Loading...
HomeMy WebLinkAbout212303-1d Compaction - signedHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net DATE TESTED:KSM JOB #:212303-1d/CF/bm PERMIT #:NUC #234 CONTRACTOR:Wynne Development Nuc Model:MC-DR JOB LOCATION:65 Camino Del Rio Nuc Serial #:MD60308234 Port St Lucie, Florida ITEM TESTED:Compacted Foundation Fill TEST LOCATION OF SAMPLE DEPTH PEN READ DRY DENSITY MAX. DRY PROCTOR VALUE (P.C.F) PERCENT COMPACTION 1. S.W.0" - 12"45 106.2 108.0 98.3% 2. N.W."50+107.4 "99.4% 3. Center ""107.2 "99.3% 4. N.E.""106.4 "98.5% 5. S.E.""106.8 "98.9% Soil Description: Brown/Gray Sand In Place Moisture: 7.1% Proctor Optimum Moisture: 12.0% Proctor Max. Dry Density: P.C.F. 108.0 @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets Minimum Requirement for Unstaked Foundation Respectfully Submitted: Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 3/29/2021 Email to: dotty@wynnebc.com Proudly Serving Florida since 1990 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 March 26, 2021 20120680 Disclaimer:Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the tested area has been altered from the approved inspected condition. 106.0 107.0 108.0 109.0 10 11 12 13 14 W E I G H T P . C . F . D R Y Moisture -% of Dry Weight