HomeMy WebLinkAboutAPPROVED, Roofing Information SheetsST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A, B, C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 Asphaltic Shingles A, B, D 1,2,4,5,6,7 Concrete or Clay Tile A, B, D, E 1,2,3,4,5,6,7 Metal Roofs A, B, D 1,2,3,4,5,6,7 Wood Shingles and Shakes A, B, D 1,2,4,5,6,7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED As Applicable): 1, Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3, Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RoofinfoFeb21 Rev Feb 18, 2021 Section A (General Information) Master Permit No. Process No. Contractors Name: LU4 �4VC01W eAt License # LL I Z 0 2 9 JobAddress ROOF CATEGORY ❑ Low Slope �❑//Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles El Asphaltic Shingles LgMetal Panel/Shingles ❑Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE_ / ❑ New roof ❑ Repair ❑ Maintenance 9 Reroofing ❑ Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) ) `L fib Total (SF) VA 00 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. bT LUCK Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: OA Product Approval No.: 14 A, Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': RA Zone 1: Zone 2: t4A Zone 3: t4 14' Max. Design Pressure, from the specific product approval system: 9N' Deck: Type: Gauge Thickness: is II� Slope: 'A V5- Anchor/Base Sheet & No. df Ply(s): Anchor/Base Sheet Fastener/Bonding Material: �44 Insulation Base Layer: ff 4k Base Insultation Size and Thickness: is N' Base Insulation Fastener/Bonding Material: VA to Top Insulation Layer: Nw' Top Insulation Size and Thickness: tSA Top Insulation Fastener/Bonding Material: TtV- Base Sheet(s) & No. of Ply(s): W, Base Sheet Fastener/Bonding Material: g1k Ply Sheet(s)' & No. of Ply(s): V114 Ply Sheet Fastener/Bonding Material: �4A Top Ply: 916' Top Ply Fastener/Bonding Material: NA Surfacing: 1.� A Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1': " oc @ Lap, # Rows ! @ � " oc Zone oc @ Lap, # Rows 1401 @ oc Zone 2EA " oc @ Lap, # RowsLA ®oc Zone 3L4 " oc @ Lap, # Rows!�a @ oc Number of Fasteners Per Insulation Board: Zone 1' � Zone 1:9yk Zone 2:�i�N Zone 3:t f` Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc., Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. Section D (Steep Slope Roof System) Roof System Manufacturer: Notice of Acceptance Number: Minimum Design Wind Pr gt�s/Iures, If Applicable (From RAS 127 or Calculations): :Zone 1:'4 Lone 2er1V0 ob k Zone 2n:lone 2r:`166 � Zone 3e'��fl� Zone 3r:" i00. Deck Type: 1 Nyw00a Roof Slope: Type Underiayment I `T, 150 4 : 12 Insulation: Fire Barrier: Ridge Ventilation? Fastener Type & Spacing: " Adhesive Type: � Type Cap Sheet — Mean Roof Height: Roof Covering: 2 6 G Type & Size Drip 2.G Z Edge: �'.LUCIE VIVORKS Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mf. If the Mf values are greater than or equal to the Mrvalues, for each area of the roof, then the tile attachment method is acceptable. Method 1'Moment Based Tile Calculations Per RAS 12T js (Zone 1: LAiP x I NW _ �) _ Mg: gCk _ Md ups Product Approval M, e (Zone 2e: -10, x I WN = th "- Mg: 94 = M.,%-kA Product Approval Mf N la (Zone 2n: t L x h 0 _ 'Ira ) - Mg: WYA = Mom, \ti 1L Product Approval Mf N (Zone 2r: 1401 x IA = 1�� � - Mg: Nb = Me Product Product Approval Mf "V31 (Zone 3e: KA x %INA _ ) - Mg: l = Mej. 1,�_ Product Approval Mfg (Zone 3r: W'N x X LEA = ; ) - Mg. r4l = Mar L Product Approval Mf L 2 Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (Mr) From Table Below Product Approval Mf Mr required Moment Resistance* Mean Roof Height Roof Slope 15' 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 *Must be used in conjunction with a list of moment based tile systems • For Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr If the F' values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable Method 3 "Uplift Based Tile Calculations Per RAS 12T (Zone 1: p x L_� =x W:=--�Ap ) -W:)�k4_ cos rt4\A =Fri µ'A Product Approval F' t401 (Zone 2e: JAA x l-ib =x W:= rA% ) -W: tAVI cos ram_=Fr2e 01 Product Approval F' 94 (Zone 2n: ri�A x LhAu =x W:=mac a_) -W: 91L cos r_ tAO=Fr2" Product Approval F' 90 (Zone 2r: RO x L k =x W:= tAA ) -W: �W cos r__qtiA=Fr2rt4O Product Approval F' t0, (Zone 3e: MVO x L KV1 =x W:= -ti ) -W: N0 cos r vO =Fr3e NN Product Approval F' tAA (Zone 3r: _t�O x L NN =x W:= r1101 ) -W: r41k cos r 1VA =Fr3rti Product Approval F' �44 Where to Obtain Information Description Symbol Where to find Design Pressure Zones 1, 2e, 2n, 2r, 3e, 3r From applicable table in RAS 127 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H lob Site Roof Slope 8 lob Site Aerodynamic Multiplier a Product Approval Restoring Moment due to Gravity Mg Product Approval Attachment Resistance Mf Product Approval Required Moment Resistance Mg Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application.