Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutAPPROVED 2020 GAF Modified Bitumen1/5/2021 Florida Building Code Online
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqt45H1a2AP3IyZlwDnCBwq72VON4m4jLPNO7o5S%2bzZMaw%3d%3d 1/2
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #FL5680-R29
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer GAF
Address/Phone/Email 1 Campus Drive
Parisppany, NJ 07054
(800) 766-3411
mstieh@gaf.com
Authorized Signature Robert Nieminen
lreith@nemoetc.com
Technical Representative William Broussard
Address/Phone/Email 1 Campus Drive
Parsippany, NJ 07054
(800) 766-3411
TechnicalQuestionsGAF@gaf.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Modified Bitumen Roof System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the
Evaluation Report
Robert J.M. Nieminen
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/06/2022
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL5680_R29_COI_2020_01_COI_NIEMINEN.pdf
Referenced Standard and Year (of Standard)Standard Year
ASTM D2178 2015
ASTM D4601 2012
ASTM D4897 2009
ASTM D6163 2015
ASTM D6164 2011
ASTM D6222 2011
FM 4470 2016
FM 4474 2011
TAS 114 2011
1/5/2021 Florida Building Code Online
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqt45H1a2AP3IyZlwDnCBwq72VON4m4jLPNO7o5S%2bzZMaw%3d%3d 2/2
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/14/2020
Date Validated 10/17/2020
Date Pending FBC Approval 10/25/2020
Date Approved 12/15/2020
Summary of Products
FL #Model, Number or Name Description
5680.1 GAF Modified Bitumen Roof Systems SBS and APP Modified Bitumen Roof Systems
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-465
Other: 1.) The DP noted herein pertains to one specific
system. Refer to the ER Appendix for all systems and max.
design pressures. 2.) Refer to ER Section 5 for Limits of Use.
3.) Refer to File No. FL16732 for HVHZ jurisdictions.
Installation Instructions
FL5680_R29_II_2020_10_11_FINAL_A1_ER_FL5680-R29.pdf
Verified By: Robert Nieminen PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FL5680_R29_AE_2020_10_11_FINAL_ER_FL5680-R29.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
NEMO|etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATION REPORT
GAF
1 Campus Drive
Parsippany, NJ 07054
(800) 766-3411
Evaluation Report 01506.11.05-R29
FL5680-R29
Date of Issuance: 11/07/2005
Revision 29: 10/11/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 7th Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: GAF Modified Bitumen Roof Systems
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words “NEMO|etc. Evaluated” may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6, plus a 91-page Appendix.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert
Nieminen, P.E. on 10/11/2020. This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing produ cts for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
©2019 NEMO ETC, LLC
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL5680-R29
GAF Modified Bitumen Roof Systems Revision 29: 10/11/2020
Page 2 of 6
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Modified Bitumen Roof Systems
Compliance Statement: GAF Modified Bitumen Roof Systems, as produced by GAF, have demonstrated
compliance with the following sections of the 7th Edition (2020) Florida Building Code through testing in accordance
with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions
of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind resistance FM 4474 2011
1515.1.1 Wind resistance TAS 114, Appendix C, D or J 2011
1504.7 Impact resistance FM 4470 2016
1507.10.2 Material standard ASTM D2178 2015
1507.10.2 Material standard ASTM D4601 2012
1507.10.2 Material standard ASTM D4897 2009
1507.11.2 Material standard ASTM D6163 2015
1507.11.2 Material standard ASTM D6164 2011
1507.11.2 Material standard ASTM D6222 2011
3. REFERENCES:
Entity Examination Reference Date Entity Examination Reference Date
ACRC (TST4671) TAS 114 ACRC 06-041 11/10/2006 FM (TST1867) FM 4470/4474 797-06177-267 03/16/2011
ACRC (TST4671) TAS 114 ACRC 06-042 11/14/2006 FM (TST1867) FM 4470/4474 797-06540-267 06/21/2011
ACRC (TST4671) TAS 114 ACRC 06-043 11/16/2006 FM (TST1867) FM 4470/4474 797-06800-267 09/29/2011
ACRC (TST4671) TAS 114 ACRC 006-044 11/16/2006 FM (TST1867) FM 4470/4474 797-07038-267 01/10/2012
ACRC (TST4671) TAS 114 ACRC 06-048 12/21/2006 FM (TST1867) FM 4470/4474 797-07073-267 01/19/2012
ACRC (TST4671) TAS 114 ACRC 06-049 12/22/2006 FM (TST1867) FM 4470/4474 3038128 07/26/2010
ACRC (TST4671) TAS 114 ACRC 06-050 12/28/2006 FM (TST1867) FM 4470/4474 3040738 11/16/2010
ACRC (TST4671) TAS 114 ACRC 07-006 01/17/2007 FM (TST1867) FM 4470/4474 3041535 06/08/2011
ACRC (TST4671) TAS 114 ACRC 07-018 04/20/2007 FM (TST1867) FM 4470/4474 3044688 03/01/2012
ACRC (TST4671) TAS 114 ACRC 07-028 05/08/2007 FM (TST1867) FM 4470/4474 797-07198-267 03/01/2012
ACRC (TST4671) TAS 114 ACRC 07-030 05/09/2007 FM (TST1867) FM 4470/4474 3044688 (Re-Issue) 03/16/2012
ACRC (TST4671) TAS 114 ACRC 07-032 05/10/2007 FM (TST1867) FM 4470/4474 3044541 04/04/2012
ACRC (TST4671) TAS 114 ACRC 07-033 05/10/2007 FM (TST1867) FM 4470/4474 3044862 05/11/2012
ACRC (TST4671) TAS 114 ACRC 07-041 08/31/2007 FM (TST1867) FM 4470/4474 3043900 08/16/2012
ACRC (TST4671) TAS 114 ACRC 07-044 09/05/2007 FM (TST1867) FM 4470/4474 3046280 08/22/2012
ACRC (TST4671) TAS 114 ACRC 07-047 09/07/2007 FM (TST1867) FM 4470/4474 3046388 09/24/2012
ACRC (TST4671) TAS 114 ACRC 07-081 01/10/2008 FM (TST1867) FM 4470/4474 3041769 09/27/2012
ACRC (TST4671) TAS 114 ACRC 07-082 01/11/2008 FM (TST1867) FM 4470/4474 3046403 09/28/2012
ACRC (TST4671) TAS 114 ACRC 08-024 04/18/2008 FM (TST1867) FM 4470/4474 3046054 12/21/2012
ACRC (TST4671) TAS 114 ACRC 08-034 05/19/2008 FM (TST1867) FM 4470/4474 3046081 02/13/2013
ACRC (TST4671) TAS 114 ACRC 08-044 07/01/2008 FM (TST1867) FM 4470/4474 797-08216-267 04/11/2013
ACRC (TST4671) TAS 114 ACRC 11-043 08/08/2011 FM (TST1867) FM 4470/4474 3048122 04/29/2013
ACRC (TST4671) TAS 114 ACRC 11-046 08/09/2011 FM (TST1867) FM 4470/4474 3047104 05/10/2013
ACRC (TST4671) TAS 114 ACRC 11-048 08/10/2011 FM (TST1867) FM 4470/4474 797-08263-267 05/23/2013
ACRC (TST4671) TAS 114 ACRC 11-049 08/10/2011 FM (TST1867) FM 4470/4474 797-08264-267 05/23/2013
ACRC (TST4671) TAS 114 ACRC 11-050 08/11/2011 FM (TST1867) FM 4470/4474 3047237 07/15/2013
ACRC (TST4671) TAS 114 ACRC 11-051 08/11/2011 FM (TST1867) FM 4470/4474 797-08670-267 09/16/2013
ACRC (TST4671) TAS 114 ACRC 11-052 08/12/2011 FM (TST1867) FM 4470/4474 797-08873-267 11/26/2013
ACRC (TST4671) TAS 114 ACRC 11-053 08/17/2011 FM (TST1867) FM 4470/4474 3048871 12/11/2013
ACRC (TST4671) TAS 114 ACRC 11-054 08/17/2011 FM (TST1867) FM 4470/4474 3048066 12/13/2013
ACRC (TST4671) TAS 114 ACRC 12-015 04/24/2012 FM (TST1867) FM 4470/4474 797-09016-267 12/17/2013
ACRC (TST4671) TAS 114 ACRC 12-026 05/10/2012 FM (TST1867) FM 4470/4474 3048496 12/19/2013
ACRC (TST4671) TAS 114 ACRC 12-034 08/10/2012 FM (TST1867) FM 4470/4474 3049601 01/29/2014
ACRC (TST4671) TAS 114 ACRC 12-035 08/13/2012 FM (TST1867) FM 4470/4474 797-09984-267 10/28/2014
ACRC (TST4671) TAS 114 ACRC 16-002 03/04/2016 FM (TST1867) FM 4470/4474 797-09987-267 10/28/2014
ERD (TST6049) TAS 114/FM4474 01880.09.03 09/10/2003 FM (TST1867) FM 4470/4474 797-10017-267 11/06/2014
ERD (TST6049) TAS 114/FM4474 01516.04.06 04/20/2006 FM (TST1867) FM 4470/4474 RR205568 06/15/2016
ERD (TST6049) TAS 114/FM4474 4482.10.97-1 12/02/2006 FM (TST1867) FM 4470/4474 RR205474 08/31/2016
ERD (TST6049) TAS 114/FM4474 G4280LAB.10.06-R1 12/06/2007 FM (TST1867) FM 4470 / 4474 3058483 12/09/2016
ERD (TST6049) ASTM D6164 (CA-S) G6850.08.08-1 08/29/2008 FM (TST1867) FM 4470 / 4474 RR208244 02/02/2017
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL5680-R29
GAF Modified Bitumen Roof Systems Revision 29: 10/11/2020
Page 3 of 6
Entity Examination Reference Date Entity Examination Reference Date
ERD (TST6049) ASTM D6222 (CA-S) G6850.10.08 10/06/2008 FM (TST1867) FM 4470 / 4474 RR208306 02/02/2017
ERD (TST6049) ASTM D6222 (GA) G6850.11.08 11/05/2008 FM (TST1867) FM 4470 / 4474 RR208456 02/13/2017
ERD (TST6049) ASTM D6163 (GA) G34140.04.11-2 04/25/2011 FM (TST1867) FM 4470 / 4474 3062588 (PLA) 08/01/2017
ERD (TST6049) ASTM D4601 (GA) G34140.04.11-4 04/25/2011 FM (TST1867) FM 4470 / 4474 Letter 02/13/2018
ERD (TST6049) ASTM D4897 (GA) G34140.04.11-5 04/25/2011 FM (TST1867) FM 4470 / 4474 3061784 07/25/2018
ERD (TST6049) TAS 114/FM4474 G36780.07.11-R1 07/18/2011 FM (TST1867) FM 4470 / 4474 3055904 10/25/2018
ERD (TST6049) ASTM D6222 (GA) G43190.11.13-1 11/15/2013 FM (TST1867) FM 4470 / 4474 RR215191-267 11/07/2018
ERD (TST6049) ASTM D6163 (GA) G40630.01.14-1 01/06/2014 FM (TST1867) FM 4470 PR452971 02/19/2020
ERD (TST6049) ASTM D6164 (GA) G40630.01.14-2B-R2 01/07/2014 IRT (TST7408) TAS 114 00001 03/30/2000
ERD (TST6049) ASTM D6164 (GA) G40630.01.14-2C 01/07/2014 IRT (TST7408) TAS 114 00002 03/30/2000
ERD (TST6049) ASTM D4601 (IN) G43180.01.14-1 01/10/2014 IRT (TST7408) TAS 114 01-039 01/24/2002
ERD (TST6049) ASTM D6222 (IN) G43180.03.14 03/03/2014 IRT (TST7408) TAS 114 02-005 01/24/2002
ERD (TST6049) ASTM D6222 (CA-S) G43190.03.14-1 03/06/2014 IRT (TST7408) TAS 114 02-014 03/26/2002
ERD (TST6049) ASTM D6222 (CA-S) G43190.03.14-2 03/06/2014 IRT (TST7408) TAS 114 03-003 04/21/2003
ERD (TST6049) ASTM D6164 (GA) G40630.01.14-2A-1-R1 04/10/2014 IRT (TST7408) TAS 114 03-004 04/21/2003
ERD (TST6049) ASTM D6222 (GA) G43190.05.14-R1 05/20/2014 IRT (TST7408) TAS 114 04-008 01/26/2004
ERD (TST6049) ASTM D6163 (CA-S) G46160.09.14-2A 09/09/2014 ITS (TST1558) TAS 114 H9486.03-109-18 09/17/2018
ERD (TST6049) ASTM D6164 (GA) G46160.09.14-3A 09/09/2014 ITS (TST1558) TAS 114 H9486.04-109-18 09/17/2018
ERD (TST6049) ASTM D6164 (GA) G46160.09.14-3B 09/09/2014 M-D (CER1592) TAS 114 13-0617.20 09/05/2013
ERD (TST6049) ASTM D6164 (GA) G46160.09.14-3C 09/09/2014 M-D (CER1592) TAS 114 13-0307.02 09/26/2013
ERD (TST6049) ASTM D6164 (GA) G46160.12.14-3E 12/29/2014 M-D (CER1592) TAS 114 13-1007.09 01/30/2014
ERD (TST6049) TAS 114/FM4474 SC8580.11.15-3 11/09/2015 NEMO (TST6049) ASTM D6222 (GA) G30250.02.10-2-R1 02/11/2010
ERD (TST6049) TAS 114/FM4474 SC8580.01.16-1 01/20/2016 NEMO (TST6049) ASTM D6164 (CA-S) G33470.01.11-R1 01/13/2011
ERD (TST6049) ASTM D4601 (GA) GAF-SC13285.02.17-2 02/08/2017 NEMO (TST6049) ASTM D6163 (GA) G34140.04.11-2-R1 04/25/2011
ERD (TST6049) ASTM D6163 (GA) G46160.02.15-2d-1 02/09/2017 NEMO (TST6049) ASTM D6222 (GA) G40620.07.12-2-R1 07/17/2012
ERD (TST6049) ASTM D6164 (GA) GAF-SC13285.03.17-5 03/23/2017 NEMO (TST6049) ASTM D6163 (GA) 4S-GAF-18-001.11.18 11/06/2018
ERD (TST6049) ASTM D6164 (GA) GAF-SC13105.03.17-R1 04/04/2017 NEMO (TST6049) ASTM D2178 (GA) 4S-GAF-18-001.01.19-1 01/02/2019
ERD (TST6049) D4601/D1970 (IN) GAF-SC16440.12.17 12/31/2017 NEMO (TST6049) ASTM D6222 (IN) 4S-GAF-18-001.03.19.A 03/13/2019
ERD (TST6049) TAS 114/FM4474 GAF-SC16825.12.17-1 12/31/2017 NEMO (TST6049) ASTM D6164 (AR) 4q-GAF-19-SSMBB-01A 04/08/2019
F-TEC (TST7393) TAS 114 08-050187 04/28/2008 NEMO (TST6049) ASTM D6163 (AR) 4q-GAF-19-SSMBB-02A 04/08/2019
F-TEC (TST7393) TAS 114 08-050188 04/28/2008 NEMO (TST6049) FM 4474 4L-GAF-18-002.05.19.A 05/29/2019
F-TEC (TST7393) TAS 114 08-070077 07/25/2008 PRI (TST5878) FM 4470/4474 GAF-434-02-01 09/16/2013
F-TEC (TST7393) TAS 114 08-070084 07/25/2008 PRI (TST5878) FM 4470/4474 GAF-434-02-03 09/16/2013
F-TEC (TST7393) TAS 114 08-050181R 04/01/2009 PRI (TST5878) FM 4470/4474 GAF-434-02-04 09/16/2013
F-TEC (TST7393) TAS 114 08-050186 10/14/2008 PRI (TST5878) FM 4470/4474 GAF-436-02-02 03/06/2014
F-TEC (TST7393) TAS 114 08-070126 10/14/2008 PRI (TST5878) FM 4470/4474 GAF-436-02-03 03/06/2014
F-TEC (TST7393) TAS 114 08-070122 10/14/2008 PRI (TST5878) FM 4470/4474 GAF-436-02-04 03/06/2014
F-TEC (TST7393) TAS 114 08-070127 10/14/2008 PRI (TST5878) FM 4470/4474 GAF-436-02-05 03/06/2014
F-TEC (TST7393) TAS 114 08-080077 11/17/2008 PRI (TST5878) FM 4470/4474 GAF-436-02-08 03/06/2014
FM (TST1867) FM 4470 1B9A8.AM 09/04/1997 PRI (TST5878) FM 4470/4474 GAF-436-02-09 03/06/2014
FM (TST1867) FM 4470 3007500 06/15/2000 PRI (TST5878) FM 4470/4474 GAF-549-02-01 08/08/2014
FM (TST1867) FM 4470 3005640 11/09/2000 PRI (TST5878) FM 4470/4474 GAF-549-02-02 08/08/2014
FM (TST1867) FM 4470 3008178 12/27/2000 PRI (TST5878) FM 4470/4474 GAF-559-02-01 10/16/2014
FM (TST1867) FM 4470 3010215 03/01/2001 PRI (TST5878) FM 4470/4474 GAF-559-02-05 10/16/2014
FM (TST1867) FM 4470 3009788 03/28/2001 PRI (TST5878) FM 4470/4474 GAF-559-02-06 10/16/2014
FM (TST1867) FM 4470 3011140 08/14/2001 PRI (TST5878) FM 4470/4474 GAF-559-02-07 10/16/2014
FM (TST1867) FM 4470 3013614 05/06/2002 PRI (TST5878) Criticality GAF-559-02-08 10/16/2014
FM (TST1867) FM 4470 3013788 01/10/2003 PRI (TST5878) FM 4470/4474 GAF-559-02-09 10/16/2014
FM (TST1867) FM 4470 3014547 05/22/2003 PRI (TST5878) FM 4470/4474 GAF-559-02-11 10/16/2014
FM (TST1867) FM 4470 3014692 08/05/2003 PRI (TST5878) FM 4470/4474 GAF-559-02-12 10/16/2014
FM (TST1867) FM 4470 3014960 03/05/2004 PRI (TST5878) FM 4470/4474 GAF-559-02-13 10/16/2014
FM (TST1867) FM 4470/4474 3017250 04/05/2004 PRI (TST5878) FM 4470/4474 GAF-559-02-14 10/16/2014
FM (TST1867) FM 4470/4474 3022139 05/26/2005 PRI (TST5878) FM 4470/4474 GAF-559-02-15 10/16/2014
FM (TST1867) FM 4470/4474 3022508 07/20/2005 PRI (TST5878) FM 4470/4474 GAF-559-02-16 10/16/2014
FM (TST1867) FM 4470/4474 3025023 12/14/2005 PRI (TST5878) FM 4470/4474 GAF-559-02-17 10/16/2014
FM (TST1867) FM 4470/4474 797-02095-267 04/26/2006 PRI (TST5878) FM 4470/4474 GAF-559-02-18 10/16/2014
FM (TST1867) FM 4470/4474 3023458 07/18/2006 PRI (TST5878) FM 4470/4474 GAF-559-02-04-R1 03/04/2015
FM (TST1867) FM 4470/4474 3028039 09/11/2006 PRI (TST5878) FM 4470/4474 GAF-559-02-19 04/17/2015
FM (TST1867) FM 4470/4474 3024805 11/20/2006 PRI (TST5878) FM 4470/4474 GAF-746-02-05 12/15/2016
FM (TST1867) FM 4470/4474 3032388 10/30/2008 PRI (TST5878) FM 4470/4474 GAF-746-02-06 12/15/2016
FM (TST1867) FM 4470/4474 3032695 10/30/2008 PRI (TST5878) FM 4470/4474 GAF-755-02-01 02/02/2017
FM (TST1867) FM 4470/4474 3032943 11/06/2008 PRI (TST5878) FM 4470/4474 GAF-755-02-02 02/02/2017
FM (TST1867) FM 4470/4474 3032811 12/11/2008 PRI (TST5878) FM 4470/4474 GAF-755-02-03 02/02/2017
FM (TST1867) FM 4470/4474 3033719 01/16/2009 PRI (TST5878) FM 4470/4474 GAF-755-02-04 02/02/2017
FM (TST1867) FM 4470/4474 3035864 06/03/2009 PRI (TST5878) FM 4470/4474 GAF-747-02-04 09/13/2018
FM (TST1867) FM 4470/4474 3032172 06/12/2009 PRI (TST5878) FM 4470/4474 GAF-747-02-05 09/13/2018
FM (TST1867) FM 4470/4474 3035140 08/10/2009 PRI (TST5878) Criticality GAF-743-02-01 09/14/2018
FM (TST1867) FM 4470/4474 3036225 08/10/2009 PRI (TST5878) Criticality GAF-743-02-02 09/14/2018
FM (TST1867) FM 4470 (s/s) 3036980 08/14/2009 PRI (TST5878) FM 4470/4474 GAF-743-02-03 09/21/2018
FM (TST1867) FM 4470/4474 3034978 09/17/2009 PRI (TST5878) FM 4470/4474 GAF-743-02-04 09/21/2018
FM (TST1867) FM 4470/4474 797-05447-267 04/13/2010 PRI (TST5878) FM 4470/4474 GAF-743-02-05 09/21/2018
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL5680-R29
GAF Modified Bitumen Roof Systems Revision 29: 10/11/2020
Page 4 of 6
Entity Examination Reference Date Entity Examination Reference Date
FM (TST1867) FM 4470/4474 797-05487-267 05/12/2010 PRI (TST5878) FM 4470/4474 GAF-743-02-06 09/21/2018
FM (TST1867) FM 4470/4474 797-05550-267 05/25/2010 PRI (TST5878) FM 4470/4474 GAF-743-02-08 09/21/2018
FM (TST1867) FM 4470/4474 797-05538-267 05/25/2010 PRI (TST5878) FM 4470/4474 GAF-765-02-02 09/21/2018
FM (TST1867) FM 4470/4474 797-05594-267 06/01/2010 PRI (TST5878) FM 4470/4474 GAF-901-02-01 02/27/2019
FM (TST1867) FM 4470/4474 797-05695-267 07/15/2010 PRI (TST5878) FM 4470/4474 GAF-901-02-02 02/27/2019
FM (TST1867) FM 4470/4474 797-05683-267 07/21/2010 PRI (TST5878) FM 4470/4474 GAF-903-02-01 08/15/2019
FM (TST1867) FM 4470/4474 797-05687-267 07/21/2010 PRI (TST5878) Criticality 376T0006-3 09/06/2019
FM (TST1867) FM 4470/4474 797-05748-267 08/10/2010 PRI (TST5878) FM 4470/4474 376T0042 12/20/2019
FM (TST1867) FM 4470/4474 3040738 11/16/2010 PRI (TST5878) FM 4474 376T0063 04/02/2020
FM (TST1867) FM 4470/4474 3036960 11/30/2010 PRI (TST5878) FM 4470, impact 376T0064 04/02/2020
FM (TST1867) FM 4470/4474 797-06129-267 01/13/2011 UL (QUA9625) QA Service confirmation 09/29/2020
UL (QUA9625) QA Florida BCIS Current
4. PRODUCT DESCRIPTION:
This Evaluation Report covers GAF Modified Bitumen Roof Systems installed in accordance with GAF published
installation instructions and the Limitations / Conditions of Use herein.
TABLE 1: ROLL-GOODS FOR MODIFIED BITUMEN ROOF SYSTEMS
Type Product Material Standard Plant(s) Reference Type Grade
Base Sheets
GAFGLAS® #75 Base Sheet ASTM D4601 II N/A CA-F, GA
Tri-Ply® #75 Base Sheet ASTM D4601 II N/A CA-F, GA
GAFGLAS® #80 Ultima™ Base Sheet ASTM D4601 II N/A GA
Liberty™ SBS Mechanically Attached Base Sheet ASTM D4601 II N/A IN
GAFGLAS® Stratavent® Nailable Venting Base Sheet ASTM D4897 II N/A CA-F, GA
GAFGLAS® Stratavent® Perforated Venting Base Sheet ASTM D4897 II N/A CA-F, GA
StormSafe™ Anchor Sheet not codified Ontario
Ply Sheets
GAFGLAS® Ply 4 ASTM D2178 IV N/A AL, CA-F, GA
Tri-Ply® Ply 4 Ply Sheet ASTM D2178 IV N/A AL, CA-F, GA
GAFGLAS® FlexPly™ 6 ASTM D2178 VI N/A AL, CA-F, GA
Liberty™ SBS Self-Adhering Base/Ply Sheet ASTM D4601 II N/A GA ,IN
APP, Smooth-
Surface
Membranes
Ruberoid® Torch Smooth ASTM D6222 I S GA, IN
Tri-Ply® APP Smooth Membrane ASTM D6222 I S GA, IN
APP, Granule
Surfaced
Membranes
Ruberoid® Torch Granule ASTM D6222 I G GA, IN
Tri-Ply® APP Granule Membrane ASTM D6222 I G GA, IN
Ruberoid® Torch Plus Granule FR ASTM D6222 II G GA
Ruberoid® EnergyCap™ Torch Granule FR ASTM D6222 I G CA-S
Ruberoid® EnergyCap™ Torch Plus Granule FR ASTM D6222 II G CA-S
SBS, Smooth-
Surface
Membranes
Ruberoid® 20 Smooth ASTM D6163 I AR, CA-S, GA
Ruberoid® HW 25 Smooth ASTM D6163 I S GA
Ruberoid® HW Smooth ASTM D6164 I S GA
Ruberoid® Mop Smooth ASTM D6164 I CA-S, GA
Ruberoid® Mop Smooth 1.5 ASTM D6164 I CA-S, GA
Ruberoid® Mop Plus Smooth ASTM D6164 II S CA-S
SBS, Granule-
Surface
Membranes
Ruberoid® 30 Granule ASTM D6163 I G GA
Ruberoid® 30 Granule FR ASTM D6163 I G GA
Ruberoid® EnergyCap™ 30 Granule FR ASTM D6163 I G CA-S, GA
Liberty™ SBS Self-Adhering Cap Sheet ASTM D6164 I G AR, GA, IN
Ruberoid® Mop Granule FR ASTM D6164 I G GA
Ruberoid® Mop Granule ASTM D6164 I G GA
Intec Flex PRF ASTM D6164 I G GA
Tri-Ply® SBS Granule Cap Sheet ASTM D6164 I G GA
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL5680-R29
GAF Modified Bitumen Roof Systems Revision 29: 10/11/2020
Page 5 of 6
TABLE 1: ROLL-GOODS FOR MODIFIED BITUMEN ROOF SYSTEMS
Type Product Material Standard Plant(s) Reference Type Grade
SBS, Granule-
Surface
Membranes
Ruberoid® HW Granule ASTM D6164 I G GA
Ruberoid® HW Granule FR ASTM D6164 I G GA
Ruberoid® Mop Plus Granule FR ASTM D6164 II G GA
Ruberoid® Mop Plus Granule ASTM D6164 II G GA
Ruberoid® EnergyCap™ Mop Plus Granule FR ASTM D6164 II G CA-S
Ruberoid® HW Plus Granule ASTM D6164 II G GA
Ruberoid® HW Plus Granule FR ASTM D6164 II G GA
Ruberoid® EnergyCap™ HW Plus Granule FR ASTM D6164 II G CA-S
5. LIMITATIONS:
5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami-
Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 This Evaluation Report does not include evaluation of roof edge termination. Refer to FBC 1504.5 for requirements
and limitations regarding edge securement for low-slope roofs.
5.6 Refer to FBC 1511 for requirements and limitations regarding recover installations.
5.6.1 For mechanically attached components over existing roof decks, fasteners shall be tested in the existing deck for
withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum
requirements for the system. Testing shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard
TAS 105.
5.6.2 For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the
existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any
surface conditions exist that bring system performance into question, field uplift testing in accordance with
ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall
be conducted on mock-ups of the proposed new roof assembly.
5.6.3 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall
be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having
Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data
Sheet 1-52 or Testing Application Standard TAS 124.
5.7 Refer to Appendix 1 for system attachment requirements for wind load resistance.
5.7.1 “MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,
and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already
been applied). Refer to FBC 1609 for determination of design wind loads.
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL5680-R29
GAF Modified Bitumen Roof Systems Revision 29: 10/11/2020
Page 6 of 6
5.7.2 For mechanically attached components or partially-bonded insulation, the maximum design pressure for the
selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with
FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design
professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss
Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137.
Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data
Sheet 1-29 (February 2020) for Zone 2/3 enhancements.
5.7.3 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly
shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis
is permitted for these systems.
5.8 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3.
Refer to the Product Approval of the component manufacturer for components listed in Appendix 1 that are
produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report.
6. INSTALLATION:
GAF Modified Bitumen Roof Systems shall be installed in accordance with GAF published installation instructions,
subject to the Limitations / Conditions of Use noted herein.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
8. MANUFACTURING PLANTS:
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
9. QUALITY ASSURANCE ENTITY:
UL, LLC – QUA9625: (414) 248-6409, karen.buchmann@ul.com
- THE 91-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT -
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 1 of 91
APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
TABLE DECK APPLICATION TYPE DESCRIPTION PAGE
1A Wood New, Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 6
1B Wood New, Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 6-10
1C Wood New, Reroof (Tear-Off), Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 10-14
1D Wood New, Reroof (Tear-Off), Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 14
1E Wood New, Reroof (Tear-Off), Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 14-15
1F Wood New, Reroof (Tear-Off), Recover D-2 Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 16
1G Wood New, Reroof (Tear-Off) E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 16-17
1H Wood New, Reroof (Tear-Off), Recover E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 18
1I Wood New, Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 18
2A Steel or Structural concrete New, Reroof (Tear-Off), Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 19-26
2B Steel or Structural concrete New, Reroof (Tear-Off), Recover B-2 Mech. Attached Thermal Barrier, Bonded Temp Roof, Bonded Insulation, Bonded Roof Cover 26-30
2C Steel or Structural concrete New, Reroof (Tear-Off), Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 31-38
2D Steel or Structural concrete New, Reroof (Tear-Off), Recover C-1A Thermal Barrier with Vapor Barrier, Mech. Attached Insulation, Bonded Roof Cover 39
2E Steel or Structural concrete New, Reroof (Tear-Off), Recover C-3 Bonded and Mech. Attached Insulation, Bonded Roof Cover 39
2F Steel or Structural concrete New, Reroof (Tear-Off), Recover D-2 Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 40-43
3A Structural concrete New, Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover (Base Insulation Layer Only) 44-46
3B Structural concrete New, Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover (Base and Top Insulation Layers) 46-54
3C Structural concrete New, Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 55
4A Lightweight concrete New, Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 56-58
4B Lightweight concrete New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 59
4C Lightweight concrete New, Reroof (Tear-Off) E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 60-63
4D Lightweight concrete New, Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 63
5A Cementitious wood fiber New, Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 64
5B Cementitious wood fiber New, Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 64-65
5C Cementitious wood fiber New, Reroof (Tear-Off) E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 66
6A Gypsum Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 67
6B Gypsum Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 67-68
6C Gypsum Reroof (Tear-Off) C-1 Mech. Attached Insulation, Bonded Roof Cover 68
6D Gypsum Reroof (Tear-Off) E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 68-69
7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover (Base Insulation Layer Only) 70-77
7B Various Recover A-1 Bonded Insulation, Bonded Roof Cover (Base and Top Insulation Layers) 78-91
The following notes apply to the systems outlined herein:
1 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having
Jurisdiction.
2 Unless otherwise noted, fasteners and stress plates shall be as follows. Fasteners shall be of sufficient length for the following engagements:
➢ Wood Deck: Drill-Tec #12 Fastener or Drill-Tec #14 Fastener with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate (insulation
only), Drill-Tec ASAP 3S, Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3” Metal Plate, Drill-Tec #12 DP Fastener or Drill-Tec #14 HD Fastener with Drill-Tec 3” Flat Steel
Plate, Drill-Tec #12 DPH Fastener with Drill-Tec 3” Recessed Steel Plate, Drill-Tec 3” ASAP Flat or Drill-Tec 3” ASAP Recessed. Minimum 0.75-inch plywood penetration or minimum 1-inch
wood plank embedment.
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 2 of 91
➢ Steel Deck: Drill-Tec #12 Fastener, Drill-Tec #14 Fastener or Drill-Tec XHD Fastener with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac
Recessed Plate (insulation only); Drill-Tec ASAP 3S; Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3” Metal Plate; Drill-Tec Extra Heavy Duty ASAP Roofing Fastener -
Insulation, Drill-Tec #12 DP Fastener, Drill-Tec #14 HD Fastener or Drill-Tec #15 EHD Fastener with Drill-Tec 3” Flat Steel Plate, Drill-Tec #12 DPH Fastener with Drill-Tec 3” Recessed Steel
Plate, Drill-Tec 3” ASAP Flat or Drill-Tec 3” ASAP Recessed. Minimum 0.75-inch steel penetration and engage the top flute of the steel deck.
➢ Structural Concrete: Drill-Tec #14 Fastener or Drill-Tec CD-10 with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate (insulation only),
Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3” Metal Plate, Drill-Tec #14 HD Fastener with Drill-Tec 3” Flat Steel Plate or Drill-Tec 3” ASAP Flat (#14 only). Minimum 1-
inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer’s published installation instructions.
3 Unless otherwise noted, insulation may be any one layer or combination of FBC Approved (Local or Statewide) board(s) that meet FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof
cover.
4 Minimum 200 psi, minimum 2-inch thick FBC Approved lightweight insulating concrete may be substituted for rigid insulation board for System Types B-1, C-1, C-2, D-1 or D-2, whereby fasteners are installed
through the lightweight insulating concrete to engage the structural deck. The structural deck shall be of equal or greater type, thickness and strength to the steel and structural concrete deck listings. Roof
decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This is a wind uplift resistance allowance and does not purport to address non-
wind-uplift-related issues, such as deck venting or moisture levels within the LWIC and the potential effect on overlying components.
5 Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (February 2020).
6 Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer’s published
instructions.
➢ Hot asphalt: Full Coverage at 25-30 lbs/square. If applying to concrete deck; deck shall be primed with ASTM D41 primer.
➢ GAF 2-Part Roofing Adhesive (G-2-Part): Continuous 2.5 to 3.5-inch ribbons, 12-inch o.c.
➢ LRF Adhesive M (LRF-M): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c.
➢ H.B. Fuller Millennium One-Step Foamable Adhesive (M-OSFA): Continuous 1-inch wide ribbons, 12-inch o.c.
➢ OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. using OMG PaceCart, SpotShot or Canister delivery methods. Note: OlyBond Classic or
OlyBond 500 Green may be used where OlyBond 500 is referenced
➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, board joints shall be staggered.
➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
7 Unless otherwise noted, all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following
Maximum Design Pressure (MDP) limitations. In no case shall these values be used to ‘increase’ the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in
the tables, then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table.
➢ Hot asphalt: MDP = -240.0 psf (Min. 0.5-inch thick)
➢ GAF 2-Part Roofing Adhesive (GAF 2-Part): MDP = -117.5 psf (Min. 1.0-inch thick)
➢ LRF Adhesive M (LRF-M): MDP = -232.5 psf (Min. 0.5-inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation)
➢ H.B. Fuller Millennium One-Step Foamable Adhesive (M-OSFA): MDP = -157.5 psf (Min. 0.5-inch thick polyisocyanurate)
➢ OlyBond 500 (OB500): MDP = -292.5 psf (Min. 0.5-inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation)
➢ OlyBond 500 (OB500): MDP = -315.0 psf (Min. 0.5-inch thick EnergyGuard RH or RN)
➢ OlyBond 500 (OB500): MDP = -487.5 psf (Min. 0.5-inch thick EnergyGuard RA)
8 For adhered roof insulation and board-size: Unless otherwise noted, refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29 (February 2020).
9 For mechanically attached components or partially-bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in
accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies mar ked with an asterisk* carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for Zone 2/3 enhancements.
10 For assemblies with all components fully bonded, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No
rational analysis is permitted for these systems.
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 3 of 91
11 For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105.
12 For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be
installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation
or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having
Jurisdiction, as documented through field uplift testing. Field uplift testing shall be in accordance with ASTM E907, FM Los s Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
13 Refer to FBC 1511 for requirements and limitations regarding recover installations. For Structural Concrete Deck or Recover Applications using System Type C-1, C-2, D-1 or D-2, the insulation is optional.
Alternatively, an FBC Approved insulation board or coverboard may be used as a separation layer. Board products shall be preliminarily attached prior to roof cover installation (Note 5 herein). The separator
component shall be documented as meeting FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications.
14 Lightweight insulating concrete (LWIC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current
LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the
minimum top-coat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. For “pre-existent” LWIC references, listings were established through testing over
lightweight concrete cast using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami-Dade BCCO (FBC
CER1592). Use of these listings in new construction or re-roof (tear-off) applications is at the discretion of the Designer or Record and Authority Having Jurisdiction.
15 For single-ply membranes in System Type D-1 steel deck applications, the roof membrane shall be run with its length perpendicular to the steel deck flutes. For bonded membrane applications, unless otherwise
noted, refer to the following.
MEMBRANE / ADHESIVE COMBINATIONS
REFERENCE LAYER MATERIAL APPLICATION
BP-AA
(Base/ Ply sheets, Asphalt-Applied)
Base Ply: GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet Hot asphalt at 25 lbs/square. Ply: One or more plies GAFGLAS Ply 4, Tri-Ply Ply 4 Ply Sheet, GAFGLAS FlexPly 6
BP-CA
(Base/ Ply sheets, Cold-Applied) Base Ply: GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet Matrix 102 SBS Membrane
Adhesive at 1.5 gal/sq.
SBS-AA
(SBS, Asphalt-Applied)
Base Ply or Ply: One or two plies Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5, Ruberoid Mop Plus Smooth
Hot asphalt at 25 lbs/square. Cap Ply:
Ruberoid 30 Granule, Ruberoid 30 Granule FR, Ruberoid EnergyCap 30 Granule FR, Ruberoid Mop Smooth, Ruberoid
Mop Smooth 1.5, Ruberoid Mop Plus Smooth, Ruberoid Mop Granule FR, Ruberoid Mop Granule, Tri-Ply SBS Granule
Cap Sheet, Intec Flex PRF, Ruberoid Mop Plus Granule FR, Ruberoid Mop Plus Granule, Ruberoid EnergyCap Mop Plus
Granule FR
SBS-CA
(SBS, Cold-Applied)
Base Ply or Ply: Ruberoid 20 Smooth Matrix 102 SBS Membrane
Adhesive at 1.5 gal/sq. Cap Ply: Ruberoid 30 Granule FR, Ruberoid EnergyCap 30 Granule FR, Ruberoid Mop Granule FR, Ruberoid Mop Plus Granule
FR, Ruberoid EnergyCap Mop Plus Granule FR
SBS-CA1
(SBS, Cold-Applied)
Base Ply: Ruberoid 20 Smooth or Ruberoid Mop Smooth 1.5 Matrix 101 Premium SBS
Membrane Adhesive at 1.5 –
2.0 gal/square Cap Ply: Ruberoid 30 Granule FR, Ruberoid EnergyCap 30 Granule FR, Ruberoid Mop Plus Granule FR, Ruberoid EnergyCap Mop
Plus Granule FR
SBS-TA
(SBS, Torch-Applied)
Base Ply or Ply: One or two plies Ruberoid HW 25 Smooth, Ruberoid HW Smooth
Torch applied
Cap Ply: Ruberoid HW Granule, Ruberoid HW Granule FR, Ruberoid HW Plus Granule, Ruberoid HW Plus Granule FR, Ruberoid
EnergyCap HW Plus Granule FR
APP-TA
(APP, Torch-Applied)
Base Ply or Ply: One or two plies Ruberoid Torch Smooth, Tri-Ply APP Smooth Membrane
Cap Ply: Ruberoid Torch Granule, Tri-Ply APP Granule Membrane, Ruberoid Torch Plus Granule FR, Ruberoid EnergyCap Torch
Granule FR, Ruberoid EnergyCap Torch Plus Granule FR
SBS-SA (self-adhering) Base Ply or Ply: Liberty SBS Self-Adhering Base/Ply Sheet Self-adhered Cap Ply Liberty SBS Self-Adhering Cap Sheet
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 4 of 91
16 Vapor barrier options for use over structural concrete deck followed by bonded insulation carry the following MDP limitations. The lesser of the MDP listings below vs. those in Table 3A applies.
VAPOR BARRIER OPTIONS; STRUCTURAL CONCRETE DECK; FOLLOWED BY ADHESIVE-APPLIED INSULATION PER TABLE 3A:
OPTION
# PRIMER VAPOR BARRIER INSULATION ADHESIVE MDP
(PSF) TYPE APPLICATION
C-VB-1. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base
Sheet, GAFGLAS Ply 4, Tri-Ply Ply 4 Ply Sheet or GAFGLAS FlexPly 6 Hot asphalt applied Hot asphalt -360.0
C-VB-2. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Granule Torch-applied GAF 2-Part, 12-inch o.c. -169.0
C-VB-3. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth or Ruberoid HW Smooth Torch-applied GAF 2-Part, 12-inch o.c. -180.0
C-VB-4. GAF SA Primer GAF SA Vapor Retarder Self-adhering GAF 2-Part, 12-inch o.c. -202.5
C-VB-5. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Liberty SBS Self-Adhering Cap Sheet Self-adhering GAF 2-Part, 12-inch o.c. -250.0
C-VB-6. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base
Sheet, GAFGLAS Ply 4, Tri-Ply Ply 4 Ply Sheet or GAFGLAS FlexPly 6 Hot asphalt applied GAF 2-Part, 12-inch o.c. -262.5
C-VB-7. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid 30 Hot asphalt applied GAF 2-Part, 12-inch o.c. -270.0
C-VB-8. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth or Ruberoid HW Smooth Torch-applied LRF-M, 12-inch o.c. -180.0
C-VB-9. GAF SA Primer GAF SA Vapor Retarder Self-adhering LRF-M, 12-inch o.c. -202.5
C-VB-10. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base
Sheet, GAFGLAS Ply 4, Tri-Ply Ply 4 Ply Sheet or GAFGLAS FlexPly 6 Hot asphalt applied LRF-M, 12-inch o.c. -495.0
C-VB-11. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Smooth Torch-applied OlyBond 500, 12-inch o.c. -165.0
C-VB-12. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth Torch-applied OlyBond 500, 12-inch o.c. -180.0
C-VB-13. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Liberty SBS Self-Adhering Cap Sheet Self-adhering OlyBond 500, 12-inch o.c. -187.5
C-VB-14. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid 20 Smooth Matrix 102 SBS Membrane
Adhesive at 1.5 gal/square OlyBond 500, 12-inch o.c. -202.5
C-VB-15. GAF SA Primer GAF SA Vapor Retarder Self-adhering OlyBond 500, 12-inch o.c. -202.5
C-VB-16. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Granule Torch-applied OlyBond 500, 12-inch o.c. -225.0
C-VB-17. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW Smooth Torch-applied OlyBond 500, 12-inch o.c. -232.5
C-VB-18. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base
Sheet, GAFGLAS Ply 4, Tri-Ply Ply 4 Ply Sheet or GAFGLAS FlexPly 6 Hot asphalt applied OlyBond 500, 12-inch o.c. -352.5
16A Vapor barrier options for over structural concrete deck followed by cellular lightweight insulating concrete carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below
vs. those in Tables 4A through 4D applies.
VAPOR BARRIER OPTIONS; STRUCTURAL CONCRETE DECK FOLLOWED BY CELLULAR LIGHTWEIGHT INSULATING CONCRETE PER TABLES 4A THROUGH 4D:
OPTION # PRIMER VAPOR BARRIER LIGHTWEIGHT
CONCRETE
MDP
(PSF) TYPE ATTACH
LWC-VB-1. Matrix 307 Premium Asphalt
Primer or ASTM D41 primer
Base Ply (Optional): One or two plies Ruberoid HW 25 Smooth, Ruberoid HW Smooth
Cap Ply: Ruberoid HW Granule, Ruberoid HW Granule FR, Ruberoid HW Plus Granule, Ruberoid HW Plus Granule FR
Torch-
applied
Min. 200 psi
Mearlcrete (FL13492) -82.5
LWC-VB-2. Matrix 307 Premium Asphalt
Primer or ASTM D41 primer
Base Ply (Optional): One or two plies Ruberoid HW 25 Smooth, Ruberoid HW Smooth
Cap Ply: Ruberoid HW Granule, Ruberoid HW Granule FR, Ruberoid HW Plus Granule, Ruberoid HW Plus Granule FR
Torch-
applied
Min. 300 psi Celcore
Cellular Concrete
(FL2037)
-135.0
LWC-VB-3. Matrix 307 Premium Asphalt
Primer or ASTM D41 primer
Base Ply (Optional): One or two plies Ruberoid HW 25 Smooth, Ruberoid HW Smooth
Cap Ply: Ruberoid HW Granule, Ruberoid HW Granule FR, Ruberoid HW Plus Granule, Ruberoid HW Plus Granule FR
Torch-
applied
Min. 300 psi Elastizell
(FL4994) -302.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 5 of 91
17 Fire barriers of FireOut™ Fire Barrier Coating, VersaShield Solo™ Fire-Resistant Slip Sheet are optional in all assemblies when overlying components are mechanically fastened.
18 The following insulations are interchangeable within the scope of this Evaluation Report:
ACCEPTABLE ALTERNATES (INSULATION)
Listed Product Alternate
EnergyGuard Polyiso Insulation EnergyGuard NH Polyiso Insulation
EnergyGuard Ultra Polyiso Insulation EnergyGuard NH Ultra Polyiso Insulation
EnergyGuard HD Polyiso Insulation EnergyGuard NH HD Polyiso Insulation
EnergyGuard HD Plus Polyiso Insulation EnergyGuard NH HD Plus Polyiso Insulation
19 For System Types B-1, B-2, C-1, C-2, D-1 or Type D-2, GAF SA Vapor Retarder may be installed atop the roof deck prior to installation of the insulation and roof cover. Refer to FM Loss Prevention Data Sheet 1-29
(February 2020) for design and installation limitations.
20 “MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 6 of 91
TABLE 1A: WOOD DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Sys
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
W-1.
Min. 19/32-inch
plywood or OSB; 2
ft span
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra Polyiso Insulation, EnergyGuard
RA, EnergyGuard RH, EnergyGuard RN
GAF 2-Part
Min. 0.5-inch Structodek
High Density Fiberboard
Roof Insulation
GAF 2-Part BP-AA, SBS-AA
(Optional) One or
more BP-AA, SBS-AA,
SBS-TA or APP-TA
SBS-AA, SBS-
TA or APP-TA -52.5
W-2.
Min. 19/32-inch
plywood or OSB; 2
ft span
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra Polyiso Insulation, EnergyGuard
RA, EnergyGuard RH, EnergyGuard RN
GAF 2-Part
Min. 0.25-inch DensDeck,
DensDeck Prime or
SECUROCK Gypsum-Fiber
Roof Board
GAF 2-Part
BP-AA, SBS-AA,
SBS-TA or APP-
TA
(Optional) One or
more BP-AA, SBS-AA,
SBS-TA or APP-TA
SBS-AA, SBS-
TA or APP-TA -52.5
TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15)
MDP
(psf) Type Fasteners
(Note 11) Attach Type
Attach
(Notes
6,7,8)
Type
Attach
(Notes
6,7,8)
Base
Ply Ply Cap Ply
CONVENTIONAL SYSTEMS:
W-3.
Min. 15/32-
inch
plywood or
1-inch
wood
plank; 2 ft
span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
32 ga., 1-
5/8-inch dia.
tin caps with
11 ga.
annular ring
shank nails
8-inch o.c. at
min. 4-inch laps
and 8-inch o.c. in
two, equally
spaced,
staggered center
rows
Min. 1-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation or EnergyGuard
RH Polyiso or min. 1.5-
inch EnergyGuard RA or
EnergyGuard RN
Hot
asphalt
Min. 0.5-inch
Structodek High
Density Fiberboard
Roof Insulation or
EnergyGuard Perlite
Recover Board or
Min. 0.75-inch
EnergyGuard Perlite
Roof Insulation
(homogeneous)
Hot
asphalt
BP-AA,
SBS-AA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-45.0
W-4.
Min. 15/32-
inch
plywood or
1-inch
wood
plank; 2 ft
span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
32 ga., 1-
5/8-inch dia.
tin caps with
11 ga.
annular ring
shank nails
8-inch o.c. at
min. 4-inch laps
and 8-inch o.c. in
two, equally
spaced,
staggered center
rows
Min. 1-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation or EnergyGuard
RH Polyiso or min. 1.5-
inch EnergyGuard RA or
EnergyGuard RN
Hot
asphalt
Min. 0.25-inch
DensDeck Prime
or SECUROCK
Gypsum-Fiber
Roof Board
Hot
asphalt
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-45.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 7 of 91
TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15)
MDP
(psf) Type Fasteners
(Note 11) Attach Type
Attach
(Notes
6,7,8)
Type
Attach
(Notes
6,7,8)
Base
Ply Ply Cap Ply
W-5.
Min. 19/32-
inch
plywood or
1-inch
wood
plank; 2 ft
span
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Eliminator Nailable Venting
Base Sheet, Ruberoid 20
Smooth, Ruberoid Mop
Smooth, Ruberoid Mop
Smooth 1.5
32 ga., 1-
5/8-inch dia.
tin caps with
11 ga.
annular ring
shank nails
9-inch o.c. at the
min. 4-inch lap
and 12-inch o.c.
in two, equally
spaced,
staggered center
rows
Min. 1-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation or EnergyGuard
RH Polyiso or min. 1.5-
inch EnergyGuard RA or
EnergyGuard RN
Hot
asphalt
Min. 0.5-inch
Structodek High
Density Fiberboard
Roof Insulation or
EnergyGuard Perlite
Recover Board or
Min. 0.75-inch
EnergyGuard Perlite
Roof Insulation
(homogeneous)
Hot
asphalt
BP-AA,
SBS-AA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-45.0
W-6.
Min. 19/32-
inch
plywood or
1-inch
wood
plank; 2 ft
span
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Eliminator Nailable Venting
Base Sheet, Ruberoid 20
Smooth, Ruberoid Mop
Smooth, Ruberoid Mop
Smooth 1.5
32 ga., 1-
5/8-inch dia.
tin caps with
11 ga.
annular ring
shank nails
9-inch o.c. at the
min. 4-inch lap
and 12-inch o.c.
in two, equally
spaced,
staggered center
rows
Min. 1-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation or EnergyGuard
RH Polyiso or min. 1.5-
inch EnergyGuard RA or
EnergyGuard RN
Hot
asphalt
Min. 0.25-inch
DensDeck Prime
or SECUROCK
Gypsum-Fiber
Roof Board
Hot
asphalt
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-45.0
W-7.
Min. 15/32-
inch
plywood or
1-inch
wood
plank; 2 ft
span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
32 ga., 1-
5/8-inch
diameter tin
caps with 12
ga. annular
ring shank
nails
6-inch o.c. at the
4-inch lap and 6-
inch o.c. in two
staggered center
rows
Min. 1-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation or EnergyGuard
RH Polyiso or min. 1.5-
inch EnergyGuard RA or
EnergyGuard RN
Hot
asphalt
Min. 0.5-inch
Structodek High
Density Fiberboard
Roof Insulation or
EnergyGuard Perlite
Recover Board or
Min. 0.75-inch
EnergyGuard Perlite
Roof Insulation
(homogeneous)
Hot
asphalt
BP-AA,
SBS-AA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-52.5
W-8.
Min. 15/32-
inch
plywood or
1-inch
wood
plank; 2 ft
span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
32 ga., 1-
5/8-inch
diameter tin
caps with 12
ga. annular
ring shank
nails
6-inch o.c. at the
4-inch lap and 6-
inch o.c. in two
staggered center
rows
Min. 1-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation or EnergyGuard
RH Polyiso or min. 1.5-
inch EnergyGuard RA or
EnergyGuard RN
Hot
asphalt
Min. 0.25-inch
DensDeck Prime
or SECUROCK
Gypsum-Fiber
Roof Board
Hot
asphalt
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-52.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 8 of 91
TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15)
MDP
(psf) Type Fasteners
(Note 11) Attach Type
Attach
(Notes
6,7,8)
Type
Attach
(Notes
6,7,8)
Base
Ply Ply Cap Ply
W-9.
Min. 19/32-
inch
plywood or
1-inch
wood
plank; 2 ft
span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
32 ga., 1-
5/8-inch
diameter tin
caps with 12
ga. annular
ring shank
nails
8-inch o.c. at the
4-inch lap and 8-
inch o.c. in two
staggered center
rows
Min. 1-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation or EnergyGuard
RH Polyiso or min. 1.5-
inch EnergyGuard RA or
EnergyGuard RN
Hot
asphalt
Min. 0.5-inch
Structodek High
Density Fiberboard
Roof Insulation or
EnergyGuard Perlite
Recover Board or
Min. 0.75-inch
EnergyGuard Perlite
Roof Insulation
(homogeneous)
Hot
asphalt
BP-AA,
SBS-AA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-52.5
W-10.
Min. 19/32-
inch
plywood or
1-inch
wood
plank; 2 ft
span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
32 ga., 1-
5/8-inch
diameter tin
caps with 12
ga. annular
ring shank
nails
8-inch o.c. at the
4-inch lap and 8-
inch o.c. in two
staggered center
rows
Min. 1-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation or EnergyGuard
RH Polyiso or min. 1.5-
inch EnergyGuard RA or
EnergyGuard RN
Hot
asphalt
Min. 0.25-inch
DensDeck Prime
or SECUROCK
Gypsum-Fiber
Roof Board
Hot
asphalt
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-52.5
W-11.
Min. 19/32-
inch
plywood or
1-inch
wood
plank; 2 ft
span
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Eliminator Nailable Venting
Base Sheet, Ruberoid 20
Smooth, Ruberoid Mop
Smooth, Ruberoid Mop
Smooth 1.5
32 ga., 1-
5/8-inch dia.
tin caps with
11 ga.
annular ring
shank nails
9-inch o.c. at the
min. 4-inch lap
and 9-inch o.c. in
two, equally
spaced,
staggered center
rows
Min. 1-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation or EnergyGuard
RH Polyiso or min. 1.5-
inch EnergyGuard RA or
EnergyGuard RN
Hot
asphalt
Min. 0.5-inch
Structodek High
Density Fiberboard
Roof Insulation or
EnergyGuard Perlite
Recover Board or
Min. 0.75-inch
EnergyGuard Perlite
Roof Insulation
(homogeneous)
Hot
asphalt
BP-AA,
SBS-AA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-60.0
W-12.
Min. 19/32-
inch
plywood or
1-inch
wood
plank; 2 ft
span
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Eliminator Nailable Venting
Base Sheet, Ruberoid 20
Smooth, Ruberoid Mop
Smooth, Ruberoid Mop
Smooth 1.5
32 ga., 1-
5/8-inch dia.
tin caps with
11 ga.
annular ring
shank nails
9-inch o.c. at the
min. 4-inch lap
and 9-inch o.c. in
two, equally
spaced,
staggered center
rows
Min. 1-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation or EnergyGuard
RH Polyiso or min. 1.5-
inch EnergyGuard RA or
EnergyGuard RN
Hot
asphalt
Min. 0.25-inch
DensDeck Prime
or SECUROCK
Gypsum-Fiber
Roof Board
Hot
asphalt
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-60.0
SELF-ADHERING BASE PLY:
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 9 of 91
TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15)
MDP
(psf) Type Fasteners
(Note 11) Attach Type
Attach
(Notes
6,7,8)
Type
Attach
(Notes
6,7,8)
Base
Ply Ply Cap Ply
W-13.
Min. 19/32-
inch
plywood or
1-inch
wood
plank; 2 ft
span
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Eliminator Nailable Venting
Base Sheet, Ruberoid 20
Smooth, Ruberoid Mop
Smooth, Ruberoid Mop
Smooth 1.5
32 ga., 1-
5/8-inch dia.
tin caps with
11 ga.
annular ring
shank nails
9-inch o.c. at the
min. 2-inch lap
and 12-inch o.c.
in two, equally
spaced,
staggered center
rows
Min. 1-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation or EnergyGuard
RH Polyiso or min. 1.5-
inch EnergyGuard RA or
EnergyGuard RN
Hot
asphalt
Min. 0.25-inch
DensDeck Prime
or SECUROCK
Gypsum-Fiber
Roof Board
Hot
asphalt SBS-SA
(Optional)
SBS-SA,
SBS-TA or
APP-TA
SBS-SA,
SBS-TA
or APP-
TA
-45.0
VENTING SYSTEMS:
W-14.
Min. 15/32-
inch
plywood or
1-inch
wood
plank; 2 ft
span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
32 ga., 1-
5/8-inch dia.
tin caps with
11 ga.
annular ring
shank nails
8-inch o.c. at
min. 4-inch laps
and 8-inch o.c. in
two, equally
spaced,
staggered center
rows
Min. 1-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation or EnergyGuard
RH Polyiso
Hot
asphalt
(Optional)
Additional
layer(s) base
insulation
Hot
asphalt
GAFGLA
S
Stratav
ent
Perfora
ted
Venting
Base
Sheet
(Optional)
BP-AA,
SBS-AA
SBS-AA -45.0
W-15.
Min. 19/32-
inch
plywood or
1-inch
wood
plank; 2 ft
span
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Eliminator Nailable Venting
Base Sheet, Ruberoid 20
Smooth, Ruberoid Mop
Smooth, Ruberoid Mop
Smooth 1.5
32 ga., 1-
5/8-inch dia.
tin caps with
11 ga.
annular ring
shank nails
9-inch o.c. at the
min. 4-inch lap
and 12-inch o.c.
in two, equally
spaced,
staggered center
rows
Min. 1-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation or EnergyGuard
RH Polyiso
Hot
asphalt
(Optional)
Additional
layer(s) base
insulation
Hot
asphalt
GAFGLA
S
Stratav
ent
Perfora
ted
Venting
Base
Sheet
(Optional)
BP-AA,
SBS-AA
SBS-AA -45.0
W-16.
Min. 15/32-
inch
plywood or
1-inch
wood
plank; 2 ft
span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
32 ga., 1-
5/8-inch dia.
tin caps with
11 ga.
annular ring
shank nails
6-inch o.c. at
min. 4-inch laps
and 6-inch o.c. in
two, equally
spaced,
staggered center
rows
Min. 1-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation or EnergyGuard
RH Polyiso
Hot
asphalt
(Optional)
Additional
layer(s) base
insulation
Hot
asphalt
GAFGLA
S
Stratav
ent
Perfora
ted
Venting
Base
Sheet
(Optional)
BP-AA,
SBS-AA
SBS-AA -52.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 10 of 91
TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15)
MDP
(psf) Type Fasteners
(Note 11) Attach Type
Attach
(Notes
6,7,8)
Type
Attach
(Notes
6,7,8)
Base
Ply Ply Cap Ply
W-17.
Min. 19/32-
inch
plywood or
1-inch
wood
plank; 2 ft
span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
32 ga., 1-
5/8-inch
diameter tin
caps with 12
ga. annular
ring shank
nails
8-inch o.c. at the
4-inch lap and 8-
inch o.c. in two
staggered center
rows
Min. 1-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation or EnergyGuard
RH Polyiso
Hot
asphalt
(Optional)
Additional
layer(s) base
insulation
Hot
asphalt
GAFGLA
S
Stratav
ent
Perfora
ted
Venting
Base
Sheet
(Optional)
BP-AA,
SBS-AA
SBS-AA -52.5
W-18.
Min. 19/32-
inch
plywood or
1-inch
wood
plank; 2 ft
span
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Eliminator Nailable Venting
Base Sheet, Ruberoid 20
Smooth, Ruberoid Mop
Smooth, Ruberoid Mop
Smooth 1.5
32 ga., 1-
5/8-inch dia.
tin caps with
11 ga.
annular ring
shank nails
9-inch o.c. at the
min. 4-inch lap
and 9-inch o.c. in
two, equally
spaced,
staggered center
rows
Min. 1-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation or EnergyGuard
RH Polyiso
Hot
asphalt
(Optional)
Additional
layer(s) base
insulation
Hot
asphalt
GAFGLA
S
Stratav
ent
Perfora
ted
Venting
Base
Sheet
(Optional)
BP-AA,
SBS-AA
SBS-AA -60.0
TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15)
MDP
(psf) Type Fasteners
(Note 11) Attach Type
Attach
(Notes
6,7,8)
Type
Attach
(Notes
6,7,8)
Base Ply Ply Cap Ply
CONVENTIONAL SYSTEMS:
W-19.
Min. 19/32-
inch
plywood or
1-inch
wood
plank; 2 ft
span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
Note 2
12-inch o.c. at the
min. 4-inch lap
and 12-inch o.c. in
two, equally
spaced, staggered
center rows
Min. 1-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation or EnergyGuard
RH Polyiso or min. 1.5-
inch EnergyGuard RA or
EnergyGuard RN
Hot
asphalt
Min. 0.5-inch
Structodek High
Density Fiberboard
Roof Insulation or
EnergyGuard
Perlite Recover
Board or Min. 0.75-
inch EnergyGuard
Perlite Roof
Insulation
(homogeneous)
Hot
asphalt
BP-AA, SBS-
AA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-45.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 11 of 91
TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15)
MDP
(psf) Type Fasteners
(Note 11) Attach Type
Attach
(Notes
6,7,8)
Type
Attach
(Notes
6,7,8)
Base Ply Ply Cap Ply
W-20.
Min. 19/32-
inch
plywood or
1-inch
wood
plank; 2 ft
span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
Note 2
12-inch o.c. at the
min. 4-inch lap
and 12-inch o.c. in
two, equally
spaced, staggered
center rows
Min. 1-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation or EnergyGuard
RH Polyiso or min. 1.5-
inch EnergyGuard RA or
EnergyGuard RN
Hot
asphalt
Min. 0.25-inch
DensDeck Prime
or SECUROCK
Gypsum-Fiber
Roof Board
Hot
asphalt
BP-AA, SBS-
AA, SBS-TA,
APP-TA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-45.0
W-21.
Min. 15/32-
inch
plywood or
1-inch
wood
plank; 2 ft
span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
Note 2
(#14
ONLY)
16-inch o.c. at the
min. 4-inch lap
and 16-inch o.c. in
two, equally
spaced, staggered
center rows
Min. 1-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation or EnergyGuard
RH Polyiso or min. 1.5-
inch EnergyGuard RA or
EnergyGuard RN
Hot
asphalt
Min. 0.5-inch
Structodek High
Density Fiberboard
Roof Insulation or
EnergyGuard
Perlite Recover
Board or Min. 0.75-
inch EnergyGuard
Perlite Roof
Insulation
(homogeneous)
Hot
asphalt
BP-AA, SBS-
AA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-52.5
W-22.
Min. 15/32-
inch
plywood or
1-inch
wood
plank; 2 ft
span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
Note 2
(#14
ONLY)
16-inch o.c. at the
min. 4-inch lap
and 16-inch o.c. in
two, equally
spaced, staggered
center rows
Min. 1-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation or EnergyGuard
RH Polyiso or min. 1.5-
inch EnergyGuard RA or
EnergyGuard RN
Hot
asphalt
Min. 0.25-inch
DensDeck Prime
or SECUROCK
Gypsum-Fiber
Roof Board
Hot
asphalt
BP-AA, SBS-
AA, SBS-TA,
APP-TA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-52.5
W-23.
Min. 15/32-
inch
plywood or
1-inch
wood
plank; 2 ft
span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
Note 2
(#14
ONLY)
12-inch o.c. at the
min. 4-inch lap
and 12-inch o.c. in
two, equally
spaced, staggered
center rows
Min. 1-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation or EnergyGuard
RH Polyiso or min. 1.5-
inch EnergyGuard RA or
EnergyGuard RN
Hot
asphalt
Min. 0.5-inch
Structodek High
Density Fiberboard
Roof Insulation or
EnergyGuard
Perlite Recover
Board or Min. 0.75-
inch EnergyGuard
Perlite Roof
Insulation
(homogeneous)
Hot
asphalt
BP-AA, SBS-
AA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-60.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 12 of 91
TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15)
MDP
(psf) Type Fasteners
(Note 11) Attach Type
Attach
(Notes
6,7,8)
Type
Attach
(Notes
6,7,8)
Base Ply Ply Cap Ply
W-24.
Min. 15/32-
inch
plywood or
1-inch
wood
plank; 2 ft
span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
Note 2
(#14
ONLY)
12-inch o.c. at the
min. 4-inch lap
and 12-inch o.c. in
two, equally
spaced, staggered
center rows
Min. 1-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation or EnergyGuard
RH Polyiso or min. 1.5-
inch EnergyGuard RA or
EnergyGuard RN
Hot
asphalt
Min. 0.25-inch
DensDeck Prime
or SECUROCK
Gypsum-Fiber
Roof Board
Hot
asphalt
BP-AA, SBS-
AA, SBS-TA,
APP-TA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-60.0
W-25.
Min. 19/32-
inch
plywood or
1-inch
wood
plank; 2 ft
span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
Note 2
12-inch o.c. at the
min. 2-inch lap
and 12-inch o.c. in
three, equally
spaced, staggered
center rows
Min. 1-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation or EnergyGuard
RH Polyiso or min. 1.5-
inch EnergyGuard RA or
EnergyGuard RN
Hot
asphalt
Min. 0.5-inch
Structodek High
Density Fiberboard
Roof Insulation or
EnergyGuard
Perlite Recover
Board or Min. 0.75-
inch EnergyGuard
Perlite Roof
Insulation
(homogeneous)
Hot
asphalt
BP-AA, SBS-
AA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-60.0
W-26.
Min. 19/32-
inch
plywood or
1-inch
wood
plank; 2 ft
span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
Note 2
12-inch o.c. at the
min. 2-inch lap
and 12-inch o.c. in
three, equally
spaced, staggered
center rows
Min. 1-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation or EnergyGuard
RH Polyiso or min. 1.5-
inch EnergyGuard RA or
EnergyGuard RN
Hot
asphalt
Min. 0.25-inch
DensDeck Prime
or SECUROCK
Gypsum-Fiber
Roof Board
Hot
asphalt
BP-AA, SBS-
AA, SBS-TA,
APP-TA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-60.0
W-27.
Min. 15/32-
inch
plywood or
1-inch
wood
plank; 2 ft
span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
Drill-Tec 3”
Ribbed
Galvalume
Plate (Flat)
with Drill-
Tec #14
Fasteners
or Drill-Tec
#14 HD
Fastener
with Drill-
Tec 3” Flat
Steel Plate
12-inch o.c. at the
min. 4-inch lap
and 12-inch o.c. in
two (2), equally
spaced, staggered
center rows
Min. 1-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation or EnergyGuard
RH Polyiso or min. 1.5-
inch EnergyGuard RA or
EnergyGuard RN
Hot
asphalt
Min. 0.75-inch
EnergyGuard
Perlite Insulation
Hot
asphalt
BP-AA, SBS-
AA
(Optional)
BP-AA,
SBS-AA
SBS-AA -67.5*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 13 of 91
TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15)
MDP
(psf) Type Fasteners
(Note 11) Attach Type
Attach
(Notes
6,7,8)
Type
Attach
(Notes
6,7,8)
Base Ply Ply Cap Ply
W-28.
Min. 15/32-
inch
plywood or
1-inch
wood
plank; 2 ft
span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
Note 2
(#14
ONLY)
8-inch o.c. at the
4-inch lap and 8-
inch o.c. in three
staggered center
rows
Min. 1-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation or EnergyGuard
RH Polyiso or min. 1.5-
inch EnergyGuard RA or
EnergyGuard RN
Hot
asphalt
Min. 0.5-inch
Structodek High
Density Fiberboard
Roof Insulation or
EnergyGuard
Perlite Recover
Board or Min. 0.75-
inch EnergyGuard
Perlite Roof
Insulation
(homogeneous)
Hot
asphalt
BP-AA, SBS-
AA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-75.0*
W-29.
Min. 15/32-
inch
plywood or
1-inch
wood
plank; 2 ft
span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
Note 2
(#14
ONLY)
8-inch o.c. at the
4-inch lap and 8-
inch o.c. in three
staggered center
rows
Min. 1-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation or EnergyGuard
RH Polyiso or min. 1.5-
inch EnergyGuard RA or
EnergyGuard RN
Hot
asphalt
Min. 0.25-inch
DensDeck Prime
or SECUROCK
Gypsum-Fiber
Roof Board
Hot
asphalt
BP-AA, SBS-
AA, SBS-TA,
APP-TA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-82.5
VENTING SYSTEMS:
W-30.
Min. 15/32-
inch
plywood or
1-inch
wood
plank; 2 ft
span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
Note 2
(#14
ONLY)
16-inch o.c. at the
min. 4-inch lap
and 16-inch o.c. in
two, equally
spaced, staggered
center rows
Min. 1-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation or EnergyGuard
RH Polyiso
Hot
asphalt
(Optional)
Additional
layer(s) base
insulation
Hot
asphalt
GAFGLAS
Stratavent
Perforated
Venting
Base Sheet
One or
more BP-
AA, SBS-
AA
SBS-AA,
SBS-TA,
APP-TA
-52.5
W-31.
Min. 15/32-
inch
plywood or
1-inch
wood
plank; 2 ft
span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
Note 2
(#14
ONLY)
12-inch o.c. at the
min. 4-inch lap
and 12-inch o.c. in
two, equally
spaced, staggered
center rows
Min. 1-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation or EnergyGuard
RH Polyiso
Hot
asphalt
(Optional)
Additional
layer(s) base
insulation
Hot
asphalt
GAFGLAS
Stratavent
Perforated
Venting
Base Sheet
One or
more BP-
AA, SBS-
AA
SBS-AA,
SBS-TA,
APP-TA
-60.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 14 of 91
TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15)
MDP
(psf) Type Fasteners
(Note 11) Attach Type
Attach
(Notes
6,7,8)
Type
Attach
(Notes
6,7,8)
Base Ply Ply Cap Ply
W-32.
Min. 15/32-
inch
plywood or
1-inch
wood
plank; 2 ft
span
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
Note 2
(#14
ONLY)
8-inch o.c. at the
4-inch lap and 8-
inch o.c. in three
staggered center
rows
Min. 1-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation or EnergyGuard
RH Polyiso
Hot
asphalt
(Optional)
Additional
layer(s) base
insulation
Hot
asphalt
GAFGLAS
Stratavent
Perforated
Venting
Base Sheet
One or
more BP-
AA, SBS-
AA
SBS-AA,
SBS-TA,
APP-TA
-82.5*
TABLE 1D: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasteners (Note 11) Attach Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
W-33.
Min. 19/32-inch plywood
or 1-inch wood plank; 2 ft
span
Min. 1-inch
EnergyGuard
RN
Drill-Tec #12 Fastener with
Drill-Tec AccuTrac Flat Plate
or AccuTrac Recessed Plate
1 per 1.8
ft2
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA,
APP-TA
SBS-TA,
APP-TA -52.5
TABLE 1E: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer
(Note 13)
Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasteners
(Note 11) Attach Base Ply Ply Cap Ply
CONVENTIONAL SYSTEMS:
W-34. Min. 19/32-inch plywood or
1-inch wood plank; 2 ft span
Min. 0.75-inch, one or
more layers, any
combination, loose laid
Min. 1.5-inch EnergyGuard
Composite or EnergyGuard RA
Composite
Note 2 1 per 3.0 ft2 BP-AA, SBS-AA
(Optional) BP-
AA, SBS-AA,
SBS-TA, APP-TA
SBS-AA,
SBS-TA,
APP-TA
-45.0
W-35. Min. 19/32-inch plywood or
1-inch wood plank; 2 ft span
Min. 0.75-inch, one or
more layers, any
combination, loose laid
Min. 1-inch Structodek High Density
Fiberboard Roof Insulation or min.
0.75-inch EnergyGuard Perlite Roof
Insulation (homogeneous)
Note 2 1 per 2.0 ft2 BP-AA, SBS-AA
(Optional) BP-
AA, SBS-AA,
SBS-TA, APP-TA
SBS-AA,
SBS-TA,
APP-TA
-45.0
W-36. Min. 19/32-inch plywood or
1-inch wood plank; 2 ft span
(Optional) One or more
layers, any
combination, loose laid
Min. 0.25-inch SECUROCK Gypsum
Fiber Roof Board
Note 2 (#14
only) 1 per 1.8 ft2
BP-AA, SBS-
AA, SBS-TA,
APP-TA
(Optional) BP-
AA, SBS-AA,
SBS-TA, APP-TA
SBS-AA,
SBS-TA,
APP-TA
-60.0
SELF-ADHERING BASE PLY:
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 15 of 91
TABLE 1E: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer
(Note 13)
Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasteners
(Note 11) Attach Base Ply Ply Cap Ply
W-37. Min. 15/32-inch plywood or
1-inch wood plank; 2 ft span
(Optional) One or more
layers, any
combination, loose laid
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
Note 2 (#14
Fasteners only) 1 per 2.0 ft2 SBS-SA (Optional) SBS-
SA SBS-SA -45.0
W-38. Min. 15/32-inch plywood or
1-inch wood plank; 2 ft span
(Optional) One or more
layers, any
combination, loose laid
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
Drill-Tec #12
Fasteners and
Drill-Tec 3”
Steel Plates
1 per 1.8 ft2 SBS-SA (Optional) SBS-
TA, APP-TA
SBS-TA,
APP-TA -52.5
W-39. Min. 15/32-inch plywood or
1-inch wood plank; 2 ft span
(Optional) One or more
layers, any
combination, loose laid
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
Drill-Tec #12
Fasteners and
Drill-Tec 3”
Steel Plates
1 per 1.6 ft2 SBS-SA (Optional) SBS-
TA, APP-TA
SBS-TA,
APP-TA -60.0
VENTING SYSTEMS:
W-40. Min. 15/32-inch plywood or
1-inch wood plank; 2 ft span
(Optional) One or more
layers, any
combination, loose laid
Min. 1.5-inch EnergyGuard Polyiso
Insulation or EnergyGuard Ultra Note 2 1 per 1.3 ft2
GAFGLAS
Stratavent
Perforated
Venting Base
Sheet
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA -60.0*
COLD-APPLIED SYSTEMS:
W-41. Min. 15/32-inch plywood or
1-inch wood plank; 2 ft span
(Optional) One or more
layers, any
combination, loose laid
Min. 0.25-inch SECUROCK Gypsum
Fiber Roof Board
Note 2 (#14
fasteners only) 1 per 2.0 ft2 SBS-CA1 None SBS-CA1 -45.0*
W-42. Min. 15/32-inch plywood or
1-inch wood plank; 2 ft span
(Optional) One or more
layers, any
combination, loose laid
Min. 0.25-inch SECUROCK Gypsum
Fiber Roof Board
Note 2 (#14
fasteners only) 1 per 1.8 ft2 SBS-CA1 None SBS-CA1 -60.0
W-43. Min. 15/32-inch plywood or
1-inch wood plank; 2 ft span
(Optional) One or more
layers, any
combination, loose laid
Min. 0.25-inch SECUROCK Gypsum
Fiber Roof Board
Note 2 (#14
fasteners only) 1 per 1.3 ft2
SBS-CA1 None SBS-CA1 -82.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 16 of 91
TABLE 1F: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP
(psf) Type Attach Type Fasteners
(Note 11) Attach Base Ply Ply Cap Ply
CONVENTIONAL SYSTEMS:
W-44.
Min. 19/32-inch
plywood or 1-inch
wood plank; 2 ft span
Min. 1-inch, one or
more layers, any
combination
Prelim
attach
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base
Sheet, #80 Ultima Base Sheet, Stratavent
Nailable Venting Base Sheet, Ruberoid 20
Smooth
Note 2
12-inch o.c. at min. 2-inch
laps and 12-inch o.c. in two,
equally spaced, staggered
center rows
BP-AA, SBS-
AA
(Optional)
BP-AA, SBS-
AA
SBS-AA,
SBS-TA,
SBS-CA,
APP-TA
-45.0
W-45.
Min. 19/32-inch
plywood or 1-inch
wood plank; 2 ft span
Min. 1-inch, one or
more layers, any
combination
Prelim
attach
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base
Sheet, #80 Ultima Base Sheet, Stratavent
Nailable Venting Base Sheet, Ruberoid 20
Smooth
Note 2
12-inch o.c. at min. 2-inch
laps and 12-inch o.c. in
three, equally spaced,
staggered center rows
BP-AA, SBS-
AA
(Optional)
BP-AA, SBS-
AA
SBS-AA,
SBS-TA,
SBS-CA,
APP-TA
-60.0
W-46.
Min. 19/32-inch
plywood or 1-inch
wood plank; 2 ft span
Min. 1-inch, one or
more layers, any
combination
Prelim
attach
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base
Sheet, #80 Ultima Base Sheet, Stratavent
Nailable Venting Base Sheet, Ruberoid 20
Smooth
Note 2
8-inch o.c. at min. 2-inch
laps and 8-inch o.c. in three,
equally spaced, staggered
center rows
BP-AA, SBS-
AA
(Optional)
BP-AA, SBS-
AA
SBS-AA,
SBS-TA,
SBS-CA,
APP-TA
-75.0
SELF-ADHERING BASE PLY:
W-47.
Min. 15/32-inch
plywood or 1-inch
wood plank; 2 ft span
Min. 1-inch, one or
more layers, any
combination
Loose
laid
Liberty SBS Mechanically Attached Base
Sheet Note 2
8-inch o.c. at min. 3-inch
laps and 8-inch o.c. at two,
equally spaced, staggered
center rows
SBS-SA None SBS-SA -97.5
TABLE 1G: WOOD DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY FASTEDED BASE SHEET, BONDED ROOF COVER
System
No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP
(psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply
CONVENTIONAL SYSTEMS:
W-48.
Min. 15/32-inch
plywood or 1-inch
wood plank; 2 ft span
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS
#80 Ultima Base Sheet, GAFGLAS Stratavent Nailable
Venting Base Sheet, Ruberoid 20 Smooth
32 ga., 1-5/8-inch dia.
tin caps with 11 ga.
annular ring shank nails
8-inch o.c. at min. 4-inch laps and 8-
inch o.c. in two, equally spaced,
staggered center rows
(Optional) BP-
AA, SBS-AA SBS-AA -45.0
W-49.
Min. 19/32-inch
plywood or 1-inch
wood plank; 2 ft span
GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent
Eliminator Nailable Venting Base Sheet, Ruberoid 20
Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5
32 ga., 1-5/8-inch dia.
tin caps with 12 ga.
annular ring shank nails
9-inch o.c. at min. 4-inch laps and 9-
inch o.c. at two, equally spaced,
staggered center rows
(Optional) BP-
AA, SBS-AA SBS-AA -45.0
W-50.
Min. 19/32-inch
plywood or 1-inch
wood plank; 2 ft span
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS
#80 Ultima Base Sheet, GAFGLAS Stratavent Nailable
Venting Base Sheet, Ruberoid 20 Smooth
32 ga., 1-5/8-inch dia.
tin caps with 11 ga.
annular ring shank nails
9-inch o.c. at min. 4-inch laps and 12-
inch o.c. in two, equally spaced,
staggered center rows
BP-AA, SBS-AA SBS-AA, SBS-TA,
SBS-CA, APP-TA -45.0
W-51.
Min. 15/32-inch
plywood or 1-inch
wood plank; 2 ft span
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS
#80 Ultima Base Sheet, GAFGLAS Stratavent Nailable
Venting Base Sheet, Ruberoid 20 Smooth
32 ga., 1-5/8-inch dia.
tin caps with 11 ga.
annular ring shank nails
6-inch o.c. at min. 4-inch laps and 6-
inch o.c. in two, equally spaced,
staggered center rows
(Optional) BP-
AA, SBS-AA SBS-AA -52.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 17 of 91
TABLE 1G: WOOD DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY FASTEDED BASE SHEET, BONDED ROOF COVER
System
No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP
(psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply
W-52.
Min. 19/32-inch
plywood or 1-inch
wood plank; 2 ft span
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS
#80 Ultima Base Sheet, GAFGLAS Stratavent Nailable
Venting Base Sheet, Ruberoid 20 Smooth
32 ga., 1-5/8-inch dia.
tin caps with 11 ga.
annular ring shank nails
9-inch o.c. at min. 4-inch laps and 9-
inch o.c. in two, equally spaced,
staggered center rows
BP-AA, SBS-AA SBS-AA, SBS-TA,
SBS-CA, APP-TA -52.5
W-53.
Min. 19/32-inch
plywood or 1-inch
wood plank; 2 ft span
GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent
Eliminator Nailable Venting Base Sheet, Ruberoid 20
Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5
32 ga., 1-5/8-inch dia.
tin caps with 11 ga.
annular ring shank nails
9-inch o.c. at min. 4-inch laps and 9-
inch o.c. in two, equally spaced,
staggered center rows
(Optional) APP-
TA APP-TA -60.0
W-54.
Min. 19/32-inch
plywood or 1-inch
wood plank; 2 ft span
GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent
Eliminator Nailable Venting Base Sheet, Ruberoid 20
Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5
32 ga., 1-5/8-inch dia.
tin caps with 12 ga.
annular ring shank nails
8-inch o.c. at min. 4-inch laps and 8-
inch o.c. at three, equally spaced,
staggered center rows
(Optional) BP-
AA, SBS-AA SBS-AA -75.0
W-55.
Min. 19/32-inch
plywood or 1-inch
wood plank; 2 ft span
GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent
Eliminator Nailable Venting Base Sheet, Ruberoid 20
Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5
32 ga., 1-5/8-inch dia.
tin caps with 11 ga.
annular ring shank nails
7-inch o.c. at min. 4-inch laps and 7-
inch o.c. in three, equally spaced,
staggered center rows
BP-AA, SBS-AA SBS-AA, SBS-TA,
SBS-CA, APP-TA -82.5
W-56.
Min. 19/32-inch
plywood or 1-inch
wood plank; 2 ft span
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS
#80 Ultima Base Sheet, GAFGLAS Stratavent Nailable
Venting Base Sheet, Ruberoid 20 Smooth
32 ga., 1-5/8-inch dia.
tin caps with 11 ga.
annular ring shank nails
4-inch o.c. at min. 2-inch laps and 4-
inch o.c. in four (4), equally spaced,
staggered center rows
(Optional) BP-
AA, SBS-AA,
SBS-TA, APP-TA
SBS-AA, SBS-TA,
APP-TA -97.5
W-57.
Min. 19/32-inch
plywood or 1-inch
wood plank; 2 ft span
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS
#80 Ultima Base Sheet, GAFGLAS Stratavent Nailable
Venting Base Sheet, Ruberoid 20 Smooth
32 ga., 1-5/8-inch dia.
tin caps with 11 ga.
annular ring shank nails
3-inch o.c. at min. 3-inch laps and 3-
inch o.c. at five (5), equally spaced,
staggered center rows. Base sheet
and tin-caps shall be primed with
Matrix 307 Premium Asphalt Primer
prior to base ply installation
(Optional) SBS-
TA
Ruberoid HW Plus
Granule, Ruberoid
HW Plus Granule
FR, Ruberoid
EnergyCap HW Plus
Granule FR
-120.0
SELF-ADHERING BASE PLY:
W-58.
Min. 19/32-inch
plywood or 1-inch
wood plank; 2 ft span
Liberty SBS Mechanically Attached Base Sheet
32 ga., 1-5/8-inch dia.
tin caps with 11 ga.
annular ring shank nails
9-inch o.c. at min. 4-inch laps and 9-
inch o.c. in two, equally spaced,
staggered center rows
(Optional) SBS-
SA
SBS-SA, SBS-TA or
APP-TA -37.5
W-59.
Min. 15/32-inch
plywood or 1-inch
wood plank; 2 ft span
Liberty SBS Mechanically Attached Base Sheet
32 ga., 1-5/8-inch dia.
tin caps with 11 ga.
annular ring shank nails
8-inch o.c. at min. 3-inch laps and 8-
inch o.c. in three, equally spaced,
staggered center rows
(Optional) SBS-
SA
SBS-SA, SBS-TA or
APP-TA -45.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 18 of 91
TABLE 1H: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY FASTEDED BASE SHEET, BONDED ROOF COVER
System
No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP
(psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply
CONVENTIONAL SYSTEMS:
W-60.
Min. 19/32-inch plywood
or 1-inch wood plank; 2
ft span
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent
Nailable Venting Base Sheet, Ruberoid 20 Smooth
Note 2
12-inch o.c. at 2-inch laps and 12-
inch o.c. in two, equally spaced,
staggered center rows
BP-AA, SBS-
AA
SBS-AA, SBS-TA, SBS-CA,
APP-TA -45.0
W-61.
Min. 15/32-inch plywood
or 1-inch wood plank; 2
ft span
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent
Nailable Venting Base Sheet, Ruberoid 20 Smooth
Note 2 (#14 ONLY)
16-inch o.c. at 4-inch laps and 16-
inch o.c. in two, equally spaced,
staggered center rows
(Optional)
BP-AA, SBS-
AA
SBS-AA -52.5
W-62.
Min. 15/32-inch plywood
or 1-inch wood plank; 2
ft span
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent
Nailable Venting Base Sheet, Ruberoid 20 Smooth
Note 2 (#14 ONLY)
12-inch o.c. at 4-inch laps and 12-
inch o.c. in two, equally spaced,
staggered center rows
(Optional)
BP-AA, SBS-
AA
SBS-AA -60.0
W-63.
Min. 19/32-inch plywood
or 1-inch wood plank; 2
ft span
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent
Nailable Venting Base Sheet, Ruberoid 20 Smooth
Note 2
12-inch o.c. at 2-inch laps and 12-
inch o.c. in three, equally spaced,
staggered center rows
BP-AA, SBS-
AA
SBS-AA, SBS-TA, SBS-CA,
APP-TA -60.0
W-64.
Min. 19/32-inch plywood
or 1-inch wood plank; 2
ft span
GAFGLAS #80 Ultima Base Sheet, Ruberoid 20 Smooth,
Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 Note 2
9-inch o.c. at 4-inch laps and 9-inch
o.c. in two, equally spaced,
staggered center rows
(Optional)
SBS-TA SBS-TA (polyester only) -60.0
W-65.
Min. 15/32-inch plywood
or 1-inch wood plank; 2
ft span
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent
Nailable Venting Base Sheet, Ruberoid 20 Smooth
Note 2 (#14 ONLY)
8-inch o.c. at 4-inch laps and 8-inch
o.c. in three, equally spaced,
staggered center rows
(Optional)
BP-AA, SBS-
AA
SBS-AA -97.5
W-66.
Min. 19/32-inch plywood
or 1-inch wood plank; 2
ft span
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent
Nailable Venting Base Sheet, Ruberoid 20 Smooth
Note 2
8-inch o.c. at 2-inch laps and 8-inch
o.c. in three, equally spaced,
staggered center rows
BP-AA, SBS-
AA
SBS-AA, SBS-TA, SBS-CA,
APP-TA -105.0
SELF-ADHERING BASE PLY:
W-67.
Min. 19/32-inch plywood
or 1-inch wood plank; 2
ft span
StormSafe Anchor Sheet
Note 2 (Drill-Tec AccuTrac
Flat Plate, Drill-Tec 3” Flat
Steel Plate or Drill-Tec 3”
Recessed Steel Plate only)
9-inch o.c. at 4-inch laps and 9-inch
o.c. in three, equally spaced,
staggered center rows
(Optional)
SBS-SA
SBS-SA
Note: Seams sealed with
TOPCOAT SB900 or Flexseal
-60.0
W-68.
Min. 15/32-inch plywood
or 1-inch wood plank; 2
ft span
Liberty SBS Mechanically Attached Base Sheet Note 2 (HD Fasteners
only)
8-inch o.c. at 3-inch laps and 8-inch
o.c. in two, equally spaced,
staggered center rows
(Optional)
SBS-SA
SBS-SA, SBS-TA or APP-
TA -60.0
TABLE 1I: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER
System
No. Deck (Note 1) Primer Roof Cover (Note 15) MDP
(psf) Base Ply Cap Ply
W-69. Min. 15/32-inch plywood or 1-inch wood plank; 2
ft span, 8d rink shank nails, 6” o.c. Matrix 307 Premium Asphalt Primer at 1.0 gal/square None SBS-SA -75.0
W-70. Min. 15/32-inch plywood or 1-inch wood plank; 2
ft span, #8 x 2½” deck screws, 6” o.c. Matrix 307 Premium Asphalt Primer at 1.0 gal/square None SBS-SA -90.0
W-71. Min. 15/32-inch plywood or 1-inch wood plank; 2
ft span, 8d rink shank nails, 6” o.c. Matrix 307 Premium Asphalt Primer at 1.0 gal/square SBS-SA SBS-SA -90.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 19 of 91
TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasten
(Note 11) Attach Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
CONVENTIONAL SYSTEMS:
SC-1
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 1.5-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
Note 2 1 per
4.0 ft2
Optional additional layers, min. 1.5-inch base insulation
followed by min. 0.75-inch EnergyGuard Perlite Roof
Insulation (homogeneous) or min. 0.5-inch Structodek
High Density Fiberboard Roof Insulation or EnergyGuard
Perlite Recover Board or min. 0.25-inch DensDeck,
DensDeck Prime or SECUROCK Gypsum Fiber Roof Board
Hot asphalt BP-AA, SBS-
AA
(Optional)
One or more
BP-AA, SBS-
AA
SBS-AA -37.5*
SC-2
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 0.625-inch DensDeck
Prime Note 2 1 per
4.0 ft2
Min. 1.5-inch EnergyGuard followed by min. 0.25-inch
DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt APP-TA (Optional)
APP-TA APP-TA -45.0*
SC-3
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 0.5-inch DensDeck
Prime Note 2 1 per
2.7 ft2
Min. 1.5-inch EnergyGuard followed by min. 0.25-inch
DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt APP-TA (Optional)
APP-TA APP-TA -45.0*
SC-4
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 1.5-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
Note 2 1 per
2.7 ft2
Optional additional layers, min. 1.5-inch base insulation
followed by min. 0.75-inch EnergyGuard Perlite Roof
Insulation (homogeneous) or min. 0.5-inch Structodek
High Density Fiberboard Roof Insulation or EnergyGuard
Perlite Recover Board or min. 0.25-inch DensDeck,
DensDeck Prime or SECUROCK Gypsum Fiber Roof Board
Hot asphalt BP-AA, SBS-
AA
(Optional)
One or more
BP-AA, SBS-
AA
SBS-AA -45.0*
SC-5
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 1.5-inch EnergyGuard
RA, EnergyGuard RH,
EnergyGuard RN
Note 2 1 per
2.0 ft2
Optional additional layers, min. 1.5-inch base insulation
followed by min. 0.75-inch EnergyGuard Perlite Roof
Insulation (homogeneous) or min. 0.5-inch Structodek
High Density Fiberboard Roof Insulation or EnergyGuard
Perlite Recover Board or min. 0.25-inch DensDeck,
DensDeck Prime or SECUROCK Gypsum Fiber Roof Board
Hot asphalt BP-AA, SBS-
AA
(Optional)
One or more
BP-AA, SBS-
AA
SBS-AA -45.0*
SC-6
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra,
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN
Note 2 1 per
4.0 ft2
Optional additional layers, min. 1.5-inch base insulation
followed by min. 0.75-inch EnergyGuard Perlite Roof
Insulation (homogeneous) or min. 0.5-inch Structodek
High Density Fiberboard Roof Insulation or EnergyGuard
Perlite Recover Board or min. 0.25-inch DensDeck,
DensDeck Prime or SECUROCK Gypsum Fiber Roof Board
Hot asphalt BP-AA, SBS-
AA
(Optional)
One or more
BP-AA, SBS-
AA
SBS-AA -45.0*
SC-7
Min. 22 ga., type B,
Grade 50 steel or
min. 2,500 psi
structural concrete
Min. 1.5-inch EnergyGuard
Polyiso Insulation or
EnergyGuard Ultra
Note 2 1 per
1.8 ft2
Min. 0.75-inch EnergyGuard Perlite Roof Insulation
(homogeneous), min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation or EnergyGuard Perlite
Recover Board or min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof Board
Hot asphalt BP-AA, SBS-
AA
(Optional)
BP-AA, SBS-
AA
SBS-AA -60.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 20 of 91
TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasten
(Note 11) Attach Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
SC-8
Min. 22 ga., type B,
Grade 50 steel or
min. 2,500 psi
structural concrete
Min. 1.5-inch EnergyGuard
Polyiso Insulation or
EnergyGuard Ultra
Note 2 1 per
1.8 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-TA or
APP-TA
(Optional)
SBS-TA or
APP-TA
SBS-TA or
APP-TA -60.0*
SC-9
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra,
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN
Note 2 1 per
1.5 ft2
Min. 1.0-inch EnergyGuard Perlite Roof Insulation
(homogeneous) Hot asphalt BP-AA, SBS-
AA
(Optional)
BP-AA, SBS-
AA
SBS-AA or
SBS-TA -60.0
SC-10
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 1.5-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra Polyiso
Insulation, EnergyGuard
RH, EnergyGuard RN
Note 2 1 per
1.3 ft2
Optional additional layers base insulation followed by
min. 0.75-inch EnergyGuard Perlite Roof Insulation
(homogeneous), min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation or EnergyGuard Perlite
Recover Board, min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof Board
Hot asphalt BP-AA or
SBS-AA
(Optional)
BP-AA, SBS-
AA, SBS-TA
SBS-AA,
SBS-TA -60.0
SC-11
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra,
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN
Note 2 1 per
1.5 ft2
Min. 0.5-inch Structodek High Density Fiberboard Roof
Insulation Hot asphalt BP-AA, SBS-
AA
(Optional)
BP-AA, SBS-
AA
SBS-AA or
SBS-TA -67.5
SC-12
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 1.5-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra,
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN
Note 2 1 per
2.0 ft2
Optional additional layers of base insulation; Min. 0.25-
inch DensDeck, DensDeck Prime or SECUROCK Gypsum-
Fiber Roof Board
Hot
asphalt,
GAF 2-Part,
OB500
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional)
One or more
BP-AA, SBS-
AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
SC-13
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra,
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN
Note 2 1 per
4.0 ft2
Optional additional layers of base insulation; Min. 0.25-
inch DensDeck, DensDeck Prime or SECUROCK Gypsum-
Fiber Roof Board
Hot
asphalt,
GAF 2-Part,
OB500
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional)
One or more
BP-AA, SBS-
AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 21 of 91
TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasten
(Note 11) Attach Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
SC-14
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 1.5-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra,
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN
Note 2 1 per
2.0 ft2
Min. 0.5-inch Structodek High Density Fiberboard Roof
Insulation
Hot
asphalt,
GAF 2-Part
or OB500
BP-AA, SBS-
AA None SBS-CA -45.0*
SC-15
Min. 22 ga., type B,
Grade 50 steel or
min. 2,500 psi
structural concrete
Min. 1.5-inch EnergyGuard
Polyiso Insulation or
EnergyGuard Ultra
Note 2 1 per
1.8 ft2
Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-
Fiber Roof Board OB500 SBS-TA or
APP-TA
(Optional)
SBS-TA or
APP-TA
SBS-TA or
APP-TA -52.5
SC-16
Min. 22 ga., type B,
Grade 50 steel or
min. 2,500 psi
structural concrete
Min. 1.5-inch EnergyGuard
Polyiso Insulation or
EnergyGuard Ultra
Note 2 1 per
1.8 ft2
Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-
Fiber Roof Board OB500 BP-AA or
SBS-AA
(Optional)
BP-AA or
SBS-AA
SBS-AA -52.5
SC-17
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra,
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN
Note 2 1 per
1.6 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
Hot
asphalt,
GAF 2-Part,
OB500
BP-AA, SBS-
AA, SBS-TA
or APP-TA
(Optional)
One or more
BP-AA, SBS-
AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-60.0
SELF-ADHERING BASE PLY:
SC-18
Min. 22 ga., Type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 1.5-EnergyGuard RH,
EnergyGuard Polyiso
Insulation, EnergyGuard
Ultra
Note 2 1 per
2.0 ft2
Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation,
EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus
Polyiso Insulation
OB500,
LRF-M, M-
OSFA
SBS-SA
(Optional)
SBS-TA, APP-
TA
SBS-TA,
APP-TA -37.5*
SC-19
Min. 22 ga., Type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 2-EnergyGuard RH,
EnergyGuard Polyiso
Insulation, EnergyGuard
Ultra
Note 2 1 per
2.9 ft2
Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation,
EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus
Polyiso Insulation
OB500,
LRF-M, M-
OSFA
SBS-SA
(Optional)
SBS-TA, APP-
TA
SBS-TA,
APP-TA -37.5*
SC-20
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 1.5-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
Note 2 1 per
2.0 ft2 Additional layer(s), min. 0.5-inch thick base insulation
OB500,
LRF-M, M-
OSFA
SBS-SA
(Optional)
SBS-TA, APP-
TA
SBS-TA,
APP-TA -45.0*
SC-21
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
Note 2 1 per
2.9 ft2 Additional layer(s), min. 0.5-inch thick base insulation
OB500,
LRF-M, M-
OSFA
SBS-SA
(Optional)
SBS-TA, APP-
TA
SBS-TA,
APP-TA -45.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 22 of 91
TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasten
(Note 11) Attach Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
SC-22
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
Note 2 1 per
4.0 ft2 Additional layer(s), min. 1.5-inch thick base insulation
OB500,
LRF-M, M-
OSFA
SBS-SA
(Optional)
SBS-TA, APP-
TA
SBS-TA,
APP-TA -45.0*
SC-23
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 1.5-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra,
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN
Note 2 1 per
2.0 ft2
Optional additional layers of base insulation; Min. 0.25-
inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof
Board
OB500 SBS-SA
(Optional)
SBS-TA, APP-
TA
SBS-TA,
APP-TA -45.0*
SC-24
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 1.5-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
Note 2 1 per
2.0 ft2
Additional optional layers, min. 0.5-inch base insulation
followed by Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500,
LRF-M, M-
OSFA
SBS-SA
(Optional)
SBS-TA, APP-
TA
SBS-TA,
APP-TA -45.0*
SC-25
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
Note 2 1 per
2.9 ft2
Additional optional layers, min. 0.5-inch base insulation
followed by Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500,
LRF-M, M-
OSFA
SBS-SA
(Optional)
SBS-TA, APP-
TA
SBS-TA,
APP-TA -45.0*
SC-26
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 2-inch EnergyGuard
RA, EnergyGuard RH,
EnergyGuard RN
Note 2 1 per
4.0 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional)
SBS-SA SBS-SA -45.0*
SC-27
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 2-inch EnergyGuard
RA, EnergyGuard RH,
EnergyGuard RN
Note 2 1 per 4
ft2
Optional additional layers of base insulation; Min. 0.25-
inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof
Board
OB500 SBS-SA
(Optional)
SBS-TA, APP-
TA
SBS-TA,
APP-TA -45.0*
SC-28
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
Note 2 1 per
4.0 ft2
Additional optional layers, min. 0.5-inch base insulation
followed by Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500,
LRF-M, M-
OSFA
SBS-SA
(Optional)
SBS-TA, APP-
TA
SBS-TA,
APP-TA -45.0*
SC-29
Min. 22 ga., type B,
Grade 50 steel or
min. 2,500 psi
structural concrete
Min. 1.5-inch EnergyGuard
Polyiso Insulation or
EnergyGuard Ultra
Note 2 1 per
1.8 ft2
Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-
Fiber Roof Board OB500 SBS-SA (Optional)
SBS-TA SBS-TA -52.5
SC-30
Min. 22 ga., type B,
Grade 50 steel or
min. 2,500 psi
structural concrete
Min. 1.5-inch EnergyGuard
Polyiso Insulation or
EnergyGuard Ultra
Note 2 1 per
1.8 ft2
Min. 0.5-inch EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation OB500 SBS-SA (Optional)
SBS-TA SBS-TA -60.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 23 of 91
TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasten
(Note 11) Attach Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
SC-31
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra,
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN
Note 2 1 per
1.6 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA
(Optional)
SBS-TA, APP-
TA
SBS-TA,
APP-TA -60.0
SC-32
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra,
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN
Note 2 1 per
4.0 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
Hot
asphalt,
GAF 2-Part
SBS-SA (Optional)
SBS-SA SBS-SA -45.0*
SC-33
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 1.5-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra,
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN
Note 2 1 per
2.0 ft2
Optional additional layers of base insulation; Min. 0.25-
inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof
Board
Hot
asphalt,
GAF 2-Part
SBS-SA
(Optional)
SBS-TA, APP-
TA
SBS-TA,
APP-TA -45.0*
SC-34
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra,
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN
Note 2 1 per
4.0 ft2
Optional additional layers of base insulation; Min. 0.25-
inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof
Board
Hot
asphalt,
GAF 2-Part
SBS-SA
(Optional)
SBS-TA, APP-
TA
SBS-TA,
APP-TA -45.0*
SC-35
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra,
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN
Note 2 1 per
1.6 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
Hot
asphalt,
GAF 2-Part
SBS-SA
(Optional)
SBS-TA, APP-
TA
SBS-TA,
APP-TA -60.0
VENTING SYSTEMS:
SC-36
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 1.5-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
Note 2 1 per
4.0 ft2 Additional layer of base insulation Hot asphalt
GAFGLAS
Stratavent
Perforated
Venting
Base Sheet
(Optional)
One or more
BP-AA, SBS-
AA
SBS-AA -45.0*
COLD-APPLIED SYSTEMS:
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 24 of 91
TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasten
(Note 11) Attach Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
SC-37
Min. 22 ga., Type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 1.5-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra,
EnergyGuard RH
Note 2 1 per
2.0 ft2
Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation,
EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus
Polyiso Insulation
OB500,
LRF-M, M-
OSFA
SBS-CA or
SBS-CA1 None SBS-CA or
SBS-CA1 -37.5*
SC-38
Min. 22 ga., Type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra,
EnergyGuard RH
Note 2 1 per
2.9 ft2
Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation,
EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus
Polyiso Insulation
OB500,
LRF-M, M-
OSFA
SBS-CA or
SBS-CA1 None SBS-CA or
SBS-CA1 -37.5*
SC-39
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 1.5-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra,
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN
Note 2 1 per
2.0 ft2
Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-
Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -45.0*
SC-40
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra,
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN
Note 2 1 per
4.0 ft2
Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-
Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -45.0*
SC-41
Min. 22 ga., type B,
Grade 50 steel or
min. 2,500 psi
structural concrete
Min. 1.5-inch EnergyGuard
Polyiso Insulation or
EnergyGuard Ultra
Note 2 1 per
1.8 ft2
Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-
Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -52.5
HYBRID HOT/COLD-APPLIED SYSTEMS:
SC-42
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 1.5-inch EnergyGuard
RH, EnergyGuard RN Note 2 1 per
2.0 ft2
Optional additional layers base insulation followed by
min. 0.75-inch EnergyGuard Perlite Roof Insulation
(homogeneous), min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation or EnergyGuard Perlite
Recover Board, min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof Board
Hot asphalt BP-AA or
SBS-AA
(Optional)
BP-AA or
SBS-AA
SBS-CA1 -45.0*
SC-43
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 1.5-inch EnergyGuard
Polyiso Insulation Note 2 1 per
2.7 ft2
Optional additional layers base insulation followed by
min. 0.75-inch EnergyGuard Perlite Roof Insulation
(homogeneous) or min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
Hot asphalt BP-AA or
SBS-AA
(Optional)
BP-AA or
SBS-AA
SBS-CA1 -45.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 25 of 91
TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasten
(Note 11) Attach Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
SC-44
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 1.5-inch EnergyGuard
Polyiso Insulation Note 2 1 per
3.2 ft2
Optional additional layers base insulation followed by
min.0.5-inch EnergyGuard Perlite Recover Board, min.
0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber
Roof Board
Hot asphalt BP-AA or
SBS-AA
(Optional)
BP-AA or
SBS-AA
SBS-CA1 -45.0*
SC-45
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 1.5-inch EnergyGuard
Polyiso Insulation Note 2 1 per
4.0 ft2
Optional additional layers base insulation followed by
min. 0.75-inch EnergyGuard Perlite Roof Insulation
(homogeneous), min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation or EnergyGuard Perlite
Recover Board, min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof Board
Hot asphalt BP-AA or
SBS-AA
(Optional)
BP-AA or
SBS-AA
SBS-CA1 -45.0*
SC-46
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 2-inch EnergyGuard
RH, EnergyGuard RN Note 2 1 per
3.2 ft2
Optional additional layers base insulation followed by
min. 0.75-inch EnergyGuard Perlite Roof Insulation
(homogeneous), min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation or EnergyGuard Perlite
Recover Board, min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof Board
Hot asphalt BP-AA or
SBS-AA
(Optional)
BP-AA or
SBS-AA
SBS-CA1 -45.0*
SC-47
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 2-inch EnergyGuard
RA, EnergyGuard RH,
EnergyGuard RN
Note 2 1 per
4.0 ft2
Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board Hot asphalt BP-AA or
SBS-AA
(Optional)
BP-AA or
SBS-AA
SBS-CA1 -45.0*
SC-48
Min. 22 ga., type B,
Grade 50 steel or
min. 2,500 psi
structural concrete
Min. 1.5-inch EnergyGuard
Polyiso Insulation or
EnergyGuard Ultra
Note 2 1 per
1.8 ft2
Min. 0.75-inch EnergyGuard Perlite Roof Insulation
(homogeneous), min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation or EnergyGuard Perlite
Recover Board or min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof Board
Hot asphalt BP-AA or
SBS-AA
(Optional)
BP-AA or
SBS-AA
SBS-CA1 -60.0*
SC-49
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 1.5-inch EnergyGuard
Polyiso Insulation,
EnergyGuard RH,
EnergyGuard RN
Note 2 1 per
1.3 ft2
Optional additional layers base insulation followed by
min. 0.75-inch EnergyGuard Perlite Roof Insulation
(homogeneous), min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation or EnergyGuard Perlite
Recover Board, min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof Board
Hot asphalt BP-AA or
SBS-AA
(Optional)
BP-AA or
SBS-AA
SBS-CA1 -60.0
SC-50
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 1.5-inch EnergyGuard
RA, EnergyGuard RH,
EnergyGuard RN
Note 2 1 per
2.0 ft2
Additional optional layers, min. 0.5-inch base insulation
followed by min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500 BP-AA or
SBS-AA
(Optional)
BP-AA or
SBS-AA
SBS-CA1 -45.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 26 of 91
TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasten
(Note 11) Attach Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
SC-51
Min. 22 ga., type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 2-inch EnergyGuard
RA, EnergyGuard RH,
EnergyGuard RN
Note 2 1 per
4.0 ft2
Additional optional layers, min. 0.5-inch base insulation
followed by min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500 BP-AA or
SBS-AA
(Optional)
BP-AA or
SBS-AA
SBS-CA1 -45.0*
SC-52
Min. 22 ga., type B,
Grade 50 steel or
min. 2,500 psi
structural concrete
Min. 1.5-inch EnergyGuard
Polyiso Insulation or
EnergyGuard Ultra
Note 2 1 per
1.8 ft2
Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-
Fiber Roof Board OB500 BP-AA or
SBS-AA
(Optional)
BP-AA or
SBS-AA
SBS-CA1 -52.5
TABLE 2B: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF)
SYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED TEMP ROOF, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Thermal Barrier
Temp Roof
Insulation Layer(s) Roof Cover (Note 15) MDP
(psf) Type Fastener
(Note 11) Attach Type Attach
(Notes 6,7,8) Base Ply Cap
CONVENTIONAL SYSTEMS:
SC-53
Min. 22 ga.,
Type B,
Grade 33
steel
0.5-inch DensDeck
Prime or SECUROCK
Gypsum Fiber Roof
Board
Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
1 per
4.0 ft2
Primer: GAF SA Primer or
Matrix 307 Premium
Asphalt Primer
Vapor Retarder: GAF SA
Vapor Retarder, self-
adhering
One or more layers, base layer min. 1-inch
thick, optional subsequent layer(s) min. 1.5-
inch thick EnergyGuard RN
Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
LRF-M or
OB500
SBS-TA or
APP-TA
(Optional)
SBS-TA or
APP-TA
SBS-TA
or APP-
TA
-45.0*
SC-54
Min. 22 ga.,
Type B,
Grade 33
steel
0.5-inch DensDeck
Prime or SECUROCK
Gypsum Fiber Roof
Board
Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
1 per
4.0 ft2
Primer: GAF SA Primer or
Matrix 307 Premium
Asphalt Primer
Vapor Retarder: GAF SA
Vapor Retarder, self-
adhering
One or more layers, base layer min. 1-inch
thick, optional subsequent layer(s) min. 1.5-
inch thick EnergyGuard RN
Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
LRF-M or
OB500
BP-AA or
SBS-AA
(Optional)
BP-AA or
SBS-AA
SBS-AA -45.0*
SC-55
Min. 22 ga.,
Type B,
Grade 33
steel
0.5-inch DensDeck
Prime or SECUROCK
Gypsum Fiber Roof
Board
Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
1 per
4.0 ft2
Primer: GAF SA Primer or
Matrix 307 Premium
Asphalt Primer
Vapor Retarder: GAF SA
Vapor Retarder, self-
adhering
One or more layers, base layer min. 1-inch
thick, optional subsequent layer(s) min. 1.5-
inch thick EnergyGuard Polyiso Insulation,
EnergyGuard Ultra Polyiso Insulation
Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
GAF 2-Part,
LRF-M or
OB500
SBS-TA or
APP-TA
(Optional)
SBS-TA or
APP-TA
SBS-TA
or APP-
TA
-45.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 27 of 91
TABLE 2B: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF)
SYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED TEMP ROOF, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Thermal Barrier
Temp Roof
Insulation Layer(s) Roof Cover (Note 15) MDP
(psf) Type Fastener
(Note 11) Attach Type Attach
(Notes 6,7,8) Base Ply Cap
SC-56
Min. 22 ga.,
Type B,
Grade 33
steel
0.5-inch DensDeck
Prime or SECUROCK
Gypsum Fiber Roof
Board
Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
1 per
4.0 ft2
Primer: GAF SA Primer or
Matrix 307 Premium
Asphalt Primer
Vapor Retarder: GAF SA
Vapor Retarder, self-
adhering
One or more layers, base layer min. 1-inch
thick, optional subsequent layer(s) min. 1.5-
inch thick EnergyGuard Polyiso Insulation,
EnergyGuard Ultra Polyiso Insulation
Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
GAF 2-Part,
LRF-M or
OB500
BP-AA or
SBS-AA
(Optional)
BP-AA or
SBS-AA
SBS-AA -45.0*
SC-57
Min. 22 ga.,
Type B,
Grade 33
steel
0.5-inch DensDeck
Prime or SECUROCK
Gypsum Fiber Roof
Board
Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
1 per
2.0 ft2
Primer: GAF SA Primer
Vapor Retarder: GAF SA
Vapor Retarder, self-
adhering
One or more layers, base layer min. 1-inch
thick, optional subsequent layer(s) min. 1.5-
inch thick EnergyGuard Polyiso Insulation,
EnergyGuard Ultra Polyiso Insulation
Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
GAF 2-Part,
LRF-M or
OB500
SBS-TA or
APP-TA
(Optional)
SBS-TA or
APP-TA
SBS-TA
or APP-
TA
-67.5
SC-58
Min. 22 ga.,
Type B,
Grade 33
steel
0.5-inch DensDeck
Prime or SECUROCK
Gypsum Fiber Roof
Board
Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
1 per
2.0 ft2
Primer: GAF SA Primer
Vapor Retarder: GAF SA
Vapor Retarder, self-
adhering
One or more layers, base layer min. 1-inch
thick, optional subsequent layer(s) min. 1.5-
inch thick EnergyGuard Polyiso Insulation,
EnergyGuard Ultra Polyiso Insulation
Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
GAF 2-Part,
LRF-M or
OB500
BP-AA or
SBS-AA
(Optional)
BP-AA or
SBS-AA
SBS-AA -67.5
SELF-ADHERING BASE PLY:
SC-59
Min. 22 ga.,
Type B,
Grade 33
steel
Min. 0.5-inch
SECUROCK Gypsum
Fiber Roof Board
Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
1 per
2.7 ft2
Liberty SBS Self-Adhering
Cap Sheet
Min. 1.5-inch EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN OB500 SBS-SA None SBS-SA -45.0*
SC-60
Min. 22 ga.,
Type B,
Grade 33
steel
Min. 0.5-inch
SECUROCK Gypsum
Fiber Roof Board
Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
1 per
2.7 ft2
Liberty SBS Self-Adhering
Cap Sheet
Min. 1.5-inch EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN OB500 SBS-SA
(Optional)
SBS-TA,
APP-TA
SBS-TA,
APP-TA -45.0*
SC-61
Min. 22 ga.,
Type B,
Grade 33
steel
Min. 0.5-inch
SECUROCK Gypsum
Fiber Roof Board
Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
1 per
2.7 ft2
Liberty SBS Self-Adhering
Cap Sheet
Min. 1.5-inch EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN followed by min. 0.25-
inch SECUROCK Gypsum-Fiber Roof Board
OB500 SBS-SA None SBS-SA -45.0*
SC-62
Min. 22 ga.,
Type B,
Grade 33
steel
Min. 0.5-inch
SECUROCK Gypsum
Fiber Roof Board
Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
1 per
2.7 ft2
Liberty SBS Self-Adhering
Cap Sheet
Min. 1.5-inch EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN followed by min. 0.25-
inch DensDeck Prime or SECUROCK Gypsum-
Fiber Roof Board
OB500 SBS-SA
(Optional)
SBS-TA,
APP-TA
SBS-TA,
APP-TA -45.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 28 of 91
TABLE 2B: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF)
SYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED TEMP ROOF, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Thermal Barrier
Temp Roof
Insulation Layer(s) Roof Cover (Note 15) MDP
(psf) Type Fastener
(Note 11) Attach Type Attach
(Notes 6,7,8) Base Ply Cap
SC-63
Min. 22 ga.,
Type B,
Grade 33
steel
Min. 0.5-inch
SECUROCK Gypsum
Fiber Roof Board
Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
1 per
2.7 ft2
Liberty SBS Self-Adhering
Cap Sheet
Min. 1.5-inch EnergyGuard RH followed by
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
OB500 SBS-SA
(Optional)
SBS-TA,
APP-TA
SBS-TA,
APP-TA -45.0*
SC-64
Min. 22 ga.,
Type B,
Grade 33
steel
0.5-inch DensDeck
Prime or SECUROCK
Gypsum Fiber Roof
Board
Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
1 per
4.0 ft2
Primer: GAF SA Primer or
Matrix 307 Premium
Asphalt Primer
Vapor Retarder: GAF SA
Vapor Retarder, self-
adhering
One or more layers, base layer min. 1-inch
thick, optional subsequent layer(s) min. 1.5-
inch thick EnergyGuard RN
(Optional) Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof Board or min.
0.5-inch EnergyGuard HD Polyiso Insulation or
EnergyGuard HD Plus Polyiso Insulation
LRF-M or
OB500 SBS-SA
(Optional)
SBS-TA,
APP-TA
SBS-TA,
APP-TA -45.0*
SC-65
Min. 22 ga.,
Type B,
Grade 33
steel
0.5-inch DensDeck
Prime or SECUROCK
Gypsum Fiber Roof
Board
Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
1 per
4.0 ft2
Primer: GAF SA Primer or
Matrix 307 Premium
Asphalt Primer
Vapor Retarder: GAF SA
Vapor Retarder, self-
adhering
One or more layers, base layer min. 1-inch
thick, optional subsequent layer(s) min. 1.5-
inch thick EnergyGuard Polyiso Insulation,
EnergyGuard Ultra Polyiso Insulation
(Optional) Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof Board or min.
0.5-inch EnergyGuard HD Polyiso Insulation or
EnergyGuard HD Plus Polyiso Insulation
GAF 2-Part,
LRF-M or
OB500
SBS-SA
(Optional)
SBS-TA,
APP-TA
SBS-TA,
APP-TA -45.0*
SC-66
Min. 22 ga.,
Type B,
Grade 33
steel
0.5-inch DensDeck
Prime or SECUROCK
Gypsum Fiber Roof
Board
Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
1 per
2.0 ft2
Primer: GAF SA Primer
Vapor Retarder: GAF SA
Vapor Retarder, self-
adhering
One or more layers, base layer min. 1-inch
thick, optional subsequent layer(s) min. 1.5-
inch thick EnergyGuard Polyiso Insulation,
EnergyGuard Ultra Polyiso Insulation
(Optional) Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof Board or min.
0.5-inch EnergyGuard HD Polyiso Insulation or
EnergyGuard HD Plus Polyiso Insulation
GAF 2-Part,
LRF-M or
OB500
SBS-SA
(Optional)
SBS-TA,
APP-TA
SBS-TA,
APP-TA -67.5
VENTING SYSTEMS:
SC-67
Min. 22 ga.,
Type B,
Grade 33
steel
0.5-inch DensDeck
Prime or SECUROCK
Gypsum Fiber Roof
Board
Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
1 per
4.0 ft2
Primer: GAF SA Primer or
Matrix 307 Premium
Asphalt Primer
Vapor Retarder: GAF SA
Vapor Retarder, self-
adhering
One or more layers, base layer min. 1-inch
thick, optional subsequent layer(s) min. 1.5-
inch thick EnergyGuard RN
(Optional) Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof Board
LRF-M or
OB500
GAFGLAS
Stratavent
Perforated
Venting
Base Sheet
(Optional)
One or
more BP-
AA, SBS-
AA
SBS-AA -45.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 29 of 91
TABLE 2B: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF)
SYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED TEMP ROOF, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Thermal Barrier
Temp Roof
Insulation Layer(s) Roof Cover (Note 15) MDP
(psf) Type Fastener
(Note 11) Attach Type Attach
(Notes 6,7,8) Base Ply Cap
SC-68
Min. 22 ga.,
Type B,
Grade 33
steel
0.5-inch DensDeck
Prime or SECUROCK
Gypsum Fiber Roof
Board
Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
1 per
4.0 ft2
Primer: GAF SA Primer or
Matrix 307 Premium
Asphalt Primer
Vapor Retarder: GAF SA
Vapor Retarder, self-
adhering
One or more layers, base layer min. 1-inch
thick, optional subsequent layer(s) min. 1.5-
inch thick EnergyGuard Polyiso Insulation,
EnergyGuard Ultra Polyiso Insulation
(Optional) Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof Board
GAF 2-Part,
LRF-M or
OB500
GAFGLAS
Stratavent
Perforated
Venting
Base Sheet
(Optional)
One or
more BP-
AA, SBS-
AA
SBS-AA -45.0*
SC-69
Min. 22 ga.,
Type B,
Grade 33
steel
0.5-inch DensDeck
Prime or SECUROCK
Gypsum Fiber Roof
Board
Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
1 per
2.0 ft2
Primer: GAF SA Primer
Vapor Retarder: GAF SA
Vapor Retarder, self-
adhering
One or more layers, base layer min. 1-inch
thick, optional subsequent layer(s) min. 1.5-
inch thick EnergyGuard Polyiso Insulation,
EnergyGuard Ultra Polyiso Insulation
(Optional) Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof Board
GAF 2-Part,
LRF-M or
OB500
GAFGLAS
Stratavent
Perforated
Venting
Base Sheet
(Optional)
One or
more BP-
AA, SBS-
AA
SBS-AA -67.5
COLD-APPLIED SYSTEMS:
SC-70
Min. 22 ga.,
Type B,
Grade 33
steel
Min.0.5-inch
SECUROCK Gypsum
Fiber Roof Board
Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
1 per
2.7 ft2
Liberty SBS Self-Adhering
Cap Sheet
Min. 1.5-inch EnergyGuard RH followed by
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
OB500 SBS-CA or
SBS-CA1 None
SBS-CA
or SBS-
CA1
-45.0*
SC-71
Min. 22 ga.,
Type B,
Grade 33
steel
0.5-inch DensDeck
Prime or SECUROCK
Gypsum Fiber Roof
Board
Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
1 per
4.0 ft2
Primer: GAF SA Primer or
Matrix 307 Premium
Asphalt Primer
Vapor Retarder: GAF SA
Vapor Retarder, self-
adhering
One or more layers, base layer min. 1-inch
thick, optional subsequent layer(s) min. 1.5-
inch thick EnergyGuard RN
(Optional) Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof Board or min.
0.5-inch EnergyGuard HD Polyiso Insulation or
EnergyGuard HD Plus Polyiso Insulation
LRF-M or
OB500 SBS-CA1 None SBS-CA1 -45.0*
SC-72
Min. 22 ga.,
Type B,
Grade 33
steel
0.5-inch DensDeck
Prime or SECUROCK
Gypsum Fiber Roof
Board
Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
1 per
4.0 ft2
Primer: GAF SA Primer or
Matrix 307 Premium
Asphalt Primer
Vapor Retarder: GAF SA
Vapor Retarder, self-
adhering
One or more layers, base layer min. 1-inch
thick, optional subsequent layer(s) min. 1.5-
inch thick EnergyGuard Polyiso Insulation,
EnergyGuard Ultra Polyiso Insulation
(Optional) Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof Board or min.
0.5-inch EnergyGuard HD Polyiso Insulation or
EnergyGuard HD Plus Polyiso Insulation
GAF 2-Part,
LRF-M or
OB500
SBS-CA1 None SBS-CA1 -45.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 30 of 91
TABLE 2B: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF)
SYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED TEMP ROOF, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Thermal Barrier
Temp Roof
Insulation Layer(s) Roof Cover (Note 15) MDP
(psf) Type Fastener
(Note 11) Attach Type Attach
(Notes 6,7,8) Base Ply Cap
SC-73
Min. 22 ga.,
Type B,
Grade 33
steel
0.5-inch DensDeck
Prime or SECUROCK
Gypsum Fiber Roof
Board
Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
1 per
2.0 ft2
Primer: GAF SA Primer
Vapor Retarder: GAF SA
Vapor Retarder, self-
adhering
One or more layers, base layer min. 1-inch
thick, optional subsequent layer(s) min. 1.5-
inch thick EnergyGuard Polyiso Insulation,
EnergyGuard Ultra Polyiso Insulation
(Optional) Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof Board or min.
0.5-inch EnergyGuard HD Polyiso Insulation or
EnergyGuard HD Plus Polyiso Insulation
GAF 2-Part,
LRF-M or
OB500
SBS-CA1 None SBS-CA1 -67.5
HYBRID HOT/COLD APPLIED SYSTEMS:
SC-74
Min. 22 ga.,
Type B,
Grade 33
steel
0.5-inch DensDeck
Prime or SECUROCK
Gypsum Fiber Roof
Board
Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
1 per
4.0 ft2
Primer: GAF SA Primer or
Matrix 307 Premium
Asphalt Primer
Vapor Retarder: GAF SA
Vapor Retarder, self-
adhering
One or more layers, base layer min. 1-inch
thick, optional subsequent layer(s) min. 1.5-
inch thick EnergyGuard RN
Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
LRF-M or
OB500
BP-AA or
SBS-AA
(Optional)
BP-AA or
SBS-AA
SBS-CA1 -45.0*
SC-75
Min. 22 ga.,
Type B,
Grade 33
steel
0.5-inch DensDeck
Prime or SECUROCK
Gypsum Fiber Roof
Board
Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
1 per
4.0 ft2
Primer: GAF SA Primer or
Matrix 307 Premium
Asphalt Primer
Vapor Retarder: GAF SA
Vapor Retarder, self-
adhering
One or more layers, base layer min. 1-inch
thick, optional subsequent layer(s) min. 1.5-
inch thick EnergyGuard Polyiso Insulation,
EnergyGuard Ultra Polyiso Insulation
Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
GAF 2-Part,
LRF-M or
OB500
BP-AA or
SBS-AA
(Optional)
BP-AA or
SBS-AA
SBS-CA1 -45.0*
SC-76
Min. 22 ga.,
Type B,
Grade 33
steel
0.5-inch DensDeck
Prime or SECUROCK
Gypsum Fiber Roof
Board
Note 2
(Drill-Tec 3 in.
Ribbed Galvalume
Plate (Flat) may be
used)
1 per
2.0 ft2
Primer: GAF SA Primer
Vapor Retarder: GAF SA
Vapor Retarder, self-
adhering
One or more layers, base layer min. 1-inch
thick, optional subsequent layer(s) min. 1.5-
inch thick EnergyGuard Polyiso Insulation,
EnergyGuard Ultra Polyiso Insulation
Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
GAF 2-Part,
LRF-M or
OB500
BP-AA or
SBS-AA
(Optional)
BP-AA or
SBS-AA
SBS-CA1 -67.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 31 of 91
TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer
(Note 13)
Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasteners
(Note 11) Attach Base Ply Ply Cap Ply
CONVENTIONAL SYSTEMS:
SC-77
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board Note 2 1 per
4.0 ft2 SBS-TA or APP-TA
(Optional)
SBS-TA or
APP-TA
SBS-TA or
APP-TA -30.0*
SC-78
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board Note 2 1 per
3.2 ft2 SBS-TA or APP-TA
(Optional)
SBS-TA or
APP-TA
SBS-TA or
APP-TA -37.5*
SC-79
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.625-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board Note 2 1 per
4.0 ft2 SBS-TA or APP-TA
(Optional)
SBS-TA or
APP-TA
SBS-TA or
APP-TA -45.0*
SC-80
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board Note 2 1 per
2.13 ft2 SBS-TA or APP-TA
(Optional)
SBS-TA or
APP-TA
SBS-TA or
APP-TA -45.0*
SC-81
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.5-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board Note 2 1 per
3.2 ft2 SBS-TA or APP-TA
(Optional)
SBS-TA or
APP-TA
SBS-TA or
APP-TA -45.0*
SC-82
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid Min. 0.25-inch DensDeck, DensDeck Prime Note 2 1 per
4.0 ft2 BP-AA, SBS-AA (Optional) BP-
AA, SBS-AA
SBS-AA,
SBS-TA,
APP-TA
-45.0*
SC-83
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.5-inch Structodek High Density Fiberboard
Roof Insulation or Structodek High Density
Fiberboard Roof Insulation
Note 2 1 per
2.0 ft2 SBS-AA (Optional)
SBS-AA
SBS-AA,
SBS-TA -45.0*
SC-84
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board Note 2 1 per
2.0 ft2
BP-AA, SBS-AA, SBS-
TA or APP-TA
(Optional) BP-
AA, SBS-AA,
SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
SC-85
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board Note 2 1 per
4.0 ft2 BP-AA or SBS-AA
(Optional) BP-
AA, SBS-AA,
SBS-TA
SBS-AA,
SBS-TA -45.0*
SC-86
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board Note 2 1 per
1.6 ft2
SBS-AA, SBS-TA, APP-
TA
(Optional)
SBS-AA, SBS-
TA, APP-TA
SBS-AA,
SBS-TA,
APP-TA
-52.5
SC-87
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid Min. 0.25-inch DensDeck Prime Note 2 1 per
1.5 ft2
SBS-AA, SBS-TA, APP-
TA
(Optional)
SBS-AA, SBS-
TA, APP-TA
SBS-AA,
SBS-TA,
APP-TA
-52.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 32 of 91
TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer
(Note 13)
Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasteners
(Note 11) Attach Base Ply Ply Cap Ply
SC-88
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per
1.8 ft2 SBS-TA, APP-TA
(Optional)
SBS-TA, APP-
TA
SBS-TA,
APP-TA -52.5
SC-89
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 (#14
only)
1 per
1.8 ft2 BP-AA, SBS-AA
(Optional) BP-
AA, SBS-AA,
SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-60.0
SC-90
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board Note 2 1 per
1.3 ft2 SBS-TA, APP-TA
(Optional)
SBS-TA, APP-
TA
SBS-TA,
APP-TA -60.0
SC-91
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.5-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board Note 2 1 per
2.0 ft2 BP-AA or SBS-AA
(Optional) BP-
AA, SBS-AA,
SBS-TA
SBS-AA,
SBS-TA -60.0
SC-92
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.5-inch Structodek High Density Fiberboard
Roof Insulation Note 2 1 per
1.0 ft2 SBS-AA
(Optional)
SBS-AA or
SBS-TA
SBS-AA,
SBS-TA -67.5
SC-93
Min. 22 ga., type B, Grade
40 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid Min. 0.25-inch DensDeck Prime Note 2 1 per
1.5 ft2 SBS-TA (Optional)
SBS-TA SBS-TA -67.5
SC-94
Min. 22 ga., Type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.375-inch SECUROCK Gypsum-Fiber Roof
Board Note 2 1 per
1.3 ft2 SBS-TA, APP-TA
(Optional)
SBS-TA, APP-
TA
SBS-TA,
APP-TA -67.5
SC-95
Min. 22 ga., type B, Grade
40 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board Note 2 1 per
1.5 ft2 SBS-TA (Optional)
SBS-TA SBS-TA -75.0
SC-96
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.5-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board Note 2 1 per
1.6 ft2 BP-AA or SBS-AA
(Optional) BP-
AA, SBS-AA,
SBS-TA
SBS-AA,
SBS-TA -82.5
SC-97
Min. 20 ga., type B, Grade
33 steel, min. 22 ga., type
B, Grade 80 steel or min.
2,500 psi structural
concrete
One or more layers, any
combination, loose laid
Min. 0.5-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board Note 2 1 per
1.6 ft2 BP-AA or SBS-AA
(Optional) BP-
AA, SBS-AA,
SBS-TA
SBS-AA,
SBS-TA -90.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 33 of 91
TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer
(Note 13)
Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasteners
(Note 11) Attach Base Ply Ply Cap Ply
SC-98
Min. 20 ga., type B, Grade
33 steel or min. 22 ga.,
type B, Grade 80 steel or
min. 2,500 psi structural
concrete
One or more layers, any
combination, loose laid Min. 0.5-inch DensDeck Prime Note 2 1 per
1.0 ft2 SBS-TA, APP-TA
(Optional)
SBS-TA, APP-
TA
SBS-TA,
APP-TA -90.0
SC-99
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per
1.0 ft2 SBS-TA, APP-TA
(Optional)
SBS-TA, APP-
TA
SBS-TA,
APP-TA -97.5
SC-100
Min. 20 ga., type B, Grade
33 steel, min. 22 ga., type
B, Grade 80 steel or min.
2,500 psi structural
concrete
One or more layers, any
combination, loose laid
Min. 0.5-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board Note 2 1 per
1.5 ft2 BP-AA or SBS-AA
(Optional) BP-
AA, SBS-AA,
SBS-TA
SBS-AA,
SBS-TA -97.5
SC-101
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid Min. 0.5-inch DensDeck Prime Note 2 (#14
only)
1 per
1.0 ft2 SBS-TA, APP-TA
(Optional)
SBS-TA, APP-
TA
SBS-TA,
APP-TA -105.0
SC-102
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 (#14
only)
1 per
1.0 ft2 APP-TA (Optional)
APP-TA APP-TA -105.0
SC-103
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
Optional BP-AA or SBS-AA
vapor barrier over
concrete deck.
One or more layers, any
combination, loose laid
Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 (#14
only)
1 per
1.0 ft2 SBS-TA (Optional)
SBS-TA SBS-TA -120.0
SC-104
Min. 22 ga., type B, Grade
80 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid Min. 0.5-inch DensDeck Prime Note 2 1 per
1.0 ft2 SBS-TA (Optional)
SBS-TA SBS-TA -127.5
SELF-ADHERING BASE PLY:
SC-105
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board Note 2 1 per
3.2 ft2 SBS-SA
(Optional)
SBS-SA, SBS-
TA, APP-TA
SBS-SA,
SBS-TA,
APP-TA
-30.0*
SC-106
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 2.0-inch EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN or EnergyGuard Ultra Note 2 1 per
4.0 ft2 SBS-SA
(Optional)
SBS-SA, SBS-
TA, APP-TA
SBS-SA,
SBS-TA,
APP-TA
-37.5*
SC-107
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 2-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra, EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN
Note 2 1 per
4.0 ft2 SBS-SA
(Optional)
SBS-TA, APP-
TA
SBS-TA,
APP-TA -37.5*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 34 of 91
TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer
(Note 13)
Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasteners
(Note 11) Attach Base Ply Ply Cap Ply
SC-108
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.375-inch SECUROCK Gypsum-Fiber Roof
Board Note 2 1 per
2.7 ft2 SBS-SA
(Optional)
SBS-SA, SBS-
TA, APP-TA
SBS-SA,
SBS-TA,
APP-TA
-45.0*
SC-109
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board Note 2 1 per
2.0 ft2 SBS-SA
(Optional)
SBS-TA or
APP-TA
SBS-TA or
APP-TA -45.0*
SC-110
Min. 22 ga., Type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
Note 2 1 per
2.0 ft2 SBS-SA
(Optional)
SBS-TA, APP-
TA
SBS-TA,
APP-TA -45.0*
SC-111
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN or EnergyGuard Ultra Note 2 1 per
2.0 ft2 SBS-SA (Optional)
SBS-SA SBS-SA -45.0*
SC-112
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra, EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN
Note 2 1 per
2.0 ft2 SBS-SA
(Optional)
SBS-TA, APP-
TA
SBS-TA,
APP-TA -45.0*
SC-113
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 2.0-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra, EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN
Note 2 1 per
3.2 ft2 SBS-SA
(Optional)
SBS-TA, APP-
TA
SBS-TA,
APP-TA -45.0*
SC-114
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 2.0-inch EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN or EnergyGuard Ultra Note 2 1 per
2.0 ft2 SBS-SA (Optional)
SBS-SA SBS-SA -45.0*
SC-115
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board Note 2 1 per
1.6 ft2 SBS-SA
(Optional)
SBS-TA or
APP-TA
SBS-TA or
APP-TA -52.5
SC-116
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per
1.8 ft2 SBS-SA
(Optional)
SBS-TA or
APP-TA
SBS-TA or
APP-TA -52.5
SC-117
Min. 22 ga., type B, Grade
50 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch EnergyGuard Polyiso Insulation Note 2 1 per
1.8 ft2 SBS-SA (Optional)
SBS-TA SBS-TA -60.0
SC-118
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN or EnergyGuard Ultra Note 2 1 per
1.3 ft2 SBS-SA
(Optional)
SBS-TA, APP-
TA
SBS-TA,
APP-TA -60.0
SC-119
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 2.0-inch EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN or EnergyGuard Ultra Note 2 1 per
1.5 ft2 SBS-SA
(Optional)
SBS-TA, APP-
TA
SBS-TA,
APP-TA -60.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 35 of 91
TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer
(Note 13)
Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasteners
(Note 11) Attach Base Ply Ply Cap Ply
SC-120
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 2-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra Note 2 1 per
1.8 ft2 SBS-SA
(Optional)
SBS-TA, APP-
TA
SBS-TA,
APP-TA -60.0
SC-121
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board Note 2 1 per
1.3 ft2 SBS-SA
(Optional)
SBS-TA or
APP-TA
SBS-TA or
APP-TA -60.0
SC-122
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 (#14
only)
1 per
1.8 ft2 SBS-SA
(Optional)
SBS-TA or
APP-TA
SBS-TA or
APP-TA -60.0
SC-123
Min. 22 ga., Type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra Note 2 1 per
1.3 ft2 SBS-SA
(Optional)
SBS-TA, APP-
TA
SBS-TA,
APP-TA -67.5
SC-124
Min. 22 ga., Type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.375-inch SECUROCK Gypsum-Fiber Roof
Board Note 2 1 per
1.3 ft2 SBS-SA
(Optional)
SBS-TA, APP-
TA
SBS-TA,
APP-TA -67.5
VENTING SYSTEMS:
SC-125
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 2-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra Note 2 1 per
4.0 ft2
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional)
One or more
BP-AA, SBS-AA
SBS-AA -37.5*
SC-126
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch EnergyGuard Polyiso Insulation Note 2 1 per
2.0 ft2
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional)
One or more
BP-AA, SBS-AA
SBS-AA -45.0*
SC-127
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN Note 2 1 per
2.0 ft2
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional)
One or more
BP-AA, SBS-AA
SBS-AA -45.0*
SC-128
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 2.0-inch EnergyGuard RH Note 2 1 per
2.9 ft2
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional)
One or more
BP-AA, SBS-AA
SBS-AA -45.0*
SC-129
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch EnergyGuard Ultra Note 2 1 per
3.2 ft2
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional)
One or more
BP-AA, SBS-AA
SBS-AA -45.0*
SC-130
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 2.5-inch EnergyGuard RA Note 2 1 per
4.0 ft2
GAFGLAS Stratavent
Perforated Venting
Base Sheet
BP-AA, SBS-AA SBS-AA -45.0*
SC-131
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 3-inch EnergyGuard RH, EnergyGuard RN Note 2 1 per
3.2 ft2
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional)
One or more
BP-AA, SBS-AA
SBS-AA -45.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 36 of 91
TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer
(Note 13)
Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasteners
(Note 11) Attach Base Ply Ply Cap Ply
SC-132
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 3-inch EnergyGuard Polyiso Insulation Note 2 1 per
3.2 ft2
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional)
One or more
BP-AA, SBS-AA
SBS-AA -45.0*
SC-133
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 3-inch EnergyGuard Polyiso Insulation Note 2 1 per
4.0 ft2
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more
BP-AA, SBS-AA SBS-AA -45.0*
SC-134
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch EnergyGuard Polyiso Insulation Note 2 1 per
2.0 ft2
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional)
One or more
BP-AA, SBS-AA
SBS-AA -52.5
SC-135
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 2-inch EnergyGuard RH Note 2 1 per
2.0 ft2
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional)
One or more
BP-AA, SBS-AA
SBS-AA -52.5
SC-136
Min. 22 ga., type B, Grade
50 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch EnergyGuard Polyiso Insulation Note 2 1 per
1.8 ft2
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional)
One or more
BP-AA, SBS-AA
SBS-AA -60.0
SC-137
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 2.0-inch EnergyGuard Ultra Note 2 1 per
2.0 ft2
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional)
One or more
BP-AA, SBS-AA
SBS-AA -60.0
SC-138
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 2-inch EnergyGuard Polyiso Insulation Note 2 1 per
2.0 ft2
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional)
One or more
BP-AA, SBS-AA
SBS-AA -60.0
SC-139
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 2-inch EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN Note 2 1 per
1.5 ft2
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional)
One or more
BP-AA, SBS-AA
SBS-AA -67.5
SC-140
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 3-inch EnergyGuard RH, EnergyGuard RN Note 2 1 per
1.6 ft2
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional)
One or more
BP-AA, SBS-AA
SBS-AA -67.5
SC-141
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 2-inch EnergyGuard Polyiso Insulation Note 2 1 per
1.5 ft2
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional)
One or more
BP-AA, SBS-AA
SBS-AA -75.0
SC-142
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 2.0-inch EnergyGuard Ultra Note 2 1 per
1.5 ft2
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional)
One or more
BP-AA, SBS-AA
SBS-AA -75.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 37 of 91
TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer
(Note 13)
Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasteners
(Note 11) Attach Base Ply Ply Cap Ply
SC-143
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 2-inch EnergyGuard Polyiso Insulation or
EnergyGuard RH Note 2 1 per
1.5 ft2
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional)
One or more
BP-AA, SBS-AA
SBS-AA
(ASTM
D6164,
polyester
only)
-82.5
SC-144
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 3-inch EnergyGuard Polyiso Insulation Note 2 1 per
1.6 ft2
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional)
One or more
BP-AA, SBS-AA
SBS-AA -82.5
SC-145
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid Min. 0.25-inch DensDeck Note 2 1 per
1.0 ft2
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional)
One or more
BP-AA, SBS-AA
SBS-AA -82.5
SC-146
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board Note 2 1 per
1.0 ft2
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional)
One or more
BP-AA, SBS-AA
SBS-AA -97.5
COLD-APPLIED SYSTEMS:
SC-147
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.5-inch Structodek High Density Fiberboard
Roof Insulation Note 2 1 per
2.0 ft2 BP-CA None SBS-CA -45.0*
SC-148
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board Note 2 1 per
4.0 ft2 SBS-CA None SBS-CA -45.0*
SC-149
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch EnergyGuard RH, EnergyGuard RN,
EnergyGuard Polyiso Insulation Note 2 1 per
2.0 ft2 SBS-CA1 None SBS-CA1 -45.0*
SC-150
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 2-inch EnergyGuard RH, EnergyGuard RN,
EnergyGuard Polyiso Insulation Note 2 1 per
2.9 ft2 SBS-CA1 None SBS-CA1 -45.0*
SC-151
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board Note 2 1 per
2.0 ft2 SBS-CA1 None SBS-CA1 -45.0*
SC-152
Min. 22 ga., Type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, min. 1.5-inch
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
Note 2 1 per
2.0 ft2 SBS-CA or SBS-CA1 None SBS-CA or
SBS-CA1 -45.0*
SC-153
Min. 22 ga., Type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
Note 2
(AccuTrac
Flat Plates
only)
1 per
1.3 ft2 SBS-CA1 None SBS-CA1 -52.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 38 of 91
TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer
(Note 13)
Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasteners
(Note 11) Attach Base Ply Ply Cap Ply
SC-154
Min. 22 ga., type B, Grade
50 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch EnergyGuard Polyiso Insulation Note 2 1 per
1.8 ft2 SBS-CA1 None SBS-CA1 -60.0
SC-155
Min. 22 ga., Type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 1.5-inch EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN, EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
Note 2 1 per
1.3 ft2 SBS-CA1 None SBS-CA1 -67.5
SC-156
Min. 22 ga., Type B, Grade
33 steel or min. 2,500 psi
structural concrete
(Optional) One or more
layers, any combination,
loose laid
Min. 2-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra Note 2 1 per
1.8 ft2 SBS-CA1 None SBS-CA1 -67.5
SC-157
Min. 22 ga., Type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.375-inch SECUROCK Gypsum-Fiber Roof
Board Note 2 1 per
1.3 ft2 SBS-CA1 None SBS-CA1 -67.5
HYBRID HOT/COLD-APPLIED SYSTEMS:
SC-158
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board Note 2 1 per
4.0 ft2 BP-AA or SBS-AA (Optional) BP-
AA or SBS-AA SBS-CA1 -45.0*
SC-159
Min. 22 ga., Type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
Note 2
(AccuTrac
Flat Plates)
1 per
1.3 ft2 BP-AA or SBS-AA (Optional) BP-
AA or SBS-AA SBS-CA1 -52.5
SC-160
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.5-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board Note 2 1 per
2.0 ft2 BP-AA or SBS-AA (Optional) BP-
AA or SBS-AA SBS-CA1 -60.0
SC-161
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structural concrete
One or more layers, any
combination, loose laid
Min. 0.5-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board Note 2 1 per
1.6 ft2 BP-AA or SBS-AA (Optional) BP-
AA or SBS-AA SBS-CA1 -82.5
SC-162
Min. 20 ga., type B, Grade
33 steel, min. 22 ga., type
B, Grade 80 steel or min.
2,500 psi structural
concrete
One or more layers, any
combination, loose laid
Min. 0.5-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board Note 2 1 per
1.6 ft2 BP-AA or SBS-AA (Optional) BP-
AA or SBS-AA SBS-CA1 -90.0
SC-163
Min. 20 ga., type B, Grade
33 steel, min. 22 ga., type
B, Grade 80 steel or min.
2,500 psi structural
concrete
One or more layers, any
combination, loose laid
Min. 0.5-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board Note 2 1 per
1.5 ft2 BP-AA or SBS-AA (Optional) BP-
AA or SBS-AA SBS-CA1 -97.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 39 of 91
TABLE 2D: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1A: THERMAL BARRIER WITH VAPOR BARRIER, MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1) Base Insulation Layer
Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Fasten
(Note 11) Attach Base Ply Ply Cap Ply
SELF-ADHERING BASE PLY:
SC-164
Min. 22 ga., Type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 0.625-inch DensDeck Prime or min. 0.5-inch
SECUROCK Gypsum-Fiber Roof Board, loose-laid,
covered with GAF SA Vapor Retarder, self-adhered
Min. 1.5-inch EnergyGuard RH, loose laid,
followed by min. 0.5-inch EnergyGuard RH HD
Polyiso Insulation, EnergyGuard HD Polyiso
Insulation, EnergyGuard HD Plus Polyiso Insulation
Note 2 1 per
2.0 ft2 SBS-SA
(Optional)
SBS-TA,
APP-TA
SBS-TA,
APP-TA -45.0*
COLD-APPLIED BASE PLY:
SC-165
Min. 22 ga., Type B,
Grade 33 steel or
min. 2,500 psi
structural concrete
Min. 0.625-inch DensDeck Prime or min. 0.5-inch
SECUROCK Gypsum-Fiber Roof Board, loose-laid,
covered with GAF SA Vapor Retarder, self-adhered
Min. 1.5-inch EnergyGuard RH, loose laid,
followed by min. 0.5-inch EnergyGuard RH HD
Polyiso Insulation, EnergyGuard HD Polyiso
Insulation, EnergyGuard HD Plus Polyiso Insulation
Note 2 1 per
2.0 ft2
SBS-CA or
SBS-CA1 None
SBS-CA
or SBS-
CA1
-45.0*
TABLE 2E: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-3: BONDED AND MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Adhesive & Fasteners (Notes 6,7,8,11) Attach Base Ply Ply Cap Ply
CONVENTIONAL SYSTEMS:
SC-166
Min. 22 ga., type B,
Grade 33 steel or min.
2,500 psi structural
concrete
Min. 2.0-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard
RN or EnergyGuard Ultra,
loose-laid
Min. 0.25-inch
DensDeck Prime
Adhesive: OB500
Fasteners: Drill-Tec XHD (steel only) or Drill-
Tec #14 HD (concrete only) & Drill-Tec Plates
Adhesive: 12-inch o.c.
Fasteners: 1 per 1.3 ft2
SBS-TA or
APP-TA
(Optional)
SBS-TA or
APP-TA
SBS-TA
or APP-
TA
-97.5
SELF-ADHERING BASE PLY:
SC-167
Min. 22 ga., type B,
Grade 33 steel or min.
2,500 psi structural
concrete
Min. 2.0-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard
RN or EnergyGuard Ultra,
loose-laid
Min. 0.25-inch
DensDeck Prime
Adhesive: OB500
Fasteners: Drill-Tec XHD (steel only) or Drill-
Tec #14 HD (concrete only) & Drill-Tec Plates
Adhesive: 12-inch o.c.
Fasteners: 1 per 1.3 ft2 SBS-SA
(Optional)
SBS-TA or
APP-TA
SBS-TA
or APP-
TA
-97.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 40 of 91
TABLE 2F: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Insulation Layer(s)
(Note 13)
Base Sheet Roof Cover (Note 15) MDP
(psf) Type Fasteners (Note 11) Attach Base Ply Cap Ply
CONVENTIONAL SYSTEMS:
SC-168
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more layers,
any combination
GAFGLAS #75 Base Sheet, Tri-Ply #75
Base Sheet, GAFGLAS #80 Ultima
Base Sheet or GAFGLAS Stratavent
Nailable Venting Base Sheet
Note 2
24-inch o.c. at min. 2-inch laps and
24-inch o.c. in two, equally spaced,
staggered center rows
BP-AA, SBS-
AA SBS-AA -30.0*
SC-169
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more layers,
any combination
GAFGLAS #75 Base Sheet, Tri-Ply #75
Base Sheet, GAFGLAS #80 Ultima
Base Sheet or GAFGLAS Stratavent
Nailable Venting Base Sheet
Note 2
18-inch o.c. at min. 2-inch laps and
18-inch o.c. in two, equally spaced,
staggered center rows
BP-AA, SBS-
AA SBS-AA -37.5*
SC-170
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more layers,
any combination
GAFGLAS #75 Base Sheet, Tri-Ply #75
Base Sheet, GAFGLAS #80 Ultima
Base Sheet or GAFGLAS Stratavent
Nailable Venting Base Sheet
Note 2
18-inch o.c. at min. 2-inch laps and
18-inch o.c. in three, equally
spaced, staggered center rows
BP-AA, SBS-
AA SBS-AA -45.0*
SC-171
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more layers,
any combination
GAFGLAS #75 Base Sheet, Tri-Ply #75
Base Sheet, GAFGLAS #80 Ultima
Base Sheet or GAFGLAS Stratavent
Nailable Venting Base Sheet
Note 2
12-inch o.c. at min. 2-inch laps and
18-inch o.c. in three, equally
spaced, staggered center rows
SBS-TA, APP-
TA
SBS-TA,
APP-TA -45.0*
SC-172
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more layers,
any combination
GAFGLAS #75 Base Sheet, Tri-Ply #75
Base Sheet, GAFGLAS #80 Ultima
Base Sheet or GAFGLAS Stratavent
Nailable Venting Base Sheet
Note 2
12-inch o.c. at min. 3.5-inch laps
and 12-inch o.c. in three, equally
spaced, staggered center rows
SBS-AA SBS-AA,
SBS-TA -45.0*
SC-173
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Optional BP-AA or
SBS-AA vapor
barrier over
concrete deck.
One or more layers,
any combination
insulation.
Ruberoid Mop Smooth, Ruberoid
Mop Smooth 1.5, Ruberiod Mop
Plus Smooth
Note 2 18-inch o.c. at min. 3.5-inch laps (Optional)
SBS-TA SBS-TA -45.0*
SC-174
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more layers,
any combination Ruberoid Mop Smooth 1.5 Note 2 18-inch o.c. at min. 3.5-inch laps BP-AA, SBS-
AA SBS-AA -45.0*
SC-175
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more layers,
any combination Ruberoid Mop Smooth 1.5 Drill-Tec 2 in. Barbed Plates with
Drill-Tec #12 (steel only) or #14
Off-centered in the lap by 0.5-inch
towards the sheet-edge and
spaced 18-inch o.c. within the min.
4-inch wide, heat-welded laps
(Optional)
SBS-TA SBS-TA -45.0*
SC-176
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more layers,
any combination Ruberoid Mop Smooth 1.5 Drill-Tec Batten Bar with Drill-
Tec #12 (steel only) or #14
18-inch o.c. within min. 4-inch
wide, heat-welded laps
(Optional)
SBS-TA SBS-TA -45.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 41 of 91
TABLE 2F: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Insulation Layer(s)
(Note 13)
Base Sheet Roof Cover (Note 15) MDP
(psf) Type Fasteners (Note 11) Attach Base Ply Cap Ply
SC-177
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more layers,
any combination Ruberoid HW Smooth Drill-Tec 2 in. Barbed Plates with
Drill-Tec #12 (steel only) or #14
12-inch o.c. within min. 4-inch
wide, heat-welded laps
(Optional)
SBS-TA SBS-TA -45.0*
SC-178
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Optional BP-AA or
SBS-AA vapor
barrier over
concrete deck.
One or more layers,
any combination
insulation
Ruberoid Mop Smooth, Ruberoid
Mop Smooth 1.5, Ruberiod Mop
Plus Smooth
Note 2 12-inch o.c. at min. 3.5-inch laps (Optional)
SBS-TA SBS-TA -52.5
SC-179
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more layers,
any combination Ruberoid Mop Smooth 1.5 Drill-Tec 2 in. Barbed Plates with
Drill-Tec #12 (steel only) or #14
Off-centered in the lap by 0.5-inch
towards the sheet-edge and
spaced 12-inch o.c. within the min.
4-inch wide, heat-welded laps
(Optional)
SBS-TA SBS-TA -52.5
SC-180 Min. 22 ga., type B, Grade
33 steel
One or more layers,
any combination Ruberoid Mop Smooth 1.5
Drill-Tec 2-3/8 in. Barbed XHD
Plates or Drill-Tec Eyehook
AccuSeam Plates with Drill-Tec
XHD
Off-centered in the lap by 0.25-
inch towards the sheet-edge and
spaced 12-inch o.c. within the min.
5-inch wide, heat-welded laps
(Optional)
SBS-TA SBS-TA -67.5
SC-181 Min. 22 ga., type B, Grade
33 steel
One or more layers,
any combination Ruberoid Mop Smooth 1.5 Drill-Tec Batten Bar with Drill-
Tec XHD
12-inch o.c. within min. 4-inch
wide, heat-welded laps
(Optional)
SBS-TA SBS-TA -67.5
SC-182
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more layers,
any combination
GAFGLAS #80 Ultima Base Sheet or
GAFGLAS Stratavent Nailable
Venting Base Sheet
Note 2
6-inch o.c. at min. 3.5-inch laps and
12-inch o.c. in three, equally
spaced, staggered center rows
SBS-AA SBS-AA,
SBS-TA -82.5
SC-183
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more layers,
any combination GAFGLAS #80 Ultima Base Sheet Note 2
6-inch o.c. at min. 3.5-inch laps and
12-inch o.c. in three, equally
spaced, staggered center rows
SBS-TA, APP-
TA
SBS-TA,
APP-TA -82.5
SC-184
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more layers,
any combination GAFGLAS #75
Note 2 (Drill-Tec 3” Standard Steel
Plate; Drill-Tec ASAP 3S (steel) or
Drill-Tec Heavy Duty ASAP Roofing
Fastener Assembled with a 3” Metal
Plate only)
6-inch o.c. at min. 3.5-inch laps and
12-inch o.c. in three, equally
spaced, staggered center rows
SBS-TA, APP-
TA
SBS-TA,
APP-TA -82.5
SC-185
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more layers,
any combination Ruberoid Mop Smooth 1.5 Note 2
18-inch o.c. at min. 3.25-inch laps
and 18-inch o.c. in two, equally
spaced, staggered center rows
BP-AA, SBS-
AA SBS-AA -105.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 42 of 91
TABLE 2F: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Insulation Layer(s)
(Note 13)
Base Sheet Roof Cover (Note 15) MDP
(psf) Type Fasteners (Note 11) Attach Base Ply Cap Ply
SC-186
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
Optional BP-AA or
SBS-AA vapor
barrier over
concrete deck.
One or more layers,
any combination
insulation
Ruberoid Mop Smooth, Ruberoid
Mop Smooth 1.5, Ruberiod Mop
Plus Smooth
Note 2 6-inch o.c. at min. 3.5-inch laps (Optional)
SBS-TA SBS-TA -112.5
SC-187
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more layers,
any combination GAFGLAS #80 Ultima Base Sheet Note 2
6-inch o.c. at min. 3.5-inch laps and
6-inch o.c. in three, equally spaced,
staggered center rows
(Optional)
SBS-TA SBS-TA -150.0
SC-188
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more layers,
any combination Ruberoid Mop Smooth 1.5
Drill-Tec #14 Fasteners with
Drill-Tec 2 3/8 in. Barbed XHD
Plates or Drill-Tec Eyehook
AccuSeam Plates
6-inch o.c. at min. 3.25-inch laps
and 6-inch o.c. in three, equally
spaced, staggered center rows
SBS-TA SBS-TA -150.0
SC-189
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more layers,
any combination GAFGLAS #75
Note 2 (Drill-Tec 3” Standard Steel
Plate; Drill-Tec ASAP 3S (steel) or
Drill-Tec Heavy Duty ASAP Roofing
Fastener Assembled with a 3” Metal
Plate only)
6-inch o.c. at min. 3.5-inch laps and
6-inch o.c. in three, equally spaced,
staggered center rows
(Optional)
Ruberoid
HW Smooth
SBS-TA -150.0
SELF-ADHERING BASE PLY:
SC-190
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more layers,
any combination
Liberty SBS Mechanically Attached
Base Sheet Note 2
12-inch o.c. at min. 3.5-inch laps
and 18-inch o.c. in two, equally
spaced, staggered center rows
(Optional)
SBS-SA, SBS-
SA-T, SBS-TA
or APP-TA
SBS-SA,
SBS-TA or
APP-TA
-30.0*
SC-191
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more layers,
any combination
Liberty SBS Mechanically Attached
Base Sheet Note 2
9-inch o.c. at min. 4-inch laps and
9-inch o.c. in two, equally spaced,
staggered center rows
(Optional)
SBS-SA SBS-SA -37.5
SC-192
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more layers,
any combination
Liberty SBS Self-Adhering Base/Ply
Sheet Note 2 12-inch o.c. at min. 3.5-inch laps
and 18-inch o.c. in one center row
(Optional)
SBS-SA SBS-SA -45.0*
COLD-APPLIED SYSTEMS:
SC-193
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more layers,
any combination Ruberoid Mop Smooth 1.5 Note 2 18-inch o.c. at min. 3-inch laps None SBS-CA or
SBS-CA1 -30.0*
SC-194
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more layers,
any combination Ruberoid 20 Smooth Note 2
12-inch o.c. at min. 3-inch laps and
12-inch o.c. in two, equally spaced,
staggered center rows
None SBS-CA or
SBS-CA1 -45.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 43 of 91
TABLE 2F: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Insulation Layer(s)
(Note 13)
Base Sheet Roof Cover (Note 15) MDP
(psf) Type Fasteners (Note 11) Attach Base Ply Cap Ply
SC-195
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more layers,
any combination
GAFGLAS #75 Base Sheet, Tri-Ply #75
Base Sheet Note 2
12-inch o.c. at min. 2-inch laps and
12-inch o.c. in three, equally
spaced, staggered center rows
None SBS-CA -45.0*
SC-196
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more layers,
any combination Ruberoid Mop Smooth 1.5 Note 2
24-inch o.c. at min. 3-inch laps and
24-inch o.c. in two, equally spaced,
staggered center rows
None SBS-CA or
SBS-CA1 -45.0
SC-197
Min. 22 ga., type B, Grade
33 steel or min. 2,500 psi
structrual concrete
One or more layers,
any combination
GAFGLAS #80 Ultima Base Sheet or
GAFGLAS Stratavent Nailable
Venting Base Sheet
Note 2
6-inch o.c. at min. 3.5-inch laps and
12-inch o.c. in three, equally
spaced, staggered center rows
SBS-CA at
2.0 gal/sq.
SBS-CA at
2.0 gal/sq. -82.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 44 of 91
TABLE 3A: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY)
SEE NOTE 16 FOR VAPOR BARRIER OPTIONS
System
No.
Deck
(Note 1)
Base Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
CONVENTIONAL SYSTEMS WITH BASE INSULATION LAYER ONLY
C-1. Primed structural
concrete Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS-AA
(Optional) One or more BP-
AA, SBS-AA, SBS-TA or APP-
TA
SBS-AA, SBS-TA or
APP-TA -140.0
C-2. Primed structural
concrete Min. 0.5-inch EnergyGuard Perlite Recover Board Hot asphalt BP-AA, SBS-AA
(Optional) One or more BP-
AA, SBS-AA, SBS-TA or APP-
TA
SBS-AA, SBS-TA or
APP-TA -165.0
C-3. Primed structural
concrete Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA, SBS-AA
(Optional) One or more BP-
AA, SBS-AA, SBS-TA or APP-
TA
SBS-AA, SBS-TA or
APP-TA -165.0
C-4. Primed structural
concrete Min. 1.5-inch EnergyGuard Composite Hot asphalt BP-AA, SBS-AA (Optional) One or more BP-
AA, SBS-AA
SBS-AA, SBS-TA or
APP-TA -270.0
C-5. Structural
concrete Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA
(Optional) One or more BP-
AA, SBS-AA, SBS-TA or APP-
TA
SBS-AA, SBS-TA or
APP-TA -165.0
C-6. Structural
concrete Min. 0.25-inch DensDeck Prime OB500 SBS-TA (Optional) One or more SBS-
TA SBS-TA -300.0
C-7. Structural
concrete Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA
(Optional) One or more BP-
AA, SBS-AA, SBS-TA or APP-
TA
SBS-AA, SBS-TA or
APP-TA -165.0
C-8. Structural
concrete Min. 0.25-inch DensDeck Prime GAF 2-Part SBS-TA (Optional) One or more SBS-
TA SBS-TA -245.0
SELF-ADHERING BASE PLY WITH BASE INSULATION LAYER ONLY
C-9. Primed structural
concrete Min. 1.5-inch EnergyGuard Ultra Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA
SBS-SA, SBS-TA, APP-
TA -90.0
C-10. Primed structural
concrete Min. 1.5-inch EnergyGuard RN Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA SBS-TA, APP-TA -210.0
C-11. Primed structural
concrete Min. 1.5-inch EnergyGuard RA Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA SBS-TA, APP-TA -217.5
C-12. Structural
concrete Min 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500, 6-
inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -110.0
C-13. Structural
concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 SBS-SA (Optional) SBS-SA SBS-SA -120.0
C-14. Structural
concrete Min. 0.25-inch DensDeck OB500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -122.5
C-15. Structural
concrete Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -137.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 45 of 91
TABLE 3A: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY)
SEE NOTE 16 FOR VAPOR BARRIER OPTIONS
System
No.
Deck
(Note 1)
Base Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
C-16. Structural
concrete Min. 1-inch EnergyGuard RN OB 500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -162.5
C-17. Structural
concrete
Min. 0.25-inch DensDeck primed with Matrix 307 Premium Asphalt
Primer or ASTM D41 primer OB500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -167.5
C-18. Structural
concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -232.5
C-19. Structural
concrete
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with
Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -285.0
C-20. Structural
concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -232.5
C-21. Structural
concrete Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -137.5
C-22. Structural
concrete
Min. 0.25-inch DensDeck primed with Matrix 307 Premium Asphalt
Primer or ASTM D41 primer GAF 2-Part SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -167.5
C-23. Structural
concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -180.0
C-24. Structural
concrete
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with
Matrix 307 Premium Asphalt Primer or ASTM D41 primer GAF 2-Part SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -180.0
C-25. Structural
concrete Min. 1.5-inch EnergyGuard RN GAF 2-Part SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA SBS-TA, APP-TA -210.0
C-26. Structural
concrete Min. 1.5-inch EnergyGuard RA GAF 2-Part SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA SBS-TA, APP-TA -217.5
VENTING SYSTEMS WITH BASE INSULATION LAYER ONLY
C-27. Primed structural
concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt GAFGLAS Stratavent
Perforated Venting Base Sheet
(Optional) One or more BP-
AA, SBS-AA SBS-AA -150.0
C-28. Primed structural
concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt GAFGLAS Stratavent
Perforated Venting Base Sheet One or more BP-AA, SBS-AA SBS-TA or APP-TA -150.0
C-29. Primed structural
concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Hot asphalt GAFGLAS Stratavent
Perforated Venting Base Sheet (Optional) BP-AA, SBS-AA SBS-AA -150.0
C-30. Primed structural
concrete Min. 0.5-inch EnergyGuard RN Hot asphalt GAFGLAS Stratavent
Perforated Venting Base Sheet SBS-AA SBS-AA -172.5
C-31. Primed structural
concrete Min. 1.5-inch EnergyGuard Ultra Hot asphalt GAFGLAS Stratavent
Perforated Venting Base Sheet
(Optional) One or more BP-
AA, SBS-AA SBS-AA -172.5
C-32. Primed structural
concrete Min. 1.5-inch EnergyGuard Ultra Hot asphalt GAFGLAS Stratavent
Perforated Venting Base Sheet One or more BP-AA, SBS-AA SBS-TA or APP-TA -172.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 46 of 91
TABLE 3A: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY)
SEE NOTE 16 FOR VAPOR BARRIER OPTIONS
System
No.
Deck
(Note 1)
Base Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
C-33. Primed structural
concrete Min. 1-inch EnergyGuard RN Hot asphalt GAFGLAS Stratavent
Perforated Venting Base Sheet One or more BP-AA, SBS-AA SBS-AA -292.5
COLD-APPLIED SYSTEMS WITH BASE INSULATION LAYER ONLY
C-34. Structural
concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard RN OB500 SBS-CA1 None SBS-CA1 -60.0
TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS)
SEE NOTE 16 FOR VAPOR BARRIER OPTIONS
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
CONVENTIONAL SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER:
C-35. Primed structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN Hot asphalt
Min. 0.25-inch DensDeck, DensDeck
Prime or SECUROCK Gypsum-Fiber Roof
Board
Hot asphalt BP-AA (Optional) BP-AA SBS-AA or
SBS-TA -112.5
C-36. Primed structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
Hot asphalt Min. 0.25-inch DensDeck Prime Hot asphalt APP-TA (Optional) APP-TA APP-TA -127.5
C-37. Primed structural
concrete
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra Hot asphalt
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation, EnergyGuard
Perlite Recover Board, min. 0.75-inch
EnergyGuard Perlite Roof Insulation,
min. 0.25-inch DensDeck, DensDeck
Prime, SECUROCK Gypsum Fiber Roof
Board
Hot asphalt BP-AA, SBS-AA (Optional) BP-AA,
SBS-AA SBS-AA -150.0
C-38. Primed structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof
Insulation (homogeneous) Hot asphalt BP-AA, SBS-AA
(Optional) One or
more BP-AA, SBS-
AA, SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -172.5
C-39. Primed structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.5-inch EnergyGuard Perlite
Recover Board Hot asphalt BP-AA, SBS-AA
(Optional) One or
more BP-AA, SBS-
AA, SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -187.5
C-40. Primed structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
Hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board Hot asphalt BP-AA or SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -225.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 47 of 91
TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS)
SEE NOTE 16 FOR VAPOR BARRIER OPTIONS
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
C-41. Primed structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
Hot asphalt Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-TA (Optional) SBS-TA SBS-TA -232.5
C-42. Primed structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board Hot asphalt APP-TA (Optional) APP-TA APP-TA -240.0
C-43. Primed structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck or DensDeck
Prime Hot asphalt BP-AA, SBS-AA
(Optional) One or
more BP-AA, SBS-
AA, SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -240.0
C-44. Primed structural
concrete
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
Hot asphalt
Min. 0.75-inch EnergyGuard Perlite Roof
Insulation (homogeneous), min. 0.5-inch
Structodek High Density Fiberboard Roof
Insulation or EnergyGuard Perlite
Recover Board, min. 0.25-inch DensDeck
Prime or SECUROCK Gypsum-Fiber Roof
Board
Hot asphalt BP-AA or SBS-AA
(Optional) One or
more BP-AA, SBS-
AA, SBS-TA
SBS-AA, SBS-
TA -255.0
C-45. Primed structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 1.5-inch EnergyGuard Composite Hot asphalt BP-AA, SBS-AA
(Optional) One or
more BP-AA, SBS-
AA
SBS-AA, SBS-
TA or APP-TA -270.0
C-46. Primed structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation Hot asphalt BP-AA, SBS-AA
(Optional) One or
more BP-AA, SBS-
AA, SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -307.5
C-47. Structural
concrete
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500 Min. 0.25-inch DensDeck or DensDeck
Prime OB500 BP-AA, SBS-AA,
SBS-TA or APP-TA
(Optional) One or
more BP-AA, SBS-
AA, SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -150.0
C-48. Structural
concrete
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500 Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation OB500 BP-AA, SBS-AA
(Optional) One or
more BP-AA, SBS-
AA, SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -165.0
C-49. Structural
concrete
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board OB500 BP-AA or SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -187.5
C-50. Structural
concrete
Min. 1-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH OB500
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board, primed with Matrix 307
Premium Asphalt Primer
OB500 SBS-TA (Optional) SBS-TA SBS-TA -210.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 48 of 91
TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS)
SEE NOTE 16 FOR VAPOR BARRIER OPTIONS
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
C-51. Structural
concrete
Min. 2.0-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board OB500 BP-AA or SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -225.0
C-52. Structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500 Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA, APP-TA (Optional) SBS-TA,
APP-TA
SBS-TA, APP-
TA -240.0
C-53. Structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-TA (Optional) SBS-TA SBS-TA -300.0
C-54. Structural
concrete
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
GAF 2-Part Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA
(Optional) One or
more BP-AA, SBS-
AA, SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -180.0
C-55. Structural
concrete
Min. 0.5-inch EnergyGuard Polyiso
Insulation GAF 2-Part Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA,
SBS-TA or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -180.0
C-56. Structural
concrete
Min. 2.0-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2-Part Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board GAF 2-Part BP-AA or SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -225.0
C-57. Structural
concrete
Min. 2.0-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2-Part Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board GAF 2-Part SBS-TA or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -232.5
C-58. Structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.25-inch DensDeck or DensDeck
Prime GAF 2-Part BP-AA, SBS-AA,
SBS-TA or APP-TA
(Optional) One or
more BP-AA, SBS-
AA, SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -240.0
SELF-ADHERING BASE PLY WITH POLYISOCYANURATE BASE INSULATION LAYER
C-59. Structural
concrete Min. 1.5-inch EnergyGuard RH OB500
Min. 0.5-inch EnergyGuard RH HD
Polyiso Insulation, EnergyGuard HD
Polyiso Insulation, EnergyGuard HD Plus
Polyiso Insulation
OB500 SBS-SA (Optional) SBS-TA
or APP-TA
SBS-TA or
APP-TA -97.5
C-60. Structural
concrete Min. 1-inch EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board OB500 SBS-SA (Optional) SBS-TA,
APP-TA
SBS-TA, APP-
TA -120.0
C-61. Structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck OB500 SBS-SA (Optional) SBS-TA,
APP-TA
SBS-TA, APP-
TA -122.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 49 of 91
TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS)
SEE NOTE 16 FOR VAPOR BARRIER OPTIONS
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
C-62. Structural
concrete
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-SA (Optional) SBS-SA SBS-SA -152.5
C-63. Structural
concrete
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch DensDeck; surface shall
be primed with Matrix 307 Premium
Asphalt Primer or ASTM D41 primer
OB500 SBS-SA (Optional) SBS-TA,
APP-TA
SBS-TA, APP-
TA -167.5
C-64. Structural
concrete
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra OB500
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board (optional Matrix 307
Premium Asphalt Primer)
OB500 SBS-SA (Optional) SBS-TA,
APP-TA
SBS-TA, APP-
TA -232.5
C-65. Structural
concrete
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra OB500 (Optional) Additional layer(s) base
insulation OB500 SBS-SA (Optional) SBS-TA,
APP-TA
SBS-TA, APP-
TA -232.5
C-66. Structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board OB500 SBS-SA (Optional) SBS-TA,
APP-TA
SBS-TA, APP-
TA -270.0
C-67. Structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN OB500
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board; surface shall be primed with
Matrix 307 Premium Asphalt Primer or
ASTM D41 primer
OB500 SBS-SA (Optional) SBS-TA,
APP-TA
SBS-TA, APP-
TA -285.0
C-68. Structural
concrete Min. 1.5-inch EnergyGuard RH LRF-M
Min. 0.5-inch EnergyGuard RH HD
Polyiso Insulation, EnergyGuard HD
Polyiso Insulation, EnergyGuard HD Plus
Polyiso Insulation
LRF-M SBS-SA (Optional) SBS-TA
or APP-TA
SBS-TA or
APP-TA -97.5
C-69. Structural
concrete
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra LRF-M
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board (optional Matrix 307
Premium Asphalt Primer)
LRF-M SBS-SA (Optional) SBS-TA,
APP-TA
SBS-TA, APP-
TA -232.5
C-70. Structural
concrete
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra LRF-M (Optional) Additional layer(s) base
insulation LRF-M SBS-SA (Optional) SBS-TA,
APP-TA
SBS-TA, APP-
TA -232.5
C-71. Structural
concrete
Min. 0.5-inch EnergyGuard Polyiso
Insulation GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part SBS-SA (Optional) SBS-SA SBS-SA -152.5
C-72. Structural
concrete
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra GAF 2-Part (Optional) Additional layer(s) base
insulation GAF 2-Part SBS-SA (Optional) SBS-TA,
APP-TA
SBS-TA, APP-
TA -180.0
C-73. Structural
concrete
Min. 0.5-inch EnergyGuard Polyiso
Insulation GAF 2-Part
Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board (optional Matrix 307
Premium Asphalt Primer)
GAF 2-Part SBS-SA (Optional) SBS-TA,
APP-TA
SBS-TA, APP-
TA -180.0
VENTING SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER:
C-74. Primed structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof
Insulation (homogeneous) Hot asphalt
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One or
more BP-AA, SBS-
AA
SBS-AA -90.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 50 of 91
TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS)
SEE NOTE 16 FOR VAPOR BARRIER OPTIONS
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
C-75. Primed structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof
Insulation (homogeneous) Hot asphalt
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA or
APP-TA -90.0
C-76. Primed structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
Hot asphalt Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation Hot asphalt
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One or
more BP-AA, SBS-
AA
SBS-AA -90.0
C-77. Primed structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
Hot asphalt Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation Hot asphalt
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA or
APP-TA -90.0
C-78. Primed structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN Hot asphalt (Optional) EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN Hot asphalt
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One or
more BP-AA, SBS-
AA
SBS-AA -150.0
C-79. Primed structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN Hot asphalt (Optional) EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN Hot asphalt
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA or
APP-TA -150.0
C-80. Primed structural
concrete
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra Hot asphalt (Optional) EnergyGuard Polyiso
Insulation, EnergyGuard Ultra Hot asphalt
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) BP-AA,
SBS-AA SBS-AA -150.0
C-81. Primed structural
concrete Min. 1.5-inch EnergyGuard Ultra Hot asphalt (Optional) EnergyGuard Ultra Hot asphalt
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One or
more BP-AA, SBS-
AA
SBS-AA -172.5
C-82. Primed structural
concrete Min. 1.5-inch EnergyGuard Ultra Hot asphalt (Optional) EnergyGuard Ultra Hot asphalt
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA or
APP-TA -172.5
C-83. Primed structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
Hot asphalt Min. 0.25-inch DensDeck or DensDeck
Prime Hot asphalt
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One or
more BP-AA, SBS-
AA
SBS-AA -240.0
C-84. Primed structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
Hot asphalt Min. 0.25-inch DensDeck or DensDeck
Prime Hot asphalt
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA or
APP-TA -240.0
C-85. Structural
concrete
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500 Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation OB500
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One or
more BP-AA, SBS-
AA
SBS-AA -90.0
C-86. Structural
concrete
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500 Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation OB500
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA or
APP-TA -90.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 51 of 91
TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS)
SEE NOTE 16 FOR VAPOR BARRIER OPTIONS
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
C-87. Structural
concrete Min. 1.5-inch EnergyGuard Ultra OB500 (Optional) EnergyGuard Ultra OB500
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One or
more BP-AA, SBS-
AA
SBS-AA -150.0
C-88. Structural
concrete Min. 1.5-inch EnergyGuard Ultra OB500 (Optional) EnergyGuard Ultra OB500
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA or
APP-TA -150.0
C-89. Structural
concrete
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500 Min. 0.25-inch DensDeck or DensDeck
Prime OB500
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One or
more BP-AA, SBS-
AA
SBS-AA -150.0
C-90. Structural
concrete
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500 Min. 0.25-inch DensDeck or DensDeck
Prime OB500
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA or
APP-TA -150.0
C-91. Structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN OB500 (Optional) EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN OB500
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One or
more BP-AA, SBS-
AA
SBS-AA -150.0
C-92. Structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN OB500 (Optional) EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN OB500
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA or
APP-TA -150.0
C-93. Structural
concrete
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2-Part Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation GAF 2-Part
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One or
more BP-AA, SBS-
AA
SBS-AA -90.0
C-94. Structural
concrete
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2-Part Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation GAF 2-Part
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA or
APP-TA -90.0
C-95. Structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN GAF 2-Part (Optional) EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN GAF 2-Part
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One or
more BP-AA, SBS-
AA
SBS-AA -150.0
C-96. Structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN GAF 2-Part (Optional) EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN GAF 2-Part
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA or
APP-TA -150.0
C-97. Structural
concrete Min. 1.5-inch EnergyGuard Ultra GAF 2-Part (Optional) EnergyGuard Ultra GAF 2-Part
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One or
more BP-AA, SBS-
AA
SBS-AA -172.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 52 of 91
TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS)
SEE NOTE 16 FOR VAPOR BARRIER OPTIONS
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
C-98. Structural
concrete Min. 1.5-inch EnergyGuard Ultra GAF 2-Part (Optional) EnergyGuard Ultra GAF 2-Part
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA or
APP-TA -172.5
C-99. Structural
concrete
Min. 1.5-inch EnergyGuard Polyiso
Insulation GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One or
more BP-AA, SBS-
AA
SBS-AA -180.0
C-100. Structural
concrete
Min. 1.5-inch EnergyGuard Polyiso
Insulation GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA or
APP-TA -180.0
C-101. Structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2-Part Min. 0.25-inch DensDeck or DensDeck
Prime GAF 2-Part
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One or
more BP-AA, SBS-
AA
SBS-AA -240.0
C-102. Structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2-Part Min. 0.25-inch DensDeck or DensDeck
Prime GAF 2-Part
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA or
APP-TA -240.0
COLD-APPLIED SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER:
C-103. Structural
concrete
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500 Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation OB500 SBS-CA None SBS-CA -45.0
C-104. Structural
concrete
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH
OB500, LRF-
M, M-OSFA
Min. 0.5-inch EnergyGuard RH HD
Polyiso Insulation, EnergyGuard HD
Polyiso Insulation, EnergyGuard HD Plus
Polyiso Insulation
OB500,
LRF-M, M-
OSFA
SBS-CA or SBS-CA1 None SBS-CA or
SBS-CA1 -97.5
C-105. Structural
concrete
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-CA1 None SBS-CA1 -127.5
C-106. Structural
concrete
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board OB500 SBS-CA1 None SBS-CA1 -172.5
C-107. Structural
concrete
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part SBS-CA1 None SBS-CA1 -127.5
C-108. Structural
concrete
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
GAF 2-Part Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board GAF 2-Part SBS-CA1 None SBS-CA1 -172.5
HYBRID COLD/HOT-APPLIED SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER:
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 53 of 91
TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS)
SEE NOTE 16 FOR VAPOR BARRIER OPTIONS
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
C-109. Primed structural
concrete
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
Hot asphalt
Min. 0.75-inch EnergyGuard Perlite Roof
Insulation (homogeneous), min. 0.5-inch
Structodek High Density Fiberboard Roof
Insulation or EnergyGuard Perlite
Recover Board, min. 0.25-inch DensDeck
Prime or SECUROCK Gypsum-Fiber Roof
Board
Hot asphalt BP-AA or SBS-AA (Optional) BP-AA
or SBS-AA SBS-CA1 -255.0
C-110. Structural
concrete
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500 Min. 0.25-inch DensDeck Prime OB500 BP-AA or SBS-AA (Optional) BP-AA
or SBS-AA SBS-CA1 -127.5
C-111. Structural
concrete
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA
or SBS-AA SBS-CA1 -172.5
C-112. Structural
concrete
Min. 1.5-inch EnergyGuard Polyiso
Insulation GAF 2-Part Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA or SBS-AA (Optional) BP-AA
or SBS-AA SBS-CA1 -180.0
C-113. Structural
concrete
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA or SBS-AA (Optional) BP-AA
or SBS-AA SBS-CA1 -240.0
CONVENTIONAL SYSTEMS WITH POLYSTYRENE BASE INSULATION LAYER:
C-114. Structural
concrete
Min. 1.0-inch Foamular 250 or 2.0-inch
STYROFOAM Deckmate Plus FA OB500 Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA, APP-TA (Optional) SBS-TA,
APP-TA
SBS-TA, APP-
TA -240.0
C-115. Structural
concrete Min. 1.0-inch Foamular 250 OB500 Min. 0.25-inch DensDeck or DensDeck
Prime OB500 BP-AA, SBS-AA,
SBS-TA or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -277.5
C-116. Structural
concrete Min. 1.5-inch, min. 1.25 pcf Insulfoam GAF 2-Part Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -87.5
C-117. Structural
concrete Min. 1.5-inch, min. 1.25 pcf Insulfoam GAF 2-Part
Min. 0.25-inch DensDeck, DensDeck
Prime or SECUROCK Gypsum-Fiber Roof
Board
GAF 2-Part BP-AA, SBS-AA,
SBS-TA or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -87.5
C-118. Structural
concrete Min. 1.5-inch, min. 1.5 pcf Insulfoam GAF 2-Part Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -180.0
C-119. Structural
concrete Min. 1.5-inch, min. 1.5 pcf Insulfoam GAF 2-Part
Min. 0.25-inch DensDeck, DensDeck
Prime or SECUROCK Gypsum-Fiber Roof
Board
GAF 2-Part BP-AA, SBS-AA,
SBS-TA or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -180.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 54 of 91
TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS)
SEE NOTE 16 FOR VAPOR BARRIER OPTIONS
System
No.
Deck
(Note 1)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
C-120. Structural
concrete Min. 1.5-inch, min. 2.0 pcf Insulfoam GAF 2-Part Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -240.0
C-121. Structural
concrete Min. 1.5-inch, min. 2.0 pcf Insulfoam GAF 2-Part
Min. 0.25-inch DensDeck, DensDeck
Prime or SECUROCK Gypsum-Fiber Roof
Board
GAF 2-Part BP-AA, SBS-AA,
SBS-TA or APP-TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -240.0
SELF-ADHERING BASE PLY WITH POLYSTYRENE BASE INSULATION LAYER:
C-122. Structural
concrete Min. 1.0-inch Foamular 250 OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-SA (Optional) SBS-SA SBS-SA -152.5
C-123. Structural
concrete Min. 1.5-inch, min. 1.25 pcf Insulfoam GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part SBS-SA (Optional) SBS-SA SBS-SA -87.5
C-124. Structural
concrete Min. 1.5-inch, min. 1.25 pcf Insulfoam GAF 2-Part Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board primed with D41 primer GAF 2-Part SBS-SA (Optional) SBS-SA SBS-SA -87.5
C-125. Structural
concrete Min. 1.5-inch, min. 1.5 pcf Insulfoam GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part SBS-SA (Optional) SBS-SA SBS-SA -152.5
C-126. Structural
concrete Min. 1.5-inch, min. 1.5 pcf Insulfoam GAF 2-Part Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board primed with D41 primer GAF 2-Part SBS-SA (Optional) SBS-SA SBS-SA -180.0
C-127. Structural
concrete Min. 1.5-inch, min. 2.0 pcf Insulfoam GAF 2-Part Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board primed with D41 primer GAF 2-Part SBS-SA (Optional) SBS-SA SBS-SA -240.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 55 of 91
TABLE 3C: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER
System
No.
Deck
(Note 1) Primer Roof Cover (Note 15) MDP
(psf) Base Ply Ply Cap Ply
CONVENTIONAL SYSTEMS:
C-128. Structural concrete Matrix 307 Premium Asphalt Primer or ASTM D41 primer APP-TA (Optional) APP-TA APP-TA -90.0
C-129. Structural concrete Matrix 307 Premium Asphalt Primer or ASTM D41 primer None None SBS-TA -283.1
C-130. Structural concrete Matrix 307 Premium Asphalt Primer or ASTM D41 primer BP-AA, SBS-AA BP-AA, SBS-AA SBS-AA -442.5
C-131. Structural concrete (Optional) Matrix 307 Premium Asphalt Primer or ASTM
D41 primer SBS-TA (Optional) SBS-TA SBS-TA -465.0
SELF-ADHERING BASE PLY:
C-132. Structural concrete Matrix 307 Premium Asphalt Primer or ASTM D41 primer SBS-SA (Optional) SBS-SA SBS-SA -72.5
C-133. Structural concrete Matrix 307 Premium Asphalt Primer or ASTM D41 primer SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -140.0
VENTING SYSTEMS:
C-134. Structural concrete Matrix 307 Premium Asphalt Primer or ASTM D41 primer GAFGLAS Stratavent Perforated Venting Base Sheet BP-AA, SBS-AA SBS-AA -185.0
COLD-APPLIED SYSTEMS:
C-135. Structrual concrete Matrix 307 Premium Asphalt Primer or ASTM D41 primer BP-AA, BP-CA, SBS-CA (Optional) SBS-CA SBS-CA -307.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 56 of 91
TABLE 4A: LIGHTWEIGHT INSULATING CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
SEE NOTE 16A FOR VAPOR BARRIER OPTIONS
System
No.
Deck
(Note 1)
Lightweight
Concrete (Note 14)
Base Insulation Layer Coverboard Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
CELCORE (FL2037):
LWC-1. Structural
concrete
Celcore Cellular
Concrete (min. 200
psi)
Min. 1.5-inch, min. 1.25 pcf
Insulfoam GAF 2-Part
Min. 0.5-inch Structodek High
Density Fiberboard Roof
Insulation
GAF 2-Part BP-AA, SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -87.5
LWC-2. Structural
concrete
Celcore Cellular
Concrete (min. 200
psi)
Min. 1.5-inch, min. 1.25 pcf
Insulfoam GAF 2-Part
Min. 0.25-inch DensDeck,
DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
GAF 2-Part
BP-AA, SBS-AA,
SBS-TA or APP-
TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -87.5
LWC-3. Structural
concrete
Celcore Cellular
Concrete (min. 200
psi)
Min. 1.5-inch, min. 1.5 pcf
Insulfoam GAF 2-Part
Min. 0.5-inch Structodek High
Density Fiberboard Roof
Insulation
GAF 2-Part BP-AA, SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -180.0
LWC-4. Structural
concrete
Celcore Cellular
Concrete (min. 200
psi)
Min. 1.5-inch, min. 1.5 pcf
Insulfoam GAF 2-Part
Min. 0.25-inch DensDeck,
DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
GAF 2-Part
BP-AA, SBS-AA,
SBS-TA or APP-
TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -180.0
LWC-5. Structural
concrete
Celcore Cellular
Concrete (min. 200
psi)
Min. 1.5-inch, min. 2.0 pcf
Insulfoam GAF 2-Part
Min. 0.5-inch Structodek High
Density Fiberboard Roof
Insulation
GAF 2-Part BP-AA, SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -222.5
LWC-6. Structural
concrete
Celcore Cellular
Concrete (min. 200
psi)
Min. 1.5-inch, min. 2.0 pcf
Insulfoam GAF 2-Part
Min. 0.25-inch DensDeck,
DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
GAF 2-Part
BP-AA, SBS-AA,
SBS-TA or APP-
TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -222.5
ELASTIZELL (FL4994):
LWC-7. Structural
concrete
Elastizell Range II
Lightweight
Insulating Concrete
(min. 200 psi)
(Optional) Min. 1.5-inch
EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN or
EnergyGuard Ultra
OB500
Min. 0.5-inch Structodek High
Density Fiberboard Roof
Insulation
OB500 BP-AA, SBS-AA
(Optional) One or
more BP-AA, SBS-
AA, SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -225.0
LWC-8. Structural
concrete
Elastizell Range II
Lightweight
Insulating Concrete
(min. 200 psi)
(Optional) Min. 1.5-inch
EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN or
EnergyGuard Ultra
OB500
Min. 0.25-inch DensDeck,
DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
OB500
BP-AA, SBS-AA,
SBS-TA or APP-
TA
(Optional) One or
more BP-AA, SBS-
AA, SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -225.0
LWC-9. Structural
concrete
Elastizell Range II
Lightweight
Insulating Concrete
(min. 200 psi)
Min. 2.0-inch, min. 1.0 pcf,
Insulfoam OB500
Min. 0.5-inch Structodek High
Density Fiberboard Roof
Insulation
OB500 BP-AA, SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -120.0
LWC-10. Structural
concrete
Elastizell Range II
Lightweight
Insulating Concrete
(min. 200 psi)
Min. 1.0-inch Foamular 250 OB500
Min. 0.25-inch DensDeck or
DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
OB500
BP-AA, SBS-AA,
SBS-TA or APP-
TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -225.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 57 of 91
TABLE 4A: LIGHTWEIGHT INSULATING CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
SEE NOTE 16A FOR VAPOR BARRIER OPTIONS
System
No.
Deck
(Note 1)
Lightweight
Concrete (Note 14)
Base Insulation Layer Coverboard Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
LWC-11. Structural
concrete
Elastizell Range II
Lightweight
Insulating Concrete
(min. 200 psi)
(Optional) Min. 1.5-inch
EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2-Part
Min. 0.5-inch Structodek High
Density Fiberboard Roof
Insulation
GAF 2-Part BP-AA, SBS-AA
(Optional) One or
more BP-AA, SBS-
AA, SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -180.0
LWC-12. Structural
concrete
Elastizell Range II
Lightweight
Insulating Concrete
(min. 200 psi)
(Optional) Min. 1.5-inch
EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2-Part
Min. 0.25-inch DensDeck,
DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
GAF 2-Part
BP-AA, SBS-AA,
SBS-TA or APP-
TA
(Optional) One or
more BP-AA, SBS-
AA, SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -180.0
LWC-13. Structural
concrete
Elastizell Range II
Lightweight
Insulating Concrete
(min. 200 psi)
(Optional) Min. 1.5-inch
EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2-Part
Min. 0.5-inch Structodek High
Density Fiberboard Roof
Insulation
GAF 2-Part BP-AA, SBS-AA
(Optional) One or
more BP-AA, SBS-
AA, SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -222.5
LWC-14. Structural
concrete
Elastizell Range II
Lightweight
Insulating Concrete
(min. 200 psi)
(Optional) Min. 1.5-inch
EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2-Part
Min. 0.25-inch DensDeck,
DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
GAF 2-Part
BP-AA, SBS-AA,
SBS-TA or APP-
TA
(Optional) One or
more BP-AA, SBS-
AA, SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -222.5
LWC-15. Structural
concrete
Elastizell Range II
Lightweight
Insulating Concrete
(min. 200 psi)
Min. 1.5-inch, min. 1.25 pcf
Insulfoam GAF 2-Part
Min. 0.5-inch Structodek High
Density Fiberboard Roof
Insulation
GAF 2-Part BP-AA, SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -87.5
LWC-16. Structural
concrete
Elastizell Range II
Lightweight
Insulating Concrete
(min. 200 psi)
Min. 1.5-inch, min. 1.25 pcf
Insulfoam GAF 2-Part
Min. 0.25-inch DensDeck,
DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
GAF 2-Part
BP-AA, SBS-AA,
SBS-TA or APP-
TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -87.5
LWC-17. Structural
concrete
Elastizell Range II
Lightweight
Insulating Concrete
(min. 200 psi)
Min. 1.5-inch, min. 1.5 pcf
Insulfoam GAF 2-Part
Min. 0.5-inch Structodek High
Density Fiberboard Roof
Insulation
GAF 2-Part BP-AA, SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -180.0
LWC-18. Structural
concrete
Elastizell Range II
Lightweight
Insulating Concrete
(min. 200 psi)
Min. 1.5-inch, min. 1.5 pcf
Insulfoam GAF 2-Part
Min. 0.25-inch DensDeck,
DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
GAF 2-Part
BP-AA, SBS-AA,
SBS-TA or APP-
TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -180.0
MEARLCRETE (FL13492):
LWC-19. Structural
concrete
Mearlcrete (min.
200 psi)
(Optional) Min. 1.5-inch
EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2-Part
Min. 0.5-inch Structodek High
Density Fiberboard Roof
Insulation
GAF 2-Part BP-AA, SBS-AA
(Optional) One or
more BP-AA, SBS-
AA, SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -240.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 58 of 91
TABLE 4A: LIGHTWEIGHT INSULATING CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
SEE NOTE 16A FOR VAPOR BARRIER OPTIONS
System
No.
Deck
(Note 1)
Lightweight
Concrete (Note 14)
Base Insulation Layer Coverboard Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
LWC-20. Structural
concrete
Mearlcrete (min.
200 psi)
(Optional) Min. 1.5-inch
EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2-Part
Min. 0.25-inch DensDeck,
DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
GAF 2-Part
BP-AA, SBS-AA,
SBS-TA or APP-
TA
(Optional) One or
more BP-AA, SBS-
AA, SBS-TA or APP-
TA
SBS-AA, SBS-
TA or APP-TA -240.0
LWC-21. Structural
concrete
Mearlcrete (min.
200 psi)
Min. 1.5-inch, min. 1.25 pcf
Insulfoam GAF 2-Part
Min. 0.5-inch Structodek High
Density Fiberboard Roof
Insulation
GAF 2-Part BP-AA, SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -87.5
LWC-22. Structural
concrete
Mearlcrete (min.
200 psi)
Min. 1.5-inch, min. 1.25 pcf
Insulfoam GAF 2-Part
Min. 0.25-inch DensDeck,
DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
GAF 2-Part
BP-AA, SBS-AA,
SBS-TA or APP-
TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -87.5
LWC-23. Structural
concrete
Mearlcrete (min.
200 psi)
Min. 1.5-inch, min. 1.5 pcf
Insulfoam GAF 2-Part
Min. 0.5-inch Structodek High
Density Fiberboard Roof
Insulation
GAF 2-Part BP-AA, SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -180.0
LWC-24. Structural
concrete
Mearlcrete (min.
200 psi)
Min. 1.5-inch, min. 1.5 pcf
Insulfoam GAF 2-Part
Min. 0.25-inch DensDeck,
DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
GAF 2-Part
BP-AA, SBS-AA,
SBS-TA or APP-
TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -180.0
LWC-25. Structural
concrete
Mearlcrete (min.
200 psi)
Min. 1.5-inch, min. 2.0 pcf
Insulfoam GAF 2-Part
Min. 0.5-inch Structodek High
Density Fiberboard Roof
Insulation
GAF 2-Part BP-AA, SBS-AA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -240.0
LWC-26. Structural
concrete
Mearlcrete (min.
200 psi)
Min. 1.5-inch, min. 2.0 pcf
Insulfoam GAF 2-Part
Min. 0.25-inch DensDeck,
DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
GAF 2-Part
BP-AA, SBS-AA,
SBS-TA or APP-
TA
(Optional) BP-AA,
SBS-AA, SBS-TA or
APP-TA
SBS-AA, SBS-
TA or APP-TA -240.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 59 of 91
TABLE 4B: LIGHTWEIGHT INSULATING CONCRETE OVER STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
SEE NOTE 16A FOR VAPOR BARRIER OPTIONS
System
No.
Deck
(Note 1)
Lightweight
Concrete
(Note 14)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15)
MDP
(psf) Type Fasteners
(Note 11) Attach Type
Attach
(Notes
6,7,8)
Type
Attach
(Notes
6,7,8)
Base Ply Ply Cap Ply
CELCORE (FL2037):
CONVENTIONAL SYSTEMS:
LWC-27.
Min. 22 ga.
type B,
Grade 33
vented
steel; 5-ft
spans or
min. 2,500
psi
structural
concrete
Celcore Cellular
Concrete (min.
300 psi) with
min. 1 pcf EPS
board and min.
2-inch thick top
coat
GAFGLAS #75
Base Sheet, Tri-
Ply #75 Base
Sheet, GAFGLAS
#80 Ultima Base
Sheet, Stratavent
Nailable Venting
Base Sheet
Drill-Tec
Base Sheet
Fastener
(1.7 in.)
7-inch o.c. at
the 3-inch lap
and 7-inch o.c.
in two equally
spaced,
staggered
center rows
Min. 1.5-inch
EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
Polyiso Insulation
or EnergyGuard RH
Polyiso
Hot
asphalt
Min. 0.75-inch
EnergyGuard Perlite
Roof Insulation
(homogeneous),
Min. 0.5-inch
Structodek High
Density Fiberboard
Roof Insulation or
EnergyGuard Perlite
Recover Board
Hot
asphalt
BP-AA,
SBS-AA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-75.0
LWC-28.
Min. 22 ga.
type B,
Grade 33
vented
steel; 5-ft
spans or
min. 2,500
psi
structural
concrete
Celcore Cellular
Concrete (min.
300 psi) with
min. 1 pcf EPS
board and min.
2-inch thick top
coat
GAFGLAS #75
Base Sheet, Tri-
Ply #75 Base
Sheet, GAFGLAS
#80 Ultima Base
Sheet, Stratavent
Nailable Venting
Base Sheet
Drill-Tec
Base Sheet
Fastener
(1.7 in.)
7-inch o.c. at
the 3-inch lap
and 7-inch o.c.
in two equally
spaced,
staggered
center rows
Min. 1.5-inch
EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
Polyiso Insulation
or EnergyGuard RH
Polyiso
Hot
asphalt
Min. 0.25-inch
DensDeck Prime or
SECUROCK
Gypsum-Fiber Roof
Board
Hot
asphalt
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-AA,
SBS-TA,
APP-TA
-75.0
VENTING SYSTEMS:
LWC-29.
Min. 22 ga.
type B,
Grade 33
vented
steel; 5-ft
spans or
min. 2,500
psi
structural
concrete
Celcore Cellular
Concrete (min.
300 psi) with
min. 1 pcf EPS
board and min.
2-inch thick top
coat
GAFGLAS #75
Base Sheet, Tri-
Ply #75 Base
Sheet, GAFGLAS
#80 Ultima Base
Sheet, Stratavent
Nailable Venting
Base Sheet
Drill-Tec
Base Sheet
Fastener
(1.7 in.)
7-inch o.c. at
the 3-inch lap
and 7-inch o.c.
in two equally
spaced,
staggered
center rows
Min. 1.5-inch
EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
Polyiso Insulation
or EnergyGuard RH
Polyiso
Hot
asphalt
(Optional) Min.
0.25-inch
SECUROCK
Gypsum-Fiber Roof
Board
Hot
asphalt
GAFGLAS
Stratavent
Perforate
d Venting
Base
Sheet
BP-AA,
SBS-AA
SBS-AA,
SBS-TA,
APP-TA
-75.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 60 of 91
TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE OVER STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER
SEE NOTE 16A FOR VAPOR BARRIER OPTIONS
System
No.
Deck
(Note 1)
Lightweight Concrete
(Note 14)
Base Sheet Roof Cover (Note 15) MDP
(psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply
CELCORE (FL2037):
CONVENTIONAL SYSTEMS:
LWC-30.
Min. 22 ga. type B,
Grade 33 vented steel;
6 ft spans or min. 2,500
psi structural concrete
Celcore Cellular Concrete (min. 200 psi)
with min. 1 pcf EPS board and min. 2-
inch thick top coat
GAFGLAS Stratavent
Nailable Venting Base
Sheet
Drill-Tec Base Sheet Fastener
(1.7 in.) or Drill-Tec Base Sheet
Fastener E (1.7 in.)
9-inch o.c. at min. 2-inch laps and
18-inch o.c. in two (2), equally
spaced, staggered center rows
SBS-TA SBS-TA -45.0
LWC-31.
Min. 22 ga. type B,
Grade 33 vented steel;
5-ft spans or min. 2,500
psi structural concrete
Celcore Cellular Concrete (min. 200 psi)
with min. 1 pcf EPS board and min. 2-
inch thick top coat
Ruberoid Mop
Granule, Tri-Ply SBS
Granule Cap Sheet
(granules down)
Drill-Tec Locking Impact Nail
7-inch o.c. at min. 4-inch side laps
and 7-inch o.c. in two, equally
spaced staggered center rows.
BP-AA or SBS-
AA
SBS-AA,
SBS-TA
or APP-
TA
-75.0
LWC-32.
Min. 22 ga. type B,
Grade 33 vented steel;
5-ft spans or min. 2,500
psi structural concrete
Celcore Cellular Concrete (min. 300 psi)
with min. 1 pcf EPS board and min. 2-
inch thick top coat
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima
Base Sheet, GAFGLAS
Stratavent Nailable
Venting Base Sheet
Drill-Tec Base Sheet Fastener
(1.7)
7-inch o.c. at min. 3-inch side laps
and 7-inch o.c. in two, equally
spaced staggered center rows.
Two plies BP-
AA or SBS-AA SBS-AA -75.0
HYBRID HOT/COLD-APPLIED SYSTEMS:
LWC-33.
Min. 22 ga., type B,
Grade 33 steel; 6 ft
spans or min. 2,500 psi
structural concrete
Celcore Cellular Concrete (min. 300 psi)
with min. 1 pcf EPS board and min. 2-
inch thick top coat
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima
Base Sheet, GAFGLAS
Stratavent Nailable
Venting Base Sheet
Drill-Tec Base Sheet Fastener
(1.7)
12-inch o.c. at min. 2-inch side
laps and 12-inch o.c. at three
equally spaced staggered center
rows.
BP-AA or SBS-
AA SBS-CA1 -45.0
LWC-34.
Min. 22 ga., type B,
Grade 33 steel; 6 ft
spans or min. 2,500 psi
structural concrete
Celcore Cellular Concrete (min. 300 psi)
with min. 1 pcf EPS board and min. 2-
inch thick top coat
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima
Base Sheet, GAFGLAS
Stratavent Nailable
Venting Base Sheet
Drill-Tec Base Sheet Fastener
(1.7)
9-inch o.c. at min. 2-inch side laps
and 9-inch o.c. at two equally
spaced staggered center rows.
BP-AA or SBS-
AA SBS-CA1 -45.0
LWC-35.
Min. 22 ga., type B,
Grade 33 steel; 6 ft
spans or min. 2,500 psi
structural concrete
Celcore Cellular Concrete (min. 300 psi)
with min. 1 pcf EPS board and min. 2-
inch thick top coat
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima
Base Sheet, GAFGLAS
Stratavent Nailable
Venting Base Sheet
Drill-Tec Base Sheet Fastener
(1.7)
7.5-inch o.c. at min. 2-inch side
laps and 7.5-inch o.c. at one
center row.
BP-AA or SBS-
AA SBS-CA1 -45.0
LWC-36.
Min. 22 ga., type B,
Grade 33 steel; 6 ft
spans or min. 2,500 psi
structural concrete
Celcore Cellular Concrete (min. 300 psi)
with min. 1 pcf EPS board and min. 2-
inch thick top coat
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima
Base Sheet, GAFGLAS
Stratavent Nailable
Venting Base Sheet
Drill-Tec Base Sheet Fastener
(1.7)
9-inch o.c. at min. 3-inch side laps
and 18-inch o.c. at two equally
spaced staggered center rows.
BP-AA or SBS-
AA SBS-CA1 -45.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 61 of 91
TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE OVER STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER
SEE NOTE 16A FOR VAPOR BARRIER OPTIONS
System
No.
Deck
(Note 1)
Lightweight Concrete
(Note 14)
Base Sheet Roof Cover (Note 15) MDP
(psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply
LWC-37.
Min. 22 ga., type B,
Grade 33 steel; 5 ft
spans or min. 2,500 psi
structural concrete
Celcore Cellular Concrete (min. 300 psi)
with min. 1 pcf EPS board and min. 2-
inch thick top coat
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima
Base Sheet, GAFGLAS
Stratavent Nailable
Venting Base Sheet
Drill-Tec Base Sheet Fastener
(1.7)
7-inch o.c. at min. 3-inch side laps
and 7-inch o.c. at two equally
spaced staggered center rows.
BP-AA or SBS-
AA SBS-CA1 -75.0
ELASTIZELL (FL4994):
LWC-38.
Min. 22 ga. type B,
Grade 33 vented steel;
6 ft spans or min. 2,500
psi structural concrete
Elastizell Range II Lightweight Insulating
Concrete (min. 200 psi) with min. 1 pcf
EPS board and min. 2-inch thick top
coat
GAFGLAS Stratavent
Nailable Venting Base
Sheet
Drill-Tec Base Sheet Fastener
(1.7 in.) or Drill-Tec Base Sheet
Fastener E (1.7 in.)
9-inch o.c. at min. 2-inch laps and
18-inch o.c. in two (2), equally
spaced, staggered center rows
SBS-TA SBS-TA -45.0
MEARLCRETE (FL13492):
CONVENTIONAL SYSTEMS:
LWC-39.
Min. 22 ga. type B,
Grade 33 vented steel;
6 ft spans or min. 2,500
psi structural concrete
Mearlcrete (min. 300 psi) with min. 1
pcf EPS board and min. 2-inch thick top
coat
Ruberoid Mop Plus
Granule (granules
down)
Drill-Tec Locking Impact Nail
6-inch o.c. at min. 4-inch side laps
and 9-inch o.c. in two, equally
spaced staggered center rows.
(Optional) BP-
AA, SBS-AA,
SBS-TA or
APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-45.0
LWC-40.
Min. 22 ga. type B,
Grade 33 vented steel;
6 ft spans or min. 2,500
psi structural concrete
Mearlcrete (min. 300 psi) with min. 1
pcf EPS board and min. 2-inch thick top
coat
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima
Base Sheet, GAFGLAS
Stratavent Nailable
Venting Base Sheet
Drill-Tec Base Sheet Fastener
(1.2 in.)
7.5-inch o.c. at min. 4-inch laps
and 12-inch o.c. in three, equally
spaced, staggered center rows
(Optional) BP-
AA, SBS-AA,
SBS-TA or
APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-52.5
LWC-41.
Min. 22 ga. type B,
Grade 33 vented steel;
6 ft spans or min. 2,500
psi structural concrete
Mearlcrete (min. 300 psi) with min. 1
pcf EPS board and min. 2-inch thick top
coat
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima
Base Sheet, GAFGLAS
Stratavent Nailable
Venting Base Sheet
Drill-Tec Base Sheet Fastener
(1.7 in.) or Drill-Tec Base Sheet
Fastener E (1.7 in.)
7-inch o.c. at min. 4-inch laps and
7-inch o.c. in two (2), equally
spaced, staggered center rows
(Optional) BP-
AA, SBS-AA,
SBS-TA or
APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-52.5
LWC-42. Structural concrete
Mearlcrete (min. 300 psi) with optional
min. 1 pcf Corrugated EPS Holey Board
and min. 2-inch thick top coat
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS Stratavent
Nailable Venting Base
Sheet
Drill-Tec Base Sheet Fastener
(1.7)
7-inch o.c. at min. 4-inch laps and
7-inch o.c. in two, equally spaced,
staggered center rows
SBS-TA SBS-TA -52.5
LWC-43.
Min. 22 ga. type B,
Grade 33 vented steel;
6 ft spans or min. 2,500
psi structural concrete
Mearlcrete (min. 742 psi) min. 2-inch
thick top coat GAFGLAS FlexPly 6 Drill-Tec Base Sheet Fastener
(1.2)
7-inch o.c. at min. 4-inch side laps
and 7-inch o.c. in two, equally
spaced staggered center rows.
(Optional) BP-
AA, SBS-AA
SBS-AA
(polyester
reinforced,
D6164 only)
-52.5
SELF-ADHERING BASE PLY:
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 62 of 91
TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE OVER STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER
SEE NOTE 16A FOR VAPOR BARRIER OPTIONS
System
No.
Deck
(Note 1)
Lightweight Concrete
(Note 14)
Base Sheet Roof Cover (Note 15) MDP
(psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply
LWC-44.
Min. 22 ga. type B,
Grade 33 vented steel;
6 ft spans or min. 2,500
psi structural concrete
Mearlcrete (min. 300 psi) with min. 1
pcf EPS board and min. 2-inch thick top
coat
StormSafe Anchor
Sheet
Drill-Tec Base Sheet Fastener
(1.2 in.)
7.5-inch o.c. at min. 4-inch laps
and 12-inch o.c. in three, equally
spaced, staggered center rows
(Optional)
SBS-SA SBS-SA -52.5
PRE-EXISTENT CELLULAR LIGHTWEIGHT CONCRETE:
CONVENTIONAL SYSTEMS:
LWC-45.
Min. 22 ga. type BV,
Grade 33 steel; 6 ft
spans or min. 2,500 psi
structural concrete
Min 200 psi pre-existent cellular LWC Ruberoid Mop
Smooth
Drill-Tec XHD Fasteners with Drill-
Tec Eyehook AccuSeam Plates,
Drill-Tec 2-3/8 in. Barbed XHD
Plates, Dekfast Galvalume Steel
Round 2-3/8” 20-Ga. Barbed Plates
or Trufast 2.4” Barbed Metal Seam
Plates (MCRF > 345 lbf)
Fasten through LWC to structural
deck 18-inch o.c. within 5-inch
wide, torched or heat-welded
side laps
(Optional)
SBS-TA SBS-TA -37.5
LWC-46.
Min. 22 ga. type BV,
Grade 33 steel; 6 ft
spans or min. 2,500 psi
structural concrete
Min 200 psi pre-existent cellular LWC Ruberoid HW Smooth
Drill-Tec XHD Fasteners with Drill-
Tec 2-3/8 in. Barbed XHD Plates or
Trufast 2.4” Barbed Metal Seam
Plates (MCRF > 345 lbf)
Fasten through LWC to structural
deck 18-inch o.c. within 5-inch
wide, torched or heat-welded
side laps
(Optional)
SBS-TA SBS-TA -37.5
LWC-47.
Min. 22 ga. type B,
Grade 33 steel; 6’-
6”spans or min. 2,500
psi structural concrete
Min 250-300 psi pre-existent cellular
LWC with min. 1 pcf EPS board and min.
2-inch thick top coat
Ruberoid Mop
Smooth
#14 HD Drill-Tec fasteners and
2” Drill-Tec Double-Barbed
Round Steel Plates
Fasten through LWC to structural
deck 6-inch o.c. within 4-inch
heat welded side laps
(Optional)
SBS-TA SBS-TA -52.5
LWC-48.
Min. 22 ga. type BV,
Grade 33 steel; 6 ft
spans, or min. 2,500 psi
structural concrete
Min. 340 psi, min. 2-inch thick pre-
existent cellular lightweight insulating
concrete; Note: To qualify the pre-existent
LWIC under this assembly, the selected
fastener shall achieve an average withdrawal
of 60 lbf or greater when tested per
ANSI/SPRI FX-1 or TAS105.
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima
Base Sheet, GAFGLAS
Stratavent Nailable
Venting Base Sheet,
Ruberoid 20 Smooth
Drill-Tec Base Sheet Fastener
(1.7 in.) or Drill-Tec Base Sheet
Fastener E (1.7 in.), Drill-Tec
Locking Impact Nail, Drill-Tec DL
1.7” Base Sheet Fastener
7-inch o.c. at min. 4-inch side laps
and 7-inch o.c. in two (2), equally
spaced staggered center rows.
SBS-AA, SBS-
TA
SBS-AA,
SBS-TA,
APP-TA
-52.5
LWC-49.
Min. 22 ga. type BV,
Grade 33 steel; 6 ft
spans or min. 2,500 psi
structural concrete
Min 200 psi pre-existent cellular LWC Ruberoid Mop
Smooth
Drill-Tec XHD Fasteners with Drill-
Tec Eyehook AccuSeam Plates,
Drill-Tec 2-3/8 in. Barbed XHD
Plates, Dekfast Galvalume Steel
Round 2-3/8” 20-Ga. Barbed Plates
or Trufast 2.4” Barbed Metal Seam
Plates (MCRF > 345 lbf)
Fasten through LWC to structural
deck 12-inch o.c. within 5-inch
wide, torched or heat-welded
side laps
(Optional)
SBS-TA SBS-TA -60.0
LWC-50.
Min. 22 ga. type BV,
Grade 33 steel; 6 ft
spans or min. 2,500 psi
structural concrete
Min 200 psi pre-existent cellular LWC Ruberoid HW Smooth
Drill-Tec XHD Fasteners with Drill-
Tec 2-3/8 in. Barbed XHD Plates or
Trufast 2.4” Barbed Metal Seam
Plates (MCRF > 345 lbf)
Fasten through LWC to structural
deck 12-inch o.c. within 5-inch
wide, torched or heat-welded
side laps
(Optional)
SBS-TA SBS-TA -60.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 63 of 91
TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE OVER STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER
SEE NOTE 16A FOR VAPOR BARRIER OPTIONS
System
No.
Deck
(Note 1)
Lightweight Concrete
(Note 14)
Base Sheet Roof Cover (Note 15) MDP
(psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply
LWC-51.
Min. 22 ga. type B,
Grade 33 steel; 6 ft
spans or min. 2,500 psi
structural concrete
Min 250-300 psi pre-existent cellular
LWC with min. 1 pcf EPS board and min.
2-inch thick top coat
GAFGLAS FlexPly 6 Note 2
Fasten through LWC to structural
deck 12-inch o.c. at 4-inch side
laps and 12-inch o.c. in two,
equally spaced staggered center
rows.
(Optional) BP-
AA, SBS-AA
SBS-AA,
SBS-TA -67.5
LWC-52.
Min. 22 ga., type BV,
Grade 40 steel at max. 6
ft spans or min. 2,500
psi structural concrete
Re-Roof Only: Min. 210 psi, min. 2-inch
thick pre-existent cellular lightweight
insulating concrete; Note: To qualify the
pre-existent LWIC under this assembly, the
selected fastener shall achieve an average
withdrawal of 95 lbf or greater when tested
per ANSI/SPRI FX-1 or TAS105.
Ruberoid 20 Smooth
Drill-Tec Base Sheet Fastener
(1.7 in.) or Drill-Tec Base Sheet
Fastener E (1.7 in.), Drill-Tec
Locking Impact Nail
7-inch o.c. at min. 4-inch laps and 7-
inch o.c. in two, equally spaced,
staggered center rows
Ruberoid HW
25 Smooth or
Ruberoid HW
Smooth, torch
applied
SBS-TA,
APP-TA -82.5
LWC-53.
Min. 22 ga., type BV,
Grade 40 steel at max. 6
ft spans or min. 2,500
psi structural concrete
Re-Roof Only: Min. 210 psi, min. 2-inch
thick pre-existent cellular lightweight
insulating concrete; Note: To qualify the
pre-existent LWIC under this assembly, the
selected fastener shall achieve an average
withdrawal of 95 lbf or greater when tested
per ANSI/SPRI FX-1 or TAS105.
GAFGLAS #80 Ultima
Base Sheet or GAFGLAS
Stratavent Nailable
Venting Base Sheet
Drill-Tec Base Sheet Fastener
(1.7 in.), Drill-Tec Locking Impact
Nail
7-inch o.c. at min. 4-inch laps and 7-
inch o.c. in two, equally spaced,
staggered center rows
Ruberoid HW
25 Smooth or
Ruberoid HW
Smooth, torch
applied
SBS-TA,
APP-TA -82.5
LWC-54.
Min. 22 ga. type B,
Grade 33 steel; 5-ft
spans or min. 2,500 psi
structural concrete
Min 250 psi pre-existent cellular LWC
with optional min. 1 pcf EPS board and
min. 2-inch thick top coat
Ruberoid HW Granule
(granules down) Note 2
Fasten through LWC to structural
deck 12-inch o.c. at 4-inch side
laps and 12-inch o.c. in two,
equally spaced staggered center
rows.
(Optional)
SBS-TA
SBS-TA
(polyester,
D6164 only)
-97.5
TABLE 4D: LIGHTWEIGHT INSULATING CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER
SEE NOTE 16A FOR VAPOR BARRIER OPTIONS
System No. Deck
(Note 1)
Lightweight Concrete
(Note 14) Primer Roof Cover (Note 15) MDP
(psf) Base Ply Ply Cap Ply
CELCORE (FL2037):
LWC-55. Structural concrete Min. 250-300 psi Celcore Cellular Concrete Matrix 307 Premium Asphalt
Primer or ASTM D41 SBS-SA None SBS-TA -52.5
LWC-56. Structural concrete Min. 250-300 psi Celcore Cellular Concrete TOPCOAT PRECOTE SBS-SA None SBS-TA -100.0
ELASTIZELL (FL4994):
LWC-57. Structural concrete Min. 250-300 psi Elastizell Lightweight Insulating Concrete Matrix 307 Premium Asphalt
Primer or ASTM D41 SBS-SA None SBS-SA -137.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 64 of 91
TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Notes 1&12)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
CONVENTIONAL SYSTEMS:
CWF-1.
Existing
Tectum (re-
roof only)
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard
RN
OB500 Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation OB500 BP-AA, SBS-AA
(Optional) One or more
BP-AA, SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0
CWF-2.
Existing
Tectum (re-
roof only)
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard
RN
OB500 Min. 0.25-inch DensDeck, DensDeck Prime
or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS-AA, SBS-
TA or APP-TA
(Optional) One or more
BP-AA, SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-45.0
CWF-3.
Existing
Tectum (re-
roof only)
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard
RN
GAF 2-Part Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA
(Optional) One or more
BP-AA, SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-52.5
CWF-4.
Existing
Tectum (re-
roof only)
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard
RN
GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime
or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-
TA or APP-TA
(Optional) One or more
BP-AA, SBS-AA, SBS-TA or
APP-TA
SBS-AA,
SBS-TA or
APP-TA
-52.5
SELF-ADHERING BASE PLY:
CWF-5.
Existing
Tectum (re-
roof only)
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard
RN
OB500 Min. 0.25-inch DensDeck, DensDeck Prime
or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA or APP-
TA
SBS-TA or
APP-TA -45.0
CWF-6.
Existing
Tectum (re-
roof only)
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard
RN
GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime
or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-SA (Optional) SBS-TA or APP-
TA
SBS-TA or
APP-TA -52.5
TABLE 5B: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15)
MDP
(psf) Type Fasteners
(Note 11) Attach Type
Attach
(Notes
6,7,8)
Type
Attach
(Notes
6,7,8)
Base Ply Ply Cap Ply
CONVENTIONAL SYSTEMS:
CWF-7.
Existing
Tectum (re-
roof only)
GAFGLAS #75 Base Sheet, Tri-
Ply #75 Base Sheet, #80 Ultima
Base Sheet, Stratavent
Nailable Venting Base Sheet,
Ruberoid 20 Smooth, Mop
Smooth
Min. 1.8-inch
Drill-Tec
Locking Impact
Nail
9-inch o.c. at the 3-
inch lap and 18-inch
o.c. in two, equally
spaced, staggered
center rows
(Optional) Min.
1-inch
EnergyGuard
Hot
asphalt
Min. 0.25-inch
DensDeck, DensDeck
Prime or SECUROCK
Gypsum-Fiber Roof
Board
Hot
asphalt
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
(Optional)
BP-AA, SBS-
AA, SBS-TA,
APP-TA
SBS-TA,
APP-TA -45.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 65 of 91
TABLE 5B: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15)
MDP
(psf) Type Fasteners
(Note 11) Attach Type
Attach
(Notes
6,7,8)
Type
Attach
(Notes
6,7,8)
Base Ply Ply Cap Ply
CWF-8.
Existing
Tectum (re-
roof only)
GAFGLAS #75 Base Sheet, Tri-
Ply #75 Base Sheet, #80 Ultima
Base Sheet, Stratavent
Nailable Venting Base Sheet,
Ruberoid 20 Smooth, Mop
Smooth
Min. 1.8-inch
Drill-Tec
Locking Impact
Nail
9-inch o.c. at the 3-
inch lap and 18-inch
o.c. in two, equally
spaced, staggered
center rows
(Optional) Min.
1-inch
EnergyGuard
Hot
asphalt
Min. 0.5-inch
Structodek High
Density Fiberboard
Roof Insulation or
min. 0.75-inch
EnergyGuard Perlite
Roof Insulation
(homogeneous)
Hot
asphalt
BP-AA,
SBS-AA
(Optional)
BP-AA, SBS-
AA, SBS-TA,
APP-TA
SBS-TA,
APP-TA -45.0*
CWF-9.
Min. 2-inch
Tectum I
Plank
GAFGLAS #75 Base Sheet, Tri-
Ply #75 Base Sheet, #80 Ultima
Base Sheet, Stratavent
Nailable Venting Base Sheet,
Ruberoid 20 Smooth, Mop
Smooth
Min. 1.8-inch
Drill-Tec
Locking Impact
Nail
6-inch o.c. at the 3-
inch lap and 6-inch o.c.
in two, equally spaced,
staggered center rows
Min. 1-inch
EnergyGuard
Polyiso
Insulation
Hot
asphalt
Min. 0.75-inch
EnergyGuard Perlite
Roof Insulation
(homogeneous), min.
0.5-inch Structodek
High Density
Fiberboard Roof
Insulation or
EnergyGuard Perlite
Recover Board or
min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
Hot
asphalt
BP-AA,
SBS-AA
(Optional)
BP-AA, SBS-
AA
SBS-AA -60.0
CWF-10.
Min. 2-inch
Tectum I
Plank
GAFGLAS #75 Base Sheet, Tri-
Ply #75 Base Sheet, #80 Ultima
Base Sheet, Stratavent
Nailable Venting Base Sheet,
Ruberoid 20 Smooth, Mop
Smooth
Min. 1.8-inch
Drill-Tec
Locking Impact
Nail
6-inch o.c. at the 3-
inch lap and 6-inch o.c.
in two, equally spaced,
staggered center rows
Min. 1-inch
EnergyGuard
Polyiso
Insulation
Hot
asphalt
Min. 0.25-inch
SECUROCK Gypsum-
Fiber Roof Board
Hot
asphalt
SBS-TA or
APP-TA
(Optional)
SBS-TA or
APP-TA
SBS-TA
or APP-
TA
-60.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 66 of 91
TABLE 5C: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Sheet Roof Cover (Note 15) MDP
(psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply
CONVENTIONAL SYSTEMS:
CWF-11.
Existing
Tectum (re-
roof only)
GAFGLAS Ply 4, Tri-Ply Ply 4 Ply Sheet, GAFGLAS FlexPly 6,
GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent
Nailable Venting Base Sheet
Drill-Tec LD Fasteners
and Drill-Tec LD Plates
9-inch o.c. at the 4-inch lap and 12-inch o.c. in
two, equally spaced, staggered center rows
(Optional) BP-
AA, SBS-AA or
SBS-TA
SBS-AA or
SBS-TA -30.0
CWF-12.
Existing
Tectum (re-
roof only)
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, #80
Ultima Base Sheet, Stratavent Nailable Venting Base Sheet,
Ruberoid 20 Smooth, Mop Smooth
Min. 1.8-inch Drill-Tec
Locking Impact Nail
9-inch o.c. at the 3-inch lap and 18-inch o.c. in
two, equally spaced, staggered center rows BP-AA, SBS-AA
SBS-AA,
SBS-TA or
APP-TA
-45.0*
CWF-13.
Existing
Tectum (re-
roof only)
Ruberoid 20 Smooth Drill-Tec LD Fasteners
and Drill-Tec LD Plates
9-inch o.c. at the 4-inch lap and 12-inch o.c. in
two, equally spaced, staggered center rows
(Optional) BP-
AA, SBS-AA or
SBS-TA
SBS-AA or
SBS-TA -60.0
CWF-14.
Existing
Tectum (re-
roof only)
Ruberoid HW 25 Smooth Drill-Tec LD Fasteners
and Drill-Tec LD Plates
9-inch o.c. at the 4-inch lap and 12-inch o.c. in
two, equally spaced, staggered center rows
(Optional) SBS-
TA SBS-TA -60.0
CWF-15.
Existing
Tectum (re-
roof only)
GAFGLAS Ply 4, Tri-Ply Ply 4 Ply Sheet, GAFGLAS FlexPly 6,
GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent
Nailable Venting Base Sheet or Ruberoid 20 Smooth
Drill-Tec LD Fasteners
and Drill-Tec LD Plates
7-inch o.c. at the 4-inch lap and 7-inch o.c. in
two, equally spaced, staggered center rows
(Optional) BP-
AA, SBS-AA or
SBS-TA
SBS-AA or
SBS-TA -67.5
CWF-16.
Existing
Tectum (re-
roof only)
Ruberoid HW 25 Smooth Drill-Tec LD Fasteners
and Drill-Tec LD Plates
7-inch o.c. at the 4-inch lap and 7-inch o.c. in
two, equally spaced, staggered center rows
(Optional) SBS-
TA SBS-TA -67.5
CWF-17.
Min. 2-inch
Tectum I
Plank
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, #80
Ultima Base Sheet, Stratavent Nailable Venting Base Sheet,
Ruberoid 20 Smooth, Mop Smooth
Min. 1.8-inch Drill-Tec
Locking Impact Nail
6-inch o.c. at the 4-inch lap and 6-inch o.c. in
two, equally spaced, staggered center rows
(Optional) SBS-
AA or SBS-TA
SBS-AA or
SBS-TA -75.0
HYBRID HOT/COLD-APPLIED SYSTEMS:
CWF-18.
Existing
Tectum (re-
roof only)
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS
#80 Ultima Base Sheet, GAFGLAS Stratavent Nailable
Venting Base Sheet
Min. 1.8-inch Drill-Tec
Locking Impact Nail
9-inch o.c. at the 2-inch lap and 9-inch o.c. at
two, equally spaced, staggered center rows BP-AA or SBS-AA SBS-CA1 -45.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 67 of 91
TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Notes 1 & 12)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
CONVENTIONAL SYSTEMS:
G-1. Existing sound gypsum
or gypsum plank
Min. 1-inch EnergyGuard Polyiso Insulation,
EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN
OB500 Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA (Optional) SBS-
TA SBS-TA -190.0
SELF-ADHERING BASE PLY:
G-2. Existing sound gypsum
or gypsum plank
Min. 1-inch EnergyGuard Polyiso Insulation
or EnergyGuard RH OB500 (Optional) Additional layer(s) of base
insulation OB500 SBS-SA None SBS-SA -87.5
G-3. Existing sound gypsum
or gypsum plank
Min. 1-inch EnergyGuard Polyiso Insulation,
EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN
OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber
Roof Board OB500 SBS-SA (Optional) SBS-
TA, APP-TA
SBS-TA,
APP-TA -105.0
G-4. Existing sound gypsum
or gypsum plank
Min. 1-inch EnergyGuard Polyiso Insulation
or EnergyGuard RN OB500 (Optional) Additional layer(s) of base
insulation OB500 SBS-SA (Optional) SBS-
TA, APP-TA
SBS-TA,
APP-TA -147.5
TABLE 6B: GYPSUM DECKS – REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15)
MDP
(psf) Type Fasteners
(Note 11) Attach Type
Attach
(Notes
6,7,8)
Type
Attach
(Notes
6,7,8)
Base Ply Ply Cap Ply
CONVENTIONAL SYSTEMS:
G-5.
Existing
sound
gypsum or
gypsum
plank
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet, #80
Ultima Base Sheet,
Stratavent Nailable Venting
Base Sheet, Ruberoid 20
Smooth, Mop Smooth
Min. 1.8-inch
Drill-Tec Locking
Impact Nail
9-inch o.c. at the 3-
inch lap and 18-inch
o.c. in two, equally
spaced, staggered
center rows
(Optional) Min.
1-inch
EnergyGuard
Hot
asphalt
Min. 0.25-inch DensDeck,
DensDeck Prime or
SECUROCK Gypsum-Fiber
Roof Board
Hot
asphalt
BP-AA, SBS-
AA, SBS-TA,
APP-TA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-TA,
APP-TA -45.0*
G-6.
Existing
sound
gypsum or
gypsum
plank
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet, #80
Ultima Base Sheet,
Stratavent Nailable Venting
Base Sheet, Ruberoid 20
Smooth, Mop Smooth
Min. 1.8-inch
Drill-Tec Locking
Impact Nail
9-inch o.c. at the 3-
inch lap and 18-inch
o.c. in two, equally
spaced, staggered
center rows
(Optional) Min.
1-inch
EnergyGuard
Hot
asphalt
Min. 0.5-inch Structodek
High Density Fiberboard
Roof Insulation or min.
0.75-inch EnergyGuard
Perlite Roof Insulation
(homogeneous)
Hot
asphalt
BP-AA, SBS-
AA
(Optional)
BP-AA,
SBS-AA,
SBS-TA,
APP-TA
SBS-TA,
APP-TA -45.0*
VENTING SYSTEMS:
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 68 of 91
TABLE 6B: GYPSUM DECKS – REROOF (TEAR-OFF)
SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15)
MDP
(psf) Type Fasteners
(Note 11) Attach Type
Attach
(Notes
6,7,8)
Type
Attach
(Notes
6,7,8)
Base Ply Ply Cap Ply
G-7.
Existing
sound
gypsum or
gypsum
plank
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base Sheet
Min. 1.8-inch
Drill-Tec Locking
Impact Nail or
Drill-Tec Base
Sheet Fastener
(1.2 in)
9-inch o.c. at the 2-
inch lap and 18-inch
o.c. in two, equally
spaced, staggered
center rows
Min. 1.5-inch
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN
Hot
asphalt
Min. 0.5-inch
EnergyGuard Perlite
Recover Board or min.
0.75-inch EnergyGuard
Perlite Roof Insulation
(homogeneous)
Hot
asphalt
GAFGLAS
Stratavent
Perforated
Venting
Base Sheet
BP-AA,
SBS-AA
SBS-AA
or SBS-
TA
-45.0*
G-8.
Existing
sound
gypsum or
gypsum
plank
GAFGLAS Stratavent
Nailable Venting Base Sheet
Min. 1.8-inch
Drill-Tec Locking
Impact Nail
9-inch o.c. at the 2-
inch lap and 18-inch
o.c. in two, equally
spaced, staggered
center rows
Min. 1.5-inch
EnergyGuard RA,
EnergyGuard RH,
EnergyGuard RN
Hot
asphalt None N/A
GAFGLAS
Stratavent
Perforated
Venting
Base Sheet
Two plies
SBS-AA SBS-AA -45.0*
TABLE 6C: GYPSUM DECKS - REROOF (TEAR-OFF)
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Insulation Layer
(Note 13)
Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply
G-9. Existing sound gypsum or
gypsum plank
(Optional) One or more
layers, any combination,
loose laid
Min. 0.75-inch EnergyGuard
Perlite Roof Insulation
(homogeneous)
Drill-Tec Polymer Gyptec
Fastener with Drill-Tec
Gyptec Plate
1 per 1.3 ft2 BP-AA or
SBS-AA
(Optional) BP-
AA, SBS-AA or
SBS-TA
SBS-AA or
SBS-TA -62.5*
TABLE 6D: GYPSUM DECKS - REROOF (TEAR-OFF)
SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Sheet Roof Cover (Note 15) MDP
(psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply
CONVENTIONAL SYSTEMS:
G-10. Existing sound gypsum
or gypsum plank
GAFGLAS Ply 4, Tri-Ply Ply 4 Ply Sheet, GAFGLAS
FlexPly 6, GAFGLAS #80 Ultima Base Sheet,
GAFGLAS Stratavent Nailable Venting Base Sheet
Drill-Tec LD Fasteners
and Drill-Tec LD Plates
9-inch o.c. at the 4-inch lap and 12-inch o.c. in two,
equally spaced, staggered center rows
(Optional) BP-
AA, SBS-AA or
SBS-TA
SBS-AA or
SBS-TA -30.0
G-11. Existing sound gypsum
or gypsum plank GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Locking Impact
Nail
9-inch o.c. at min. 2-inch laps and 18-inch o.c. in
two, equally spaced, staggered center rows BP-AA, SBS-AA SBS-AA, SBS-
TA or APP-TA -45.0*
G-12. Existing sound gypsum
or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet Drill-Tec Base Sheet
Fastener (1.2 in.)
9-inch o.c. at min. 2-inch laps and 18-inch o.c. in
two, equally spaced, staggered center rows SBS-TA SBS-TA -45.0*
G-13. Existing sound gypsum
or gypsum plank
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base Sheet or GAFGLAS
Stratavent Nailable Venting Base Sheet
Drill-Tec Base Sheet
Fastener (1.2 in.)
9-inch o.c. at min. 2-inch laps and 12-inch o.c. in
two, equally spaced, staggered center rows
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-
TA or APP-TA -50.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 69 of 91
TABLE 6D: GYPSUM DECKS - REROOF (TEAR-OFF)
SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Deck
(Note 1)
Base Sheet Roof Cover (Note 15) MDP
(psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply
G-14. Existing sound gypsum
or gypsum plank Ruberoid 20 Smooth Drill-Tec LD Fasteners
and Drill-Tec LD Plates
9-inch o.c. at the 4-inch lap and 12-inch o.c. in two,
equally spaced, staggered center rows
(Optional) BP-
AA, SBS-AA or
SBS-TA
SBS-AA or
SBS-TA -60.0
G-15. Existing sound gypsum
or gypsum plank Ruberoid HW 25 Smooth Drill-Tec LD Fasteners
and Drill-Tec LD Plates
9-inch o.c. at the 4-inch lap and 12-inch o.c. in two,
equally spaced, staggered center rows
(Optional) SBS-
TA SBS-TA -60.0
G-16. Existing sound gypsum
or gypsum plank
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base Sheet or GAFGLAS
Stratavent Nailable Venting Base Sheet
Drill-Tec Base Sheet
Fastener (1.2 in.)
9-inch o.c. at min. 2-inch laps and 9-inch o.c. in
three, equally spaced, staggered center rows
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA, SBS-
TA or APP-TA -57.5*
G-17. Existing sound gypsum
or gypsum plank
GAFGLAS Ply 4, Tri-Ply Ply 4 Ply Sheet, GAFGLAS
FlexPly 6, GAFGLAS #80 Ultima Base Sheet,
GAFGLAS Stratavent Nailable Venting Base Sheet
or Ruberoid 20 Smooth
Drill-Tec LD Fasteners
and Drill-Tec LD Plates
7-inch o.c. at the 4-inch lap and 7-inch o.c. in two,
equally spaced, staggered center rows
(Optional) BP-
AA, SBS-AA or
SBS-TA
SBS-AA or
SBS-TA -67.5
G-18. Existing sound gypsum
or gypsum plank Ruberoid HW 25 Smooth Drill-Tec LD Fasteners
and Drill-Tec LD Plates
7-inch o.c. at the 4-inch lap and 7-inch o.c. in two,
equally spaced, staggered center rows
(Optional) SBS-
TA SBS-TA -67.5
HYBRID HOT/COLD-APPLIED SYSTEMS:
G-19. Existing sound gypsum
or gypsum plank
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base Sheet, GAFGLAS
Stratavent Nailable Venting Base Sheet
Drill-Tec Locking Impact
Nail
9-inch o.c. at min. 2-inch laps and 18-inch o.c. at
two, equally spaced, staggered center rows BP-AA or SBS-AA SBS-CA1 -45.0*
G-20. Existing sound gypsum
or gypsum plank
GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base Sheet, GAFGLAS
Stratavent Nailable Venting Base Sheet
Drill-Tec Locking Impact
Nail
7.5-inch o.c. at min. 2-inch laps and 7.5-inch o.c. at
one center rows BP-AA or SBS-AA SBS-CA1 -45.0*
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 70 of 91
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY)
System
No.
Substrate
(Notes 1 & 12)
Base Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
CONVENTIONAL SYSTEMS WITH BASE INSULATION LAYER ONLY
R-1. Existing asphaltic roof cover Min. 0.75-inch EnergyGuard Perlite Roof
Insulation (homogeneous) Hot asphalt BP-AA, SBS-AA
(Optional) One or more BP-
AA, SBS-AA, SBS-TA or APP-
TA
SBS-AA, SBS-TA
or APP-TA -140.0
R-2. Existing asphaltic roof cover Min. 0.5-inch EnergyGuard Perlite Recover
Board Hot asphalt BP-AA, SBS-AA
(Optional) One or more BP-
AA, SBS-AA, SBS-TA or APP-
TA
SBS-AA, SBS-TA
or APP-TA -165.0
R-3. Existing asphaltic roof cover Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation Hot asphalt BP-AA, SBS-AA
(Optional) One or more BP-
AA, SBS-AA, SBS-TA or APP-
TA
SBS-AA, SBS-TA
or APP-TA -165.0
R-4. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard Composite Hot asphalt BP-AA, SBS-AA (Optional) One or more BP-
AA, SBS-AA
SBS-AA, SBS-TA
or APP-TA -240.0
R-5. Existing granule surface cap sheet Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board Hot asphalt SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -240.0
R-6. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation OB500 BP-AA, SBS-AA
(Optional) One or more BP-
AA, SBS-AA, SBS-TA or APP-
TA
SBS-AA, SBS-TA
or APP-TA -110.0
R-7. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board OB500 SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -110.0
R-8. Existing asphaltic roof cover Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation OB500 BP-AA, SBS-AA
(Optional) One or more BP-
AA, SBS-AA, SBS-TA or APP-
TA
SBS-AA, SBS-TA
or APP-TA -120.0
R-9. Existing asphaltic roof cover Min. 0.25-inch DensDeck Prime OB500 SBS-TA (Optional) One or more
SBS-TA SBS-TA -120.0
R-10. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
OB500, 6-
inch o.c. BP-AA, SBS-AA
(Optional) One or more BP-
AA, SBS-AA, SBS-TA or APP-
TA
SBS-AA, SBS-TA
or APP-TA -157.5
R-11. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
OB500, 6-
inch o.c. SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -157.5
R-12. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
OB500, 4-
inch o.c. BP-AA, SBS-AA
(Optional) One or more BP-
AA, SBS-AA, SBS-TA or APP-
TA
SBS-AA, SBS-TA
or APP-TA -165.0
R-13. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
OB500, 4-
inch o.c. SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -200.0
R-14. Existing granule surface cap sheet Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
OB500, 6-
inch o.c. SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -240.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 71 of 91
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY)
System
No.
Substrate
(Notes 1 & 12)
Base Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
R-15. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA
(Optional) One or more BP-
AA, SBS-AA, SBS-TA or APP-
TA
SBS-AA, SBS-TA
or APP-TA -110.0
R-16. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
GAF 2-Part,
6-inch o.c. BP-AA, SBS-AA
(Optional) One or more BP-
AA, SBS-AA, SBS-TA or APP-
TA
SBS-AA, SBS-TA
or APP-TA -157.5
R-17. Existing asphaltic roof cover Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA
(Optional) One or more BP-
AA, SBS-AA, SBS-TA or APP-
TA
SBS-AA, SBS-TA
or APP-TA -165.0
R-18. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.5-inch Structodek High Density
Fiberboard Roof Insulation
GAF 2-Part,
4-inch o.c. BP-AA, SBS-AA
(Optional) One or more BP-
AA, SBS-AA, SBS-TA or APP-
TA
SBS-AA, SBS-TA
or APP-TA -165.0
R-19. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board GAF 2-Part SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -110.0
R-20. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
GAF 2-Part,
6-inch o.c. SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -157.5
R-21. Existing asphaltic roof cover Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board GAF 2-Part SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -180.0
R-22. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
GAF 2-Part,
4-inch o.c. SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -180.0
R-23. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime GAF 2-Part,
4-inch o.c. SBS-TA (Optional) SBS-TA SBS-TA -200.0
R-24. Existing asphaltic roof cover Min. 0.25-inch DensDeck Prime GAF 2-Part SBS-TA (Optional) SBS-TA SBS-TA -245.0
SELF-ADHERING BASE PLY WITH BASE INSULATION LAYER ONLY
R-25. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard Ultra Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA
SBS-SA, SBS-TA,
APP-TA -90.0
R-26. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RN Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA SBS-TA, APP-TA -210.0
R-27. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA SBS-TA, APP-TA -217.5
R-28.
Existing smooth surfaced BUR / APP
modified bitumen or granule surface roof
cover over structural concrete deck
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
OB500 SBS-SA (Optional) SBS-TA or APP-
TA
SBS-TA or APP-
TA -97.5
R-29.
Existing asphaltic roof cover or gravel-
surfaced BUR, brushed/spudded and vacuumed
to remove loose gravel
Min 0.5-inch Structodek High Density
Fiberboard Roof Insulation
OB500, 6-
inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -110.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 72 of 91
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY)
System
No.
Substrate
(Notes 1 & 12)
Base Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
R-30. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 1.5-inch EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN OB500 SBS-SA (Optional) SBS-SA SBS-SA -110.0
R-31. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.25-inch DensDeck primed with Matrix
307 Premium Asphalt Primer or ASTM D41
primer
OB500 SBS-SA (Optional) SBS-TA or APP-
TA
SBS-TA or APP-
TA -110.0
R-32. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 1.5-inch EnergyGuard RN, Min. 0.5-inch
EnergyGuard Polyiso Insulation, EnergyGuard
Ultra or Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board
OB500 SBS-SA (Optional) SBS-TA or APP-
TA
SBS-TA or APP-
TA -110.0
R-33. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN OB500 SBS-SA (Optional) SBS-SA SBS-SA -120.0
R-34. Existing asphaltic roof cover
Min. 0.25-inch DensDeck, optionally primed
with Matrix 307 Premium Asphalt Primer or
ASTM D41 primer
OB500 SBS-SA (Optional) SBS-TA or APP-
TA
SBS-TA or APP-
TA -120.0
R-35. Existing asphaltic roof cover Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board OB500 SBS-SA (Optional) SBS-TA or APP-
TA
SBS-TA or APP-
TA -120.0
R-36. Existing asphaltic roof cover
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board primed with Matrix 307 Premium
Asphalt Primer or ASTM D41 primer
OB500 SBS-SA (Optional) SBS-TA or APP-
TA
SBS-TA or APP-
TA -120.0
R-37. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 1.5-inch EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN
OB500, 6-
inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -120.0
R-38. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel Min. 0.25-inch DensDeck OB500, 6-
inch o.c. SBS-SA (Optional) SBS-TA or APP-
TA
SBS-TA or APP-
TA -122.5
R-39. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
OB500, 6-
inch o.c. SBS-SA (Optional) SBS-TA or APP-
TA
SBS-TA or APP-
TA -137.5
R-40. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.25-inch DensDeck primed with Matrix
307 Premium Asphalt Primer or ASTM D41
primer
OB500, 6-
inch o.c. SBS-SA (Optional) SBS-TA or APP-
TA
SBS-TA or APP-
TA -157.5
R-41. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 1.5-inch EnergyGuard RN, Min. 0.5-inch
EnergyGuard Polyiso Insulation, EnergyGuard
Ultra or Min. 0.25-inch SECUROCK Gypsum-
Fiber Roof Board primed with Matrix 307
Premium Asphalt Primer or ASTM D41 primer
OB500, 6-
inch o.c. SBS-SA (Optional) SBS-TA or APP-
TA
SBS-TA or APP-
TA -157.5
R-42. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RN OB500, 4-
inch o.c. SBS-SA (Optional) SBS-TA or APP-
TA
SBS-TA or APP-
TA -162.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 73 of 91
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY)
System
No.
Substrate
(Notes 1 & 12)
Base Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
R-43. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.25-inch DensDeck primed with Matrix
307 Premium Asphalt Primer or ASTM D41
primer
OB500, 4-
inch o.c. SBS-SA (Optional) SBS-TA or APP-
TA
SBS-TA or APP-
TA -167.5
R-44. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra or Min. 0.25-inch
SECUROCK Gypsum-Fiber Roof Board primed
with Matrix 307 Premium Asphalt Primer or
ASTM D41 primer
OB500, 4-
inch o.c. SBS-SA (Optional) SBS-TA or APP-
TA
SBS-TA or APP-
TA -200.0
R-45. Existing smooth- or granule-surface BUR or
modified bitumen over concrete deck
Min. 0.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -225.0
R-46. Existing smooth-surface BUR over concrete
deck
Min. 0.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
LRF-M, M-
OSFA SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -75.0
R-47. Existing smooth surfaced BUR or granule
surface roof cover
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
LRF-M, M-
OSFA SBS-SA (Optional) SBS-TA or APP-
TA
SBS-TA or APP-
TA -75.0
R-48. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra LRF-M SBS-SA (Optional) SBS-TA or APP-
TA
SBS-TA or APP-
TA -110.0
R-49. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
LRF-M, 6-
inch o.c. SBS-SA (Optional) SBS-TA or APP-
TA
SBS-TA or APP-
TA -157.5
R-50. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
LRF-M, 4-
inch o.c. SBS-SA (Optional) SBS-TA or APP-
TA
SBS-TA or APP-
TA -200.0
R-51.
Existing granule-surface BUR or modified
bitumen or smooth-surface SBS modified
bitumen over concrete deck
Min. 0.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
LRF-M, M-
OSFA SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -225.0
R-52. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 1.5-inch EnergyGuard RA or EnergyGuard
RN GAF 2-Part SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA SBS-TA, APP-TA -110.0
R-53. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.25-inch DensDeck primed with Matrix
307 Premium Asphalt Primer or ASTM D41
primer
GAF 2-Part SBS-SA (Optional) SBS-TA or APP-
TA
SBS-TA or APP-
TA -110.0
R-54. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra or Min. 0.25-inch
SECUROCK Gypsum-Fiber Roof Board
GAF 2-Part SBS-SA (Optional) SBS-TA or APP-
TA
SBS-TA or APP-
TA -110.0
R-55. Existing asphaltic roof cover Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board GAF 2-Part SBS-SA (Optional) SBS-TA or APP-
TA
SBS-TA or APP-
TA -120.0
R-56. Existing asphaltic roof cover
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board primed with Matrix 307 Premium
Asphalt Primer or ASTM D41 primer
GAF 2-Part SBS-SA (Optional) SBS-TA or APP-
TA
SBS-TA or APP-
TA -120.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 74 of 91
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY)
System
No.
Substrate
(Notes 1 & 12)
Base Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
R-57. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
GAF 2-Part,
6-inch o.c. SBS-SA (Optional) SBS-TA or APP-
TA
SBS-TA or APP-
TA -137.5
R-58. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 1.5-inch EnergyGuard RA or EnergyGuard
RN
GAF 2-Part,
6-inch o.c. SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA SBS-TA, APP-TA -157.5
R-59. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.25-inch DensDeck primed with Matrix
307 Premium Asphalt Primer or ASTM D41
primer
GAF 2-Part,
6-inch o.c. SBS-SA (Optional) SBS-TA or APP-
TA
SBS-TA or APP-
TA -157.5
R-60. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra or Min. 0.25-inch
SECUROCK Gypsum-Fiber Roof Board primed
with Matrix 307 Premium Asphalt Primer or
ASTM D41 primer
GAF 2-Part,
6-inch o.c. SBS-SA (Optional) SBS-TA or APP-
TA
SBS-TA or APP-
TA -157.5
R-61. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.25-inch DensDeck primed with Matrix
307 Premium Asphalt Primer or ASTM D41
primer
GAF 2-Part,
4-inch o.c. SBS-SA (Optional) SBS-TA or APP-
TA
SBS-TA or APP-
TA -167.5
R-62. Existing smooth- or granule-surface BUR or
modified bitumen over concrete deck
Min. 0.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra GAF 2-Part SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -180.0
R-63. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra or Min. 0.25-inch
SECUROCK Gypsum-Fiber Roof Board primed
with Matrix 307 Premium Asphalt Primer or
ASTM D41 primer
GAF 2-Part,
4-inch o.c. SBS-SA (Optional) SBS-TA or APP-
TA
SBS-TA or APP-
TA -180.0
R-64. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 1.5-inch EnergyGuard RA or EnergyGuard
RN
GAF 2-Part,
4-inch o.c. SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA SBS-TA, APP-TA -200.0
R-65. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RN GAF 2-Part SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA SBS-TA, APP-TA -210.0
R-66. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA GAF 2-Part SBS-SA (Optional) SBS-SA, SBS-TA,
APP-TA SBS-TA, APP-TA -217.5
VENTING SYSTEMS WITH BASE INSULATION LAYER ONLY
R-67. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN Hot asphalt GAFGLAS Stratavent
Perforated Venting Base Sheet
(Optional) One or more BP-
AA, SBS-AA SBS-AA -150.0
R-68. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN Hot asphalt GAFGLAS Stratavent
Perforated Venting Base Sheet
One or more BP-AA, SBS-
AA
SBS-TA or APP-
TA -150.0
R-69.
Existing smooth- or granule-surface BUR,
granule-surface modified bitumen or
smooth-surface SBS modified bitumen over
concrete deck
Min. 0.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra Hot asphalt GAFGLAS Stratavent
Perforated Venting Base Sheet
(Optional) One or more BP-
AA, SBS-AA SBS-AA -150.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 75 of 91
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY)
System
No.
Substrate
(Notes 1 & 12)
Base Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
R-70. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard Ultra Hot asphalt GAFGLAS Stratavent
Perforated Venting Base Sheet
(Optional) One or more BP-
AA, SBS-AA SBS-AA -172.5
R-71. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard Ultra Hot asphalt GAFGLAS Stratavent
Perforated Venting Base Sheet
One or more BP-AA, SBS-
AA
SBS-TA or APP-
TA -172.5
R-72. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra OB500 GAFGLAS Stratavent
Perforated Venting Base Sheet
(Optional) One or more BP-
AA, SBS-AA SBS-AA -110.0
R-73. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
OB500, 6-
inch o.c.
GAFGLAS Stratavent
Perforated Venting Base Sheet
(Optional) One or more BP-
AA, SBS-AA SBS-AA -157.5
R-74. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
OB500, 4-
inch o.c.
GAFGLAS Stratavent
Perforated Venting Base Sheet
(Optional) One or more BP-
AA, SBS-AA SBS-AA -200.0
R-75. Existing smooth- or granule-surface BUR or
modified bitumen over concrete deck
Min. 0.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra OB500 GAFGLAS Stratavent
Perforated Venting Base Sheet
(Optional) One or more BP-
AA, SBS-AA SBS-AA -225.0
R-76. Existing smooth-surface BUR over concrete
deck
Min. 0.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
LRF-M, M-
OSFA
GAFGLAS Stratavent
Perforated Venting Base Sheet
(Optional) One or more BP-
AA, SBS-AA SBS-AA -75.0
R-77. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra LRF-M GAFGLAS Stratavent
Perforated Venting Base Sheet
(Optional) One or more BP-
AA, SBS-AA SBS-AA -110.0
R-78. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
LRF-M, 6-
inch o.c.
GAFGLAS Stratavent
Perforated Venting Base Sheet
(Optional) One or more BP-
AA, SBS-AA SBS-AA -157.5
R-79. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
LRF-M, 4-
inch o.c.
GAFGLAS Stratavent
Perforated Venting Base Sheet
(Optional) One or more BP-
AA, SBS-AA SBS-AA -200.0
R-80.
Existing granule-surface BUR or modified
bitumen or smooth-surface SBS modified
bitumen over concrete deck
Min. 0.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
LRF-M, M-
OSFA
GAFGLAS Stratavent
Perforated Venting Base Sheet
(Optional) One or more BP-
AA, SBS-AA SBS-AA -225.0
R-81. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra GAF 2-Part GAFGLAS Stratavent
Perforated Venting Base Sheet
(Optional) One or more BP-
AA, SBS-AA SBS-AA -110.0
R-82. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
GAF 2-Part,
6-inch o.c.
GAFGLAS Stratavent
Perforated Venting Base Sheet
(Optional) One or more BP-
AA, SBS-AA SBS-AA -157.5
R-83. Existing smooth- or granule-surface BUR or
modified bitumen over concrete deck
Min. 0.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra GAF 2-Part GAFGLAS Stratavent
Perforated Venting Base Sheet
(Optional) One or more BP-
AA, SBS-AA SBS-AA -180.0
R-84. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
GAF 2-Part,
4-inch o.c.
GAFGLAS Stratavent
Perforated Venting Base Sheet
(Optional) One or more BP-
AA, SBS-AA SBS-AA -200.0
COLD-APPLIED SYSTEMS WITH BASE INSULATION LAYER ONLY
R-85. Existing mineral surface cap or asphalt BUR Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board Hot asphalt SBS-CA1 None SBS-CA1 -127.5
R-86. Existing mineral surface cap Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board Hot asphalt SBS-CA1 None SBS-CA1 -172.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 76 of 91
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY)
System
No.
Substrate
(Notes 1 & 12)
Base Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
R-87.
Existing smooth APP, mineral surface cap,
asphaltic BUR or gravel-surfaced BUR,
brushed/spudded and vacuumed to remove
loose gravel
Min. 1.5-inch EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN OB500 SBS-CA1 None SBS-CA1 -60.0
R-88.
Existing smooth surfaced BUR / APP
modified bitumen, granule surface roof
cover or gravel-surfaced BUR,
brushed/spudded and vacuumed to remove
loose gravel over structural concrete deck
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
OB500 SBS-CA or SBS-CA1 None SBS-CA or SBS-
CA1 -97.5
R-89. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -110.0
R-90. Existing asphalt BUR Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -120.0
R-91. Existing smooth APP or mineral surface cap Min. 0.25-inch DensDeck Prime OB500 SBS-CA1 None SBS-CA1 -127.5
R-92. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime OB500, 6-
inch o.c. SBS-CA1 None SBS-CA1 -127.5
R-93. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
OB500, 6-
inch o.c. SBS-CA1 None SBS-CA1 -157.5
R-94. Existing smooth APP Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board OB500 SBS-CA1 None SBS-CA1 -165.0
R-95. Existing mineral surface cap Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board OB500 SBS-CA1 None SBS-CA1 -172.5
R-96. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
OB500, 4-
inch o.c. SBS-CA1 None SBS-CA1 -172.5
R-97. Existing smooth surfaced BUR or granule
surface roof cover
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
LRF-M, M-
OSFA SBS-CA or SBS-CA1 None SBS-CA or SBS-
CA1 -75.0
R-98. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board GAF 2-Part SBS-CA1 None SBS-CA1 -110.0
R-99. Existing asphalt BUR Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board GAF 2-Part SBS-CA1 None SBS-CA1 -120.0
R-100. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime GAF 2-Part,
6-inch o.c. SBS-CA1 None SBS-CA1 -127.5
R-101. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
GAF 2-Part,
6-inch o.c. SBS-CA1 None SBS-CA1 -157.5
R-102. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
GAF 2-Part,
4-inch o.c. SBS-CA1 None SBS-CA1 -172.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 77 of 91
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY)
System
No.
Substrate
(Notes 1 & 12)
Base Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
HYBRID HOT/COLD-APPLIED SYSTEMS WITH BASE INSULATION LAYER ONLY
R-103. Existing mineral surface cap or asphalt BUR Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5
R-104. Existing mineral surface cap Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5
R-105. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -110.0
R-106. Existing asphalt BUR Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -120.0
R-107. Existing smooth APP or mineral surface cap Min. 0.25-inch DensDeck Prime OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5
R-108. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime OB500, 6-
inch o.c. BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5
R-109. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
OB500, 6-
inch o.c. BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -157.5
R-110. Existing smooth APP Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -165.0
R-111. Existing mineral surface cap Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5
R-112. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
OB500, 4-
inch o.c. BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5
R-113. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board GAF 2-Part BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -110.0
R-114. Existing asphalt BUR Min. 0.25-inch DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board GAF 2-Part BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -120.0
R-115. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime GAF 2-Part,
6-inch o.c. BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5
R-116. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
GAF 2-Part,
6-inch o.c. BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -157.5
R-117. Existing gravel-surfaced BUR, brushed/spudded
and vacuumed to remove loose gravel
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
GAF 2-Part,
4-inch o.c. BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 78 of 91
TABLE 7B: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION)
Sys
No.
Substrate
(Notes 1 & 12)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
CONVENTIONAL SYSTEMS (BASE AND TOP LAYER INSULATION):
R-118. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN Hot asphalt
Min. 0.25-inch DensDeck,
DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
Hot asphalt BP-AA (Optional) BP-AA
SBS-AA
or SBS-
TA
-112.5
R-119. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN Hot asphalt
Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof
Board
Hot asphalt SBS-TA, APP-TA (Optional) SBS-
TA, APP-TA
SBS-TA,
APP-TA -127.5
R-120.
Existing smooth- or granule-
surface BUR, granule-surface
modified bitumen or smooth-
surface SBS modified bitumen
over concrete deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra Hot asphalt
Min. 0.5-inch Structodek High
Density Fiberboard Roof
Insulation, EnergyGuard Perlite
Recover Board, min. 0.75-inch
EnergyGuard Perlite Roof
Insulation, min. 0.25-inch
DensDeck, DensDeck Prime,
SECUROCK Gypsum Fiber Roof
Board
Hot asphalt BP-AA, SBS-AA (Optional) BP-
AA, SBS-AA SBS-AA -150.0
R-121. Existing granule surface cap
sheet
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN Hot asphalt
Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof
Board
Hot asphalt SBS-TA, APP-TA (Optional) SBS-
TA, APP-TA
SBS-TA,
APP-TA -172.5
R-122. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN Hot asphalt
Min. 0.75-inch EnergyGuard
Perlite Roof Insulation
(homogeneous)
Hot asphalt BP-AA, SBS-AA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-172.5
R-123. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.5-inch EnergyGuard Perlite
Recover Board Hot asphalt BP-AA, SBS-AA
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA -187.5
R-124. Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
Hot asphalt Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-225.0
R-125. Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
Hot asphalt
Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof
Board
Hot asphalt SBS-TA (Optional) SBS-
TA SBS-TA -232.5
R-126. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board Hot asphalt APP-TA (Optional) APP-
TA APP-TA -240.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 79 of 91
TABLE 7B: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION)
Sys
No.
Substrate
(Notes 1 & 12)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
R-127. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN Hot asphalt
Min. 0.5-inch Structodek High
Density Fiberboard Roof Insulation
or Min. 1.5-inch EnergyGuard
Composite or min. 0.25-inch
DensDeck Prime
Hot asphalt BP-AA, SBS-AA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-240.0
R-128.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500 Min. 0.5-inch Structodek High
Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-110.0
R-129.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500
Min. 0.25-inch DensDeck,
DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
OB500 BP-AA, SBS-AA, SBS-
TA or APP-TA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-110.0
R-130. Existing asphalt BUR or mineral
surface cap
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN OB500
Min. 0.25-inch DensDeck,
DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
OB500 BP-AA, SBS-AA, SBS-
TA or APP-TA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-120.0
R-131. Existing asphalt BUR or mineral
surface cap
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN OB500 Min. 0.5-inch Structodek High
Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-120.0
R-132. Existing smooth APP Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck or
DensDeck Prime OB500 BP-AA, SBS-AA, SBS-
TA or APP-TA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-150.0
R-133.
Existing smooth- or granule-
surface BUR or modified
bitumen over concrete deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra OB500
Min. 0.5-inch Structodek High
Density Fiberboard Roof
Insulation, min. 0.25-inch
DensDeck, DensDeck Prime,
SECUROCK Gypsum Fiber Roof
Board
OB500 BP-AA, SBS-AA (Optional) BP-
AA, SBS-AA SBS-AA -150.0
R-134.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500, 6-
inch o.c.
Min. 0.25-inch DensDeck or
DensDeck Prime OB500 BP-AA, SBS-AA, SBS-
TA or APP-TA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-150.0
R-135.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500, 6-
inch o.c.
Min. 0.5-inch Structodek High
Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-157.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 80 of 91
TABLE 7B: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION)
Sys
No.
Substrate
(Notes 1 & 12)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
R-136.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500, 6-
inch o.c.
Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof
Board
OB500 SBS-TA, APP-TA (Optional) SBS-
TA, APP-TA
SBS-TA,
APP-TA -157.5
R-137.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500, 6-
inch o.c.
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-157.5
R-138. Existing smooth APP Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN OB500
Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof
Board
OB500 BP-AA, SBS-AA, SBS-
TA or APP-TA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-165.0
R-139. Existing smooth APP Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN OB500 Min. 0.5-inch Structodek High
Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-165.0
R-140.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500, 4-
inch o.c.
Min. 0.5-inch Structodek High
Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-165.0
R-141.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500, 4-
inch o.c.
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-187.5
R-142.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500, 4-
inch o.c. Min. 0.25-inch DensDeck Prime OB500 SBS-TA (Optional) SBS-
TA SBS-TA -200.0
R-143.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500, 4-
inch o.c.
Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof
Board
OB500 SBS-TA, APP-TA (Optional) SBS-
TA, APP-TA
SBS-TA,
APP-TA -200.0
R-144.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500, 4-
inch o.c.
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-200.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 81 of 91
TABLE 7B: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION)
Sys
No.
Substrate
(Notes 1 & 12)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
R-145. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA or
EnergyGuard RN
OB500, 6-
inch o.c.
Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof
Board
OB500, 6-
inch o.c.
BP-AA, SBS-AA, SBS-
TA or APP-TA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-240.0
R-146. Existing smooth-surface BUR
over concrete deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M, M-
OSFA
Min. 0.5-inch Structodek High
Density Fiberboard Roof
Insulation, min. 0.25-inch
DensDeck, DensDeck Prime,
SECUROCK Gypsum Fiber Roof
Board
LRF-M, M-
OSFA BP-AA, SBS-AA (Optional) BP-
AA, SBS-AA SBS-AA -75.0
R-147.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra LRF-M
Min. 0.5-inch Structodek High
Density Fiberboard Roof
Insulation, min. 0.25-inch
DensDeck, DensDeck Prime,
SECUROCK Gypsum Fiber Roof
Board
LRF-M BP-AA, SBS-AA (Optional) BP-
AA, SBS-AA SBS-AA -110.0
R-148.
Existing granule-surface BUR
or modified bitumen or
smooth-surface SBS modified
bitumen over concrete deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M, M-
OSFA
Min. 0.5-inch Structodek High
Density Fiberboard Roof
Insulation, min. 0.25-inch
DensDeck, DensDeck Prime,
SECUROCK Gypsum Fiber Roof
Board
LRF-M, M-
OSFA BP-AA, SBS-AA (Optional) BP-
AA, SBS-AA SBS-AA -150.0
R-149.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M, 6-
inch o.c.
Min. 0.5-inch Structodek High
Density Fiberboard Roof
Insulation, min. 0.25-inch
DensDeck, DensDeck Prime,
SECUROCK Gypsum Fiber Roof
Board
LRF-M BP-AA, SBS-AA (Optional) BP-
AA, SBS-AA SBS-AA -150.0
R-150.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
GAF 2-Part Min. 0.5-inch Structodek High
Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-110.0
R-151.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
GAF 2-Part
Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof
Board
GAF 2-Part BP-AA, SBS-AA, SBS-
TA or APP-TA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-110.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 82 of 91
TABLE 7B: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION)
Sys
No.
Substrate
(Notes 1 & 12)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
R-152.
Existing smooth- or granule-
surface BUR or modified
bitumen over concrete deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra GAF 2-Part
Min. 0.5-inch Structodek High
Density Fiberboard Roof
Insulation, min. 0.25-inch
DensDeck, DensDeck Prime,
SECUROCK Gypsum Fiber Roof
Board
GAF 2-Part BP-AA, SBS-AA (Optional) BP-
AA, SBS-AA SBS-AA -150.0
R-153.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
GAF 2-Part,
6-inch o.c.
Min. 0.5-inch Structodek High
Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-157.5
R-154.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
GAF 2-Part,
6-inch o.c.
Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof
Board
GAF 2-Part BP-AA, SBS-AA, SBS-
TA or APP-TA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-157.5
R-155. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.5-inch Structodek High
Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-180.0
R-156.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
GAF 2-Part,
4-inch o.c.
Min. 0.5-inch Structodek High
Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-180.0
R-157.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
GAF 2-Part,
4-inch o.c.
Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof
Board
GAF 2-Part BP-AA, SBS-AA, SBS-
TA or APP-TA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-180.0
R-158.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation
GAF 2-Part,
4-inch o.c.
Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof
Board
GAF 2-Part BP-AA, SBS-AA, SBS-
TA or APP-TA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-200.0
R-159. Existing asphaltic roof cover
Min. 2.0-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2-Part Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board GAF 2-Part BP-AA or SBS-AA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-225.0
R-160. Existing asphaltic roof cover
Min. 2.0-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2-Part Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board GAF 2-Part SBS-TA or APP-TA
(Optional) BP-
AA, SBS-AA, SBS-
TA or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-232.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 83 of 91
TABLE 7B: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION)
Sys
No.
Substrate
(Notes 1 & 12)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
R-161. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.25-inch DensDeck or
DensDeck Prime GAF 2-Part BP-AA, SBS-AA, SBS-
TA or APP-TA
(Optional) One
or more BP-AA,
SBS-AA, SBS-TA
or APP-TA
SBS-AA,
SBS-TA
or APP-
TA
-240.0
SELF-ADHERING BASE PLY WITH POLYISOCYANURATE BASE INSULATION LAYER
R-162.
Existing smooth surfaced BUR
/ APP modified bitumen or
granule surface roof cover
over structural concrete deck
Min. 1.5-inch EnergyGuard RH OB500
Min. 0.5-inch EnergyGuard RH HD
Polyiso Insulation, EnergyGuard
HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso
Insulation
OB500 SBS-SA (Optional) SBS-
TA or APP-TA
SBS-TA
or APP-
TA
-97.5
R-163.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH OB500
Min. 0.5-inch EnergyGuard HD
Polyiso Insulation, EnergyGuard
HD Plus Polyiso Insulation
OB500 SBS-SA (Optional) SBS-
TA or APP-TA
SBS-TA
or APP-
TA
-97.5
R-164.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra OB500 (Optional) Additional layer(s) base
insulation OB500 SBS-SA (Optional) SBS-
TA, APP-TA
SBS-TA,
APP-TA -110.0
R-165.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN,
EnergyGuard Ultra
OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-SA (Optional) SBS-
SA SBS-SA -110.0
R-166.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN,
EnergyGuard Ultra
OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-
TA, APP-TA
SBS-TA,
APP-TA -110.0
R-167. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN OB500
Min. 0.25-inch DensDeck,
DensDeck Prime or SECUROCK
Gypsum-Fiber Roof Board
OB500 SBS-SA (Optional) SBS-
SA
SBS-TA
or APP-
TA
-120.0
R-168.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RN
OB500, 6-
inch o.c.
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-
TA, APP-TA
SBS-TA,
APP-TA -120.0
R-169. Existing smooth APP Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-SA (Optional) SBS-
SA SBS-SA -152.5
R-170.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500, 6-
inch o.c. Min. 0.25-inch DensDeck Prime OB500 SBS-SA (Optional) SBS-
SA SBS-SA -152.5
R-171.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
OB500, 6-
inch o.c.
(Optional) Additional layer(s) base
insulation OB500 SBS-SA (Optional) SBS-
TA, APP-TA
SBS-TA,
APP-TA -157.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 84 of 91
TABLE 7B: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION)
Sys
No.
Substrate
(Notes 1 & 12)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
R-172.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500, 6-
inch o.c.
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-
TA, APP-TA
SBS-TA,
APP-TA -157.5
R-173. Existing smooth APP Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN OB500
Min. 0.25-inch DensDeck; surface
shall be primed with Matrix 307
Premium Asphalt Primer or ASTM
D41 primer
OB500 SBS-SA (Optional) SBS-
TA, APP-TA
SBS-TA,
APP-TA -165.0
R-174.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500, 4-
inch o.c.
Min. 0.25-inch DensDeck; surface
shall be primed with Matrix 307
Premium Asphalt Primer or ASTM
D41 primer
OB500 SBS-SA (Optional) SBS-
TA, APP-TA
SBS-TA,
APP-TA -167.5
R-175.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
OB500, 4-
inch o.c.
(Optional) Additional layer(s) base
insulation OB500 SBS-SA (Optional) SBS-
TA, APP-TA
SBS-TA,
APP-TA -200.0
R-176.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500, 4-
inch o.c.
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-
TA, APP-TA
SBS-TA,
APP-TA -200.0
R-177.
Existing smooth- or granule-
surface BUR or modified
bitumen over concrete deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra OB500 Min. 0.25-inch SECUROCK Gypsum
Fiber Roof Board OB500 SBS-SA (Optional) SBS-
TA or APP-TA
SBS-TA
or APP-
TA
-225.0
R-178. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA or
EnergyGuard RN
OB500, 6-
inch o.c.
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board (primer
optional)
OB500, 6-
inch o.c. SBS-SA (Optional) SBS-
TA, APP-TA
SBS-TA,
APP-TA -240.0
R-179. Existing smooth-surface BUR
over concrete deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M, M-
OSFA
Min. 0.25-inch SECUROCK Gypsum
Fiber Roof Board
LRF-M, M-
OSFA SBS-SA (Optional) SBS-
TA or APP-TA
SBS-TA
or APP-
TA
-75.0
R-180. Existing smooth surfaced BUR
or granule surface roof cover Min. 1.5-inch EnergyGuard RH LRF-M, M-
OSFA
Min. 0.5-inch EnergyGuard RH HD
Polyiso Insulation, EnergyGuard
HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso
Insulation
LRF-M, M-
OSFA SBS-SA (Optional) SBS-
TA or APP-TA
SBS-TA
or APP-
TA
-75.0
R-181.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH LRF-M
Min. 0.5-inch EnergyGuard HD
Polyiso Insulation, EnergyGuard
HD Plus Polyiso Insulation
LRF-M SBS-SA (Optional) SBS-
TA or APP-TA
SBS-TA
or APP-
TA
-97.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 85 of 91
TABLE 7B: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION)
Sys
No.
Substrate
(Notes 1 & 12)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
R-182.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra LRF-M
(Optional) Additional layer(s) base
insulation and/or Min. 0.25-inch
SECUROCK Gypsum-Fiber Roof
Board
LRF-M SBS-SA (Optional) SBS-
TA, APP-TA
SBS-TA,
APP-TA -110.0
R-183.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M, 6-
inch o.c.
(Optional) Additional layer(s) base
insulation and/or Min. 0.25-inch
SECUROCK Gypsum-Fiber Roof
Board
LRF-M SBS-SA (Optional) SBS-
TA, APP-TA
SBS-TA,
APP-TA -157.5
R-184.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M, 4-
inch o.c.
(Optional) Additional layer(s) base
insulation and/or Min. 0.25-inch
SECUROCK Gypsum-Fiber Roof
Board
LRF-M SBS-SA (Optional) SBS-
TA, APP-TA
SBS-TA,
APP-TA -200.0
R-185.
Existing granule-surface BUR
or modified bitumen or
smooth-surface SBS modified
bitumen over concrete deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M, M-
OSFA
Min. 0.25-inch SECUROCK Gypsum
Fiber Roof Board
LRF-M, M-
OSFA SBS-SA (Optional) SBS-
TA or APP-TA
SBS-TA
or APP-
TA
-225.0
R-186.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra GAF 2-Part
(Optional) Additional layer(s) base
insulation and/or Min. 0.25-inch
SECUROCK Gypsum-Fiber Roof
Board
GAF 2-Part SBS-SA (Optional) SBS-
TA, APP-TA
SBS-TA,
APP-TA -110.0
R-187.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part SBS-SA (Optional) SBS-
SA SBS-SA -110.0
R-188.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
GAF 2-Part,
6-inch o.c. Min. 0.25-inch DensDeck Prime GAF 2-Part SBS-SA (Optional) SBS-
SA SBS-SA -152.5
R-189.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
GAF 2-Part,
6-inch o.c.
(Optional) Additional layer(s) base
insulation and/or Min. 0.25-inch
SECUROCK Gypsum-Fiber Roof
Board
GAF 2-Part SBS-SA (Optional) SBS-
TA, APP-TA
SBS-TA,
APP-TA -157.5
R-190.
Existing smooth- or granule-
surface BUR or modified
bitumen over concrete deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra GAF 2-Part Min. 0.25-inch SECUROCK Gypsum
Fiber Roof Board GAF 2-Part SBS-SA (Optional) SBS-
TA or APP-TA
SBS-TA
or APP-
TA
-180.0
R-191.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
GAF 2-Part,
4-inch o.c.
(Optional) Additional layer(s) base
insulation GAF 2-Part SBS-SA (Optional) SBS-
TA, APP-TA
SBS-TA,
APP-TA -180.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 86 of 91
TABLE 7B: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION)
Sys
No.
Substrate
(Notes 1 & 12)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
R-192.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
GAF 2-Part,
4-inch o.c.
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board GAF 2-Part SBS-SA (Optional) SBS-
TA, APP-TA
SBS-TA,
APP-TA -180.0
VENTING SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER:
R-193. Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
Hot asphalt
Min. 0.75-inch EnergyGuard
Perlite Roof Insulation
(homogeneous)
Hot asphalt
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA -90.0
R-194. Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
Hot asphalt
Min. 0.75-inch EnergyGuard
Perlite Roof Insulation
(homogeneous)
Hot asphalt
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA
or APP-
TA
-90.0
R-195. Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
Hot asphalt Min. 0.5-inch Structodek High
Density Fiberboard Roof Insulation Hot asphalt
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA -90.0
R-196. Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
Hot asphalt Min. 0.5-inch Structodek High
Density Fiberboard Roof Insulation Hot asphalt
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA
or APP-
TA
-90.0
R-197. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN Hot asphalt (Optional) EnergyGuard Hot asphalt
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA -150.0
R-198. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN Hot asphalt (Optional) EnergyGuard Hot asphalt
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA
or APP-
TA
-150.0
R-199. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard Ultra Hot asphalt (Optional) EnergyGuard Ultra Hot asphalt
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA -172.5
R-200. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard Ultra Hot asphalt (Optional) EnergyGuard Ultra Hot asphalt
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA
or APP-
TA
-172.5
R-201. Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
Hot asphalt Min. 0.25-inch DensDeck or
DensDeck Prime Hot asphalt
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA -240.0
R-202. Existing asphaltic roof cover
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
Hot asphalt Min. 0.25-inch DensDeck or
DensDeck Prime Hot asphalt
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA
or APP-
TA
-240.0
R-203.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500 Min. 0.5-inch Structodek High
Density Fiberboard Roof Insulation OB500
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA -90.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 87 of 91
TABLE 7B: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION)
Sys
No.
Substrate
(Notes 1 & 12)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
R-204.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500 Min. 0.5-inch Structodek High
Density Fiberboard Roof Insulation OB500
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA
or APP-
TA
-90.0
R-205.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Ultra OB500 (Optional) EnergyGuard Ultra OB500
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA -110.0
R-206.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Ultra OB500 (Optional) EnergyGuard Ultra OB500
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA
or APP-
TA
-110.0
R-207.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500 Min. 0.25-inch DensDeck or
DensDeck Prime OB500
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA -110.0
R-208.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500 Min. 0.25-inch DensDeck or
DensDeck Prime OB500
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA
or APP-
TA
-110.0
R-209.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Ultra OB500, 6-
inch o.c. (Optional) EnergyGuard Ultra OB500
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA -150.0
R-210.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Ultra OB500, 6-
inch o.c. (Optional) EnergyGuard Ultra OB500
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA
or APP-
TA
-150.0
R-211.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500, 6-
inch o.c.
Min. 0.25-inch DensDeck or
DensDeck Prime OB500
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA -150.0
R-212.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
OB500, 6-
inch o.c.
Min. 0.25-inch DensDeck or
DensDeck Prime OB500
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA
or APP-
TA
-150.0
R-213.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2-Part Min. 0.5-inch Structodek High
Density Fiberboard Roof Insulation GAF 2-Part
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA -90.0
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 88 of 91
TABLE 7B: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION)
Sys
No.
Substrate
(Notes 1 & 12)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
R-214.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2-Part Min. 0.5-inch Structodek High
Density Fiberboard Roof Insulation GAF 2-Part
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA
or APP-
TA
-90.0
R-215.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Ultra GAF 2-Part (Optional) EnergyGuard Ultra GAF 2-Part
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA -110.0
R-216.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Ultra GAF 2-Part (Optional) EnergyGuard Ultra GAF 2-Part
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA
or APP-
TA
-110.0
R-217.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA -110.0
R-218.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA
or APP-
TA
-110.0
R-219.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Ultra GAF 2-Part,
6-inch o.c. (Optional) EnergyGuard Ultra GAF 2-Part
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA -157.5
R-220.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Ultra GAF 2-Part,
6-inch o.c. (Optional) EnergyGuard Ultra GAF 2-Part
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA
or APP-
TA
-157.5
R-221.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2-Part,
6-inch o.c. Min. 0.25-inch DensDeck Prime GAF 2-Part
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA -157.5
R-222.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2-Part,
6-inch o.c. Min. 0.25-inch DensDeck Prime GAF 2-Part
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA
or APP-
TA
-157.5
R-223.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Ultra GAF 2-Part,
4-inch o.c. (Optional) EnergyGuard Ultra GAF 2-Part
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA -172.5
R-224.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Ultra GAF 2-Part,
4-inch o.c. (Optional) EnergyGuard Ultra GAF 2-Part
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA
or APP-
TA
-172.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 89 of 91
TABLE 7B: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION)
Sys
No.
Substrate
(Notes 1 & 12)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
R-225.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part
GAFGLAS Stratavent
Perforated Venting
Base Sheet
(Optional) One
or more BP-AA,
SBS-AA
SBS-AA -200.0
R-226.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN or
EnergyGuard Ultra
GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part
GAFGLAS Stratavent
Perforated Venting
Base Sheet
One or more BP-
AA, SBS-AA
SBS-TA
or APP-
TA
-200.0
COLD-APPLIED SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER:
R-227. Existing asphalt BUR Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN Hot asphalt
Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof
Board
Hot asphalt SBS-CA1 None SBS-CA1 -120.0
R-228. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN Hot asphalt
Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof
Board
Hot asphalt SBS-CA1 None SBS-CA1 -127.5
R-229.
Existing asphaltic roof cover or
gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500 Min. 0.5-inch Structodek High
Density Fiberboard Roof Insulation OB500 SBS-CA None SBS-CA -45.0
R-230.
Existing smooth surfaced BUR
/ APP modified bitumen,
granule surface roof cover or
gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel over
structural concrete deck
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH OB500
Min. 0.5-inch EnergyGuard RH HD
Polyiso Insulation, EnergyGuard
HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso
Insulation
OB500 SBS-CA or SBS-CA1 None
SBS-CA
or SBS-
CA1
-97.5
R-231.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof
Board
OB500 SBS-CA1 None SBS-CA1 -110.0
R-232. Existing asphalt BUR Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN OB500
Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof
Board
OB500 SBS-CA1 None SBS-CA1 -120.0
R-233. Existing smooth APP or mineral
surface cap
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-CA1 None SBS-CA1 -127.5
R-234.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500, 6-
inch o.c. Min. 0.25-inch DensDeck Prime OB500 SBS-CA1 None SBS-CA1 -127.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 90 of 91
TABLE 7B: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION)
Sys
No.
Substrate
(Notes 1 & 12)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
R-235.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500, 6-
inch o.c.
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -157.5
R-236. Existing smooth APP Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -165.0
R-237. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -172.5
R-238.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500, 4-
inch o.c.
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -172.5
R-239. Existing smooth surfaced BUR
or granule surface roof cover Min. 1.5-inch EnergyGuard RH LRF-M, M-
OSFA
Min. 0.5-inch EnergyGuard RH HD
Polyiso Insulation, EnergyGuard
HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso
Insulation
LRF-M, M-
OSFA SBS-CA or SBS-CA1 None
SBS-CA
or SBS-
CA1
-75.0
R-240.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
LRF-M
Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof
Board
LRF-M SBS-CA1 None SBS-CA1 -110.0
R-241.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
LRF-M, 6-
inch o.c. Min. 0.25-inch DensDeck Prime LRF-M SBS-CA1 None SBS-CA1 -127.5
R-242.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
LRF-M, 6-
inch o.c.
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board LRF-M SBS-CA1 None SBS-CA1 -157.5
R-243.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
LRF-M, 4-
inch o.c.
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board LRF-M SBS-CA1 None SBS-CA1 -172.5
R-244.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
GAF 2-Part
Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof
Board
GAF 2-Part SBS-CA1 None SBS-CA1 -110.0
R-245.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
GAF 2-Part,
6-inch o.c. Min. 0.25-inch DensDeck Prime GAF 2-Part SBS-CA1 None SBS-CA1 -127.5
R-246.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
GAF 2-Part,
6-inch o.c.
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board GAF 2-Part SBS-CA1 None SBS-CA1 -157.5
NEMO|etc.
NEMO ETC, LLC Evaluation Report 01506.11.04-R29 for FL5680-R29
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 29: 10/11/2020
©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 91 of 91
TABLE 7B: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION)
Sys
No.
Substrate
(Notes 1 & 12)
Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP
(psf) Type Attach
(Notes 6,7,8) Type Attach
(Notes 6,7,8) Base Ply Ply Cap Ply
R-247.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
GAF 2-Part,
4-inch o.c.
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board GAF 2-Part SBS-CA1 None SBS-CA1 -172.5
HYBRID HOT/COLD-APPLIED SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER:
R-248. Existing asphalt BUR Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN Hot asphalt
Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof
Board
Hot asphalt BP-AA or SBS-AA (Optional) BP-AA
or SBS-AA SBS-CA1 -120.0
R-249. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN Hot asphalt
Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof
Board
Hot asphalt BP-AA or SBS-AA (Optional) BP-AA
or SBS-AA SBS-CA1 -127.5
R-250. Existing asphalt BUR Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN OB500
Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof
Board
OB500 BP-AA or SBS-AA (Optional) BP-AA
or SBS-AA SBS-CA1 -120.0
R-251. Existing smooth APP or mineral
surface cap
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime OB500 BP-AA or SBS-AA (Optional) BP-AA
or SBS-AA SBS-CA1 -127.5
R-252. Existing smooth APP Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA
or SBS-AA SBS-CA1 -165.0
R-253. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA
or SBS-AA SBS-CA1 -172.5
R-254.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500,
LRF-M or
GAF 2-Part
Min. 0.25-inch DensDeck Prime or
SECUROCK Gypsum-Fiber Roof
Board
OB500,
LRF-M or
GAF 2-Part
BP-AA or SBS-AA (Optional) BP-AA
or SBS-AA SBS-CA1 -110.0
R-255.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500,
LRF-M or
GAF 2-Part,
6-inch o.c.
Min. 0.25-inch DensDeck Prime
OB500,
LRF-M or
GAF 2-Part
BP-AA or SBS-AA (Optional) BP-AA
or SBS-AA SBS-CA1 -127.5
R-256.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500,
LRF-M or
GAF 2-Part,
6-inch o.c.
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
OB500,
LRF-M or
GAF 2-Part
BP-AA or SBS-AA (Optional) BP-AA
or SBS-AA SBS-CA1 -157.5
R-257.
Existing gravel-surfaced BUR,
brushed/spudded and vacuumed
to remove loose gravel
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500,
LRF-M or
GAF 2-Part,
4-inch o.c.
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
OB500,
LRF-M or
GAF 2-Part
BP-AA or SBS-AA (Optional) BP-AA