Loading...
HomeMy WebLinkAboutAPPROVED, OC DURATION ver 2020Regulation ACTS Home Log In User Registration HotToplts Submit Surcharge Stats & Facts Publications contact Us BCIs Site Map Links Search F�rida prProduct Approval USER: public User Euiguct ARDmyjfl MenL] 7 PEPOW or Agpfjr_at€On Search 7 AAppiication L st 7 Application Getaii FL # FL10674-R16 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Owens Coming Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 g reg. keeler@owenscorning.com Authorized Signature Greg Keeler greg. keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Emall 1 Owens Corning PKWY Toledo, OH 43659 (419) 376-8360 me I - sa n cra nt@ owe n sco rn I g . cam Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcapy Received Fiorlda Engineer or Architect Name who developed the Robert J.M. Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 01/01/2099 Validated By John W. Knexevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FFLIQ674R1.6 COI 7020 01 COI NIEMINEN.pd Referenced Standard and Year {of Standard} Standard Year ASTM D1970 2015 ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2019 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 12/11/2020 Date Validated 12/17/2020 Date Pending FBC Approval 12/26/2020 Date Approved 02/09/2021 summary of Products FL .# Model, Number or Name Description 10674.1 Owens Coming Asphalt Roofing Shingles and Starters 3-tab, 4-tab, laminated, starter and hip & ridge shingles Limits of Use Installation Instructions Approved for use in HVHZ: Na Approved for use outside HVHZ: Yes Impact Resistant: N/A FL10674 R16 11 020 12 1 Al ER nr ACDHALT SHINGLES FL1Qfj74-R16.pd Verified By: Robert J. M. Nieminen PE - 59166 Design Pressure: N/A Other: Refer to ER, Section 5. Created by Independent Third Party: Yes Evaluation Reports FLQ674 R15_AE 2020 12 11 FINAIER OC ASPHALT SHINGLES_ FL10674-R15.ndf Created by Independent Third Party: Yes back Hex] Contact Us :: 1601 51air Stone Road, Tallahassee FL 32399 Phone: 854-487-1824 The State of Florlda Is an ANEW employer. Copyright 2007-2013 State of Florlda, :: Privacy Statement :: Accessibili Statement :: Refund statement Under Florlda law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. if you have any questions, please contact 850.487.139S. *Pursuant to Section 455.275(1), Florlda Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click h r Product Approval Accepts - Credit Card Safe MEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION•O• Owens Corning Evaivation Report 037940.02.12-1111 One Owens Corning Parkway FL10674-Ri6 Toledo, OH 43659 (740)404-7829 Date of Issuance: 02/06/2012 Revision 11. 12/11/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 71h Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt hoof Shingles LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1 / R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEW ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO I etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10. Prepared by: "s K r.'T'= The facsimile seal appearingwas authorized by Robert Robert J.M. Nieminen, P.E. . �.t � : '•_- ��•.FS '••-••;'c' Nieminen, P.E. on 12/11/2020. This does not serve as an Florida Registration No. 59166, Florida OCA ANE1983 ✓ .; = "` r•'' �• <<< eIectronIca Ilysigned document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E, are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 9)2018 N EMO ETC, LLC ONEMOletc. ROOFING SYSTEMS EVALUATION: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Proa Standard Year 1507.2.4, R905.2.3 Physical Properties ASTM D1970 2015 1507.2.S, R905.2.4 Material standard ASTM D3462 2010 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, R905,2,6.1 Wind Resistance ASTM D7158 2019 3. REFERENCES: Entity Examination Reference Date Owens Corning Declaration Equivalency Declaration 08/06/2019 PRI (TST5878) ASTM D1970 OCF-382-02-01 10/24/2017 UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL LLC (CER9626) Physicals & Wind Resistance 20120516-112453 05/16/2012 UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014 UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC (TST9628) Physical Properties Classification letter 02/13/2014 UL LLC (TST9628) Physical Properties Classification letter 10/02/2015 PRI (QUA9110) quality Control Service Confirmation 04/05/2020 PRI (QUA9110) Quality Control Florida BCIS Current PRODUCT4. r ■ TABLE 1: ASPHALT SHINGLE COMPONENTS Type Product Plants { I Material Description Standard Starter Strip Shin le H-TX, OR Starter Strip Plus MN, OR Accessory ASTM D3462 starter strips for asphalt roof shingles SRS TopShield Starter MN, OR Starter Strips Starter Shingle Roll NH ASTM D1970 mineral-surfaced,fiberglass-reinforced, self -adhering SBS modified bitumen starter Supreme* GA, CA, CO, I -TX, NJ, OH, ASTM D3462 fiberglass reinforced 3-tab asp ha it TN, OR, IL roof shingles Berkshire MN ASTM D3462 fiberglass reinforced, 4-tab asphalt roof shingles Duration Premium CA, OR Duration Premium COOL CA Asphalt TruDefinition' Duration Shingles IN CA, CO, I -TX, FL, NJ, OH, TruDefinition' Duration Designer Color Collection MN, OR, GA, IL, TN ASTM D3462 fiberglass reinforced, laminated asphalt roof shingles Oakridge' GA, IN, CA, CO, H-TX, I -TX, FL, NJ OH, TN TruDefinition0akridge H-TX, I -TX WeatherGuard* HP TN NEMQ ETC, LLC Evaluation Report 037440.02.12-1111 CerrUkateofAutharization #32455 7`" EDITION (2020) FBC NON-HV142 EVALUATION FL10574-R16 Owens Coming Asphalt Roof Shingles Revision 11:12/11/2020 Page 2 of 10 ONEMOjetc. TABLE 1: ASPHALT SHINGLE COMPONENTS TypeT Product Plant(s) Material Description standard Berkshire' Hip and Ridge MN Shingles with Sealant Hip and DuraRidgee Hip and Ridge MN M D3462 fiberglass reinforced, hip and ridge Ridge Shingles with Sealant AST Shingles ProEdge* GA, CA, OH, OR asphalt roof shingles WeatherGuard' HP Hip and TN Ridge Shingles 5- Limiwioims: 5.1 This is a building code evaluation. Neither NEMQ ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami- ❑ade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to F8C 2603 for requirements and limitations concerning the use of foam plastic insulation. 5_5 Wind Classification: Refer to Section 6 for installation requirements to meet wind classifications TABLE 2A: WIND CLASSIFICATIONS, ASPHALT SHINGLES Product FBC Table 1507.2.7.1 or 11905.16.1 Supreme' ASTM D3161(F) & ASTM D7158(H) Berkshire' Duration' Premium Duration' Premium COOL TruDefinition' Duration' TruDefinition' Duration Designer Color Collection Oakridge TruDefinition' Oakridge WeatherGuard' HP 5.5.1 Classification by ASTM D7158: ASTM D7158, Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. MEMO ETC, LLC Evaluation Report 037440.02.12-R11 Cerrifkote of Authorization #32455 7T" EDITION (2020) FBC NON-HVH2 EVALUATION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11;12/11/2020 Page 3 of 10 ONFL4niPte TABLE 2B: WIND ClA5SIFICATIM, STARTER STRIPS AND HIP & RIDGE Type Product Starter Strip Shingle FBC Table 1507.2.7.1 or R905.2.6.1 Starter Strips ASTM U3161, Class F starter Strip Plus SRS TopSh1eId Starter Hip & Ridge Shingles Berkshire' Hip and Ridge Shingles with Sealant ASTM ❑3161, Class F ❑uraRidge® Hip and Ridge Shingles with Sealant ProEdgem WeatherGuard' HP Hip and Ridge shingles 5.5.2 Refer to Owens Corning published information on wind resistance and installation limitations. 5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. Refer to the Product Approval of the component manufacturer for components that are produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report. 6.1 GENERAL: 6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the limitations set forth in FBC Section 1511 or R908 and published installation instructions. 6.2 ACCESSORY STARTERS: 6.2.1 Installation of Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter shall comply with the Owens Corning current published instructions, using minimum five (5) nails per strip. Figure 1: Minimum Nailing, Starter Strip Fakundwhyma-A iktlk Salia[drar.d Waaeha,lpe� undarlaYroara drip adga Hdk lxand , - 2"-3"ham acre iuni rust Starts Strip Flue �� aaw with 6" ranwved ._ SruW Ship An worha w aarec and rakaa 114 Vd' Figure 2: Minimum Nailing, Starter Strip Plus NEW ETC, LLC Evaluation Report 037940.02.12-R11 Certificate of Aurhariratron#32455 7; H EDITION (2020) FBC NON-FIVFIZ EVALUATION F1.10674-1115 Owens Corning Asphalt Roof Shingles Revision 11:1211112OZO Page 4 of 10 ONEMOjetc. 6.2.2 Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions. edge Starter Shingle Roll adhered directly to underiayrnent and primed drip edge Figure 3: Starter Shingle Roll 6.3 ASPHALT SHINGLES: 6.3.1 Installation of asphalt shingles shall compiy with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Berkshire' shingles require minimum five (5) nails per shingle. ➢ WeatherGuard' HP shingles require minimum six (6) nails per shingle. Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required Refer to Owens Corning published information on wind resistance and installation limitations. 6.3.1.1 Sum Normal Mansard or Aran pare Wind Areas High Wind deavanss y Aran pure vientoa nornwfes Areas vientoa fbartas r1' 2' F Exposure Eicl—icinn Figure 4: Minimum Nailing, Supreme (Standard Size) Normal Wind Arises Area pars vientoa norrnsles 1" {Ai �• 12 T2 7 t 5 51ir Exposure Exposicfon Mansard or Anne piers High Wind deavenes y Area@ vientoa h►ertas rt' 2' {Bl z" t IL Figure 5: Minimum Nailing, Supreme (Metric Size) NEMO ETC, LLC Evaluation Report 037940.0Z.12-R11 Cerrrfcete ofAutharirotion #32455 P' EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-1116 Owens Corning Asphalt Roof Shingles Revision 11: 1Z/11/20Z0 Page 5 of 10 6.3.1.2 Berkshire®: Sealant strip La !Wei de 50a" Figure 6: S-Nail Pattern, Berkshire ONEMOletc. Figure 7: 6-Nail Pattern, Berkshire SeabN ship I,a !ha da selladpr T' 8 �h'• S �' S lg' S'IP' i E Asphalt rotting o;Mgnt Cemenio de techc de aaraRa Figure B: Mansard or Steep Slope Pattern, Berkshire NEMO ETC, LLC Evaluation Report O37940.OZ. 12-R11 Certificate ofAuthariration#32455 71" EDMON (2020) FBC NON-HVH2 EVALUATION FL10674-1116 Owens Corning Asphalt Roof Shingles Revision 11.12/11/2020 Page 6 of to 6.3.1.3 fONEMOjetc. Duration® Premium TruDefinition" Duration DurationO Premium COOL & TruDefinition' Duration' Designer Color Collection: NEW ETC, LLC Cerdfocvte of Autharizarfon #32455 4-Nall Fastening Pattern Sur■Nai[V tasiening area width N -I, Typical 12" 1 12' 3.. �'.R�4' �Y �k�Mx+ ••...._._._.. � - S 1�;!'+ui'Afti I f}awe�, GS1ir.7�SfIn11rR� fff■ ezpaswe 1 L. ....... Figure 9: Standard 4-Nail Pattern, Duration 6-Nail Fastening Pattern SureNaiM fastening area width Hail, Typlcat 1" 17, &-418" 3-SIg" e.vasu.e Figure 10: 6-Nail Pattern, Duration Figure 11: Mansard or Steep Slope Pattern, Duration VH EDITION (20201 FBC NON-HVH2 WALUAT10N Owens Corning Asphalt Raof Shingles Evaluation Report 037940.02.12•R11 F1.10674-1116 Revision 11:12/11/2020 Page 7 of 10 6.3.1.4 iruDeftnitione0akrid e® Oakridge*: 4 Nail Pattam Esguema con 4 claims I 5618" Exposure NaF1s 5 5.'8•' Exposure Erpmidlip de 5 5f8 pLdg. Warms Exposkbn de 5 S/Bpufg, Figure 12: Standard 4-Nail Pattern, Oakridge ONEMO I etc. 9 Nall Pattern Esguame non s claws k� 12. ­04 ... . ............ ....... - . . .... 5518 Ex afore Nails p Gloves 5 5,8 Exp6sura Expmkidir de 55/8pulg. Exposid6n de 5518puf4g. Figure 13: 6-Nail Pattern, Oakridge Fastening far Slopes Greater Than 21:12 StRaNdiW fastening area width Hail, ryp 1 F, 10 8.1r8° 5-518" eFoarr # 2r, Four 1" Spots of Asphalt Raofi rig Cermnt Figure 14: Mansard or Steep -Slope Pattern, Oakridge 6.3.L5 WeatherGuard® HP: 6 Mall Pattern Esquem con 6 davas mil $ 11' fFom bomm of shin@ CloVs 5 M' Ex parie inta er e m e & Fasteners p8 6de le Exposidki de 5'$ ping. $ sujetadares ts tea 12Rd4`-'"�� I� 12 Pk I j t. 1 IL fl i� z• Ulm Four 1m>t ' Spats of Asphalt Roof Cen1 5 s' gxposue 5 5 8' 5 maa cumfo pmbs de cemantn de Who de udfdlta do T da �losicd++da 5 5g r�� &pasic+81 5r 5 5 8 p,g. figure 15: 6-Nail Pattern, WeatherGuard HP Figure 16: Mansard or Steep -Slope Pattern, WeatherGuard HP NEMO ETC, LLC Evaluation Report 037940.02.12-1111 Cert'dicateo(Ruthorizatlon N31455 7'" EDITION (2020) FBC NON-HVH2 EVALUATION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11,12j11/2020 Page 8 of 10 6.4 HIP AND RIDGE SHINGLES: ON EMo f etc. 6.4.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions. Berkshire' Hip and Ridge Shingles with Sealant and DuraRidge® Hip and Ridge Shingles with Sealant require minimum two (2) nails per shingle. WeatherGuard* HP Hip and Ridge Shingles and ProEdge' require minimum four (4) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations. 6.4.1.1 Berkshire' Hip and Ridge with Sealant and DuraRidge" Hip and Ridge Shingles with Sealant: Fig. A Clails avas Prevailing Wind Direction Diretcidn der viento predominante I I i a I II I ' deb;algJ II � Figure 17: Isometric View, Berkshire and DuraRidge 6.4.1.2 WeatherGuard® HP Hil> and Ridge Shingles - Fig. A p 4 nat� it—Olraclbn A� Wens 4 E p I I 4 I � I 1 I 1 exposure Fig. B Top view Vista superior Nail 2W' Ciavo e 0VMUCorning Sur'eNad' • I I I� �Iw c {1T U yI m �I IF I fE 12" Figure 18: Plan View, Berkshire and DuraRidge Fig. C Hip & Ridge Shingle Fastening TopVlm Walls Nails 7„ 2 , 21" i �• ecposvra �! Figure 19: Isometric View, WeatherGuard HP Hip and Ridge Figure 20. Plan View, WeatherGuard HP Hip and Ridge MEMO ETC, LLC Eva Iuativn Report 037940.02,12-R11 Certriicateo(Ruthorirntian #32455 7- EDITION (2020) FBC NON-HVHI EVALUATION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 9 of 10 6.4.1.3 ProEdgel*: Prevailing Wind 131111tion S■alant Strip 6' Exposure Fasten 71h' Cave, Espased fasteners with Reef Cament Figure 21: Isometric View, ProEdge ONEMOjetc. Standard �1'V- Fastening Pattern T- �` I r t2` � �Ili■nt 7 ik" g° gacpasure f �` t2tl Figure 22: Plan View, ProEdge BUILDING7. ■ As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. QUALITY9. PRI Construction Materials Technologies, LLC—QUA91101 813 621-5777; bwilson@pricmt.com - ENO OF EVALUATION REPORT - NFMO ETC, LLC Evaluation Report 037944,02.12-R11 Certificate o(Authorizatron #32455 7T" EDITION (2020) FBC NON-HVHI EVALUATION FL10674-R1G Owens Corning Asphalt Roof Shingles Revision 11:12/11/2020 Page 10 of 10