
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000407 2971.6 163.14 306.8 .2972 7
8/17/2017 10:21 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6
F RM R405-2014
i' HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Strip Heat None COP:1 34 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER: 16 46.5 kBtu/hr 1395 cfm 0.8 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ftZ
DUCTS
—Supply— —Return— Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 325 ftZ Attic 105 ftZ Default Leakage Garage (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans: [ ] [ ] rj
Jun
Nov Dec
Venting € Jan Feb ki Mar Apr MM:yay rj
Jun ri Jul ri Aug SepL Oct NNov Dec
ov H Dec
Jun ]Jul ]Aug Sep LxJ
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM . 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
8/17/2017 10:21 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 6
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: TULIP 111 MODEL 4735 SELVITZ ROAD Builder Name: JC&Sons Home Builder,Inc.
Street: 4735 SELVITZ ROAD Permit Office: ST.LUCIE COUNTY
City,State,Zip: PORT ST.LUCIE, FL, Permit Number:1705-0035
Owner: Jurisdiction:
Design Location: FL,Fort Pierce
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall not be used as a sealing material.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors The space between window/doorjambs and framing and skylights and
framing shall be sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
airtight, IC rated,and sealed to the drywall.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls,or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
8/17/2017 10:21 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1