HomeMy WebLinkAboutAPPROVED, design pressure calcsPARADISE EXTERIORS
"Building Our Quality Reputation
One Customer At A Time"
SCC131150472
Information
Owner: RAYMOND DUA.RTE & JADE KREST
Address: 2100 ESPLANADE AVE W
FORT PIERCE, FL 34982
Bu i lding fi�folirlation
Wind Zone: 170 MPH.
Exposure Category: C
Minimum Building Dimension: 24 ft.
Mean Roof Height: 12 ft.
Risk Category: II
fI DesiLyn Pressure Calculations11
Opening Location 11
Device
Device
Device
Max Positive
Max Negative
Number Zone Width (in) Height (in)
.__
Elevation (ft) Pressure (psf)
Pressure (pst)
1 lilt�._
109
48
7
34.6
-37.8
..................................................... ...................................................................
2 End
.
72
61
7
35.1
451
........
3 End
... . ............ ............. ....... ...... .
36
61
7
36.8
-48.5
4 Int
51
37
7
37.1
40.3
5 Tilt
35
37
7
............... ..... ... ........
37.8
-41.0
6 Int
25
37
7
37.8
-41.0
7 lilt
........ ._ _ _. .........
35
37
7
37.8
41.0
8 End
. .........
51
37
7
37.1
-49.3
9 Ei d
35
37
7
37.8
50.6
10 End
35
37
7
...... ..._._.
37.8
50,6
11 End
51
36
7
37.2
-49A
12 Int
72
49
7
35.6
-38.8
13 Int
35
48
7
37.4
40.6
..............................................
14 Int
35
49
7
37.4
-40.6
15 Int
36
61
7
36.8
-40.0
I6 Int
36
61
7
36,8
40.0
I'mP fired rrr accordance millo.- ASCL 7-16. Crapfer 30. Wiud Loads - Lb»rpurrerrls rrru! C.'lutldirrg. 71h k,'dilion (1020) F7xmdu Building Code.