Loading...
HomeMy WebLinkAboutRevisions (2) 51 • 1 OFFICE USE ONLY: 2Z DATE FILED: v� d ^ ` PERMIT# 170-5-- 0035 REVISION FEE: RECEIPT# PLANNING&DEVELOPMENT SERVICES BUILDING&CODE REGULATION DIVISION RCEIVCD 2300 VIRGINIA AVENUE FORT PIERCE,FL 34982.5652 (772)462.1553 J U N 0 5 Z018 APPLICATION FOR BUILDING PERMIT REVISION ST. Lucie county, Permitting PROJECT INFORMATION LOCATION/SITE ADDRESS: 7J �ffl))2- ?11 P 2 e L 4 e / DETAILED DESCRIPTION OF PROJECT REVISIONS: CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: ST.LUCIE CO CERT.#: BUSINESS NAME: nSc7►'1 QUALIFIERS N ADDRL : ^ 3 CITY: _ STATE: L ZIP: PHONE(DAYTIME): - - Q 6) FAX: q /y -51j - o3s-s OWNER/BUILDER INFORMATION: NAME: ADDRESS: CITY: STATE: ZIP: PHONE(DAYTIME: FAX: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: S E: ZIP: PHONE(DAYTIME): FAX: K u SLCCC: 9123109 O V R d 06 0/1 AIL COPs�� V,I PAUL WELCH INC. RECEIVED Mechanical * Electrical * Civil Engineering i U N 1 1 2018 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie,FL 34984 ST. Lucie county, Permitting Phone (772) 785 - 9888 Email pwelchinc@aol.com June 11, 2018 Re: Garcia Residence 4735 Selvitz Rd. Fort Pierce,FL Permit#1705-0035 To Whom It May Concern: Please be advised of the revisions to the above referenced project as follows: 1)Revise roofing to be "Exterme Metal Fabricators" 1"Nail Strip (FL#17022.5). a) Attach metal roofing with corrosion resistant Pancake-Head screws#10 x 1" minimum(minimum 3/16"penetration through deck). Fasteners to be in the nailstrip at 6" O.C. every panel. b) Seam adhesive not required. Thank you for your attention to this matter. Submitted by: PA WELCH INC. Paul Welch,P.E. Reg. No 29945 PW:pj RECEIVED EXTERIOR RESEARCH &DESIGN, LLC. J�I r, 20 $ Certificate of Authorization#9503 E�® 353 CHRISTIAN STREET, UNIT#13 ST. Lugin.,Pptanty, Permitting OXFORD,CT 06478 (203) 262-9245 EVALUATION REPORT TRI-BUILT Materials Group,LLC Evaluation Report A42960.10.12-R6 PO Box 70 FL16048-116 Rutherford, NJ 07070 Date of Issuance: 10/25/2012 (800) 516-1485 Revision 6: 09/25/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use.of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6ch Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: TRI-BUILT Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: _ 1 - OF �� Robert J.M. Nieminen, P.E. c�'hj"�r ;�� ` 1` The facsimile seal appearing was authorized by Robert Nieminen, Florida Registration No.59166,Florida DCA ANE1983 P.E.on 09/25/2017.This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Trinity]ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity[ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity[ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. _)0 \\JTRINITYI ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: TRI-BUILT Roof Underlayments, as produced by TRI-BUILT Materials Group, LLC, have demonstrated compliance with the following sections of the 61h Edition(2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/ Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Resistance FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1504.6 Accelerated Weathering ASTM G155 2005 1507.2.4/1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012(04-12) 2012 3. REFERENCES: Entity Examination Reference Date ERD(TST6049) Physical Properties S40540.02.13-1 02/19/2013 ERD(TST6049) Physical Properties S40540.11.13 11/19/2013 ERD(TST6049) Physical Properties S40540.03.14 03/26/2014 ERD(TST6049) Physical Properties S44870.04.14-2 04/02/2014 ERD(TST6049) Physical Properties S44870.04.14-3 04/02/2014 ERD(TST6049) Physical Properties S44870.04.14-1 04/10/2014 ERD(TST6049) Physical Properties S44870.04.14-4 04/10/2014 ERD(TST6049) Physical Properties S43530.02.14-1-R1 05/14/2014 ERD(TST6049) Physical Properties S43530.05.14 05/28/2014 ERD(TST6049) Physical Properties S40540.10.14 10/31/2014 ERD(TST6049) Physical Properties SC7645.02.15 02/13/2015 ERD(TST6049) Accelerated Weathering SC8520.04.15 05/27/2015 ERD(TST6049) Wind Resistance SC14045.05.17-R1 06/07/2017 UL,LLC.(QUA9625) Quality Control Multiple-Listing R16814 12/10/2015 UL,LLC.(QUA9625) Quality Control Service Confirmation Exp.07/18/2020 4. PRODUCT DESCRIPTION: 4.1 Tri-Built Sand-R SA Shingle Underlayment is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment,with a 36-inch sheet width;meets ASTM D1970. 4.2 Tri-Built S/A HT TU Underlayment is a self-adhering, non-woven polyester fabric surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI April 2012. 4.3 Tri-Built Smooth HT S/A Underlayment is a self-adhering, glass-mat reinforced, film-surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity[ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,U.C. Evaluation Report A42960.10.12-R6 Certificate of Authorization#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL16048-R6 TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/25/2017 Page 2 of 6 a . • a -,)o \\JTRINITY�ERD 5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: TABLE It ROOFDCOVER OPTIONS, Underlayment Asphalt Nail-On Tile Foam-On Tile Metal Wood Shakes Slate Shingles &Shingles Tri-Built Sand-R SA Shingle Yes No No No Yes Yes Underlayment Tri-Built S/A HT TU Yes Underlayment Yes Yes See 5.5.1 Yes Yes Yes Tri-Built Smooth HT S/A Yes No No Yes Yes Yes Underlayment 5.5.1 "Foam-On Tile"is limited to use of the following Approved tile adhesives/underlayment combinations. e TABLE 1A ALLOWABLE TILE ADHESIVE/;UNDERIAYMENT COMBINATIONS1' Adhesive Florida Product Approval Underlayments ICP Adhesives Polyset®AH-160 FL6332 Tri-Built S/A HT TU Underlayment Dow TIIeBondT1 FL22525 Tri-Built S/A HT TU Underlayment 5.6 Allowable Substrates: 5.6.1 Direct-Bond to Deck: Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine;ASTM D41 primed structural concrete. While not required over plywood, OSB or Southern Yellow Pine substrates,TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note: TRI-BUILT Materials Group, LLC requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the self-adhering underlayment. 5.6.2 Bond-to-Insulation: Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474,Appendix D or TAS 114,Appendix J. 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. Exterior Research and Design,LLC. Evaluation Report A42960.10.12-R6 Certificate of Authorization#9503 6"'EDITION(2017)FBC NON-HVHZ EVALUATION FL16048-R6 TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/25/2017 Page 3 of 6 TRINITY�ERD 5.6.3 Bond to Mechanically Attached Base Laver: Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ ASTM D226,Type I or II felt. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam-on tile systems (Tri-Built S/A HT TU Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04- 12). 5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems, where the underlayment forms part of the load-path. The following wind uplift limitations apply to direct-deck underlayment systems that are not addressed in FRSA/TRI April 2012(04-12) and are used in foam-on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04-12), Appendix A,Table 1A or FBC 1609 for determination of design wind pressures. #1 Maximum Design Pressure=-45.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)ASTM D41 or RESISTO EXTERIOR PRIMER Underlayment: Tri-Built S/A HTTU Underlayment,self-adhered. #2 Maximum Design Pressure=-67.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Soprema Elastocol 600c Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered. #3 Maximum Design Pressure=-150.0 psf: Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to satisfaction of Authority Having Jurisdiction. Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood projections shall be removed/sanded. Primer: (Optional) RESISTO EXTERIOR PRIMER Underlayment: Tri-Built S/A HT TU Underlayment, self-adhered, shall be thoroughly roll using hand roller and/or weighted roller to ensure there are no voids, and ensure there are no voids/bridging at side and end-laps. #4 Maximum Design Pressure=-60.0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2)spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three, equally spaced rows in the center of the sheet. Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered. Exterior Research and Design,LLC. Evaluation Report A42960.10.12-R6 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL16048-116 TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/25/2017 Page 4 of 6 TOP.,�INITYERD 5.6.4.1 For mechanically attached Base Sheet,the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDl, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. 5.7 Exposure Limitations: Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left exposed for longer than 30-days after installation Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 180-days after installation. 5.8 Tile Slippage Limitations(TAS 103 per FRSA/TRI April 2012(04-12)): When loading roof tiles on the underlayment in direct-deck tile assemblies,the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 2 `TILE SLIPP,AGE;LIMITATiION$FOR"DIRECT DECKTILE INSTALLATIONS Underlayment Tile Profile Staging Method MaximumSlope Flat Max.10-tile stack 6:12 Lugged Max. 10-tile stack 5:12 Max.10-tile stack(bottom 2-tile stack shall be inverted,followed by 8 tiles high 6:12 on slope,as shown below) T 4 $ � �a,>:. ' �`"x \•§`tea�a f 7, � '� � 1��,Y 3 Tri-Built S/A HT TU Underlayment Lugged I ila y'� Exterior Research and Design,LLC. Evaluation Report A42960.10.12-R6 Certificate of Authorization#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL16048-R6 TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/25/2017 Page 5 of 6 TRRINITYIERD 6. INSTALLATION: 6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT Materials Group, LLC published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). 6.3 Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment: 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.3.2 Non-Tile applications: While priming is optional, TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place, peel-off the release film diagonally while holding the membrane tight. Firmly roll, broom or hand-press the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6- inches and staggered not less than 2-ft from vertical seams in the course below, sealed in accordance with TRI-BUILT Materials Group,LLC requirements. When installing at slopes above 8:12, TRI-BUILT Materials Group, LLC recommends back-nailing in the overlap area at the top of the sheet at 12-inch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys,apply the sheet starting at the lowest point and work upward. 6.3.3 Tile Applications(Tri-Built S/A HTTU Underlayment only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For foam-on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012(04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See Table 2 herein, and TRI-BUILT Materials Group, LLC published requirements for tile staging. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Gulfport, MS 9. QUALITY ASSURANCE ENTITY: UL, LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com -END OF EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report A42960.10.12-R6 Certificate of Authorization#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL16048-R6 TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/25/2017 Page 6 of 6 o NO rai RCIS Home i Lop In I User Registration t Hot'Topics i Submit Surcharge i Slats!1 Facts Publications FBC Staff i aCIS Site hap i Links ( Search e- r 6US"":".hrc.. Product Approval ECEIVED(1,,,�,�]1 £ r „rt hnnrnval hllUtt{>Prnnuct or ArpJicninl},S,y;py{jt> s t inpy;�a Application oatoll J U N 0 5 2018 { FL Ir FL17022 R7 Permitting Application Type. Revision ST. Lucie County, Code Version 2017 Application Status Approved Comments 08/18/2017v.date reapply 08/21/17 Archived l l Product Manufacturer Extreme Metal Fabricators,LLC Address/Phone/Email 2160 SW Poma Drive Palm City,FL 34990 (772)872-8034. fivalidation@yahoo.com Authorized Signature Richard McKuhen fivaiidation@yahoo.com Technical Representative Richard McKuhen Address/Phone/Email 2160.SW Poma Drive Palen City,FL 39990 (772)872-8034 richard@emfab.net Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida.Registered.Architect or a Licensed Florida Professional Engineer F. Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed LOCKE BOWDEN the Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Zachary R.Priest,P.E. R11 Validation Checklist-Hardcopy Received Certificate of Independence Fk17022 R7 MI FL 17022.1 S V CRiMn 5r.a01 Referenced Standard and Year(of Standard) Standard YM TAS.125 2003 UL1897 2012 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 08/18/2017 Date Validated 08/25/2017 Date Pending FBC Approval 08/28/2017 Date Approved 10/10/2017 Summary of Products FL# Model,Number or Name Description 17022.1 1-'SV Crimp"(116) 26 Gauge steel,3/8'rib height,24'wide lapped roof panel mechanically attached to 15/32'plywood or Wood Deck with fasteners Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R7 If FL 17022.1 5 V CRiMP ssr.odf Approved for use outside HVHZ:Yes Verified By:Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions.Install the F 17022 R7 AE FL 17022.1 5 V CRIMP ser.ndf assembly In compliance with the installation method listed In Created by Independent Third Party:Yes this report and applicable code sections of FBC.Refer to manufacturer's Installation Instructions. 17022.2 2-"5V Crimp"(116) 0.032"Aluminum;3/8'Rib height,21"wide lapped roof panel,mechanically attached to 15/32"plywood or Wood Deck with exposed fasteners Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R7 Ii Ft-17022.2 5 V CRIMP 0.032 ALUM ssr.odf Approved for use outside HVHZ:Yes Verified By:Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditlons.Install the FI 17022 R7 AE FL 17022 2 5 V CRIMP 0.032 assembly In compliance with the Installation method listed In (µ,UM ssr.odf this report and applicable code sections of FBC,Refer to Created by independent Third Party:Yes manufacturer's Installation instructions. 17022.3 3-'1.5'Mechanical Seam"(115) 1.5'rib height,Ir wide,24 gauge steel,standing seam roof panel mechanically attached to 15/32"plywood or wood deck with clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No Fl 17022 R7 If FL 17022.3 t s MECHANICAL Approved for use outside HVHZ:Yes seam 24na ssr.ndf Impact Resistant:No Verified By:Locke Bowden,P.E.49704 Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes Other:Rarer to evaluation report for conditions and Evaluation Reports limitations of use.Install the assembly In compliance with FI 17022 R7 AE FL 17022.3 14 MECHANICAL the installation method listed In this report and applicable seam 24aa ssr.ndf code sections of FBC.Refer to manufacturer's Installation Created by Independent Third Party:Yes instructions. 17022.4 4-'1.5"Mechanical Seam"(RS) 1.5'rib height,16"wide,0.032"aluminum;standing seam roof panel mechanically attached to 15/32"plywood or Wood Deck with clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No FL170 2 R7 If FL 17022.4 MECHANCCAL SEAM Approved for use outside HVHZ:Yes ALUMINUM ssr.edf. Impact Resistant:No Verified By:Locke Bowden,P.E.49704 Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes Other:Refer to evaluation report for conditions and Evaluation Reports limitations of use.Install the assembly In compliance with El 17022 R7 AE FL 17022.4 MECHANCiAL SEAM the Installation method listed In this report and applicable ALUMINUM ssr.0df code sections of FBC.Refer to manufacturer's Installation Created by Independent Third Party:Yes instru S. 17022.5 5-"1 in.Nall Strip"(R5) 1"rib helght,_,16"wide,26 gauge steel,standing seam roof panel mechanically attached to.15/32"plywood or wood deck with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No y7072 g7 11 F •7677 s . o NAiLSTRIP eegndf Approved for use outside HVHZ:Yes Verified By:Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions and FL17022 R7 AE FL 170 2 5 1.0 NAiLSTRIP ssr.odf limitations of use.Install the assembly In compliance with Created by Independent Third Party:Yes the Installation method listed In this report and applicable code sections of FBC.Refer to manufacturer's installation Instructions. 17022.6 6-"1 in.Nall Strip"(115) 1"rib height,16"wide,0.032"aluminum,standing seam roof panel mechanically attached to attached to 15/32" plywood or Wood Deck with fasteners, Limits of Use Installation instructions Approved for use in HVHZ:No Ff 170.2 R7 Ii FL 17022.6 1.0 NAR_STRi'I_Q. Z Approved for use outside HVHZ:Yes ALUM SSr.Rdf Impact Resistant:No Verified By:Locke Bowden,P.E,49704 Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes Other:Refer to evaluation report for conditions and Evaluation Reports limitations of use.Install the assembly in compliance with EL1Z422_RZ Ae eL 17022.6 t..4_NAILS1[iI'-0..02 the installation method listed In this report and applicable ALUMR ssr.odf Code sections of FBC.Refer to manufacturer's installation Created by Independent Third Party:Yes Instructions. 17022.7 .7-"13 in.Nall Strip°(RS) 1.5"rib height,19"wide,26 gauge steel,standing seam roof panel mechanically attached to 15/32"plywood or wood deck with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022_R7 11 A.17022.7 1.5 N it Strip 26GA ssr.odf Approved for use outside HVHZ:Yes Verified By:Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions and F7022 R7 AE FL.17�LI Q22 7 1.5 Nail Strip 26GA ssr.Q(f limitations of use.Install the assembly in compliance with Created by Independent Third Party:Yes the Installation method listed in this report and applicable code sections of FBC.Refer to manufacturer's installation instructions. 17022.8 8-"EMAX Rib"(R5) 29 gauge steel,lapped roof panel mechanically attached to 15/32"plywood or wood deck with exposed fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No FLt7022 R7 iI FL 177022.8 EMAX Rib 5sr.odf Approved for use outside HVHZ:Yes Verified By,Locke Bowden,P.E.49704 Impact Resistant:No Created by independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions and FI 17022_R7 bF 1776zz,$)MAX Rih esr pdf limitations of use.Install the assembly In compliance with Created by lhdependent.Third Party:Yes the Installation method Ilsted in this report and applicable code sections of F8C.Refer to manufacturer's installation instructions. 17022.9 9 PBR MAX"(RS) 26.gauge steel,lapped roof panel mechanically attached to 15/32"plywood or wood deck with exposed fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No FI i70. R7 it FL 17022.9 POR RiB ssr.odf Approved for use outside HVHZ:Yes Verified By:Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions and EL)7022 R7 AF Ff. 17022.9 PBR RiB ssr pdf limitations of use.Install the assembly In compliance with Created by Independent Third Party:Yes the installation method listed In this report and applicable code sections of FBC.Refer to manufacturer's installation instructions. Bacit Next ' Contact::760i filair Stolle Road,Tallahassee Ft.37399 Phone:850.467-1024 The State of Florida is an AA/Eeo employer,Courinht 2o07.2013 State ofFlorlda.it Privacv statement::Acce5fihnity Statement::.Reran Statement Under Florida law,email addresses are public records.If Vail do norwant your e-mail address released In response to a publieaecotds request,do not send electronic mad to this entity:Instead,.contact the office by phone or by traditional mad.if you have arty questions,please contact 850.487.1395.'Pursuant to Section 455.275 (1),Florida Statutes,ellective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with fne licensee,However email addresses are public recoiv.fir you do not wish to supply a personal address, please provide the Department with an email address which can ba made,avallable to the public.T'o determine if you are a licensee under Chapter 455,F.S.,please chick Hors.• Product Approval Aaop". Credit CA(d Safe;: .N;Rmm� 2160 SW Poma Drive Palm City, FL 34990 7.7272-8034 Compliant with Florida Building Code 2017'(6t" ed.) Compliant with Florida Product Approval Rule#611320-3 Compliant: Keystone Certifications Product: 1" Nailstrip 26GA Steel Roof Panel FBC Sec. 1507.4.2 Yield strength: 50 ksi min.;Attached to min.15/32"plywood or Wood Deck w/0.42 specific gravity-with 16"Coverage (Max.) Rib Height 1" Corrosion Resistant Compliant: FBC Sec. 1507.4.3 Fastener 1: #10 x 1" (min.) Pancake Head Wood Screw to penetrate 3/16" (min.)thru bottom of support. Adhesive/Sealant : Bostik 9151" Chem-Chalk one component, polyurethane adhesive with 3/16"continuous bead application along base of male rib vertical flange at each panel seam. Underlayment: To be compliant with FBC Sec 1507.1.1 Slope: Shall be in compliance with FBC Sec. 1507. Install Details;y Table A _ Allowable Loads ,. METHOD 1 METHOD 2 DESIGN PRESSURE* -86 PSF Main field .97 25 PSF Perimeter FASTENER SPACING .�_-- . .-.._.._._._...-_.._......._...._._..:,.._.. _._ SEAM ADHESIVE Not required 311V continuous bead see details _...._..._._ ... ...__Ksw_.M.x___ - - Reference Data: ARCHITECTURAL TESTING,INC.TST ID#:1527 ( UL 580.06&UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen#1&#2 i{ [EQUIVALENCY.UL1897-04 is equivalent to Test Standard UL1897712. *Design Pressura margin of safety 2:1 Certificate of independence: Locke Bowden,P.E.does not have,not will acquire a financial lVorestAr)ggy,company manufacturing or distributing products under this evaluation. _+�.�`'�C:D Locke Bowden,P report. .E.is not owned,operated,or control!���.y!.(,.].� �ctorer,or distributing products under this q` Y 41 0. +• A71 2 • " seat STATE OF �� r '�prr• t0RIDt.�, ass C�'}��,•+.r••`�C;. .;% Limitations: 1.Underiayment to be compliance with current Florida Building Code(FBC)2017 6°'ad.. 2.Minimum slope to be compliant with Florida Building Code 2017 61h ed.,and per with Manufacturer's installation reference. 3.Products are compliant for State of Florida product approval per Rule 61 G20-3.Compliance Method:1-D 4.Engineering analysis for"project specific approval by local authorities wtjurisdiction is allowed by other registered engineers. 5.Fire classification is not part of this acceptance.Shear diaphragm values are outside this report. 6.Support framing in compliance w/FBC 2017 6"'ed.,Chapter 22 for Steel,Chapter 23 for Wood and Chapter 16 for Structural Loading. 7.This report does not imply warranty,installation,recommended product use outside of this report. FL 17022.5 1.0 Nail Strip(26GA Steel),16"Wide Roof Panel-Details 16" 3/4�" Panel Profile 16"ox. Deck: -15/32"or greater Plywood,or -Wood plank Integral Snap Lock �I For METHOD 2: Apply 3116"Bead Bostik 915TM Sealant Continuous Along Male Rib Vertical Flange -l',`' \L``--' Fastener #10 x 1"Min. per Table"A" Pancake Head Wood Screw (Typical Fastening.Pattern Across Width) FL 17022.5 1.0 Nail Strip(26GA Steel),16"Wide Roof Panel-Details Fastener #10 x 1"Min. per Table"A" Pancake Head Wood Screw V Nail Strip Roof Panel Q" Seam Adhesive Application: Deck: For Method 2 15/32"or greater Plywood,or Apply 3116"Bead Bostik 915Tm Sealant -Wood plank Continuous Along Male Rib Vertical Range (Refer to Table"A") Isometric View