Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Evaluation Report
�EYWj;fj'cLjJF&Rt98%n No. 29824 CREEK ���PLYA ur 3 g Drive3647 S . LUCIE C®UN 480-3421 TECHNICAL SERVICES, LLC B®CP TM EVALUATION REPORT FLORIDA BUILDING ODE,7 EDITION(2020) I Manufacturer: MID-STATES ASPHALT AND CANT STRIP, INC. Issued October 16, 2020 1637 515t Street I Tuscaloosa,AL 35401 j (800)489-2391 www.msaroof.com RI.,CEIVED Manufacturing Location: Tuscaloosa,AL j Ffle ®p MAR 2 5 2021 Quality Assurance: UL LLC(QUA9625) ST. Lucie County, Permitting SCOPE �I Category: Roofing Subcategory: Underlayments Code Sections: 1504.3.1, 1507.1.1 Properties: Physical properties REFERENCES f Entity Report No. i Standard Year PRI Construction Materials Technologies(TST5878) BWR-514-02-01 I ASTM D 1970 2015a PRI Construction Materials Technologies(TST5878) BWR-522-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST5878) BWR-534-02-01 I ASTM D 1970 2015a ASTM D 4798 2011(2016) PRI Construction Materials Technologies(TST5878) BWR-543-02-01 I ASTM D 1970 2015a PRI Construction Materials Technologies(TST5878) WRMI-011-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST5878) MSA-004-02-01 { ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) MSA-007-02-01 UL 1897 2012 PRI Construction Materials Technologies(TST6049) MSA-026-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) MSA-047-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) MSA-048-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) MSA-054-02-01.1 TAS 103 2020 ` TAS 110 2000 PRI Construction Materials Technologies(TST6049) MSA-056-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) MSA-057-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) MSA-060-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) MSA-060-02-02 TAS 110 2000 PRI Construction Materials Technologies(TST6049) MSA-062-02-01 ASTM D 1623 2017 PRI Construction Materials Technologies(TST6049) 1085T0002 TAS 110 2000 PRI Construction Materials Technologies(TST6049) 1085T0007 ASTM D 1623 2017 PRI Construction Materials Technologies(TST6049) 1085TOol l ASTM D 1623 2017 I TAS 103 2020 I I I III 1 IIIII MSA17001.2 FL17401-R5 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. I fI i MID-STATES ASPHALT AND CANT STRIP,INC CREEKSelf-Adhering Underlayments TECHNICAL SERVICES, LLC i PRODUCT DESCRIPTION AND LIMITS OF USE I QUIK-Stick Ice&Water QUIK-Stick Ice & Water Granular is an }ASTM D 1970 self-adhesive underlayment I j Granular constructed from SBS modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-it and has a nominal thickness of 50 mils. QUIK-Stick Ice&Water Granular is permitted to be used as prescribed in FBC Section 1507.1.1 and Table 1507.1.1.1 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. QUIK-Stick Ice&Water QUIK-Stick Ice & Water Sand is an ASTM D 1970 self-adhesive underlayment Sand constructed from SBS modified asphalt with a fiberglass mat reinforcement and surfaced with sand. The product is supplied in 2-sq.Trolls with nominal dimensions of 3-ft x 66.8-ft i and has a nominal thickness of 50 mils. i i ' I QUIK-Stick Ice & Water Sand is permitted to be used as prescribed in FBC Section 1507.1.1 and Table 1507.1.1.1 for mechan'ically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. i QUIK-Stick HT Smooth QUIK-Stick HT Smooth is an ASTM D 1970;TAS 103, and FRSAITRI Florida High Wind Concrete and Clay Tile Installation Manual, Sixth Edition compliant self-adhesive underlayment constructed from SBS modified asphalt with a fiberglass mat reinforcement and woven poly-fabric surfacb. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft or 3-ft 3-in x 61-ft and has a nominal thickness of 60 mils. QUIK-Stick HT Smooth (Woven Facer) is jo be used as prescribed in FBC Section 1507.1.1 and Table 1507.1.1.1. QUIK!Stick HT is permitted to be used with mechanically attached or adhered clay or concrete tile roofing using either DAP Touch'n Seal®Storm Bond Roof Tile Adhesive or DuPontT°" TILE BONDTm Roof Tile Adhesive. Exposure on the roof deck shall be limited to,a maximum 180 days. The maximum roof slope shall be 6:12 when used with clay or concrete the installations without battens. Tile shall be stored on batiens for roof slopes greater than 6:12. Tiles shall not be stacked greater 10 tiles per stack. QUIK-Stick HT Pro QUIK-Stick HT Pro is an ASTM D 1970 self-adhesive underlayment constructed from SBS modified asphalt with a fiberglass mat!reinforcement and poly-fabric surface. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft and has a nominal thickness of 60 mils. i QUIK-Stick HT Pro is permitted to be used as prescribed in FBC Section 1507.1.1 and Table 1507.1.1.1 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days.l i QUIK-Stick FS QUIK-Stick FS is an ASTM D 1970 self-adhesive underlayment constructed from SBS modified asphalt with a fiberglass mat reinforcement and textured film surface. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft and has a nominal thickness of 45 mils. QUIK-Stick FS is permitted to be used as prescribed in FBC Section 1507.1.1 and Table I 1507.1.1.1 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. MSA17001.2 FL17401-R5 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule`:61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. I I ' �� MID-STATES ASPHALT AND CANT STRIP,INC Self-Adhering Underlayments TECHNICAL SERVICES,LLC GENERAL LIMITATIONS 1) This evaluation report is not for use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. 5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements. 6) All side lap seams shall be installed to shed water from the deck. 7) The underlayment may be used as described in other current FBC product approval documents. 8) Design wind load pressures shall be determined for components and cladding in accordance with FBC 1609. 9) The roof deck shall be designed by others in accordance with i FBC requirements to resist the design wind load pressures for components and cladding. 10) Maximum Design Pressures for a given underlayment shall meet or exceed the design wind loads determined for the roof assembly. 11) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. i COMPLIANCE STATEMENT I The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code,7t'Edition(2020)as evidenced in the referenced documents submitted by the named manufacturer. R. pR��, j 2020.10.16 .` G • GEN• . P • • \ S• S . i No 74021 = 14:26:19 � i Iz_ —041 00 .- STATE OF :44/: '��'�`�•:c( O R 1 p P:•'\�,.� Zachary R.Priest, P.E. Florida Registration No.SS10NA1- Organzation No.A E9641o21 �Illnt I CERTIFICATION OF INDEPENDENCE i CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. i i Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT MSA17001.2 FL17401-R5 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed h i erein. REVISIONS i a ' r--r(TVP) 'a O O O (TVP) E co e 0 0 o RECEIVED 00 01 LU v LU �O ® O 10(D MAR 2 5 2021oST. Lucie County, Permitting z Lo ROOF ZONES LLB GABLE/FLAT LU® °' � m � ROOF SCHEDULE ROOF SYSTEM BUILDING PRODUCT m Zone Deck,Insulation,8 PRESSURE PRESSURE V Attachment Manufacturer Model Florida Product Approval (PSF) (PSF) 1,2e SEE NOTE 2 ATLANTIC METAL 24ga 1.0"NAIL STRIP ON FL17796.4 -57.6 -59.75 II OF VERO BEACH PLYWOOD-METHOD A 2n,2r, SEE NOTE 2 ATLANTIC METAL I 24ga 1.0"NAIL STRIP ON FL17796.4 -92.4 -101 3e II OF VERO BEACHI PLYWOOD-METHOD A ■ 3R SEE NOTE 2 ATLANTIC METAL 24ga 1.0"NAIL STRIP ON FL17796.4 -99.3 -101 II OF VERO BEACH PLYWOOD-METHOD B ■ L 0> w DESIGN CRITERIA 7 0 a, m FBC 2020 ® v CCU ULTIMATE WIND SPEED, VULT 160 MPH LL EXPOSURE "C" 0 c'LL INTERNAL PRESSURE COEFFICIENT +/— 0.18 _ On D ai RISK CATEGORY II 0 e c ROOF PITCH 5/12 00 d HEIGHT & EXPOSURE COEFFICIENT 1.00 a C E c C 0 ZONE 3 WIDTH, a 5FT _� P z lot III/ PIC NOTES: o' ° Edward Rosho,PE o m 1. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING ALL DIMENSIONS FOR PROPER FIT PRIOR TO ' fc�? ' CONSTRUCTION. Y' 0 e 2. SEE MANUFACTURER'S REQUIREMENTS FOR DECK, INSULATION, AND ROOF COVER REQUIREMENTS, AS APPLICABLE. a ° 0 2.1. DECK: MIN. 15/32 INCH THICK PLYWOOD. e ST E OF o© 2.2. UNDERLAYMENT: POLYGLASS POLYSTICK MTS (FL5259.1), ATTACH PER MANUFACTURER'S RECOMMENDATIONS. �� ►O Po® ��1��®®� 2.3. FASTENERS: #10 X 1" FASTENER IN PANEL SLOT AT 16" O.C. FOR METHOD A OR 6.75" O.C. FOR METHOD B. r�fa4 S METAL ROOF PANEL FASTENING ®1 03/23/21