HomeMy WebLinkAboutAPPROVED, Underlayment Product Approval1/15/2021 Florida Building Code Online
BCIS Home Log In User Registration Hot Topics Submit surcharge stats & Facts Publications contact Us BCIS Site Map Links Search
„^
dbv%r Product Approval
. USER: Public User
ry It
..A�:'
Product Appreya! Meru > Product or Application Search > Application list > Application Detail
09
! FL # FL2569-1121
Application Type Revision
Code Version 2020
Application Status Pending FBC Approval
Comments
Archived
Product Manufacturer Soprema, InC. (Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville, NON -US 00000
(619) 478-2400
t
memathieu@soprema.ca
`u
Authorized Signature Marc -Etienne Mathieu
�6
memathieu @soprema.ca
Technical Representative Marc -Etienne Mathieu
Address/Phone/Email 1688 Jean-Berchmans-Michaud
Drummondville, NON -US 00000
(819)478-2400 Ext3327
memathieu @soprema. ca
Quality Assurance Representative lean -Francois Cote, Ph.D.
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca
Category Roofing
Subcategory Underiayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J. M. Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12121/2023
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL2569 R21 COI 2020 01 COI NIEMINEN pdf
Referenced Standard and Year (of Standard) an ar Year
ASTM D1970 201S
ASTM D4798 2011
ASTM D6163 2015
FM 4474 2011
FRSA/TRI Sixth Edition 2018
UL 1897 2015
Equivalence of Product Standards
Certified By
Sections from the Code
https://www.tloridabuilding.org/pr(pr app_dti.aspx?param=wGEVXQwtDgsKQFEnckB108ErxlUd3xY[zoPsogGi4itVgZ9SrxpeDg%3d%3d 1/2
1/15/2021
Florida Building Code Online
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Summary of Products
FL #�
Model, Plumber or Name
Method 1 Option D
12/16/2020
12/17/2020
12/26/2020
2569.1 Soprema Roof Underlayments —
Limits of Use
Approved for use in HVH2: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-150
Other: 1.) Refer to ER Section S for Limits of Use. 2.) The design
pressure noted herein pertains to underlayment systems used beneath
adhesive -set the systems. Refer to ER Section 5.8.3 for details.
Description
Self adhering roof underlayments
Installation Instructions
FL2569 R21 II 2020 12 16 FINAL ER SOPR€MA FL2569 R21 0„dif
Verified By: Robert Nieminen, P.E. PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FL2569 R21 AE 2020 12 16 FINAL ER 50PREMA FL2569 R2L.pdQ
Created by Independent Third Party: Yes
Contacts :: 2691 Blair Stone Road TaOahas@eee FL_ 32399 phone: 850-48 7-1824
The State of Florida is an AA/EEO employer. Cooyrioht 2007-20) 3 State of Florida :: Pftvacv Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity.
Instead, contact the office by phone or by traditional mail. If you have any questions, please contact $50.487,1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1,
2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the
licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an ay be address which can be made available to
the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
,. 2.
ctarztt "It 11111c'h
https:/lwww.floridabuilding.org/prlpr app dtl.aspx?param=wGEVXQwtDgsKOFEnckB108ErxlUd3xYlzoPso9Gl4itVgZ9SrxpeDg%3d%3d 2/2
Certiftcate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
120.;l 7Fi7-cl7Ac;
ENGINEER EVALUATE TEST CONSULT
Soprema, Inc. Evaluation Report S18010.06.09-R19
1640 rue Haggerty FL2569 R21
Drummondville, Quebec J2C 5P8 Canada
(819) 4?8-2400 Date of Issuance: 06/15%2009
Revision 19.12/16/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 7B' Edition (2020) Florida Building Code sections noted herein.
' DESCRIPTiON: Soprema Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEIVIO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO) etc. Evaluated" may be
displayed in advertising literature. if any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer
or its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 9.
Prepared by:
`LJ5SLlitrtlA•,. `D,
'..
ems...
Robert J.M. Nienninen PE;�3=
, ..
'`"
The facsimile seal appearing was authorized by Robert
:.:.�
Florida Registration No. 59166, Florida i�C A A/�E1g83
� t4.�y`F
fr``fifi�; Nieminen, P.E. on 12/16/2020. This does not serve as
tt "' an electronically signed document
CERTIFICATION OF INDEPENDENCE:
1. NEW ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
©2019 MEMO ETC, LLC
ROOFING COMPONENT EVALUATION:
(NNEmoletc.
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Soprema Roof Underlayments, as produced by Soprema, have demonstrated compliance
with the following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with the
following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use
set forth herein,
Section
Pro ilidi—
Standard
Year
1504.3.1
Wind resistance
FM 4474
2011
1504.3.1
Wind resistance
UL 1897
2015
1507-1.1, 1507.2.4, 1507.2.9.2
Material standard
ASTM D1970
2015
/ R905.1.1, R905.2-8.2
1507.3.3 / R905.3.3
Material standard
FRSA/TRI, Sixth Edition
2018
1507.11.2 R905,11.2
Material standard
ASTM D6163
2015
TAS110
Accelerated Weathering
ASTM D4798
2011
Enti
Examination
Reference
Date
ERD (TST6049)
ERD (TST6049)
Wind Resistance
2778.07.05
07/15/2005
ERD (TST6049)
ASTM D1970 / TAS 110 (QC)
S31370.03,10-1-RI
04/07/2010
ERD (TST6049)
FRSA/TRI 04-12 (OH)
ASTM D1970 (OH)
S11150-05.09-112
10/05/2010
ERD (TST6049)
ASTM D1970 (MS)
S37210,11.11
S37210.12.11
11/09/2011
12/01/2011
ERD (TST6049)
ERD (TST6049)
ASTM D1970 (MS)
FRSA/TRI 04-12 (MS)
S40540.02.13-1
02/19/2013
ERD (TST6049)
ASTM D1970 (13C)
S43530.02.14-1-RI
S44870.04.14-2
02/21/2014
04/02/2014
ERD (TST6049)
ERD (TST6049)
ASTM D1970 (QC)
$44870.04-14-3
04/02/2014
ERD (TST6049)
ASTM D1970 (OH)
ASTM D1970 (MS)
S44870.04.14-1
04/10/2014
ERD (TST6049)
ASTM D1970 (OH)
S44870.04.14-4
S40540.10.14
04/10/2014
10/31/2014
ERD (TST6049)
Tensile Adhesion / Long Term Aging
SOPC-SC7645.02.15
02/13/2015
ERD (TST6049)
Accelerated Weathering
S01PC-SC8520.04A4
04/27/2015
ERD (TST6049)
M-D(CER1592)
Wind Resistance
SOPC-SC14045.05.17-RI
06/07/2017
ICC-ES (EVL2396)
HVHZ Compliance
2015 ISC Compliance
18-0329.03
ESR-1524
06/28/2018
MEMO (TST6049)
ASTM D1970 / TAS 110 (OC)
SOPC-SC8970.08.15-Ri
03/01,12017
04/25/2018
MEMO (TST6049)
Wind Resistance
4-SOPC-18-003.08.18
08/27/2018
MEMO (TST6049)
ASTM 04798/D1970 (OH & MS)
4S-SOPC-18-002.05.19-A
05/31/2019
MEMO (TST6049)
Tensile Adhesion / Long Term Aging
4p-DOW-19-5SLAp-01.A.112
02/10/2020
MEMO (TST6049)
Peel adhesion (existing underlayments)
4j-SOPC-19-SSUDL-04.A
03/12/2020
MEMO (TST6049)
Peel adhesion (existing underlayments)
4j-SOPC-20-SSUDL-01
12/1612020
PRI (TSTS878)
Soprema, Inc. (PDM3511)
ASTM D1970 (MS)
Equivalency Declaration
SOP-064-02-01
SA SMOOTH PLY 40
12/03/2013
UL, LLC (QUA9625)
Quality Control
MLA File No. R16814
06/29/2015
12/10/2015
UL, LLC (QUA9625)
Quality Control
MLA File No. R27605
05/08/2019
UL, LLC (QUA9625)
Quality Control
Service Confirmation
06/29/2020
UL, LLC (QUA9625)
Quality Control
Florida BCIS
Current
NEWIC ETC, LLC
CertifICOM afAuthorizarion #-12455 Evaiustion Report S18010.06.09-R19
7T� EDITION (2020) FaC NON-HVHZ EVALUATION FL2569-RZI
SOPrema Roof Underlayrnents Revision 19; 12/15/2020
Page 2 of 9
4.1
4.2
4.3
4.4
4.5
4.6
4,7
4.8
4.9
4.10
4.11
4.12
413)
4.14
4.15
4.16
(NNEMO 1 etc,
Product
M
Material
Standard
Plant(s)
Description
Lastobond
Lastobond TV HT
A5TM D1970 and
Gulfport, MS
self -adhering, non -woven polyester fabric
FRSAITRI 09-18
surfaced, SBS modified bitumen roof
underlayment
Tri-Built S/A HTTU
ASTM D18170 and
Gulfport, MS
self -adhering; non -woven polyester fabric
Underlayment
FRSA/TRI09-18
surfaced, SBS modified bitumen roof
underlayment
Lastobond Shield
ASTM 01970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
modified bitumen roof underlayment available in
two widths, 36 and 45 inch
RESISTO SA SMOOTH PLY
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
40
modified bitumen roof underlayment
Lastobond Shield HT
ASTM D1970
Drummondvflie, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
Lastobond Pro HT-N
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
modified bitumen roof underlayment available in
two widths; 36 and 45 inch
Lastobond Pro HT-5
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
—Drummondville,
underlayment
EnviroShield
ASTM D1970
QC
—self-adhering, woven polyethylene —surfaced, high
temperature, SBS modified bitumen roof
underlayment
Lastobond 195
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, sand-
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
Lastobond Eaves
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, sand -
Protection Sheet
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
Lastobond Eco
ASTM D1-9-70
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
Lastobond Smooth Seal
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film -
HT
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
Tri-Built Smooth HT S/A
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film-
Underlayment
Wadsworth, OH
surfaced, 585 modified bitumen roof
underlayment
PrimeSource Grip -Rite
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film -
Smooth Seal HT
Wadsworth, OH
surfaced, SOS modified bitumen roof
underlayment
RESISTO L61236
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
TRI-BUILT Sand-R SA
ASTM 01970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Shingle Underlayment
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
DEMO ETC, LIC Evaluation Report S18010.06.09-1119
Certificate ofAuthorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION F1.2569-R21
Soprema Roof Underlayments Revision 19.12/15/2020
Page 3 of 9
4.17
4.18
4.19
4.20
Material
Product
Standard
Plant(s)
Description
PrimeSource Grip -Rite
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand-
Eave & Valley Protector
Gulfport, IVIS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
SRS Top5hield ICE &
ASTIVI D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
WATER DEFENDER
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
RESISTO LB1244
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
Colphene FR GR
ASTM D6163
Gulfport, MS
self -adhering, fiberglass reinforced, granule -
Wadsworth, OH
surfaced, S85 modified bitumen roof
underlayment
5.1 This is a building code evaluation. Neither NEIVIO ETC, LLC nor Robert - Nieminen, P.E. are, in anyway, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -
Dade Counties).
S.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5,5 Soprerna Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. if not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABiE 1: ROOF COVER OPTIONS
--15-072
i7gc-u"16,
2507.3
1,507.4 & 1507.5
1507.7
1.507.8 & 1507.9
Asphalt
-
Clay and Concrete Tile
Metal
Slate or
Adhesive-
Underlayment
Shingles
Slate -Type
Wood Shakes or
Attach
set
Panels
Shingles
Shingles
Shingles
Lastobond TU HT, Tri-Built ;/A HT TUI
Yes
Yes
Underlayment
Yes
Yes
See 5.6.1
Yes
Yes
Yes
(joint strips, 1507.1,1.2 /
11905.2.1.3)
astobond Shield, Pro HT-N, RESISTCISA
Lastobond Shield, Pro HT-N. RESI STOSA
Yes
SMOOTH PLY 40
SMOOTH PLY 40
YL
's
No
No
No
No
Yes
floint strips, IS07A.1.3 /
Lastobond Shield HT, Pro HT-S
i
t
Yes
No
No
Yes
Yes
Yes
Yes
Usintstrim 1507.1.1.3 /
EnviroShield
Yes
No
No
Yes
Yes
Yes
Yes
1
Uoint strips, isD7.i..i.2
1
-
R90a1,m)
Lastobond Eaves Protection Sheet,
Yes
Lastobond 195
T
Yes
No
No
No
No
Yes
Oflit strips, 1507.1.1,8 1
NEMO ETC, LLC Evaluation Report S18010.06.09-RI9
Ctntificate of Authorization #32455 7`4 EDITION 12020) FBC NON-MVHZ EVALUATION F1.2569-1121
Soprema Roof Underlavments Revision 19: 12/15/2020
Page 4 of 9
(z)i,11 ,
TABLE 1: ROOF COVER OPTIONS
1507.4 & 1507,5
1507.7
2507.8 & 1507.9
Asphalt
Clay and Concrete Tile
Metal
5la#e or
Mechanical
Adhesive-
Underlayment
Shingles
Slate -Type
Wood Shakes or
Attach
set
Panels
Shingles
Shingles
Shingles
Lastobond ECO, RESISTO L81236, TRI-
BUILT Sand-11 SA Shingle Underlayment,
Grip -Rite Eave & Valley Protector,
Yes
NO
No
No
No
Yes
Yes
TopShieid ICE & WATER DEFENDER,
Oomtstnps, 1507.IJ3
RESISTO L81244
_HT,
Lastobond Smooth Seat Tri-Built
Smooth HT S/A Underlayment, Grip -Rite
Yes
No
No
Yes
Yes
Yes
Yes
Smooth Seal HT
51 1507.2,13/
_05_1_L3)
Colphene FR G-R
Yes
Yes
No
No
No
Yes
Yes
00int strips, 1507.1.1.3
S.6.1 Adhesive -set tile is limited to use of the following Approved underlayment /tile -adhesive combinations_
TABLE IA: ALLOWABLE TILE ADHEsivE / UNDERLAYMENT COMBINA-nONSI
Underlayment Adhesive Florida Product Approval
Lastobond TU HT, Tri-Built SIA Dupont "Tile Bond"'" Roof'rile Adhesive" FL22525
HT TU Underlayment ICP Adhesives and Sealants "Polyset- AH-160- FL6332
5.7 Allowable Substrates:
TAstE 2SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment
Application
- Substrates (designed to meet wind loads for project)
Type
Primer
Material(s)
Lastobond Shield, Lastobond Pro
(Optional) ASTM
HT-N, RESISTO SA SMOOTH PLY
Deck j
D41, Elastocol Stick
plywood, OSB or Southern Yellow Pine
40, Lastobond Shield HT,
sheathing
Elastocol Stick Zero'
(Syp)
Lastobond Pro HT-S,
ASTM D41
structural concrete
EaviroShield, Lastobond TU HT,
insulation
(Optional) Elastocol
Dens Deck Prime or SECUROCK Gypsum-
Tri-Built S/A HT TU
Underlayment, Lastobond Eaves
I Stick Zero
Fiber Roof Board
Protection Sheet, Lastobond 195,
Lastobond ECO, RESISTO LB1236,
self-
TRI-BUILT Sand-R SA Shingle
adhering
Underlayment, Grip -Rite Eave &
Valley Protector, TopShield ICE &
Base Sheet
(Optional) Elastocol
ASTM D226, Type It felt or Modified Sopra-
WATER DEFENDER, RESISTO
Stick Zero
G
LB1244, Lastobond Smooth Seal
HT, Tri-Built Smooth HT S/A
Underlayment or Grip -Rite
Smooth Seal HT
Deck
(Optional) ASTM
Plywood
sheathing
D41
ASTM D41
structural concrete
self-
-
Insulation
(Optional) Elastocol
Dens Deck Prime or SECUROCK Gypsum -
Colphene FR GR
adhering
Stick Zero
Fiber Roof Board
Base Sheet
(,Optional) Elastocol
ASTM D226, Type 11 felt or Modified Sopra-
Stick Zero
G
- Refer to Tile Manufacturer's or Adhesive manufacturers Florida Product Approval for Over -turning Moment Resistance Performance.
MEMO ETC, LLC Evaluation Report S18010.06.09-Rl9
Certificate OfAuthorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION F1,2569-1121
Soprema Roof Underlayments Revision 19: 12/15/2020
Page 5 of 9
10 ],o T mi_,
�(Z_J
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment
Application
Substrates (designed to meet wind loads for project)
Type
Primer
Material(s)
Lastobond TU HT, Tri-Built S/A HT
TU Underlayment, RESISTO
LB1236, TRI-BUILT Sand-R SA
Shingle Grip -Rite
Underlayment, -Rite
g y p
Self-
Existing
RESISTO EXTERIOR
Existing sand -surfaced, glass -fiber surfaced,
Eave & Valley Protector or
adhering
substrate
PRIMER
mineral -surfaced or film -surfaced roof
underlayment*
TopShieid ICE & WATER
DEFENDER
* Final acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the Authority
Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive Lastobond TU HT, Tri-BuiltS/A HT
TU Underlayment, RESISTO L82236, TRI-BUILTSand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or TapShield ICE &
WATER DEFENDER self -adhering underiayments, contact RES15TO technical support.
5.7.1 Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof
cover is not slated for installation within 24 hours.
5.7.2 Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the
self -adhering underlayment
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with
the manufacturer's installation instructions, but —for mechanically attached underlayments or base sheets - not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions, but — for mechanically attached base sheets - not less than:
e FRSA/TR1 Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A,
Table 1(for Two -Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein (for other Underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile installation Manual, Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct -to -Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA%TRi
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Desien Pressure = -45.0 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) Elastocol Stick, Elastocol Stick Zero or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered.
#2 Maximum Design Pressure = -67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: Elastocol Stick Zero
Underlayment: Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered.
NEMO ETC, LLC Evaluation Report S18010.06.09-R19
Certificate of Authorization #3245$ 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19.12/15/2020
Page 6 of 9
#3 Maximum Desien Pressure = -120 0 psf: *NEMO etc.
Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional) RESiSTO EXTERIOR PRIMER
Base Ply: RESISTO SA SMOOTH PLY 40, self -adhered.
Underlayment: Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered.
#4 Maximum Design Pressure = -150 0 psf:
Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to
satisfaction of Authority Having Jurisdiction.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered.
#5 All other direct -deck, adhered Underlayment systems beneath the roof systems carry a Maximum Design
Pressure of -45 psf.
5.8.3.2 Mechanically -Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1
design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones
shall employ an attachment density designed by a qualified design professional to resist the elevated pressure
criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application
Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the
limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for
enhancements.
#6 Maximum Design Pressure = -60 0 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6-
inch o.c. at the 4-inch laps and 6-inch o.c. in three (3), equally spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered
5.8.4 For use over insulation or coverboard and under mechanically attached prepared roof coverings, underlayment
attachment shall be in accordance with the manufacturer's installation instructions and attachment of the
insulation or coverboard shall be in accordance with the prepared roof covering manufacturer's Product
Approval.
5.9 Exposure Limitations:
TABLE 3: ExPosuRE LimffATioNs
Underlayment
Prepared Roof Cover
Maximum
Installation Type
Exposure (days)
Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, RESISTO LB1236, TRI-
BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector, TopShield iCE
Mechanically
& WATER DEFENDER or RESISTO L81244
attached
30
Lastobond TU HT, Tri-Built S/A HT TU Underlayment
Adhesive -set the roof
30
system
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Lastobond Pro HT-S, EnviroShield, Lastobond Smooth Seal HT, Tri-Built Smooth HT S/A
Mechanically
90
Underlayment or Grip -Rite Smooth Seal HT
attached
Lastobond TU HT, Tri-built S/A HT TU Underlayment or Colphene FR GR
Mechanically
attached
180
MEMO ETC, LLC Evaluation Report S18010.06.09-R19
Certificate o/Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION F1.2569-1121
Soprema Roof Underlayments Revision 19: 12/15/2020
Page 7 of 9
NNEMO I etc.
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TABLE 4, TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum Slope
Flat
Max. 10-tile stack
6:12
Lugged
Max.10-tile stack
5:12
Max. 10-tile stack (bottom 2-tile stack shall be inverted,
followed by S tiles high on slope as shown below)
6:12
Lastobond TUHT, Tri-
Built S/A HT TU
Underlayment
Lugged
g8
,
i
5.12
Colphene FR GR
Flat
Max. 10-tile stack
Lugged
Max. 10-tile stack
6:12
s
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate (if applicable).
6.2.1 installation of RESISTO 1_131236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or
TopShield ICE & WATER DEFENDER self -adhering underlayment in a reroof (tear -off) application atop an existing
underlayment (per Table 2) requires priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final
acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the
Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive
RESISTO 1_131236, TRi-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or TopShield ICE
& WATER DEFENDER self -adhering underlayments, contact RESISTO technical sunnnrt
6.3 Lastobond TU HT, Tri-Built S/A HT TU Underlayment, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA
SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, EnviroShleld, Lastobond Eaves Protection Sheet,
Lastobond 195, Lastobond Eco, Lastobond Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment, Grip -Rite
Smooth Seal HT, RESISTO L81236, TRi-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley
Protector, TopShield ICE & WATER DEFENDER, RESISTO L81244 or Colphene FR GR:
6.3.1 Non -Tile Applications:
Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in
FBC 2507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed, and the manufacturer's installation instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type Il felt the base sheet
shall be fastened in accordance with FBC 1S07.1.1 or R90S.1.1.
NEMO rtifk ET: LLCate of AuthEvaluation Report S1801o.06.09-R19
Certificoraatian#32455 7"' EDITION (2020) FBC NON-HVHZ EVALUATION FUS69-1E21
Soprema Roof underlayments Revision 19:12/15/2020
Page 8 of 9
6.3.2 Tile Applications: ONEMOjetc.
Limited to Lastobond TU HT, Tri-Built S/A HT TU Underlayment or Colphene FR GR.
Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRl Florida
High Wind Concrete and Clay ,Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation
instructions.
Refer to Section 5.8.3 herein for attachment limitations.
- END OF EVALUATION REPORT -
NEW ETC, LLC Evaluation Report S18010.06.09-1119
Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlavtnents Revision 19. 12/15/2020
Page 9 of 9