HomeMy WebLinkAboutPermit 2010 0550 - 497 S Brocksmith Road.digsigTest Information
Test #Test Location Elevation Reference
Gauge
Make / Model / SN / Calibrated Field Technician
1 Pool deck: Pool Deck on the North Side -1.0 Top of Subgrade CPN / MC-3 / M330907151 / Tech, Port St. Lucie
2 Pool deck: Pool Deck on the West Side -1.0 Top of Subgrade CPN / MC-3 / M330907151 / Tech, Port St. Lucie
3 Pool deck: Pool Deck on the East Side -1.0 Top of Subgrade CPN / MC-3 / M330907151 / Tech, Port St. Lucie
Remarks
Pass: Density Pass
Comments
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
"Backscatter". Gauge calibration data on file with the testing agency.
Test Results
Test #
Retest
Of Test Date Proctor ID Method
Soil
Classification
Optimum
Moisture
(%)
Maximum
Dry
Density (pcf)
In Place
Moisture
(%)
In Place
Dry
Density
(pcf)
In Place
Wet
Density
(pcf)
Probe
Depth
(in)
Percent
Compaction
Min Comp.
(%)Remark
1 3/23/21 21-064
(Modified)
A --11.5 106.0 7.8 101.1 109.0 12 95 95 Pass
2 3/23/21 21-064
(Modified)
A --11.5 106.0 11.4 100.6 112.1 12 95 95 Pass
3 3/23/21 21-064
(Modified)
A --11.5 106.0 12.0 100.3 112.3 12 95 95 Pass
AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF
THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDING
OUR WRITTEN APPROVAL.
Page 1 of 1
In-Place Density Report
Test Method: ASTM D6938
Permit Number: 2010 0550
Report Date: 3/26/2021
Client:
Cole Construction
Santa Rosa Beach, FL 32459
3295 W. County Highway 30A F
Project:
497 S Brocksmith Rd
113-21-64-5446
Fort Pierce, FL 34945
497 S Brocksmith Rd
Florida Registration No. 5950
460 NW Concourse Place, Unit 1
Port St. Lucie, FL 34986
Phone: 772-878-0072
Port St. Lucie Branch
3/26/21