Loading...
HomeMy WebLinkAboutRevisions; Remove window in laundry, add outdoor Kitchenomf OFFICE USE ONLYY, : % DATE FILED: J r `� I REVISION FEE: D 1. LOCATION/SITE ADDRESS: PERMIT # a nbDtn,` RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772) 462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION DETAILED DESCRIPTION OF PROJECT REVISIONS: CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: BUSINESS NAME: QUALIFIERS NAME: ADDRESS: CITY: PHONE (DAYTIME): STATE: OWNER/BUILDER INFORMATION: ST. LUCIE CO CERT. #: ZIP: NAME: IERAIWO AY& A ADDRESS: )1go Apz" CITY: pjA STATE: FL ZIP: PHONE (DAYTIME: FAX: ARCHITECT/ENGINEER INFORMATION: NAME: _ ADDRESS: CITY: PHONE (DAYTIME): SLCCC: 9123109 Revised 06130/17 STATE: ZIP: FIDE C®PY Norman Cabrera, PE Fl. # 74093 605 Belvedere Rd. #7 West Palm Beach, Fl. 33405 561-249-1212 December 28, 2020 Job Address: 354 Melton Dr. Permit#: 2007-0395 To Whom it may concern, This letter is to address soffit screen vent at above referenced project. The plans call out a 7" x 20" screen vent @ 6' 0" o/c. The builder would like to use a 3" continuous screen vent. This still meets the needed free vented area. Please accept this letter for the change in soffit/attic venting. FBC 2017, 6 h Edition building code. If you have any questions please do not hesitate to call, thank you. Respectively submitted, rely, ,r Norman Cabrera, PE 1 #74093 DEC 2 q 2020 131-411 1'-4" LINTEL EAM 1 I .,CMU �16"XI6"X94" CONC. FILLED A1-4 COLUMN W/ (4) V I a 5 REBARS VERT. TYP 11 1 I. At tu CL mQCO W O111A�j=' Q1 r cq go cl v UUluu in JL -.id ED IL E cv II COVE I RED >: - Z tQ I PATIO - r g 1 119 9'4 " CEILING ��, I 1 I �i (V - -C3, - ra LTU r IJ I , 11 L u- 7 I 111. f� FRONT ELEVATION SCALE: 1/4" = 1'0" ' 2-5 514 3'p' X,, (V TOP ® SO' A.F.F, FRENQH DOOR MICRO u IMPACT u m DINING p" w m _ ® 9'4' CEILING .4 I , Y a m lit 18'-$" 3 11'-V 11 _ _ "r IL N F N K[TCHEN ° 9'4" CEILING o EF O DOOR LIVING - 6., � ROOM 'II ------ ------- -- N 9'4"' CEILING U7 ILI1fY - WIC 0 O 1 94" CEILING _ i -^ i In V PHR TBTACK. O fv °O 2 X80 4" THI A/ COMP. m DOOR A/CP O xQ NEIGH m 221v DI51- 1 " O ao MASTER Q m u� BEDROOM o >r 1n 12'4'10 9'4" CEILING m w a g O 4 BEDROOM l -' - SW' CEILING �o m ® } m DOOR, - a m 11 x 61_211 W. -M—ASTER SATW 0 x 9'4"C.. 1t _- . CU '-- ------Q _ BAT - RECESS _c " clk x° m Q c0 s a D- ------ --- - x' p Q, 0 - -11 WALL INS. N'0" X 6.61, SI-FOLD Q ATTIC I a'il ACCESS-STO� EDROOM 2 1-3/8". THICK L _T4""mac 22_ J ISERD 9'4' CEILING 41-2" srLF-e_LOSII, G ONE CAR q� z GARAGE 9'4" CEILING a m 'O 3-5 514 EGRESS 30" x aId. I .. ----' X -O" `--- GARAGE DOOR --8'—----------- TOP o 8'0" A.F.F. DOOR. I i ' I V LLI FRONT z ; ; PORCH', @" Q. CMU E BL. COL. LINTEL BEAM2 _O" WATER - STOP --------- •5 REBAR___..__'_-_-` _-I_I/Z"_x 1, NULtu4 m CZ Q � m �a u}I � Lu F n ci upl Q 4 z UJI In K CONIC. � D VERIFY Q W z> Q � w lu d) t It ct) � � to Ir N m . .— i � Q 0 Q) CL on`t- RiVIEWED FOR 7) CODE COMPLIANCE +� ST. LUCIE COUNTY BOCC V 3 �3bfS10 �� 0 11-� GOP*,_F O AREA TASS u 2-6 u "-10"-I" 10'-3° -l" A/C LIVILIVINGAREA: 1513 SQ FT 6 -6 6 8 FRONT PORCH: 59 SQ Ft ONE CAR GARAGE- 265 SQ FT JOB 19-150 TOTAL AREA: 18el SQ FT SHEET V I 0 200 AMP - --- - - ELECTRIC PANEL CIRCUIT NO. DESCRPTIO 4 POLE WIRE AMP - CIRCUIT NO. DESCRPTION POLE WIRE AMP LIVING ROOM 1 1 12 20 1500 2 DISHWASHER 1 12 20 1500 3 LIVING R 11 OM 1 12 20 1500 4 MICROWAVE 1 12 20 1500 �✓ BATH GFI' 1 12 20 1500 (O A/C COMP g 10 30 _ — — _ BEDROOM 022 1 14 15 1500 8 9 A/H/U 1 10 30 (10,000) 10 REF. 1 12 20 1500 12 RANGE 2 6 30 5,000 13 WATER MTR, 2 10 30 4,500 14 15 16 PUMP 2 12 20 3,000 11 �APPLIANCEES 1 12 20 1500 1 18 I9 APPLIANCE S 1 12 20 1500 20 WASHER 1 12 20 1500 21 BEDROOM 03 1 I 14 15 1500 22 DRYER 2 10 30 5,000 23 MASTER BEDROOM j 1 14 15 1500 24 W 25 KIT I' I 2 5 26 s/D'S 1 12 20 1500 outside ISHII 1 12 20 1500 28 CcEN LTG,. 1 12 20 1500 29 sP 30 GEN LTG. 1 12 20 1500 31-313 SPARES 32-40 SPARES TOTAL = IS,500 + TOTAL = 23,500 = TOTAL COMBINED = 43,000 FIRST 10 K.W. 0 100 % 10,000 REMAINDER 6 40 % 12,600 AC 10 K.W. B 100 95 10,000 TOTAL 22,600 22,600/ 240 = 136 AMPS GROUNDING AND BONDING, TAMPER RRG"i ESISTENT RECEPTACLES. INTERSYSTEM BONDING TERMINATION. TAMPER + -1(o% OF FIXTUR 5 TO BE ENCRY EFFEC.IENT. ' * FAN BOXES TO WITHSTAND MINIMUM 70 LBS, LOCATE ALL TC AND PHONE JACKS. IN FIELD. i 3(210)' C.U. IN 2- CONDUIT (200 AMP) O 200 AMP ELEC. PANEL METER MAIN CIRCUIT BREAKER ALL COPPER WIRING NDERG'OUND INTER15YSTEM U BONDING BY UTILITY COMPANY z• SCHD:.. #4 BARE COPPER WIRE TO 40 PVC /8u GLV. D x 2 5 R COLD TER PI E A O CO WATER C.W.P. AND FOUNDATION'REBAR TO 5/8" DIA 20' I LECTRICAL RISER DIAG RAM RAM G I , ELECTRICAL LEGEND ELECTRICAL COUNT SYMBOL ceiling fan 5 bladed 01 5 O can light 4inch LED 1 p can light 6inch LED 20 O ceiling dish round i O ceiling light 14 LED 1 fluorescent light 1 x 4 LED 1 E.--: = fluorescent light 2 x 4 LED 1 pendantcone 3 O exterior light 01 LED 2 0 electrical. panel 1� LAN connection 2 I cable tv outlet 5 119 doorbell pushbutton 1 Q fan 50 CFM 2 50 CFM light LED 1 outlet 23 outlet.220v 3 ,lµ outlet gfi 16 den smoke detector 5 split receptacle 2 switch 20 switch 3 way 11 $ 3 vanity bar light 02 2 o o 0 ,COVERED , �. ' LU Ctl Q- Ln 6PATIO .. 4P ly 6 1In S'4 CEILING , I qu O LIn-- C'`7 Lr ll-1 I GQ1�( UIli UILLcliI 1 Il �:j > rn � I II I, o LU ' DRO tQi z In 1 RC01T 13 VH JT-------- or- - - DINING 9'4" CEILING / ( I _ ' V ! 13 • o U � / I KITCHEN l7 i U j94" CEILING GP 61 Q �- -_-_- D/W DISP05AL .d) LU III (3 T CIRCUIT a -1 ri1 / V tu — -A `"— r� YREF duLC0 in - -- - -- _-- -- METER SL Q IU // o / /LIVING / U ROOM , / 94,CEILNG ' /. UTILITY. 1 I \i WIC n/ � 1A. I Q /H DI STACK •--.--- < I A!G COMP. 0 Y z -° \ U —441 ' Q Iil < , (V Z B,gOM ll I MASTER A \ ` � z BEDROOM �6 94 CEILING 3Idt W- V T' Gue5T m BATH Z ( MASTER .i.}, 5 C FM gaTN 9 ------ ----- ' _ Cq P !L zi�Q U Q ® Q) / . Arnc I �i F n IAcross 1!— BEDROOM ? J: ' - \ L _ _ 200 AMP I' -� ` / — ELEc �` al 94'CEILING I \ PANEL O v , E ' \ . ON GARAGE ' ` \ , 9'4" CEILING Q)A�p`� PRE -WIRE GARAGE E '---`-- OPENER FRONT PORCH LED I , / ,ra ----------- ----------- AN ------- �`�,�C,V ELECTRICALPL �$�® lu :3SCALE: 1/4° - 1,011 1 s � AREA TABSlI�� �L1 Q) L A/C LIVING AREA- 1513 SQ FT JOBMI 19-150 SKEET . I rYi' 1 I K' Wr k SAF Q} A MQ {V � I • $ R®4RB VBM. TYP.' L [[yy JU '..' tit .. I. - i .r. '. - ,£ 'q 1"iE'GI- ANICAL FLAN ` � �GQ, off{ a j SCALE 1/4 Ificon ' 'PORC14; 1 S 4 A4(C L 1v'(NG AREA: 1513 SQ Fi FRONT PORCH: sa60 Ft �+ 19�f50 ONE CAR GARAGE- 26S SQ Irr TOTAL AREA: iS91 SQ Fr T