HomeMy WebLinkAboutCertification for Design Load ComplianceL'J e = Planning & Development Services Department
6 o ��V W� Building &Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 3.4982 — (772) 462-1553
Certification for Design Load Compliance
Project Name: LABARBIERA RESIDENCE
Project Address: LOT 35 DIAMOND SANDS JENSEN BEACH, FLORIDA
Permit #: Occupancy Type: R-3 Construction Type: V-B
INSTRUCTIONS FOR USE:
a This certification must be completed, signed, and sealed by the design professional of record.
o Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official.. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida X Code 2010 Edition with 20 X Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed Partially Enclosed Open
3. Risk Category: _I X II ' III IV Exposure Category: B C X D
4. Design Wind Velocity 17;0 mph ASD X LRFD End Zone Width: 5 ft
40'MRH S. Mean'Roof Height 400' ft Roof Pitch: 7 :12 Parapet: N/A ft
170MPH"'**�
6. Components &Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'{VIRH, clearly label on all plan openings):
ALL ZONES 57/+53
DESIGNED AS Zone 1: Zone 2: / Zone 3:-69/+21 Zone 4:-71/+53 Zone 5: - Garage:-55/+45
ZONE 3 . Design Loads: Floor: 40LL PSF Roof/Dead: 25 PSF Roof/Live: 30 Balcony: 50LL PSF
Dock: N/A PSF Deck: 50LL PSF Stairs: 50LL PSF Fence: N/A PSF Railings: N/A PSF (BY OTHERS)
8. Were Shear Wails Considered ,For Structure? X Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: NONE PSF Soil Test Reports Submitted? XYes (FOUNDATION ON
PILINGS)
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depictedon these plans provide adequate resistance to the design
forces specified:
ANDALL E. STOFFT FL-0011105
rame Cert.# & Co. Cert Aufh.
RANDALL STOFFT ARCHITECTS
Signature; Date, and Seal
42 N. SWINTON AVENUE SUITE #1 DELRAY BEACH, FL. 33444
JUL 25 ZU14 Company Name & Address
SLCCDV Form # 020-12 Revised 3/15/12 (1S)