MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA)
www.miamidade.gov/economy
DaV;iLe,�:Roofscape�; II LC
1413 Osage Ave.
Kansas City, KS 66105
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION Bellaforte Slate arid:Bellaforte Sliake
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety. I
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This revises NOA #11-0401.11 and consists of pages 1 through 9.
The submitted documentation was reviewed by Alex Tigera.
NOA No. 12-0831.01
ruaru•oanE couNrr Expiration Date: 12/16/14
Approval Date: 02/14/13
Page 1 of 9
MALL E. STOFFT ARCHUECT,% PIM
AP9 AMDAW
PROVED REVISE & RE S
[] APPROVED AS CORRECTED REJECTED
This revi&N is only for general conformance with the design concept of the
Projact and general compliance with the information given in the coittr-zrt
dvcUrnEnts. Co.-,, ec!aons or comments made on ti;e shop dr :',:g„luring
IN-, revia;v do not relieve L' a coAractor from compliance with the require-
n:^:n;s Of the plans and specifac-a-Lions. Approval of a specific item shall not
inc"ode as royal of an assembly of which the item is a componept. Con-
tracti-r is resporsib e for. Dimensions to be confirmed and co, � elated at the
job 8;1e; Information that pertains solely to the fabrication processes or to
q:a means, meS!ods, techniquas, sequences and procedures of construc-
tion: coordinatica of the work of all other trades: and for performing all work
in a safe and satisfactory manner.
aa>F �° A. 1 BY,
NIIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA)
www.miamidade.gov/economv
DaVinci Roofscapes, LLC
1413 Osage Ave.,
Kansas City, KS 66105
SCOPE:
This NOA is being issued under the applicable rules and regulations governing'the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have -this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revolve this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code. '
This product is approved as described herein, and has been designed to comply iwith the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Bellafort6 Slate and Bellafort6 Shake
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the' manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This revises NOA #11-0401.11 and consists of pages 1 through 9.
The submitted documentation was reviewed by Alex Tigera.
QMIAMMI-D�ADECO=UNTY
NOA No. 12-0831.01
Expiration Date: 12/16/14
Approval Date: 02/14/13
Page 1 of 9
ROOFING ASSEMBLY APPROVAL
Category:
Roofing
Sub -Category:
Slate
Materials
Composite
Deck Type:
Wood
Maximum Design Pressure
—80 psf
Fire Classification Pressure
See General Limitation #1
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Product
Dimensions
Test Product Description
Specifications
i
Bellafort6 Slate
IS- 1/2" long
TAS 110 Synthetic Self -Aligning Slate
11-1/2" width
Bellafort6 Shake
15-1/2" —16" long
TAS 110 Synthetic Self -Aligning Shake
12" width
Starter Slate
12-1/4" x 3-1/2"
TAS 110 Starter Slate for use with Synthetic
Self -Aligning Slate
Starter Shake
12-1/4" x 3-1/2"
TAS 110 Starter Shake for use with Synthetic
Self -Aligning Shake
MANUFACTURING LOCATION:
1. Kansas City, KS
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Report Date
PRI Asphalt Technologies
DRM-017-02-01
TAS 100 08/27/09
DRM-034-02-01
TAS 100 06/20/ 12
DRM-025-02-01
'TAS 125 06/20/12
DRM-037-02-01
'TAS 100 08/07/12
DRM-035-02-01
TAS 125 06/18/12
DRM-001-02-01
ASTM G26 09/29/04
lntertek ETL Semko
3169679COQ-033
TAS 125 08/28/09
3087829
ASTM D 2843 01/25/06
3061879(d)
ASTM D1929 01/25/06
3061879(b)
ASTM D635 09/21/05
QAI Laboratories
RJ 1956-F
ASTM E 108 . 06/18/12
I
I
NOA No. 12-0831.01 '
MiaMi•pApe couivrt
Expiration Date: 12/16/14
Approval Date: 02/14/13
Page 2 of 9
APPROVED ASSEMBLIES:
System A: Bellaforte Slate
Deck Type: Wood, Non -Insulated
Deck Description: � 9/32" or greater.plywood or wood plank.
Y
Slope Range: 4": 12" or greater
Maximum Uplift -65 psf (See General Limitation #2)
Pressure:
Deck Attachment: In accordance with applicable Building Code, but in no case shall it be less than 8d annular
ring shank nails spaced 6" o.c. In reroofing, where ,the deck is less than 19/32" thick
(Minimum 15/32") The above attachment method must be in addition to existing attachment.
Underlayment: Underlayment shall be applied in accordance with applicable Building Code. One layer of
ASTM D 226 Type 11 felt overlapped 19" and 6" end lap. Underlayment shall be installed
with minimum 12 ga. corrosion resistant ring shank' nails and tin caps, spaced 12" o.c.
staggered in the field and 6" o.c. at the laps. Or, any approved underlayment having a
current NOA.
Fire Barrier: Any approved fire barrier having a current NOA. Refer to a current fire directory listing
for fire ratings of this roofing system assembly as well as the location of the fire barrier
within the assembly. See Limitation # 1.
Valleys: Valley metal shall be a minimum 16" wide. Valley metal shall be set over a minimum 36"
wide sweat sheet of minimum ASTM D 226 type H embedded in roofing cement, or an
approved self -adhered membrane. Valley metal shall imbedded in roofing cement and be
secure with roofing nails spaced a maximum 4" ox ai outer most part of metal on each
side. Valley edges shall be primed and embed a 6" wide asphalt coated fabric in an 8"
wide bed of roofing cement. Place a second coat oflroofing cement over the fabric. Valley
detail shall be in accordance with the current published manufacturer's literature.
Ridge & Hips: See Da Vinci Roofscape's published installation manual for detail.
Starter: Install required starter over the edge a 3/4". Fasten each starter with a minimum of two
corrosion resistant 12 gauge ring shank roofing nails located 2-1/2" up from butt edge and
3/a" in from each end. Nails shall be of sufficient length to penetrate sheathing 3/16".
Metal Panels and Bellaforte Slate shall be installed in accordance with DaVinci Roofscapes, LLC's current
Accessories: published installation manual. Bellaforte Slate shalll have a maximum 12" exposure (see'
Detail `B').
The first course of the Slate should begin on the tab first then on top of the tile in the left
hand corner. It may be necessary to lift the edge of the left hand tile to insert the valley of
the installed tile underneath. Bellaforte Slate shall be fastened with five (5) 0.120" x 1-
3/4" long stainless steel ring shank nails. Four (4) tl4rough the holes locations imprinted on
the slate (see Detail `A') and one(1) through the side tab".
NOA No. 12-0831.01
Expiration Date: 12/16/14
Approval Date: 02/14/13
Page 3 of 9
System B:
Bellaforte Shake
Deck Type:
Wood, Non -Insulated
Deck Description:
19/32" or greater plywood or wood plank.
Slope Range:
4": 12" or greater
Maximum Uplift
-80 psf (See General Limitation #2)
Pressure:
Deck Attachment:
In accordance with applicable Building Code, but in no case shall it be less than 8d annular
ring shank nails spaced 6" o.c. In reroofing, where the deck is less than 19/32" thick
(Minimum 15/32") The above attachment method must be in addition to existing attachment.
Underlayment:
Underlayment shall be applied in accordance with applicable Building Code. One layer of
ASTM D 226 Type II felt overlapped 19" and 6" end lap. Underlayment shall be installed
with minimum 12 ga. corrosion resistant ring shank nails and tin caps, spaced 12" o.c.
staggered in the field and 6" o.c. at the laps. Or, any approved underlayment having a
current NOA.
Fire Barrier:
Any approved fire barrier having a current NOA. Refer to'a current fire directory listing
for fire ratings of this roofing system assembly as well as the location of the fire barrier
within the assembly. See Limitation # 1.
Valleys:
Valley metal shall be a minimum 16" wide. Valley metal shall be set over a minimum 36"
wide sweat sheet of minimum ASTM D 226 type 11 embedded in -roofing cement, or an
approved self -adhered membrane. Valley metal shall imbedded in roofing cement and be
secure with roofing nails spaced a maximum 4" o.c.- at outer most part of metal on each
side. Valley edges shall be primed and embed a 6" wide asphalt coated fabric in an 8"
wide bed of roofing cement. Place a second coat of roofing cement over the fabric. Valley
detail shall be in accordance with the current published manufacturer's literature.
Ridge & Hips:
See Da Vinci Roofscape's published installation manual for detail.
Starter:
Install required starter over the edge a 3/4". Fasten each starter with a minimum of two
corrosion resistant 12 gauge ring shank roofing nails located 2-1/2" up from butt edge and
%" in from each end. Nails shall be of sufficient length to penetrate sheathing 3/16".
Metal Panels and
Bellafort6 Shake shall be installed in accordance with DaVinci Roofscapes, LLC's current
Accessories:
published installation manual. Bellafort6 Shake shall have a maximum 12" exposure (see
Detail `D').
The first course of the Shake should begin on the tab first then on top of the tile in the left
hand corner. It may be necessary to lift the edge of the left hand tile to insert the valley of
the installed tile underneath. Bellafort6 Shake shall be fastened with five (5) 0.120" x 1-
3/4" long stainless steel ring shank nails. Four (4) through the holes locations imprinted on
the slate (see Detail 'Cl) and one(1) through the side tab
NOA No. 12-0831.01
Expiration Date: 12/16/14
Approval Date: 02/14/13
Page 4 of 9
GENERAL LIMITATIONS:
l . Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field,
perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening
at enhanced pressure zones (i.e. perimeters, extended corners and corners).
3. All panels shall be permanently labeled with the manufacturer's name and/or logo, and the following
statement: "Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control
Seal as seen below.
QM[I•DADE COUNTY
4. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 9N-3 of the Florida Administrative Code.
NOA No. 12-0831.01
Expiration Date: 12/16/14
Approval Date: 02/14/13
Page 5 of 9
DRAWINGS
DETAIL A
BELLAFORTE SLATE
I
12.75"
NOA No. 12-0831.01
Expiration Date: 12/16/14
Approval Date: 02/14/13
Page 6 of 9
DETAIL `B'
BELLAFORTE SLATE
LAYOUT
NOA No. 12-0831.01
Expiration Date: 12/16/14
Approval Date: 02/14/13
Page 7 of 9
DRAWINGS
DETAIL C
BELLAFORTE SHAKE
12.75"
NOA No. 12-0831.01
Expiration Date: 12/16/14
Approval Date: 02/14/13
Page 8 of 9
DRAWINGS
DETAIL `D'
BELLAFORTE SHAKE
LAYOUT
END OF THIS ACCEPTANCE
NOA No. 12-0831.01
Expiration Date: 12/16/14
Approval Date: 02/14/13
Page 9 of 9