Loading...
HomeMy WebLinkAboutNOA; Bellaforte Slate & Bellaforte ShaketN CM1 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy DaV;iLe,�:Roofscape�; II LC 1413 Osage Ave. Kansas City, KS 66105 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION Bellaforte Slate arid:Bellaforte Sliake LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. I INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA #11-0401.11 and consists of pages 1 through 9. The submitted documentation was reviewed by Alex Tigera. NOA No. 12-0831.01 ruaru•oanE couNrr Expiration Date: 12/16/14 Approval Date: 02/14/13 Page 1 of 9 MALL E. STOFFT ARCHUECT,% PIM AP9 AMDAW PROVED REVISE & RE S [] APPROVED AS CORRECTED REJECTED This revi&N is only for general conformance with the design concept of the Projact and general compliance with the information given in the coittr-zrt dvcUrnEnts. Co.-,, ec!aons or comments made on ti;e shop dr :',:g„luring IN-, revia;v do not relieve L' a coAractor from compliance with the require- n:^:n;s Of the plans and specifac-a-Lions. Approval of a specific item shall not inc"ode as royal of an assembly of which the item is a componept. Con- tracti-r is resporsib e for. Dimensions to be confirmed and co, � elated at the job 8;1e; Information that pertains solely to the fabrication processes or to q:a means, meS!ods, techniquas, sequences and procedures of construc- tion: coordinatica of the work of all other trades: and for performing all work in a safe and satisfactory manner. aa>F �° A. 1 BY, NIIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economv DaVinci Roofscapes, LLC 1413 Osage Ave., Kansas City, KS 66105 SCOPE: This NOA is being issued under the applicable rules and regulations governing'the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have -this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revolve this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. ' This product is approved as described herein, and has been designed to comply iwith the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Bellafort6 Slate and Bellafort6 Shake LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the' manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA #11-0401.11 and consists of pages 1 through 9. The submitted documentation was reviewed by Alex Tigera. QMIAMMI-D�ADECO=UNTY NOA No. 12-0831.01 Expiration Date: 12/16/14 Approval Date: 02/14/13 Page 1 of 9 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Slate Materials Composite Deck Type: Wood Maximum Design Pressure —80 psf Fire Classification Pressure See General Limitation #1 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product Dimensions Test Product Description Specifications i Bellafort6 Slate IS- 1/2" long TAS 110 Synthetic Self -Aligning Slate 11-1/2" width Bellafort6 Shake 15-1/2" —16" long TAS 110 Synthetic Self -Aligning Shake 12" width Starter Slate 12-1/4" x 3-1/2" TAS 110 Starter Slate for use with Synthetic Self -Aligning Slate Starter Shake 12-1/4" x 3-1/2" TAS 110 Starter Shake for use with Synthetic Self -Aligning Shake MANUFACTURING LOCATION: 1. Kansas City, KS EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date PRI Asphalt Technologies DRM-017-02-01 TAS 100 08/27/09 DRM-034-02-01 TAS 100 06/20/ 12 DRM-025-02-01 'TAS 125 06/20/12 DRM-037-02-01 'TAS 100 08/07/12 DRM-035-02-01 TAS 125 06/18/12 DRM-001-02-01 ASTM G26 09/29/04 lntertek ETL Semko 3169679COQ-033 TAS 125 08/28/09 3087829 ASTM D 2843 01/25/06 3061879(d) ASTM D1929 01/25/06 3061879(b) ASTM D635 09/21/05 QAI Laboratories RJ 1956-F ASTM E 108 . 06/18/12 I I NOA No. 12-0831.01 ' MiaMi•pApe couivrt Expiration Date: 12/16/14 Approval Date: 02/14/13 Page 2 of 9 APPROVED ASSEMBLIES: System A: Bellaforte Slate Deck Type: Wood, Non -Insulated Deck Description: � 9/32" or greater.plywood or wood plank. Y Slope Range: 4": 12" or greater Maximum Uplift -65 psf (See General Limitation #2) Pressure: Deck Attachment: In accordance with applicable Building Code, but in no case shall it be less than 8d annular ring shank nails spaced 6" o.c. In reroofing, where ,the deck is less than 19/32" thick (Minimum 15/32") The above attachment method must be in addition to existing attachment. Underlayment: Underlayment shall be applied in accordance with applicable Building Code. One layer of ASTM D 226 Type 11 felt overlapped 19" and 6" end lap. Underlayment shall be installed with minimum 12 ga. corrosion resistant ring shank' nails and tin caps, spaced 12" o.c. staggered in the field and 6" o.c. at the laps. Or, any approved underlayment having a current NOA. Fire Barrier: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation # 1. Valleys: Valley metal shall be a minimum 16" wide. Valley metal shall be set over a minimum 36" wide sweat sheet of minimum ASTM D 226 type H embedded in roofing cement, or an approved self -adhered membrane. Valley metal shall imbedded in roofing cement and be secure with roofing nails spaced a maximum 4" ox ai outer most part of metal on each side. Valley edges shall be primed and embed a 6" wide asphalt coated fabric in an 8" wide bed of roofing cement. Place a second coat oflroofing cement over the fabric. Valley detail shall be in accordance with the current published manufacturer's literature. Ridge & Hips: See Da Vinci Roofscape's published installation manual for detail. Starter: Install required starter over the edge a 3/4". Fasten each starter with a minimum of two corrosion resistant 12 gauge ring shank roofing nails located 2-1/2" up from butt edge and 3/a" in from each end. Nails shall be of sufficient length to penetrate sheathing 3/16". Metal Panels and Bellaforte Slate shall be installed in accordance with DaVinci Roofscapes, LLC's current Accessories: published installation manual. Bellaforte Slate shalll have a maximum 12" exposure (see' Detail `B'). The first course of the Slate should begin on the tab first then on top of the tile in the left hand corner. It may be necessary to lift the edge of the left hand tile to insert the valley of the installed tile underneath. Bellaforte Slate shall be fastened with five (5) 0.120" x 1- 3/4" long stainless steel ring shank nails. Four (4) tl4rough the holes locations imprinted on the slate (see Detail `A') and one(1) through the side tab". NOA No. 12-0831.01 Expiration Date: 12/16/14 Approval Date: 02/14/13 Page 3 of 9 System B: Bellaforte Shake Deck Type: Wood, Non -Insulated Deck Description: 19/32" or greater plywood or wood plank. Slope Range: 4": 12" or greater Maximum Uplift -80 psf (See General Limitation #2) Pressure: Deck Attachment: In accordance with applicable Building Code, but in no case shall it be less than 8d annular ring shank nails spaced 6" o.c. In reroofing, where the deck is less than 19/32" thick (Minimum 15/32") The above attachment method must be in addition to existing attachment. Underlayment: Underlayment shall be applied in accordance with applicable Building Code. One layer of ASTM D 226 Type II felt overlapped 19" and 6" end lap. Underlayment shall be installed with minimum 12 ga. corrosion resistant ring shank nails and tin caps, spaced 12" o.c. staggered in the field and 6" o.c. at the laps. Or, any approved underlayment having a current NOA. Fire Barrier: Any approved fire barrier having a current NOA. Refer to'a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation # 1. Valleys: Valley metal shall be a minimum 16" wide. Valley metal shall be set over a minimum 36" wide sweat sheet of minimum ASTM D 226 type 11 embedded in -roofing cement, or an approved self -adhered membrane. Valley metal shall imbedded in roofing cement and be secure with roofing nails spaced a maximum 4" o.c.- at outer most part of metal on each side. Valley edges shall be primed and embed a 6" wide asphalt coated fabric in an 8" wide bed of roofing cement. Place a second coat of roofing cement over the fabric. Valley detail shall be in accordance with the current published manufacturer's literature. Ridge & Hips: See Da Vinci Roofscape's published installation manual for detail. Starter: Install required starter over the edge a 3/4". Fasten each starter with a minimum of two corrosion resistant 12 gauge ring shank roofing nails located 2-1/2" up from butt edge and %" in from each end. Nails shall be of sufficient length to penetrate sheathing 3/16". Metal Panels and Bellafort6 Shake shall be installed in accordance with DaVinci Roofscapes, LLC's current Accessories: published installation manual. Bellafort6 Shake shall have a maximum 12" exposure (see Detail `D'). The first course of the Shake should begin on the tab first then on top of the tile in the left hand corner. It may be necessary to lift the edge of the left hand tile to insert the valley of the installed tile underneath. Bellafort6 Shake shall be fastened with five (5) 0.120" x 1- 3/4" long stainless steel ring shank nails. Four (4) through the holes locations imprinted on the slate (see Detail 'Cl) and one(1) through the side tab NOA No. 12-0831.01 Expiration Date: 12/16/14 Approval Date: 02/14/13 Page 4 of 9 GENERAL LIMITATIONS: l . Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). 3. All panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement: "Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control Seal as seen below. QM[I•DADE COUNTY 4. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. NOA No. 12-0831.01 Expiration Date: 12/16/14 Approval Date: 02/14/13 Page 5 of 9 DRAWINGS DETAIL A BELLAFORTE SLATE I 12.75" NOA No. 12-0831.01 Expiration Date: 12/16/14 Approval Date: 02/14/13 Page 6 of 9 DETAIL `B' BELLAFORTE SLATE LAYOUT NOA No. 12-0831.01 Expiration Date: 12/16/14 Approval Date: 02/14/13 Page 7 of 9 DRAWINGS DETAIL C BELLAFORTE SHAKE 12.75" NOA No. 12-0831.01 Expiration Date: 12/16/14 Approval Date: 02/14/13 Page 8 of 9 DRAWINGS DETAIL `D' BELLAFORTE SHAKE LAYOUT END OF THIS ACCEPTANCE NOA No. 12-0831.01 Expiration Date: 12/16/14 Approval Date: 02/14/13 Page 9 of 9