Loading...
HomeMy WebLinkAboutNotice of AcceptanceMIAMI• MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26_Street, Room 208, DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy DAB Door Company, Inc. 12195 NW 981 Avenue Hialeah Gardens, FL 33018 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted. by Miami -Dade County RER-Product Control Section to be used in Miami Dade' County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify; or suspend the use of -such product or material within.their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: hurricane Master® Model 824/811 Steel Sectional Garage Door 16' 2" Wide with Window Lite Option (DP +36.0,.-44.0 PSF) APPROVAL DOCUMENT: Drawing No. 02-21, titled "24 GA. Roll Formed Steel Sectional Garage Door", dated 09/10/2002, with last revision K dated 03/0912015, sheets 1 through 5'of 5, prepared by Al- Farooq Corporation, signed and sealed by Javad Ahmad, P.E., bearing the Miami -Dade County Product Control renewal stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: A permanent label with the manufacturer's name or logo, manufacturing address, model/series number, the positive and negative design pressure rating, indicate impact rated if applicable, installation instruction drawing reference number, approval number (NOA), the applicable test standards, and the statement reading `Miami -Dade County Product Control Approved' is to be located on -the door's side track, bottom angle, or inner surface of a panel. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration'date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this. NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this-NOA. Failure to comply with any section of this NOA shall be cause for termination and removal ofNOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be. done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer -or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA # 14-0814.10 and consists of this page I and evidence pages E-I and E-2, as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrera, P.E. NOA No.15-0304.01 MU4M6DADE COUNTY Expiration Date: July 21, 2020 is Approval Date: April 23, 2015 dQ- jlfi jZd Page 1 DAB Door Company, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. 02-21, titled "24 GA. Roll Formed Steel Sectional Garage Door", dated 09/10/2002, with last revision J dated 11/07/2014, sheets 1 through 5 of 5, prepared by Al- Farooq Corporation, signed and sealed by Javad Ahmad, P.E. B. TESTS "Submitted under NOA # 11-04-14.12" 1. Test Report on Uniform Static Air- Pressure Test, Loading and Forced Entry Test per FBC, TAS 202-94, of "DAB 824 Sectional Residential Garage Door" prepared by Hurricane Engineering & Testing Inc., ReportNo. HETI-07-4200, dated 05/02/2007, signed and sealed by Candido F. Font, P.E. 2. Test Report on Large Missile Impact Test per FBC, TAS 201-94 and Cyclic Wind Pressure Test per FBC, TAS 203-94, of "DAB 824 Sectional Residential Garage Door", prepared by Hurricane Engineering & Testing Inc., Report No. HETI-11-3204, dated 01/20/2011, signed and sealed by Candido F. Font, P.E. 3. Test Report on Tensile Test per ASTM E8-08 of "Sectional Residential Door (skin)", prepared by Hurricane Engineering & Testing Inc, Report No. HETI-114100, dated 01121/2011, signed and sealed by Candido F. Font, P,E. "Submitted under NOA # 05-022& 02" 4. Test Report on Large Missile Impact Test and Cyclic Wind Pressure Test, of "Sectional Residential Door with Windows", prepared by Hurricane Engineering & Testing Inc., Report No. HETI 03-1328, dated 07/15/2003, signed and' sealed by Rafael E. Droz-Seda, P.E. 5. Test Report on Uniform Static Air Pressure Test, of "Sectional Residential Door" prepared by Hurricane Engineering & Testing Inc., Report No. HETI 03-1329, dated 07/15/2003, signed and sealed by Rafael E. Droz-Seda, P.E. 6. Test Report -on Tensile Test per ASTM E-8 of "Sectional Residential Door (skin)", prepared by Hurricane Engineering & Testing Inc, Report No. HETI 03-T078, dated 10/3112003, signed and sealed by Rafael E. Droz-Seda, P.E. "Submitted under NOA # 03-0210.04" 7. Test report on Salt Spray (Corrosion) Test per ASTM B 117 of a painted G-40 steel panels, prepared by Celotex Corporation, Test Report No. 258592, dated 08/17/1998, signed by W. A. Jackson, P.E. C. CALCULATIONS "Submitted under NOA # 14-0814.10" 1. Anchor verification -calculations prepared by Al-Farooq Corporation, dated 09/22/2014 and 07124/2014, signed and sealed by Javad Ahmad, P.E. Carlos M. Utrera, P.E. Product Control Examiner NOA No'. 15-0304.01 Expiration Date: July 21, 2020 Approval Date: April 23, 2015 E-1 DAB. Door Company, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED C. CALCULATIONS (Cont.) "Submitted under NOA # 11 -0414.12" 2. Anchor verification calculations prepared by Al-Farooq Corporation, complying with F.B.0 2007, dated 04/07/2011, signed and sealed by Javad Ahmad, P.E. 3. Anchor verification calculations prepared by Al-Farooq Corporation, complying with F.B.0 2007, dated 12/19/2008, signed and sealed by Humayoun Farooq, P.E. "Submitted under NOA # 09-0128.02" D. QUALITY ASSURANCE . 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance N6.13-0717.01, issued to SABIC Innovative Plastics, for their Lexan Sheet Products, approved on 11/28/2013 and expiring on 07/17/2018. 2. Notice of Acceptance No.14-0311.08, issued to Insulfoam,_ LLC, for their Insulfoarn Expanded Polystyrene Insulation, approved on 08/14/2014 and expiring on 11/29/2017. 3. Notice of Acceptance No.11-0926.07, issued to Dyplast Products, LLC, for their Expanded Polystyrene Block Type Insulation, approved on 11/10/2011 and.expiring on 01/11/2017. 4. Notice of Acceptance No.11-0926.06, issued to Dyplast Products, LLC, for their Dyplast ISO-C1 Polyisocyanurate Insulation, approved on 11/10/2011 and expiring on 01/11/2017. 5. Notice of Acceptance No.10-1129.04, issued to Cellofoam North America Inc, for their Expanded Polystyrene Block Insulation, approved on 02/24/2011 and expiring on 02/24/2016: "Submitted under NOA ## OS-0228.02" 6. Test Report on Accelerated Weathering Using Xenon -Arc Light Apparatus Test per ASTM G 15 5 of "PVC Extrusion Material", prepared by Hurricane Engineering & Testing, Inc., Report No. HETI 04-A002, dated 09/27/2004, signed and sealed by Rafael E. Droz-Seda, P.E. 7. Test Reports on Tensile Test per ASTM D638 of "PVC Extrusion Material", prepared by Hurricane Engineering & Testing Inc., Report No. HETI 04-T251, dated 11/29/2004 signed and sealed by I..Ghia, P.E. 8. Test Report on Self -Ignition Temperature 'Pest, Rate of Burn Test and Smoke Density Test of "REHAU non -foam PVC extrusion material", prepared by ETC Laboratories, Report No. 04-761-15019.0, dated 05/06/2004, signed and sealed by J. L. Doldan, P.E. F. STATEMENTS "Submitted under NOA # 14-0814.10" -1. Statement letter of code conformance to the 51' edition (2014) FBC and no financial interest issued by Al-Farooq Corporation, dated 05/13/2014, signed and sealed by Javad Ahmad, P.E. Carlos M. Utrera, P:E. Product Control Examiner NOA No.15-0304.01 Expiration Date: July 21, 2020 Approval Date: April 23, 2015 E -2 7-1/2" X 2-1/4" X 18 GA. -- PL GALV. STEEL CENTER HINGE 0 w/ (4) #14 x 5/8" SMS \ ` WITHOUT. DELRON SLEEVE (STD.) 00 p 7-1/2" X 3" % .071" GALV. STEEL I END ROLLER HINGE i 00 W/ (6) #14 X 5/8" SMS WITHOUT DELRON SLEEVE (STD.) WITH DELRON SLEEVE (OPTIONAL) 1 p a 7-1/2" % 2-1�4" X .071" LOCH GALV. STEEL C NTER HINGE W/ (4) b14 % 5/8" SMS /-2/ DOOR WITH DELRON SLEEVE (OPTJONAL) � 01 O W % .15 THK. LATCH", ` CENTER HINGE STANDARD LOCK ` 1 SPRING LOADED SLIDE. BOLT (BOTH SH)k FASTENED W/ (4) #14 X 1/2" S.M.S. ----5/8" MIN. LOCK ENGAGEMENT CONFORMS TO SECTION 1008 REGARDING GARAGE DOORS r - .155 DIA. GALV. AIRCRAFT TYPE O CABLE & NICO-PRESS SLEEVE�'\�`� ip �`� B W/ MIN. 5 TO.1 SAFETY FACTOR I I 2-3/4'W X 5-5/8"H X .090" THK.'` (� IDOOR STEEL PLATE, 1-3/8" DEEP 1WITH (3) #14 X 3/4" � L)p iSELF DRILLING SCREWS BRACKETBRACKET STD. LIFT DOORW HEADROOM OPTION i TOTAL 0 OF DOOR 'U' BARS AT HEIGHT CONSISTS OF EACH DOOR 6'-6' 2 SECTIONS 18' _ 2 SECTIONS 21" 8'-9' 1 SECTION 18' J SECTIONS_21` 7' 4 SECTIONS 21' - 7'-3" - - 7'-G' 5 SECTIONS 18' - 7'-9" 4 SECTIONS 18" 1 SECTION 21" B' 3 SECTIONS 18' 2 SECTIONS 21' 8'-3' 2 SECTIONS 18" 3 SECTIONS 21" W-6' 1 SECTION 18' 4 SECTIONS 21" 8'-9' 5 SECTIONS 21- - 9' 8 SECTIONS 18' - 9'-3' S SECTIONS 18' 1 SECTION 21" 9'-6" 4 SECTIONS 18° 2 SECTIONS 21' 9'-8' 3 SECTIONS 18" 3 SECTIONS 21" 10' 2 SECTIONS 18' 4 SECTIONS 21' 10'-3' 1 SECTION 18" NS 21' 10'-6" 6 SECTIONS 21"10'-9' 6 SECTIONS 18'N 21" IV 5 SECTIONS 18'NS 21' 1V-3" 4 SECTIONS 18'NS 21" USEN 11'-8' J SECTIONS 18'NS 21" 11'-9" 2 SECTIONS 18'NS 21"12' 1 SECTIONS 18'NS 21'12'-3' 7 SECTIONS 21' 12'-6' 6 SECTIONS 18" 2 SECTIONS 21" 12'-9" 5 SECTIONS IB' 3 SECTIONS 21" 13' 4 SECTIONS 1B" 4 SECTIONS 21' IS-3" 3 SECTIONS 18' S SECTIONS 21' 13'-6" 2 SECTIONS 18' 5 SECTIONS 21" 13'-9' 1 SECTION 18' 7 SECTIONS 21" 14' 8 SECTIONS 21' 7 14'-3" 6 SECTIONS 18" 3 SECTIONS 21" 14'-6" 5 SECTIONS 18' 4 SECTIONS 21" 14'-0" 4 SECTIONS 18' 5 SECTIONS 21' 15' 3 SECTIONS 18' 6 SECTIONS 21" 15'-3" 2 SECTIONS 18" 7 SECTIONS 21' 15'-6" 1 SECTION 18' 8 SECTIONS 21" 15'-9" 9 SECTIONS 21' - 16' 6 SECTIONS 18' 4 SECTIONS 2P NUT- TOP FIXTURE 5-1/2" X 2-3/4" X 0.1" STEEL PLATE WITH ONE 5/16-18 MS W/ NUT -FASTENED TO END STALE WITH (6) #14 % 3/4" SELF DRILLING SCREWS .SEE SHEET 3 FOR TOP BRACKET OPTIONS CENTER STILES SEE SCH. 'A' OPTIONAL DOOR VIEWER TO BE INSTALLED AT ANY CENTER STILE I F-r-jil I I NO -III Irmiam 11. 7-7/8" X 3-1/8" X .010" ' OPTIONAL VENTS STEEL PLATE (3) 5" WIDE AT 7" O.C. MAX. WITH (4) #14 X 3/4" SOS OPNO. AREA NOT TO EXCEED 120 SO. IN. CENTER STILE - OUTSIDE HANDLE END STILE 4 LOCK BAR GUIDES ' INSTALLED ON END STILE c . WITH (4) #14 X 5/8" SMS 4 .18T X .6W LOCK DAR ENGAGES IN TRACK ON EACH SIDE OF DOOR OUTSIDE KEYED LOCK CENTER STILES PO TIONAL LOCK BAR LOCKING SHOWN ITT ALTERNATE TO SPRING LOADED SLIDE BOLT LOCKS SHOWN 'ABOVE 8'-0" TO DOOR WIDTHS 10'-0" TO I V-I O" _ I DOOR WIDTHS OPTIONAL FLUSH FACE I WOOD GRAIN DESIGN L A INSIDE ELEVATION. DAB DOORS INC. RAISED PANEL EMBOSSED DOOR Hurricane Master® Model Max. Size 16'-2" X 16'-0" 1 High _ With Window Lite Option �J74 X 3/4" SELF DRILLING SCREWS MAY BE USED N uEu aF pta x 5/B" SMS DESIGN PRESSURE RATING = + 36.0 PSF THIS PRODUCT IS RATED FOR LARGE MISSILE IMPACT GENERAL NOTES — 44.0 PSF I. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE (FBC) FIFTH EDITION (2014) INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). SCHEDULE 'A' L E HOW ILS CENTER STILES CONFIGURATION DOOR WIDTHS 8 OF CENTER STILES W-0" TO W-10" 2 10'-0' TO 11'-10" 12'-0' TO 13'-10" 3 14'-O" TO IS'-10" 15'-11" TO I6'-2' --5 2, ANCHORS SHAL B AS LISTED, SPACED AS S N ON DETA ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. 3. ALL BOLTS, NUTS AND WASHERS SHALL BE ZINC PLATED CARBON STEEL. 4, ANCHORING OR LOADING CONDITIONS OTHER THAN THOSE SHOWNAN THESE DETAILS ARE NOT PART OF THIS APPROVAL. 5, A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY BOOR TESTED IN ACCORDANCE WITH THE REQUIREMENTS OF FLORIDA BUILDING CODE, TAS-202, TAS-201 & TAS-203 FOR HVHZ AND rl I=11-=--fl DOOR WIDTHS ,moo m ICI ICI. .�I ®®.0. �.® II I Wes' 12'-0" TO 13'-10"TO 16'-2" DOOR WIDTHS DOOR WIDTHS FLA. PE 70592 CA.N. 38 djr2015 Pft�OWy4TL1�R6H8WBD Amplie`ldatt�ctoec���' am No00 I or m �d rowing no. 02-21 .055" v 2-1/4" X 3/4" X 2" - -- GALV STEEL U.BAR REINFORCING TRUSS a, BOTTOM OF PANEL TRUSS FASTENED TO VERROAL INTERMEDIATE STILES W/ TWO H14 X 5/8" S.M.S, AND TO END STILE - - X 3/4" SELF DRILLING S. Z - L#W/FOUR14 UU' z � U _ .2 LL kz 1ST SECTION (BOTTOM) INTERMEDIATE SECTION TOP SECTION -,OPTIONAL STOP MOULDING ' BY DOOR INSTALLER STEEL TRACK BRACKET FASTENED TO WOOD JAMB WITH 14 % 5/8" SMS 5/16" X 1-5/8" LAG SCREW _ 6 PER HINGE _ (FULLY THREADED) HEX,WASHER HEAD TYPEA 1/2" X 1-3/4" X ,058" FORMED STEEL ONE PER BRACKET CLUED TO PANEL AND SECURED TO END STILE WITH (4), 3/16" POP RIVETS SOUTHERN PINE `.a� 1-7/8" X 2-5/8" X .049" STEEL 0.55 S. " CENTER STILE, GLUED AND RIVETED PANEL W/,(4) 3/16" RIVETS 3/16" MIN. �TO S.M.S. POP RIVETS 11- DIST. rIf 4/1HINGE/8" 24 GA. STEEL PANEL - �U m FLAPS BENT OVER PANEL 0kk 1 GG �O 3 1 /2" PUNCHED HOLES) I` ® 4" D.C. �a C I 0�� 0��O Y� F dui 3/16" POP RIVETS AT 4" D.C. (6) FOR 21" STILES a) (5) FOR 18" STILES M .024" STL. PANEL END STILE N > M ¢ OUTSIDE OF ODOR LLi (3 a N Z z — 8 ID Lb w (n 0) p I e it O .6 SOLID BRASS DOOR VIEWER m0O ¢ w BY 'SCHLAGE SECURITY HARDWARE' 3/4" X 2" X 2-1/2" X .049" STEEL END STILE, CONNECT TO PANELS WITH INSTALLED. IN 9/16" DIA. HOLES IN CENTER STILE FLAPS AND (5) OR (6) 3/16" ALUM RIVETS POSITIONED AT EYE LEVEL SEE DETAIL ABOVE ANCHORS AT TRACK BRACKET: z EDGE 3/8' DIA, POWER -BOLT BY 'POWERS' o n 17 n DISTANCE A) 2" MIN. EMBED INTO CONCRETE (3000 PSI MIN.) o 2" MIN. EDGE DISTANCE 3�3 ° I j/e' Dla HLC SLEEVE BY 'HILTI' U 1-3/18c� °' 1e'°e, I• I B) 1-1/4" MIN. EMBED INTO 'CONCRETE OR FILLED BLOCK 2-1/4" MIN. EDGE DISTANCE INTO CONCRETE I 1-3/16"4" MIN. EDGE DISTANCE INTO FILLED BLOCK �i 1 � o v a m CONCRETE Vc - 3000 PSI MIN. C-90 GROUT FILLED BLOCK I'm = 2000 PSI MIN. '0 1.9" X 2.19" X 3.3" X .090" ANCHOR TYPE A OR B n x_ STEEL TRACK BRACKETS 1 1 I I I PER BRACKET 0 SEE SHEET 3 FOR SPACING $E(I) E SHEET 3 FOR BRACKET SPACING o I I En9r: )ACM AHMAD af�U�'i'ilGNEWB� o -6 PE 70592 �copril •IIUII�M il011d� �i I 3zi 7-1 2" X •050" 7-11 2" X .071" 1/4-20 SS BOLT CA.N. 78 BALiI� / INTERIOR SIDE / & NUT a GALV. STEEL END ROLLER HINGE STEEL TRACK CENTER HINGE O 14 GA. X 2-1/8" X 1" (STANDARD) 1.82" DIA. % .50" STEEL ROLLERS (STD.) drawing no. 12 GA. % 3-5/16" % I-1/2" (OPTIONAL) 7/B" PUSHNUT 1.82" DIA. X .50" NYLON ROLLERS (OPTIONAL roi Q .Q15 r'� FASTENED TO 8"TRTRACK PLATES INSTALLED ON ROLLER SHAFT 2.75" DIA. X .50" STEEL ROLLER (OPTIONAL — OG W/ 1//4-2D X M.S.TRUSS UTD. 2.75" DIA. X .50" NYLON ROLLERS (OPTIONAL) SLOTTED .S. &COCK NUT SECTION B-B WITH 5" STEM sheet 2 of 5 RIVETS 5/16" X 1-5/8" LAG SCREWS INTO WOOD OR 2-3/4" X 5-1/2" X 3" X .104" • 5/16" SLEEVE ANCHORS GALV. STEEL WITH 1-1/4" EMBED INTO MASONRY SOP ROLLER BRACKET ON EACH SIDE 3 PER BRACKET FASTENED W/ (6) # 14 X 5/8' S.M.S. 14 GA. GALV. STEEL ADJUSTABLE SUDS FASTENED TO BRACKET 2-1/2" % 4-1/4" % 13 GA. STEEL PLATES 8 X HEX HEAD �M. WELDED TO 1-1 2 X,1-1/2" X 14 GA. ANGLE / FASTENED TO TRACK " NUTS. M. SCREWS &NUTS. CREWS WITH (4) 1/4-20 SS. BOLT &NUTS TOP BRACKET (STANDARD) TOP. BRACKET % .J (OPTIONAL) - LOW HEADROOM DOOR , HORIZONTAL REINFORCEMENT 1/2" X 1-3/4" X .058" FORMED STEEL - -GLUED TO PANEL AND FASTENED TO VERTICAL STILES WITH (2) 3/I6" POP RIVETS 2" X 5-1/2" X..104' GALV. STEEL FASTENED W/ (4) # 14 X 5/8" S.M.S. TOP ROLLER BRACKET FOR Low HFAnRnnM nnnR nPTInN HORIZONTAL REINFORCEMENT 1/2" X 1-3/4" X .058" FORMED STEEL GLUED TO PANEL AND FASTENED TO .VERTICAL STILES WITH (2) 3/16" POP RIVETS 5/16" MEETING RIB PLASTIC/STEEL ROLLERS 1.82" DIA. X .50" ® �W/ .44 DIA. X 4-1/4" STEM OPTIONAL INSULATIONS: BY 'DYPLA T PRODUCTS LLC' EPS-EXPANDED POLYSTYRENE DENSITY - 1.05 PCF N.OA. #11-0926.07 OR ISO-25 POLY-ISOCYANURATE DENSITY = 2.0 PCF ___N.OA. #11-0926.06 OR BY 'CELLOFOAM NORTH AMERICA' DENSITY - 1.03 PCF N.O.A. #10-1129.04 OR BY 'INSULFOAM LI_C' . DENSITY = 0.92 PCF \N.O.A. #14-0311.08 14 GA. GALV. STEEL W/ (6) NI 14 X 5/8E SMS MIN..024" ROLL FORMED STEEL PANEL DRAWING QUALITY G-40 MIN. YIELD STRENGTH = 39 KSI ----""-'----- WITH PRIMER AND BAKED -ON POLYSTER PAINTED TOP COAT "APPLIED TO BOTH SIDES OF STEEL 12 GA. GALV. STEEL BOTTOM BRACKET FASTENED W/ (4) #14 X.5/8" SMS BOTTOM SEAL OPTIONS SEE SHEET 5 SECTION A -A SEE SHEET 2 FOR LOCATION OF REINFORCING TRUSSES HORIZ. TRACK SUPPORT. CENTER SUPPORT READ. ON DOORS EXREEDING 8 FT. IN HEIGHT it II A II A_-J HnPI7 TRACu I FNr'TH = nPFNING HEIGHT PLUS 14 GA. GALV. STEEL TRACK 1-1/2" X 1/2" X 1/8" HORIZ. ANGLE FOR DOOR HEIGHTS UPTO 8 FT. WITHOUT INSULATION OR WINDOWS, 2" X 2" X 1/8" HORIZ. ANGLE FOR DOOR HEIGHTS ABOVE 8 FT. OR DOORS WITH INSULATION OR WINDOWS SPOT WELDED TO HORIZ. TRACK WITH TWO WELDS AT 1-1/2 ART FIRST AT 3" O.C., REST AT 9" O.C. CONNECTED TO FLAG BRACKET ANGLE W/ 3/8-16 X 3/4" BOLT & NUT AND TO SPRING SHAFT GUIDE WITH (2) 1/4-20 X 5/8" BOLT & NUT VERTICAL TRACK jF 2-1/8" % 1" X .080" SECTION A -A DOOR - SECTION .HEIGHTS I BRACKET PLACEMENTS HEIGHT 1ST 2ND 3RD 4TH 5TH 81 1 B2 133 84 I 85 136 87 B8 8" N/A 1" TO 2" 11-3/4" 23" 34" 45"' S6" 67" - 6'-6" 1" N/A 1" TO 2" 11-3/4" 23" 34" 45" 56" 67" - 7'-0" a8l 1" N/A 1"TO 2" 11-3/4" 23" J4" 45" 56" 67"B"18" 1" TO 2" 11-3/4" 23" 34" 45"618" 2d ". 1" TO 2" 11-3/4" 2J" 34" 45" 56"' 67" 78-1/4" -SECTIONS ARE NUMBEKGU WMIINV AI IML n IUM FOR DOORS MORE THAN 8 FT. HIGH, USE ADDITIONAL TRACK BRACKETS AT 10" O.C. 1.9" X 2.19" X 3.3" X .090" Z STE& TRACK BRACKETS / nm 2-3/16" HIGH / CONNECTED TO TRACK WITH 1/4' BOLTS & NUTS. m a) m TRACK CONFIGURATION VERTICAL LIFE dIGH L1Q STANDARD LIFT LOW HEADROOM DOUBLE TRACK AVAILABLE. TRACK OPTIONS Engr: JAVAD AHMAO CIVIL PRODUCT RENEWED FLA. PE 70592 0 vAthBYPlod& C.A.N. 38 &dmbvoo& AmtyNooe No R ►� vtaala � ro O U L+1 M Z Z Z u 8 N LLI a) r3 1 0 < m 0 .o O o mO tl drawing no 02-21. z_ 1-1/2"MIN. s GL> o m I \ 3n � I 2BY WOOD t�'-Y-- 1/4" DIA. LAG SCREAT 6" FROM ENDSAND IS' O.C. MAX. Do 1/4" DIA. LAG SCREWS AT'6' FROM ENDS AND 15" O.C. MAX. OPTION 'A' \�—_Y OPTION '8\�__y WOOD BUCK CONNECTION TO WOOD SUBSTRATE (WOOD SPECIFIC GRAVITY SG=0.55 MIN.) THE INSTALLATION METHODS SHOWN ABOVE SHOWS 2X6 SYP WOOD BUCK ATTACHMENT TO WOOD STRUCTURES. IF THESE METHODS ARE FOLLOWED NO ADDITIONAL CALCULATIONS/DESIGN WILL BE REQUIRED FOR DESIGN OF GARAGE DOOR ANCHORAGE. FOR DOOR REPLACEMENT APPLICATIONS WITH NO ENGINEER OF RECORD, INSTALLATION MAY BE VERIFIED AND APPROVED BY THE BUILDING OFFICIAL UPON INSPECTION. 5/16" X 1-5/8" LAG SCREWS AT 12' O.C. WOOD BUCK CONNECTION TO MASONRY PRESSURE TREATED 2X6 SYP WOOD JAMBS WHICH SHALL BE ANCHORED TO GROUTED REINFORCED MASONRY BLOCK WALL OR CONC. COLUMN WITH 1 1/4" ULTRACON BY 'ELCO' WITH SPACING OF 12" O.C. INTO GROUT FILLED BLOCK WALL, WITH 2-1/4' MIN. EMBED INTO 13" O.C. INTO 3000 PSI CONCRETE, WITH 1-3/4" MIN. EMBED 2-1/2" EDGE DISTANCE 11-1/2" 1/4" TAPPER BY 'POWERS' WITH SPACING OF 11" O,C. INTO GROUT FILLED BLOCK WALL, WITH 1-1/2' MIN. EMBED 13" O.C. NTO 3000 PSI CONCRETE, WITH 1-3/4" MIN. EMBED 3" MIN. EDGE DISTANCE 3/e" CONFLEX BY 'ELCO' OR 3/e" LOT BY 'ITW' WITH SPACING OF 23" O.C. INTO 3000 PSI CONCRETE, WITH 2-1/2" MIN. EMBED 3" MIN. EDGE DISTANCE CONTINUOUS ANGLE TRACK 3/8" HLC SLEEVE BY 'HILTV WITH SPACING OF IO WOOD BUCK 10 O.C. INTO GROUT FILLED BLOCK WALL, WITH MIN, EMBED. 4" MIN. EDGE DIST. ,1-1/4' 15' O.C. INTO 3000 PSI CONCRETE, WITH 1-1/4" MIN. EMBED AND 2-1/2" MIN. EDGE DISTANCE PREPARATION OF JAMBS BY OTH RS FOR NEW CONSTRUCTION ENGINEER OF RECORD OR ARCHITECT TO VERIFY ADEQUACY OF SUPPORTING STRUCTURE TO SUPPORT LOADS IMPOSED BY DOOR SYSTEM. FOR DOOR REPLACEMENT IN RETROFIT BUILDINGS WITH NO ENGINEER OF RECORD, DOOR INSTALLATION MAY BE REVIEWED AND APPROVED BY BUILDING OFFICIAL UPON INSPECTION. MAXIMUM EXTERIOR(+) LOAD PER JAMB (16.16' X 62 PSF)/2 291 Lbs par FL. MAXIMUM INTERIOR(-) LOAD PER JAMB (16.16' X 44 PSF)/2 355.5 Lbs per FL. 1/16" X 2-1/2" FILLET WELDS AT 12"'O.C. MAX. R8 X 1" SELF DRILLING SCREWS OR 3/16" 'RIVEX' STEEL RIVETS MULTIGRIP W/ DOME HEAD AT 48" O.C. REINFORCEMENT 1/2" X 1-3/4" X .058" FORMED, STEEL :INFORCEMENT '2' X 1-3/4" X .058" IRMED STEEL p8 x I - SELF DRILLING SCREWS z OR 3/16" 'RIVEX' STEEL RIVETS MULTIGRIP W/ DOME HEAD AT 48" O.C. C IL a� o a — tom✓\ 8'0 ry�ry11 W'STRIP ADAPTER o WW pt ALUMINUM STEERIP ADAPTER 0 k 7 Q LLQ Fr �' dl 0000 m RUBBER W'STRIPPINGT RUBBER W'STRIPPING Cr C 050 D7 LL 1.790 y g ,224 -IIS �J IS �J.J 4 p •040 348 lil'S.'jj 5� F�-.1.750 � -� STEEL STRUCTURE BY OTHERS MUST SUPPORT THE LOADS IMPOSED BY DOOR SYSTE[[[IM 5/16" DIA. BOLTS FWITH WASHER & NUT AT 12" O.C. MAX. 1-1/2" REVERSE TRACK TO STEEL ALTERNATE TRACK INSTALLATION ANCHOR SPACING _ ANCHORS STRUCTURE EMBED SPACING EDGE DIST. 3 8 HLC SLEEVE BY HILTI CONC. 1-1 4' 8" 2" 3 8" CONFLEX BY "ELCO FILLED BLOCK 8' 3-3 4 3 8' DYNABOLT BY ITW' CONC. 1-1"2' 6" _ 2-1 2' 3 B POWER -BOLT BY POWERS CONIC_ 2" 1- .3/8- SLEEVE -ALL BY SIMPSONS CONC, _ 1-1 2' _ 8" 3_. CONCRETE Ft - 3000 PSI MIN. C-90 GROUT FILLED BLOCK I'm = 2000 PSI MIN. \"' .o w" X 2-1/2" X 14 GAIF STEEL ANGLE I1-1/2' 12 GA. GALV. STEEL FLAT BRACKETS t3' LONG 2-1 /e" X I" X 14 GA. AT 12" O.C. IN DOOR OPNG. GALV. STEEL TRACK AT 18" O.C. ABOVE DOOR OPNC. FASTENED TO TRACK PLATES CONNECTED TO CONT. ANGLE W/ (2� 1/4-20X5/8" TRUSS HD. W/ (3) SPOT WELDS AT EACH SIDE CONTINUOUS IQ CONCRETE SLOTT 0 .4. & LOCK NUT ANGLE TRACK AND FILLED BLOCK gr: JAVAD AHMAD o CIVIL PRDDUCFRENEWED S fLA. PE qq 70592 fi00mp1)1fld wm 11N FkwA o I C.A.N.'3538 awdho CLie ' Mnp4w No /557-DU4.0/ d02 9 21no.l 2015 ' DOOR PANEL 24 GA. (.024) STEEL MIN. 7/16" DIA. WASHER 1 #8 X 3/4" SMS At e 3/8" FROM ENDS II AO A 'III 1 11 AND 7" O.C. MAX. III I I , 11 (4) #8 X 3/4" SMS I�11 I e 1-3/8" FROM ENDS IIII i �� AND 6-1/2" O.C. MAX. L III I IIII IIII .175 X .062 DEEP ' IIII I I IIII GROOVE. IIII II 1/4" POLYCARBONATE LEXAN IIII I I BY 'SABIC INNOVATIVE PLASTICS' IIII III NOA #13-0717.01 Ij O 3 Zp J F- W IIII � IIII I I IIII IIII IIII I I IIII IIII IIII IIII 175 X .062 DEEP • IIII GROOVE III 1 II I I I it (4) #8 X 3/4" SMS I ® 1-3/8" FROM ENDS I I III I I AND 6-1/2" O.C. MAX. 8 O I I I I I I I I 1 1 I I I 1 98 X 3/4" SMS "'� a 3/8" FROM ENDS _ AND 7' O.C. MAX. 7/16" DMA. WASHER DOOR PANEL \. 24 GA. (.024) STEEL MIN. * PLASTIC COMPLIES WITH CHAPTER 26 OF FBC SEE EVIDENCE PAGE .500 250 U N 1.765 1.725 a g 1.144 41 O LL I .176 F� I�--.e00 O Q Q O LL Zth_ o d 0 w O It M >w M Q Z I N Z. to 8 (Jj m O 1 03�� O Z= o o 04x ii INSIDE ELEVATION RAISED PANEL EMBOSSED DOOR WITH OPTIONAL WINDOWS WINDOW LITES CAN BE IN ANY LOCATION IN DOOR SECTION d8 X 3/4" SMS C ' 0 3/5" FROM ENDS .175.X .062 DEEP AND 4-1/2" O.C. MAX. ` GROOVE I \I ____ Engr: JAVAD AHMAD PR�%' RENEWED Ro. - - - - - - - - - CIVIL L r dw _ 5 2 ILA. PEN 10BUII I �\ -� ___-„ CAN. 538 A NO � � U a DOOR PANEL EXTERIOR vo 24 GA. (.024) STEEL MIN. 15/16" MIN. D.L. OPG. c 15 CO� drawing no. GLAZING BITE - 02_21 WINDOW WIDTH , sheet 5 of 5