Loading...
HomeMy WebLinkAboutLetter; Reportd from Nutting & Pile LogAgsten Engineering, Inc. 3000 Florida Blvd, Suite 206 Delray Beach, FL 33483 (561) 272-5012 (561)243-6,401 fax January 13, 2015 Mr. Ed Roseberry St. Lucie County Building Dept. 2300 Virginia Ave. Ft. Pierce, FL 34928 RE: LaBarbiera, Lot 35, Diamond Sands, Port St. Lucie, FL Dear Ed: I have reviwed the reports from Nutting and the pile log. In my opinion, the calling out for a 14" f diameter pile is a typo (first page), and the log clearly shows all to be 16" diameter. So, we are OK. Please call if you have any questions or need additional information �' ouily; Z Robert E. Austen Ili, P.E. President PE 43205 EB 8340 a Our client for this project was: Mr. Rich Barnes Bodax Foundations, Inc. 1101 NW 55t' Street Ft. Lauderdale, Florida 33309' The contents of this report are for the exclusive use of the client, the client's design & construction team and governmental authorities for this specific project exclusively. Information conveyed in this report shall not be used or relied upon by other parties or for other projects without the expressed written consent of NE. We appreciate this opportunity, to work with you on this project and look forward to completing this and future projects with you. Should you have any questions or if we can be of any further assistance, please contact us at your convenience. v� Respectfully Submitted, NUTTING ENGINEERS OF FLORIDA, INC. r� i1 w '^� 1.',. h ��f %' Richard C. Wohlfarth, P.E. Director of Engineering Attachments: Pile Location Plans Pile Installation ,Data LTR BODAX 8224 S-OCN DR JENSEN ACP CEG r,t,Ff ti.4r,*.vra aK+, Fri»?' 45` If.�; 91k kr"r 01 o�,elc;T.E. f96994>7i, ,, Engineer-` o= V L4 . P`�PO•IOg4.6m6. �L C r 1310 �eptune Drive ��® !V-V � �. /i V/_ �i� Boynton Beach, Florida 33426 � � V (/ c� / 561-7�36-4900 EngFW ineers Toll Flee: 877-NUTTING (688-8464) Fax:561-737-9975 BrowlIrd 954-941-8700 of Florida Inc. I Established 1967 St. Lucie 772-408-1050 Miami -Dade 305-557-3083 '�ZlmvYour Project is Our Commitment www.nuttingengineers.com Ln U October 22, 2014 Ln Mr. Rich Barnes Bodax Foundations, Inc. a 1101 NW 55tI' Street c Ft. Lauderdale, Florida 33309 0 L Subject: Report of Augercast Pile Installation Monitoring "' Proposed Labarbier-a residence Ul 8224 South Ocean Drive ° Jensen Beach, Florida U v U Dear Mr. Barnes: c -� Nutting Engineers of Florida, Inc. (NE) has completed observation of augercast piling operations M a, for the proposed residence at,the subject site. Bodax Foundations, Inc. installed cast -in -place augured piles for support of the proposed construction. a, a; Bodax Foundations, Inc. installed a total of 84, 16-inch diameter augercast piles for the project. The piles were installed from October 15, 2014 to October 21, 2014. The pile size and depth v recommendations were based upon a Report of Geotechriical Exploration prepared by GFA E International dated September i18, 2014. c W The pile installation characteristics of each pile are presented in the attached Pile Installation Data. Identification of each i pile location followed by the pile number is shown on the Pile °J Location Plans attached. Each pile record in the attached summary tables shows the following f6 information: c ; E3 RECORD NUMBER IN CHRONOLOGICAL ORDER i o THE PILE NUMBER (AS FOUND ON ATTACHED PLANS) 4-1 o THE DIAMETER OF THE PILE o v THE LENGTH OF PILE FROM GROUND SURFACE TO TIP U o THE THEORETICAL VOLUME OF GROUT FOR THE PILE THE NUMBER OF PUMP STROKES FOR THE PILE THE ACTUAL VOLUME OF GROUT FOR THE PILE THE GROUT FACTOR THE DATE OF INSTALLATION o THE REINFORCEMENT TYPES AND GENERAL COMMENTS AS NEEDED OFFICES Palm Beach Miami -Dade 1 St. Lucie The drilling operations were in;onitored in the field by our field engineer and inspector in order to approximately determine the type of material being penetrated. This identification was done based on the augering time, the materials received during the drilling operations and the relative hardness of the soils/rocks as indicated by the vibration or "chattering" of the hydraulic lines. The augercast piles were installed to depths of twenty-two to twenty-eight feet below the existing ground surface. The piles were designed for an allowable compressive capacity of 30 tons as required by the structural specifications and the recommendations made in the geotechnical report. Generally, during the installation of the piles, easy drilling was observed from the ground level to approximately seventeen feet. Below this depth range medium hard drilling was encountered to the final tip depth. All piles that encountered refusal conditions (depths less than 28 feet) were observed to be drilled at least three to five feet into the hard limestone formation. All house piles received a steel cage consisting of six #7 reinforcing steel bars with #3 ties spaced 12- inches on center the full length of the pile as stated in the structural specifications. All pool piles received a steel cage consisting of four #5 reinforcing steel bars with #3 ties spaced 12-inches on center the full length of the pile as stated in the structural specifications. We note that pool piles numbered 1 through 9 were battered as stated in the construction documents. We also note that on October 15, 2014, during installation of pile #4, the batter angle of the pile resulted in the pile to breach into pile number 30 which was installed earlier in the day. Pile #4 was reinstalled without errors on October 17, 2014. Because of the breach, the initial pile #30 location was eliminated and relocated 4 feet towards pile #36. To compensate the relocation piles numbered #84 and #85 were added to the project. We also note that pile 453 was omitted by the onsite general contractor and was therefore not installed. Upon completion of this inspection process, and review of the recorded data, it is our opinion that the augercast piles for the house and pool attained the required design compressive capacity of 30 tons. The piles that were presently installed were constructed in substantial compliance with the plans and specifications. We note that it was monitored and ensured that the piles began installation at the survey locations provided in the field. If during drilling operations it was discovered that gross deviations from original locations have occurred, the deviation was attempted to be rectified. Nutting Engineers is not responsible for minor deviations which have occurred during drilling operations, along with incorrect surveyed pile (locations during piling installation. We also note that some deviations may be due to the augerdrill shifting when attempting to drill through the hard rock or other encountered debris conditions. This condition is beyond the control of the site inspector and undersigned engineer. t .,,, of • • . EODAX FOUNDATIONS Proposed Labarbiera Residence 8224 South Ocean Drive Jensen Beach, Florida PILE LOG DATA OF AUGERCAST PILE INSTALLATION NUTTING ENGINEERS OF FLORIDA, INC. ` Recortl y Plc K ,Pilo Mo a • f• P116 Dia k din). Plle „ Length Theoretic Pile !/tiolumel. ; Pump r yStrokesr Uolume?'of Grout Pumpedr •• Grout i Factor Date Installed `� Remarks 1 68 16.0 28 1 39.1 58 47.6 1.22 10/15/14 2 78 16.0 28 39.1 57 46.7 1.20 10/15/14 3 37 16.0 28 39.1 59 48.4 1.24 10/15/14 4 36 16.0 28j 39.1 75 61.5 1.57 10/15/14 Redrill 5 30 16.0 28, 39.1 113 92.7 2.37 10/15/14 Relocated 10/16 6 6 16.0 28- 39.1 68 55.8 1.43 10/15/14 Pool 7 5 16.0 28 39.1 68 55.8 1.43 10/15/14 Pool 8 4 16.0 28 39.1 62 50.8 1.30 10/15/14 Pool/Redrilled 10/17 9 10 16.0 28! 39.1 65 53.3 1.36 10/15/14 Pool 10 41 16.0 28; 39.1 63 51.7 1.32 10/15/14 11 35 16.0 28 39.1 58 47.6 1.22 10/15/14 12 34 16.0 28 39.1 59 48.4 1.24 10/15/14 13 43 16.0 28 39.1 70 57.4 1.47 10/15/14 14 42 16.0 28 39.1 61 50.0 1.28 10/15/14 15 16.0 28 39.1 57 46.7 1.20 10/15/14 16+-19 18 16.0 28 39.1 64 52.5 1.34 10/15/14 17 45 16.0 28 39.1 60 49.2 1.26 10/16/14 18 44 16.0 28 39.1 62 50.8 1.30 10/16/14 19 74 16.0 28: 39.1 65 53.3 1.36 10/16/14 20 20 16.0 28. 39.1 59 48.4 1.24 10/16/14 21 17 16.0 28 39.1 61 50.0 1.28 10/16/14 22 16 16.0 28 39.1 62 50.8 1.30 10/16/14 23 15 16.0 28 39.1 59 48.4 1.24 10/16/14 24 14 16.0 281 39.1 94 77.1 1.97 10/16/14 Redrill 25 12 16.0 28; 39.1 95 77.9 1.99 10/16/14 Redrill 26 11 16.0 28' 39.1 113 92.7 2.37 10/16/14 Redrill 27 13 16.0 28 39.1 59 48.4 1.24 10/16/14 28 21 16.0 28 39.1 72 59.0 1.51 10/16/14 29 26 16.0 28 39.1 62 50.8 1.30 10/16/14 30 85 16.0 22- 30.7 58 47.6 1.55 10/16/14 Xtra Pile 31 84 16.0 28: 39.1 61 50.0 1.28 10/16/14 Xtra Pile 32 31 16.0 28 39.1 58 47.6 1.22 10/16/14 33 32 16.0 28 39.1 59 48.4 1.24 10/16/14 34 33 16.0 28 39.1 69 56.6 1.45 10/16/14 35 27 16.0 28 39.1 66 54.1 1.38 10/16/14 36 25 16.0 28 39.1 59 48.4 1.24 10/16/14 37 29 16.0 28 39.1 63 51.7 1.32 10/16/14 38 28 16.0 28 39.1 102 83.6 2.14 10/16/14 Redrill 39 67 16.0 28 39.1 64 52.5 1.34 10/16/14 40 70 16.0 28 39.1 57 46.7 1.20 10/16/14 41 72 16.0 28 39.1 65 53.3 . 1.36 10/16/14 44 3 b.0 28 39.1 72 59.0 1.51 10/17/14 Pool 4 2 28 39.1 63 51.7 1.32 10/17/14 Pool 1 , Q 39.1 112 91.8 2.35 10/17/14 Pool/Redrill 4 _ , A 39.1 62 50.8 1.30 10/17/14 Pool 6 8 of FIc rida IW.• stal,lishe25967 39.1 68 55.8 1.43 10/17/14 Pool ` BODAX FOUNDATIONS Proposed LobarbienaResidence 8224South Ocean Drive Jensen Beach, Florida PILE LOG DATA OF AUGERCASTPILE INSTALLATION Far. r 58 83 16.0 28 39.1+ 68 55.8 1.43 10/17/14 I ofal unear feet drilled 232y) I ofal Grout VOL. kYQ-)l 10 Pool Piles #1-9 were Battered. Pile #53 omitted from Installation. Installation of Pile #4 Breached Pile #30 on 10/15. Piles relocated and Redrilled as noted. Minimum depth drilled 22 Maximum depth drilled 28 Piles A14 and M36 added due to breaGn.