HomeMy WebLinkAboutAPPROVED, Metal Product Approval1/18/2021
Florida Building Code Online
BCIS Home Log In User Regtstratian Hot Topics Submit Surcharge stats & Facts
r rLs=
^' Product Approval
�t ;USER: Public User
F
ro e ct A praval Menu > Prod_ uct or A.oplicatian Search > App ica an List > Application
Detail
w FL #ON FL17022-R8
Application Type Revision
Code Version 2020
Application Status
Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed the
Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
5.
Publications contact Us BCIS Site Map Llnk Search
Extreme Metal Fabricators, LLC
2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
flvalidation@yahoo.com
Richard McKuhen
flvalidation@yahoo.com
Richard McKuhen
2160 SW Perna Drive
Palm City, FL 34990
(772)872-8034
richard@emfat).net
Roofing
Metal Roofing
611 %. \
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
David Eng
PE-81377
Keystone Certifications, Inc.
04/22/2024
James R Wally, PE
Validation Checklist - Hardcopy Received
FL17022 R8 COI 26ga VMAX plywood odf
Standard
TAS 100
TAS 125
UL 580
Method 1 Option D
10/05/2020
10/12/2020
Year
1995
2003
2006
https://www.floridebuilding.org/pr/pr app_dtt•aspx?param=WGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR°lo2bd%2buNXXG%2bniRhGTtoBWM1aQ%3d... 112
1/18/2021
Date Pending F8C Approval
Date Approved
Date Revised
FL #
17o2z.1
MOael, Number or Name
269a VMax on Plywood
Limits of Use
Approved for use in HVHZ: No
i Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design pressure: +N/A/-228
Other: Refer to evaluation report.
Florida Building Code Online
10/25/2020
12/15/2020
12/16/2020
17022.2 102: 032 Aluminum VMax on Plywood
Limits of Use --
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Prey
Description_-
269a (min) VMax SV panel with 24" coverage on i5/32" (min) plywood
or 3/4" (min) thick wood plank.
Installation Instructions T--
FL1702.2 R8 II 26ga VMAX (pywoo .pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
i FL17022 R8 AE 26ggL_VMAX plyw f
Created by Independent Third Party: Yes
Nominally 0.032" aluminum (or thicker) VMax 5V panel with 21°
coverage on 15/32 (min) plywood or 3/4" (min) thick wood plank,
----
Installation Instructions - - - _—'
FL17022 R8 TI 032
VerVM
ifieDA2T n pywood,pd
ng,P1377 Created by Ind- d
sure. +N/AJ-168.5
Other: Refer to evaluation report.
pen ent Third Party: Yes
Evaluation Reports
"�------------
FL17022 R8 AE 032 VMAX i in piywood.pdf
Created b rt . Yes
y Independent Third Pa7022,3
i1
_.
26
03: 26ga VMax on Plywood
26ga (vim) VMax SV pane! with 24'
coverage on 15/32" (min) plywood ;
or 3/4" (min) thick wood plank. Option for fasteners in the flats and in
Limits of Use - -- ^—___..
the ribs.
---.__..---
Approved for use in HVHZ: No
- -- - -
Installation Instructions
Approved for use outside HVHZ: Yes
s FL17022 R8 iI 26oa VMAX wood fla pdf
Impact Resistant: N/A
Verified By: David Eng, pE 8137j
Design Pressure: +NJA/-114,25
Created by Independent Third Party: Yes
Other: Refer to evaluation report.
Evaluation Reports
—�—_._.---------.--___----
FL17022 R8 AE 26oa VMAX olywoo¢ fiats pdf
Created by Independent Third Pa rty: Yes ;
17022.4
04: 26ga CorMax on plywood
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: NIA
Design Pressure: +N/A/-161
Other: Refer to evaluation report,
17022.5 t 05: 26ga CorMa:c on Battens
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: yes
Impact Resistant: N/A
Design Pressure: +N/A/-161
Other: Refer to evaluation report.
26ga (min) COrMax corrugated panel with 29.5" coverage on 15/32"
(mm) plywood or 3/4' (min) thick wood plank.
Installation Instructions
417022 R8 II 26_QA CorMax Plywood HVHZ pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R8 AE 26ga CorMax Plvwood HVH7-r,df
Created by Independent Third Party: Yes
26961 (min) CorMax Comegated panel with battens. 29.5" coverage on 2x4 (min)
Installation Instructions
FL17022 R8 II 26oa CorMax Battens pdf
fled By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 Rg AE269 a CorMax 8attens.p
Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road 1211ahassee FL 3 399 Phone: 850-4S7-1924
The State of Florida is an A VCM employer. CQgvr ght 2oo7-�n13 St - of pl -d :; prfvaw Stata,,,o+.. --
.- pse� ibll'b e t :: Refunds
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic Mali to this entity.
Instead, contact the office by phone or by traditional mail, if you have any questions, please contact 850.487.1395, *Pursuant to Section 455.275(1), Florida Statutes, effective octoher 1,
20e 2s licensees licensedmail under Chapter 455, F.S. must provide the Department with an email address if they have one. The email- provided may be used for official communication with the
licensee. However email addresses are public record. If you do not wish to supply a personal address, Please provide the Department with an email address which can be made available to
the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Prodott Approval
�7rov)ACCept3:
r`:1
Card
SAM
https:IlWw rflo idabuilding.org/pripr app d l.aspx?param=wGEVXowtDgv2aBQPHpQQe6rMZMkUEoRd/o2bd%2buNXXG%2bnlRhGTtoBwmiaQ%3d... 2/2
26ga (min) MAX over 15/32" (min) Plywood
Extreme Metal Fabricators
2120 SW Poma Dr I Palm City FL 34990
Product Description
5V Crimp style exposed fastener panel with 24" max coverage and nominal
rib height of 3/811.
Product Material
26ga (min) steel
Corrosion resistant per FE3C 1507.4.3 where required
Fastener
#9 or #10 x 1-5" fastener with sealing washer
Compliant with FBC 1506.6 where required.
Substrate/Deck
15/32" (min) Plywood or
3/4" (min) thick wood plank (min S.G. Of 0.42)
Evaluated by:
David Eng, PE
Timberlake Cove, LLC
3324 W Univ Ave #2061 Gainesville FL
FL PE 81377 1 FL CA 33344
"0111111'
MAX
F'L7A-R
Underlayment: Comply with local building code or FBC 1507.1.1 where required.
Slope: Comply with local building code or FBC 1507.4.2 where required.
Re -Roofing: This panel may be installed over a single layer of existing shingles as permitted
by local building code or FBC 1511, provided the existing roof meets the conditions required by
the applicable code.
Maximum Allowable Loads & Installation Requirements:
Method A: #9 x 1.5" fastener in 12"-12" pattern at 16" o.c.: 86 PSF
Method B: #10 x 1.5" fastener in 12"-12" gatter,n at 16" o.c., 93.5 PSF
Method C: #10 x 1.5" fastener in 12"-12" pattern at 8" o.c.- 101 p5F
Method D: #Jo x 1.5" fastener in 12"-12" pattern at 6" o.c.: 228 PSF
A factor of safety of 2 has been applied.
Technical Documentation:
This product has been tested to the UL 580 standard by Architectural Testing (now Intertek
Testing, TST-1527), report D05893.01-450-18, F3366.01-450-18, and 005893.02-450-18. As referenced in
FL 17022.01-R7
Compliance Statement:
This product as described has demonstrated compliance with Florida Building Code 2020,
1504.3.2 (non-HVHZ) as required by FL Rule 61G20-3, method ID.
This product as described has been tested and demonstrated compliance with:
• UL580 - Test for Uplift Resistance of Roof Assemblies
• UL 1897 - Uplift test for roof covering systems
Design Process:
The load tables in this report provides one prescriptive option for the fastening requirement
for the applicable wind loads for roofs within the parameters described. For roofs outside of
the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or
other design code in force, using allowable stress. These load tables are based on ASCE 7-16.
Use of these tables assumes that the structure is:
• Enclosed and conforms to wind-borne debris provisions and is a regular shaped building
• Is not subject to across -wind loading, vortex shedding, or instability; nor does it have a
site location for which channeling or buffeting warrant consideration
Engineering analysis may be completed by other licensed engineers for project specific
approval by local authorities having jurisdiction.
Certification of Independence:
David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any company
manufacturing or distributing products under this evaluation. The some entities do not have, nor will
acquire, a financial interest in any other entity involved in the approval process of the product.
Exclusions and Limitations:
Design of deck and roof structure (to include attachment of plywood or wood plank) shall be completed by
others. Fire classification and shear diaphragm design are outside the scope of this evaluation. Accelerated
weathering/sait spray is outside the scope of this evaluation.
This report is limited to compliance with structural wind load requirements of FBC 1504.3.2, as required by
Rule 61G20-3. Neither Timberlake Cove nor the manufacturer shall be responsible for any conclusions,
interpretations, or designs made by others based on this evaluation report. This report is limited solely to
documenting compliance with Rule 61G20-3, and makes no express or implied warranty regarding
performance of this product. Installation shall be subject to the local building code and authority having
jurisdiction; this report shall not be construed to supersede local codes in force.
Instructions:
Select the appropriate load table that applies to the
structure in question.
Determine the design wind speed for the project
location.
Use the attachment method indicated for that
windspeed within each roof zone.
NOTE: ASCE 7-16 and FBC 2020 adopt a 7-zone concept.
For the load tables below, the worst case was taken
for each zone and reported using the standard zones
1-2-3:
Zone I includes zones I and V
Zone 2 includes zones 2e, 2r, and 2n
Zone 3 includes zones 3e and 3r
Combining these zones creates a clear, simple
scheme, of the expense of some design efficiency.
Contact the manufacturer for further information,
or consult a licensed design professional.
METHOD A:
#9 AT 16" O.C-
METHOD B:
#10 AT 16" O.C.
3'
a J
a
121
a
a
HIP ROOF GABLE ROOF
-4
A, -,a,, QP LEAST Hp1 1% S!— BUT NOT
OF LEAST HORIZONTAL oi
ORAS�TER"Et) mE,4s1on0R.�Tj,9,1,
�DMGNOR-. —PLIC .LCC0—
ROOF ZONES FOR GENERIC BUILDING
METHOD C: METHOD D:
#10 AT 3" O.C. #10 AT 6" 0, C.
r-12" (NOM)----T--12" (NOM)-------, NRi NOT RATED. CONSULT DESIGN
PROFESSIONAL AS NEEDED
Use this load fable for structures which meet the following criteria:
Are located in Exposure B area
Have either a flat roof, or gable/hip roof with max slope of 12:12
Have'a mean Roof Height of 30 feet or less
E—L17022.01: 2.6.qa_5V C_ rim on 15/32" @IVW00d
Wind 105 110 120 130 140 1.50 160 170 180 190 200
Zone 1: A A A A A A A A A A A
Zone 2-, A A A A A A A A C D,
Zone 3: A A A A A A B C
Use this load table for structures which meet the following criteria:
Are located in Exposure a area
Have either a flat roof less than 7°, hip roof with
max slope of 12:12, or gable roof with slope between 4.412 & 12:12
Have a mean Roof Height of 30 feet or less
M A--7-Aoq n-i. ex i
Wind ( 105) 110 120 130 140 150 160 170 180190o -20-0
Zone I A 'A A A A A A A A A A
Zone. 2: A A A A A A A A A 6 0
Zone 3:
�
A A A A A A A R
Use this load table for structures which meet the following criteria:
Are located in B, C, or D exposure area
Have either a flat roof, or gablelhip roof with max slope of -12:12
Have a mean Roof Height of 30 feet or less
FL17022.01: 26ga 5V.... --rjffw on 15M2" 12bMood
Wind 105 110 120 130 140 150 160 170 180 190 200
Zone 1: A A A A A A A C
Zone 2: A A A A
Zone 3: A A A C
All
Use this load table for structures which meet the following criteria:
Are located in B, C, or D exposure area
Have either a flat roof less than 7*, hip roof with
niax slope of 12.12, or gable roof with slope between 4.4:12 & 12:12
Have a mean Roof Height of 30 feet or less
FL17022.01: 26ga LV_Cam_g on 15/32" 01VW00d
Wind 105 110 120 130 140 150 160 170 180 190 200
Zone 1: A A A A A A A B
Zone 2: A A A A -A