Loading...
HomeMy WebLinkAboutProduct Approval (4) Florida Building Code Online 'fte '� Fly.60 1 t.� � #�!C _-ALA �' f .4 i "Y Si. Ae .. .- , '�•4 �IH .BCIS Home ? log In i User.Registration Hot Topic Submit Surcharge .Stats&Facts'..''Publications I FBC Staff BCIS Site.Map Links Search S d: 1F P1. Product Approval _ r USER:Public User. �... Product Aor)royal Menu>Product or AOolication Search>Application List>Application Detail ` FL,# FL15349-117 ' Application Type ` Revision Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer MI Windows and Doors Address/Phone/Email 650 West Market Street Gratz,PA 17030 (717)365-3300 .Ext.2560 bsitlinger@mlwd.com Authorized Signature Brent Sitlinger bsitlinger@miwd.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category dWindows Subcategory Fixed Compliance Method Certification Mark or Listing Certification Agency American Architectural Manufacturers Association Validated By Steven M.IJH6,PE �' Validation Checklist.-Hardcopy Received Referenced Standard and Year(of Standard) Standard Year AAMA 506 2008 AAMA/WDMA/CSA 101/I.S.2/A440 2008 Equivalence of'Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 06/20/2016 Date Validated 06/20/2016 Date Pending FBC Approval Date Approved 06/21/2016 httn://floridabuildin-.org/pr/pr app dtl.aspx?param=wGEVXQwtD tH8572gvdW1anDW... 8/24/2016 Florida Building Code Online Page L or Summary of Products FL# Model,Number or Name Description. 15349.1 185 Fin Frame 96x60 Insulated Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL15349 R7 C CAC APC B5393.02-109-47-r0 185 FXQ -Approved for use outside HVHZ:Yes FIN 13=161G 96X60 LC55_pdf Impact Resistant:No Quality Assurance Contract Expiration Date Design Pressure:+55/-55 12/05/2020 Other:FW-LC55.IG unit consisted of the following from Installation Instructions exterior to interior:5132"Ann-Air space-5/32"Ann/ FL15349 R7 II 18S Fin Fixed B5393 02 AS TESTED.odf 0.100"Solutia Saflex/5/32"Ann.Glazing bite was.1/2". Verified By:American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15349.2 185 Fin Frame 96x60 Laminated Single Glazed Limits of Use Certification Agency Certificate 'Approved for use in HVHZ:No FL15349 R7 C CAC APCB5393.03-109-47-r0 .1 85 FXD Approved for use outside HVHZ:Yes. FIN SG 96X60 LC55.ndf Impact Resistant:No Quality Assurance Contract Expiration Date Design Pressure:+55/-55 12/05/2020 Other:FW-LC55.Glass consisted of 5/32"Ann-0.100" Installation Instructions Solutia Saflex-5132"Ann with a 1/2"glazing bite. FLIS349 R7 II 185 Fin Fixed B5393.03 AS TESTEp nd` Verified By:American Architectural Manufacturers Association Created by'Independent Third Party: Evaluation Reports Created by.Independent Third Party: 15349.3 185 PW 96x60 Fin Frame Insulated Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL15349 R7 C CAC APC B5395.01-109-47-r0 B5393 01- Approved for.use outside HVHZ:Yes J09-47 185 FXD FIN 96X60 LC55 AAMA 506-06 OSSPEC ndf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure:+55/-55 12/05/2020 Other:FW-LC55,Missile Level D,Wind Zone 3.Glass Installation Instructions consisted of 5132"annealed exterior-.space-5/32" FLI S349 R7 II 185 Fin Impact Fxd BS395 01 AS annealed/0.100 Solutia Saflex HP/5/32"annealed.Glass TESTED.odf was bedded in Pecora 896 silicone with a 1/2"glass bite. Verified By:American Architectural Manufacturers Association Created;by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15349.4 185 PW 96x60 Fin Frame Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL15349 R7 C CAC APC 67020 02 185 Fxd Fin Imoact. Approved for use outside HVHZ:Yes 96x60.ndf . Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure:+55/-55 02/20/2021 Other:FW-LC55,Missile Level D,Wind Zone 3.Glass Installation Instructions consisted of 5/32"annealed-0.100"Solutia Saflex HP FL15349 R7 H 185 Fin'Imoact Fxd B7020 02 AS 5/32"annealed.Glass was bedded in Pecora 896 silicone TESTED.odf with a 1/2"glass bite. Verified By:American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15349.5 185 PW. 96x60 Flange Frame Single Laminated Glass Limits of Use Certification'Agency Certificate Approved for use in HVHZ:No FL15349 R7.C CRC APC 87020 02 185'Fxd Fla Impact Approved for use outside HVHZ:Yes 96x60:odf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure:+55/-55 02/20/2021 Other:FW-LC55,Missile Level D,Wind Zone 3. Installation Instructions Backbedding silicone is Pecora 896. FL15349 R7 11 DS-01613A odf Verified By: Luis R.Lomas,PE PE-62514 Created by Independent Third Party:Yes Evaluation Reports FL15349 R7 AE St2277- A.pdf Created by Independent Third Party:Yes 15349.E 185 PW 96x60 Flange Frame Insulating Laminated Glass http://floridabuilding.org/pr/pr app_dtl.aspx?paratn=wGEVXQwtDgtH8572gvdWIanDW... 8/24/2016- Florida Building Code Online Fage-i of Limits of Use Certification Agency Certificate Approved for use in HVHZ:No• FL15349 R7 C CAC APC 135395 01-109-47-rO 05393.02_- Approved for use outside HVHZ:Yes 109-47`185-FXD FLG 96X60 LC55 AAMA 506-06 05SPEC Impact Resistant:Yes t 1205151:odf Design Pressure:+55/-55 Quality Assurance Contract Expiration Date Other:FW-LC55,Missile Level D,Wind Zone 3.The glass 12/05/2020 was bedded in Pecora 896 silicone with a 1/2"glass bite.. Installation Instructions FL15349 R7 1I 08-01613A.Odf Verified By: Luis R..Lomas,PE PE-62514 Ceeatedby Independent Third Party:Yes Evaluation Reports FL15349 R7 AE 512277A:odf Created by Independent Third Party:Yes -15349.7 185 PW 72x72 Fin Frame Single Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ:No. FL15349 R7 C CAC APC COS71 03-109-47-RO 185 FIXED Approved for use outside HVHZ:Yes 72x72 FIN.pdf. Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure:+55/-55 06/25/2021 Other:LC-PG55;Missile Level D,Wind Zone 3. 1/2"glass Installation Instructions .bite,glass was bedded in Pecora 896.silicone sealant: FL15349 R7 li 08-0235SA.pdf Verified By: Luis R.Lomas,PE PE-62514 Created by Independent Third Party:Yes Evaluation Reports FL15349 R7 AE 513122A.6df Created by Independent Third Party:Yes 15349.8 185 PW 72x72 Flange Frame Single Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL15349 R7 C CAC APC C0571.03-109=47-RO 185 FIXED Approved for use outside HVHZ:Yes 72x72 FLANGE.pdf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure:+55/-55 06/25/2021 Other:LC-PG55.Missile Level D,Wind Zone 3.1/2"Glass Installation Instructions bite,glass was bedded In Pecora'896 silicone sealant. FL15349 R7 II 08-02355A.pd€ Verified.By:Luis R.Lomas,PE PE62514 Created,by Independent,Third Party:Yes. Evaluation Reports FLIS349 R7 AE 513/22A.DdF Created by Independent Third Party:Yes 15349.9 185 PW 73x72.Fin Frame Insulating Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FI 15349 R7 C CAC APC CC'I-14-060 185 FIXED FiN.Odf Approved for use outside HVHZ:Yes' Quality Assurance Contract Expiration Date Impact Resistant:No 04/03/2018 Design Pressure:+60/-60 Installation Instructions Other:CW-PG60 FI-15344 P,7 1I 08-02357A.pdF 4 Verified By: Luis R.Lomas,PE PE-62514 Created by Independent Third Party:Yes Evaluation Reports FL15349 R7 AE 513124A.6dF Created by Independent Third Party:Yes 15349.10 185 PW 73x72 Flange Frame Insulating Glass Limits of Use. Certification Agency Certificate Approved for use.in HVHZ:No FL153-19 R7 C CAC APCCCLI-14-060 185 FIXED FLG.Ddf Approved for use outside HVHZ:Yes Quality.Assurance Contract Expiration Date Impact Resistant:No 04/03/2018 Design Pressure:+60/-60 Installation Instructions' Other:CW-PG60 FLIS349 R7 11 08-02357A.pdf Verified By: Luis R.Lomas,PE PE-62514 Created by Independent Third Party:Yes Evaluation Reports FL15349 R7 AE 513124A..pd€ Created by Independent Third Party:Yes 15349.11 185 PW 72x72 Flange Frame Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FLIS349 R7 C CAC APC C0571.03-109 47 RO C0571.02 Approved for use outside HVHZ:Yes 109-47-RO 185 FIXED FLG SG 5-32A.100HP 5-32A 72x72 Impact Resistant:Yes LC55•pdf Design Pressure:+55/-55 Quality Assurance Contract Expiration Date Other:LC-PG55;Missile Level D,Wind Zone 3.Glass bite is 06/25/2021 1/2"and glass Is bedded in Pecora 896:silicone. Installation Instructions, FLIS349 0 II 08-02355A.Ddf Verified By: Luis R.Lomas,PE PE-62514 Created by Independent Third Party:Yes Evaluation Reports http://floridabuilding.org/pr/pr_app_dtl:aspx?param=wGEVXQwtDgtH8572gvdWIanDW... 8/24/2016 . a (Validator/Operations Admmistiator) CERTIFICATION:PROGRAM . AUTHORIZATION FOR PRODUCT CERTIFICATION,: MI Windows&Doors,LLC P.O.Box 370 Gratz;PA 17030-0370 . Attu:'.Rick<Sawdey: The product descnbedbelow,is hereby approved for;listing in the next.issue of.the AAMA Certified Products Directory: The approval is based on successful completion of tests,and the-reporting to the;Administrator:of the results of tests;accompanied by related drawings, by an AAMA Accredited:Lab.oratory: 1.The listing below will be added to the ne)d published-AAMA Certifed Products Directory SPECIFICATION. RECORD OF PRODUCT TESTED AAMAPNDMA/CSA 101/l.S.2/A440-08: CW PG604842x1816(73x72)-FW SERIES MODEL 8 PRODUCT: COMPANY AND CODE CPD NO. MAXIMUM SIZETESTED DESCRIPTION MI Windows Doors,LLC 185 PW(FLANGE)...- FRAME 12787•. (AL)(0)(OG)(INS GL) 1842 nun 1816 mm Code .MTL (6.1 X s,0..).: (AST 2.-This Certification annll expire Apn1;3;3018 and requires validation until then by continued listing in the current AAMA CdMed Products Directory: 3 Product Tested and Reported by `Construction Consulting Laboratory;_International Report No.: CCU44-060 Date of Report: June 2,2014: J. Validated for Certification oq ted Latiorato nes,Inc: Date: June 27,2014 ': Au;obrized for Certification ; Cc`: AAMA JGS ' American Architectural Manufacturers Association a . AAMA (Validator OperationsAdministmtor) CERTIFICATION PROGRAM AUTHORIZATION FOR PRODUCT CERTIFICATION MI Windows&Doors,LLC P.O.Box 370 . Gratz,PA 17030-0370 Attn: Rick Sawdey: The product described below is hereby approved.for.listing in the next issue of theAAMA Certified Products Directory. The approval is based on successful completion of tests,and the reporting to the Administrator of the results of tests,accompanied by related drawings, by an AAMA Accredited Laboratory. 1.The listing below will be added to the next published AAMA Certified Products Directory. SPECIFICATION . RECORD OF PRODUCT TESTED AAMANVDMA/CSA 101/I.S.2/A440-08 CW-PG60-1842x1816(73x72)-FW SERIES MODEL&PRODUCT COMPANY AND CODE CPD NO. MAXIMUM SIZE TESTED. DESCRIPTION MI Windows&Doors,LLC 185.PW(FIN) FRAME Code:MTL 12786 (AL)(U)(OG)(INS GL) 1842 mm x 1816 mm. (ASTM) (61"u 6'0") 2.This Certification will expire April 3;2018 and requires validation until then by continued listing in the current AAMA Certified Products Directory.,.. 3.Product Tested and Reported by: Construction Consulting Laboratory,International Report No.: CCLI-14-060 Date of Report: June 2,2014 Validated for Certification A oci ted Laboratories, Inc. Date: June 27,2014 Authorized for Certification Cc: :AAMA . JGS ACP-04 (Rev. 1/11) American Architectural Manufacturers Association RNSIDNS REV DESCRI'MN DATE APPRMW A REVISED INSTALLATION DETAILS 06/01/15 R.L. NOTES: 15. FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH i. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE REQUIREMENTS OF THE FLORIDA BUILDING CODE. ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE 2. .`TRANS FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY I6. FOR ANCHORING INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH RESPONSIBILITY OF THE ARCHITECT,OR ENGINEER OF RECORD. TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE 3, 1X BUCK.OVER MASONRY/CONCRETE IS OPTIONAL, DISTANCE. LOCATE ANCHORS AS SHOWN hN ELEVATIONS AND INSTALLATION DETAILS. 4. WHERE,SHIM OR BUCK THICKNESS IS LESS THAN-1-1/2" WINDOW UNITS MUST BE 17.'FOR'ANCHORING INTO METAL STRUCTURE USE ' 10 SMS OR SELF DRILLING SCREV4S WITH , ANCHORED THROUGH THE FRAME IN.ACCORDANCE WITH MANUFACTURER'S PUBLISHED.- SUFFICIENT LENGTH TO ACHIEVE 3 THREAOS tvIINtMUM BEYOND STRUCTURE INTERIOR WALL. INSTALLATION INSTRUCTIONS. ANCHORS'SHALL BE SECURELY FASTENED D;RECTLY INTO LOCATE ANCHORS AS'SHOWN 1N ELEVATIONS AND.INSTALLATION DETAILS. 1'8. ALL FASTENERS TO BE CORROSION RESISTANT. MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 19. INSTALLATION ANCHORS SHALL Bc INSTALLED IN ACCORDANCE WITH ANCHOR 5. FASTENED D TO BUCK THICKNESS T OR OTHER OR GREATER, BUCK SHALL BE SECURELY MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY, SUBSTRATES WITH STRENGTHS LESS THAN THE-MINIMUM STRENGTH SPECIFIED BELOW:. BE ANCHORED THROUGH FRAME TO.SECURED 'MOOD BUCK IN ACCORDANCE WITH A:.WOOD MINIMUM SPECIFIC'GRANT Y OF 0=0.42 MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI. 6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED C. MASONRY — STRENGTH CONFORMANCE TO ASTM C-90, GRADE N. TYPE.1 (OR GREATER). COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. D. METAL STRUCTURE: STEEL 18GA, 33KSI OR ALUMINUM 6063—T5 1/8" .THICK IdINIbAUM 7:. BUCKS .SHALL'EXTEND BEYOND WINDOW INTERIOR FACE SO THAT 'FULL FRAME'SUPPORT IS 70,GEOMETRIC,SHAPES ARE•ALSO.APPROVED. QUALIFIED GEOMETRIC SHAPES SHALL BE PROVIDED. INSCRIBED IN A 72 1/27x71 1/2" AND SHALL NOT EXCEED 36 FT.'' 8. FOR.FIN INSTALLATION.SHIM AS NEEDED. FOR-FRAME INSTALLATION SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE.OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4 9:. SHIMS'SHALL. 0E LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS, 10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: ALUMINUM 6063—T5. 12..UNITS MUST BE GLAZED PER ASTM E1300-04, SEE SHEET 2 FOR GLASS DETAILS, 13. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED FOR THIS PRODUCT.IN WIND BORNE DEBRIS REGIONS. 14. FOR FIN INSTALLATION USE 66 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS.AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS, SIGNED:0610112015 M I WINDOWS AND DOORS L 0 � 1001 WEST CROSBY ROAD CARROLLTON, TX 75006 TABLE OF CONTENTS SERIES 185 ALUMINUM FIXED.,WINDOW =*• o, 61 # SHEET NO. DESCRIPTION 73" X 72" NON-IMPACT TEfOrrL!!t ` NOTES Ate•• STATE OF M NOTES DRAWN: DWC,KO, REV ��TF�F�OR.tOP• 4 — 6 INSTALLATION DETAILS AND GLAZING DETAILS scALE NTS °A� 09/03/]4 08 s0EET170F 8 A ///�ss/�NA�taG�\\ RENSIORS 72 1/2" MAX FRAME WIDTH REV DESCRIPTION DAtE APPROVED 69 3/1" MAX D.L.O.. A REVISED INSTALLATION DETAILS 06/01/15 R.L. 6" MAX - 18" MAX O.O. 6" MAX 5- MAX CHART#I Number of anchors required(without rigid fillers) 18" Frama Framo width(In) Holght 21.00 30.00 .36.00 42.00 48.00 54.00 60.00 66.00 72.50 MAX O.C. 0 pn) yAS emb yAS amb HAS Jambi HAS Pamb'HAS amb H6S Pamb HAS amb HAS amb HAS amb 68 3/4„ 24.00- 2 2 2 2 3. 2 3 -2 .3 2 .4 2 4 2 4- 2 52 MAX 30.00 2 2 2 2 3 2 3 2 3 2 4 2 4 2 4 2 5 2 D.L.O. 38.00 .2 .3 2 3 3 3 3 3 3 3 4 3 4 3 5 -3 5 3 71 1/2' 4ZOO 2 3 2 3 3 3 3 3 3 3 4 3 6 3 5 3 6 3 MAX 48.00 2 3 2 3 3 3 3 3 3 3 4 3 5 3 6 3 8 3 FRAME 84.00 2 4 2 4 3 4 3 4 3 4 4 4 5 4 '6. 4 7 4 HEIGHT 60.00. 2 4 2 4 3 4 3 5 3 5 4 5 5 5 6 .5 7 5 - 6A00 2 4. 2. 4� 3 5. 3' 5' 3 6 4. 6 6 .6 6 6 7 .6 71.50 2 .5- .2 5 _3 5' - 3 6 : 3 6 4 7 5 :'7 6, 7 7 L f+ ANCHORS 'TO BE. CHARTJ2 EQUALLY SPACED REFER TO CHARTS Number of anchors required(with rigid fillers) ' #1 & ✓I2 ZERIES 185 ALUMINUM FIXED.WINDOW Framo Framo width(In) FOR.NUMBER'OF EXTERIOR VIEW 1_09 t 24.00 30.00 ' 36.00 42.00' 48.00 s�o0 00.00 66.Go 7260' ANCHORS.REQUIRED (in) HAS amb HAS amb Hd5 amb HAS. amb HBS amb HAS amb HAS mb HAS amb HAS amb DESIGN PRESSURE RATING IMPACT RATING 24.00 2 2 2 2 3 2 3 2 3 2 4 2 4 2 4 2 5 2 30.00 2 2 2 2 3 2 3 2 3 2. 4 2 4 2 4 2 .5 2 +60.OPSF NONE 36.00 2 3 2 3 3 3 .3 3 3 3 4 3 4 3 4 3 6 3 42.00 2 3 2 3 3 3 3 3. 3 3 4 3 4 3 4 3 5 3 48.00 �2 3 2' 3 3 3 3 3 3 3 4 3 4 3 4 3 6 3 54:00 .2. 4 2 4 3 4 3 4 3 4 4 4 4 4 4 4 6 4 -b0.00 2 4 2 4 3 4 3 4 .3 "4. 4 4' 4 4 '4 06.00 2 4- 2 4 -34 -3 4 3 4 - 4 -4 - 4 4 4- 4 6 4 71.50 2 1 5 2 1 5 1 3 1 5 1 3 1 '5 1 3 5 4 5 4 1 5 1 4 1 S 1 6 5 SEE SHEETS 4-7 FOR INSTALLATION DETAILS 5/8" 3/16" ANN 3/16" ANN ALUMINUM REINFORCED BUTYL SPACER SIGNED;0610112015 EXTERIOR INTERIOR \\y\11111111)/ MI WINDOWS AND DOORS Lo SILICONE 1001 WEST CARROLLTON,RTX8 D 75006 6 x 1 1/4" TEK SERIES 185 ALUMINUM FIXED WINDOW *�•/��(�,0y�51/� `*= 73" X 72" NON-IMPACT b,LfsPa( ,�+xo�a` SPACED 2" FROM ELEVATION, CHARTS AND GLAZING DETAILS }1• STATEEEE OF ttrZ CORNERS AND 12" MAX 0 O.C. THEREAFTER GLAZING DETAIL u. Dd0 .D. OB-02357 RA '��i��Ss+/�0RIO�G���� SCALE NTS DATE 09/03/14 SSEET2 OF 8 ///i�NAVI \\)�. REVIs1oNs REV DESCRIPTION DATE APPROVED 1 O6 01 15 R.L. N DETAILS A REVISED INSTALLATION 1 1 WIDTH -----72 1 2" MAXX FRAME 4 VI D 69 3/4" MAX D.L.O. 6" MAX — 18" MAX O.C. --I 6" MAX 18" . 'MAX O.C.` 4F.. CHAATNI 00 68 3/4" Number of anchors required(On Installation) MAX Framo Fremo width(in) ' D.L.O. Height 24.00 30.00 1 36.00 1 42.T44 .00 54.00 60.00 66.00 72.50 71 1/2" (in) HdS smb HdS amb H&S amb H&S amb HdS amb HBS amb H8S amb H&S Jamb MAX _ - 24.00 3 3 3 3 3 3 4 3 4 3 5 3 5 3 6 3 FRAME 30.00 3 3 3 3 3 3 4 3 4 3 5 3 5 3 6 3 HEIGHT 38.00 3 3 3 3 3 3 4 34 3- 5 3 5 3 8 3 42.00 3 4 3 4. 3 4 4 4 4 4 5 4 5 4 6 4 - - 49.00 3 4 3 4 3 4 4 44 4 5 4 5 4 8 4 oo 54.00 3 4 3 4 3 4 4 4 4 4 5 4 5 4 6 4 60.00 3 5 3 5 3 5 4 5 4 5 4 5 5 5 5 5 6 6 ANCHORS TO BE 66.00 3 5 3 "5 3 5 4 5 4 5 4 5, 5 5 5 5 6 5 EQUALLY SPACED V.50 3 6 3 1 6 1 3 1 6 1 4. 6 a 1 s 1 4 6 5 51 6 6 6 6 REFER TO CHARTS #1 & #2 ZSERIES 185 ALUMINUM FIXED WINDOW SEE SHEET 8 FOR INS TTALLATION DETAILS FOR NUMBER'017. EXTERIOR VIEW ANCHORS REOUIRED DESIGN PRESSURE RATING IMPACT RATING t60.0PSF NONE SIGNED:0610112015 MI WINDOWS AND DOORSD�i,,�i . 1001, WEST CARROLLTON R OSBY D \TX.75006 \J\v�G g N SF ytP�i� SERIES 185 ALUMINUM FIXED WINDOW 73" X 72" NON—IMPACT mE ,tv ELEVATION, CHARTS AND GLAZING DETAILS •: TAT OF DRAV.'N: DWO N0. REV P••�\ 0iO�•'��ORIO. �\ S •...• C���� SJ.CALE CATS L. O8 SOE�357 A ��i7S�ONA;1S����. NTS 09/03/14 3 OF 8 REV610N5 REV DESCRIPTION DAfE APPROVED A RE'ASED MS-1ALIATION DETAILS 06/01/15 R.L. 1 '1/4".MIN. 1/4" MAX. EMBEDMENT SHIM SPACE �'— RIGID FILLER 1/2" MIN. 1/2" MIN EDGE DISTANCE INTERIOR 3/4" MIN EDGE DISTANCE METAL EDGE DISTANCE STRUCTURE WOOD FRAMING ---I OR 2X BUCK' 1 1/4" MIN• BY OTHERS 1/4" MAX. I I EMBEDMENT r SHIM SPACE.. #10 1'lOOD BY OTHERS 1 SCREW m e r 1 WOOD FRAMING EXTERIOR OR 2X BUCK 114" MAX. BACKER ROD- I-- �_ BY OTHERS BACKER ROD & APPROVED RIGID FILLER & APPROVED BACKER ROD _ SHIM SPACE SEALANT & APPROVED RIGID FILLER pO SMS OR SEALANT SEALANT SELF DRILLING JAMB INSTALLATION DETAIL #10 WOOO SCREW SCREW WOOD FRAMING OR 2X BUCK INSTALLATION EXTERIOR INTERIOR EXTERIOR INTERIOR #10 sNs OR SELF DRILLING, 1 SCREW SHIMM SPACE MAX. #10 WOOD SCREW BACKER ROD IGID FILLER & APPROVE RIGID FILLER RIGID FILLER BACKER RODAPPROVED t & APPROVED1/4" MAX. S AIANT SHIM"PACE MAX. 3E D MIN. INTERIOR SEALANT mw, r SHIM SPACE 1 - EDGE 'STANCE ` _f METAL I WOOD FRAMING STRUCTURE L OR 2X BUCK /�� 1/`* MIN. BY OTHERS 1110 SMS OR BY OTHERS EMBEDMENT h 3/4" MIN SELF DRILLING EDGE DISTANCE SCREWS n VERTICAL CROSS SECTION EXTERIOR 1/2" MIN. METAL STRUCTURE INSTALLATION METAL EDGE DISTANCE STRUCTURE BACKER ROD VERTICAL CROSS SECTION BY OTHERS & APPROVED WOOD FRAMING OR 2X BUCK INSTALLATION SEALANT JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION SIGNED:0610112015 MI WINDOWS AND DOORS \`��51R11i/o�/%i - 1 CARROL TON, TX. 75006D �v\�\G E N,9'. SERIES 185 ALUMINUM FIXED WINDOW 'o,.@�61 NOTES: 73" X 72" NON-IMPACT _ 1.INTERIOR AND EXTERIOR FINISHES,BY OTHERS, FRAME INSTALLATION DETAILS ��, STAY OF � `NOT SHOWN FOR CLARITY. 0 R <4� 2.PERIMETER AND JOINT SEALANT BY OTHERS TO BE oRA•nx; ow0 NO. REV ij,�5,. Q Rl�a:•G\�'�� DESIGNEDINACCORDANCEWITHASTME2112 J.L. DATE 08 SOEE357 A �iipNALtti�\`�` NTS 09/03/14 4.OF 8 REVSIONS - REV DESCR:PTiON - DATE APPROVED 2 1/2' MIN. A REVISED INSTALLATION DETAILS - 06/01/15 R.L. EDGE DISTANCE CONCRETE/f^ASONRY BY OTHERS ; d' 1 1/4' MIN. a 1 _ ty� 4 d '1/4 MIN. EMBEDMENT OPTIONAL 1X BUCK SEE NOTES 3- 7 " 9 a " d.e EMBEDMENT SHEET 1 " -- - J CONCRETE/M.ASONRY BACKER ROD 1/4" MAX. BY OTHERS 1/ ' ;MAX. & APPROVED - SHIM SPACE ° SHI,U SPACE SEALANT ' OPTIONAL 1X BUCK a' RIGID FILLER 7 SEE NOTES' 3 RIGID FILLER SHEET'i" y, 3/16" TAPCON EXTERIOR INTERIOR 3/I b .TAPCON_ a INTERIOR. . BACKER ROD. . 3/16" TAPeON 8t ff APPROVED, RIGID FILLER SEALANT - I ` ' OPTIONAL 1X BUCK SHIM 2-SPACE ° SEE NOTE 3 — 7 . SHEET 1' _ DISTANCE °. EXTERIOR v -' CONCRETE/MASONRY 1 BACKER ROD BY OTHERS " 1 1 4" MIN. APPROVED SEALANT EMBEDMENT : a, a e JAMB INSTALLATION'DETAIL ; .CONCRETEI,MASONRY INSTALLATION . d:, - - 2,e 2 1/2' MIN. EDGE DISTANCE VERTICAL CROSS SECTION CONCRETE/MASONRY INSTALLATION NOTES. 1.INTERIOR AND EXTERIOR FINISHES,BY OTHERS; NOT SHOWN FOR CLARfTY. 2.PERIJETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 SIGNED:0610112015 -MI WINDOWS AND DOORS 0R iLLro�/��� 1001 WEST CROSBY ROAD ��\J�,•'• '�99�i/. 75006 SERIES 185ROALUM N'UMXFIXEO WINDOW *• o,612b1 �► — — ( _ 73" X 72" NON IMPACT .p+ FRAME INSTALLATION DETAILS. ��0• S.TAT OF y� DRAWN!' Owc,1401 REV SCALE NTS DATE 09/03/14 OS 0 E3570F 8 A /��S'IONA j1�a\��\ RLIMICN5 REV DESCUTION DATE APPROVSD A REVISED INSTALLATION DETAILS 06/01/15 R.L. 1 1/1" MIN: 1/4" MAX, EMBEDMENT - `SHIM SPACE l— I/2" RIGID FILLER ri/7." MIN. /4" MIN I EDGE DISTANCE 3 1 MIN. METAL —�� EDGE DISTANCE EDGE DISTANCE WOOD FRAMING I 1 1/4" MIN STRUCTURE � INTERIOR OR 2X BUCK \� _ EMBEDMENT BY.OTHERS _ 1/4" MAX. BY OTHERS SHIM SPACE 10 WOOD I ` / r SCREW �- 1/4" MAX. BACKER ROD &J _ BACKER ROD & SHIM SPACE APPROVED SEALANT ( RIGID FILLER WOOD FRAMING APPROVED SEALANT I BEHIND FLANGE 1 OR 2X BUCK, EXTERIOR' BEHIND FLANGE' t- J RIGID FILLER # 0`SMS OR BY OTHERS '. SELF. DRILLING, BACKER ROD & #.10 WOOD SCREW SCREW APPROVEC SEALANT' BEHIND FLANGE JAMB INSTALLATION DETAIL EXTERIOR WTERIOR WOOD FRAMING OR 2X BUCK INSTALLATION EXTERIOR INTERIOR '#1D SMS OR 1 4" MAX. SELF DRILLING �`. SHIM SPACE SCREW 110 WOOD SCREW BACKER R00 & RIGID FILLER APPROVED SEALANT RIGID FILLER I RIGID FILLER BACKER ROD & BEHIND FLANGE 1/4" MAX APPROVED SEALANT 1/4" VAX. 3/4" MIN. INTERIOR BEHIND FIANCE SHIM SPACE SHIV SPACE EDGE.DISTANCE METAL W000.FR STRUCTURE AMING �1 4 4" BY.OTHERS, 1 OR 2X BUCK, 1 •1/4 MiN: . . BY OTHERS' EMBEDMENT 3/4" MIN #10 SMS.OR EDGE DISTANCE SELF DRILLING 1/2" MIN VERTICAL CROSS SECTION SCREWS EDGE DISTANCE METAL STRUCTCIREINSTALLATION METAL -- EXTERIOR VERTICAL CROSS SECTION STRUCTURE WOOD FRAMING OR 2X BUCK INSTALLATION BY OTHERS BACKER ROD APPROVED SEALANT BEHIND FLANGE _ JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION SIGNED:0610112015 lltulu/Ir MI WINDOWS AND DOORS. �0 4//�� 1001 WEST CR056Y ROAD �J\� -- •• CARROLLTON, TX'75006 ��GENs�;.s i NOTES: SERIES 185 ALUMINUM'FIXED WINDOW oy 51 S INTERIOR AND EXTERIOR FINISHES,BYOTHERS, 73" X 72" NON-IMPACT =p �y NOT SHOWN FOR CLARITY. FLANGE INSTALLATION DETAILS ��0, TAT OF 2.PERIMETER AND JOINT SEALANT BY OTHERS TO BE OMAN: Dn•G NO. RLv i <ORlO DESIGNED IN ACCORDANCE WITH ASTM E2112 U.L. 08-02357. A /ss/0. SCALE NTS D"� 09/03/14 SHEET6 OF 8 �iilllNA�l,`��� ..REVi510N5 RE`! CESCa1PTi0N DATE APPROVED 2 1/2° MIN A REVISED lNSCAUNTION DETAILS, O6/01/15 R.L. EDGE,DISTANCE CONCRETE/MASONRY BY OTHERS ,•.a � ° 1 1/4" MIN EMBEDMENT OPTIONAL 1X BUCK-1: a .,, a e a d .a EMBEDMENT SEE NOTES.3 - 7 SHEET 1 ° �i BACKER ROD & 1/4,: MAX. JI NC CO RETE/MASONRY X. APPROVED SEALANT SHIM SPACE BY OTHERS 1/4 t✓,AC ° I SHIM:SPACE' BEHIND FLANGEOPTIONAL °.Pa I .° a .. RIGID F LLER ENOT 1 X BUCK SEE 3 7 SHEET 1 RIGID FILLER 4. EXTERIOR INTERIOR 3/1s' rAPcory 'INTERIOR BACKER.ROD &. I C T000N APPROVED. SEALANT BEHIND RIGID,FILLER .57< OPTIONAL.I.X BUCK 1/4"`MAX 2 .1/2 SEE NOTE 3 --7, r SHIM, SPACE SHEET 1 I EDGE DisrANcE EXTERIOR r, ° . CONCRETE/MASONRY , . �__^ a b `HACKER ROD & BY.OTHERS a •,e APPROVED SEALANT a <' 1.1/4" MIN. BEHIND.FLANGE d, EMBEDMENT JAMB INSTALLATION DETAIL. a a CCNCRETE/MASONRYINSTALLATION. 2 1/2":MIN. 'EDGE DISTANCE VERTICAL CROSS SECTION CONCRETFJMASCNRY INSTALLATION NOTES: i,lNTERlOAAND EXTERIOR FINISHES,BY OTHERS, . NOT SHOWN FOR,CLARITY, 2.PERIMETER AND JOINT SEALANT BY OTHERS TO,BE - DESIGNED IN ACCORCANCE WITH ASTM E2112 SIGNED:-06/0 i/2015 5 p ii�i�� \ CARROLLTO T 006 ���\\\�,• cENs.49,9�� 1001, WEST CROSBYSROAD i SERIES. Y85 ALUMINUM FIXED WINDOW * 0,.62�* 73" X 72" NON 'IMPACT. FLANGE INSTALLATION. DETAILS ".STAY OF 1y� DROU DWG NO, aev. oORIOP:•G�c���� . SCALE QATE, g8:50EE3S7 A,, NA„ ? :. - .. :. . NTS 09/03/1,4 7 OF 8.. REVISIONS REV DATE A-MVED A REVISED INSTALLATION DETAILS 06/01/15 R.L. APPROVED-� SEALANT BEHIND F114 1 1/1".MIN. . EMBEDMENT #6 WOOD I_ WOOD SCREW ��,\ z FRAMING a</ BY OTHERS UIIi1111UN 1/4".MAX. _r SHIM SPACE WOOD FRAMING 1/4" MAX 7/16" MIN SHI BY OTHERS SHIN SPACE EDGE DISTANCE I #6 WOOD SCREW INTERIOR INTERIOR ' EXTERIOR. 1 1/4" MIN. EMBEDMENT \ 1/4°.:MAX APPROVED - SHIM SPACE SEALANT BEHIND FIN 7/16" MIN' ]^ rmulr J 7/16" ,WIN yl. . EXTERIOR EDGE DISTANCE EDGE DISTANCE. JAMB INSTALLATION DETAIL m 6 WOOD WOOD MI G SCREW FRAMING WOOD FRAN OR 2 X BUCK INSTALLATION APPROVEDJ. 1 1/4" MIN. BY OTHERS . SEALANT EMBEDMENT_ . BEHIND FIN VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION NOTES. . 1.INTERIOR AND EXTERIOR FINISHES,BY OTHERS, NOT SHOWN FOR CLARITY. 2.PERIMETER AND JOINT SEALANT BY OTHERS TO.BE DESIGNED IN.A000RDANCE WITH ASTM E2112 SIGNED:0610112015 MI WINDOWS AND DOORS \\\�I� uL 1001, WEST CROSBY ROAD `\��J\S '• 0'If CARROLLTON, TX 75006 -`v�\.�GENSF`,•• SERIES 185 ALUMINUM FIXED WINDOW e* 0, 6 73" X 72" NON-IMPACT - (n*EtO7� FLANGE INSTALLATION DETAILS - �, TAT OlF ,zz i J L.N. mrc n0. 08-02357 REV � S/CORtO • suEE NTS DATE 09/D3/14 SHEET OF _8 //,//ONAI.1��\\\