HomeMy WebLinkAboutAPPROVED, Curb Mount Attic Breeze Product Approval3/16/2021
Florida Building Code Online
W: �S+`'. �
r •c err 1'r5i�
t� �,
BCIS Home Log In User Registration Hot Topics
Product Approval
USER: Public User
Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links SearchF'i
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed the
Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL13339-R8
Affirmation
2020
Approved
Attic Breeze
1370 FM 116
Gatesville, TX 76528
(254)865-9999
travis.hipp@atticbreeze.net
Travis Hipp
travis.hipp@atticbreeze.net
Travis Hipp
1370 FM 116
Gatesville, TX 76528
(877) 288-4234
travis.hipp@atticbreeze.net
Roofing
Roofing Accessories that are an Integral Part of the Roofing System
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
James L. Buckner, P.E. @ CBUCK Engineering
PE-31242
Keystone Certifications, Inc.
12/01/2029
Michael John Riemer, P.E.
Validation Checklist - Hardcopy Received
FL13339 R8 COI COI CertOf Indep James Buckner,P.E. sc.PDF
1708.2
I affirm that there are no changes in the new Florida Building
Code which affect my product(s) and my product(s) are in
hops://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquFsbTbi%2b3jRWWJ%2bwxNA5%2bc%2bapmo3X8QNQHZRRZRWQ%2ftA,.. 1/3
3/16/2021
Florida Building Code Online
compliance with the new Florida Building Code.
Documentation from approved Evaluation or Validation Entity
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
FL #
Model, Number or Name
Yes No N/A
FL13339 R8 CDC Affirmation FL13339 ss.pdf
Method 2 Option B
11/04/2020
11/04/2020
11/05/2020
13339.1 Ol_Solar Attic Fan
I
Limits of Use
j, Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +115/-115
Other: Refer to evaluation report for limitations and conditions
of use. Refer to manufacturer's installation instructions as a
supplemental guide.
02_Solar Attic Fan
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +115/-115
Other: Refer to evaluation report for limitations and conditions
of use. Refer to manufacturer's installation instructions as a
supplemental guide.
13339.3 ' 03_Solar Attic Fan
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +115/-115
Other: Refer to evaluation report for limitations and conditions
of use. Refer to manufacturer's installation instructions as a
supplemental guide.
13339.4 04_Solar Attic Fan
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +115/-115
Other: Refer to evaluation report for limitations and conditions
of use. Refer to manufacturer's installation instructions as a
supplemental guide.
05_Solar Attic Fan
Description
Models AB-201A, AB-202A, AB-251A, AB-252A, AB-2022A, AB-
3022A & AB-4022A. Self -flashing, solar powered fan units, with
solar panel directly attached to fan unit shroud/dome
Installation Instructions
FL13339 R8 II 1-7 Attic Breeze-SPAF Panel Direct to Flush
Mount Unit EvalReport.pdf
Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242
Created by Independent Third Party: Yes
Evaluation Reports
FL13339 R8 AE 1-7 Attic Breeze-SPAF Panel Direct to Flush
Mount Unit EvalReport.pdf
Created by Independent Third Party: Yes
Models AB-201D, AB-202D, AB-251D, AB-252D, AB-401, AB-
402, AB-2022D, AB-3022D & AB-4022D. Self -flashing, solar
i powered fan units, with solar panel(s) remotely attached from
fan unit, using low profile mounting brackets
Installation Instructions
I FL13339 R8 II 2-7 Attic Breeze-SPAF Panel Remote to Low
Profile EvalReport.pdf
Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242
Created by Independent Third Party: Yes
Evaluation Reports
FL13339 R8 AE 2-7 Attic Breeze-SPAF Panel Remote to Low
Profile EvalReport.pdf
I Created by Independent Third Party: Yes
Models AB-201D AB-202D, AB 251D, AB-252D, AB-401, AB-
402, AB-2022D, AB-3022D & AB-4022D. Self -flashing, solar
powered fan units, with solar panel(s) remotely attached from
fan unit, using universal mounting bracket
Installation Instructions
FL13339 R8 II 3-7 Attic Br eze-SPAF Panel Remote
Inclined EvalReport.pdf
Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242
Created by Independent Third Party: Yes
Evaluation Reports
FL13339 R8 AE 3-7 Attic Breeze-SPAF Panel Remote
Inclined EvalReport.pdf
Created by Independent Third Party: Yes
Models AB-601, AB-602 & AB-6022D. Self -flashing, solar
powered fan units, with solar panel remotely attached from fan
unit, using low profile mounting brackets
Installation Instructions
FL13339 R8 II 4-7 Attic Breeze-SPAF Panel Remote to Low
Profile EvalReportpdf
Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242
Created by Independent Third Party: Yes
Evaluation Reports
FL13339 R8 AE 4-7 Attic Breeze-SPAF Panel Remote to Low
Profile EvalReportpdf
Created by Independent Third Party: Yes
Models AB-601, AB-602 & AB-6022D. Self -flashing, solar,
powered fan units, with solar panel remotely attached from fan
unit, using universal mounting brackets
https://www.floridabui lding.org/prlpr_app_dti.aspx?param=wG EVXQWtDq u FsbTbi%2b3j RWwJ%2bwxNA5%2bc%2bapmo3X8QNQHZRRZRWQ%2ftA.
2/3
3/16/2021
Florida Building Code Online
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +115/-115
Other: Refer to evaluation report for limitations and conditions
of use. Refer to manufacturer's installation instructions as a
supplemental guide.
13339.6
06_Cardinal Ventilation
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +115/-115
Other: Refer to evaluation report for limitations and conditions
of use. Refer to manufacturer's installation instructions as a
supplemental guide. _....
Installation Instructions
FL13339 R8 II 5-7 Attic Breeze-SPAF Panel Remote
Inclined EvalReport.pdf
Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242
Created by Independent Third Party: Yes
Evaluation Reports
FL13339 R8 AE 5-7 Attic Breeze-SPAF Panel Remote
Inclined EvalReport.pdf
Created by Independent Third Party: Yes
Models CV-2000 & CV-3000. Self -flashing, circular shaped solar j
powered fan units, with solar panel directly attached to fan unit
hood/dome
Installation Instructions
FL13339 R8 II 6-7 AB -Cardinal SPAF Panel Direct to Flush
Mount Unit EvalReport.pdf
Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242
Created by Independent Third Party: Yes
Evaluation Reports
FL13339 R8 AE 6-7 AB -Cardinal SPAF Panel Direct to Flush
Mount Unit EvalReportpdf
Created by Independent Third Party: Yes
9.7 'Curb Mount Series j Curb Profile vent fan base for attachment to roof curbs
Limits of Use I Installation Instructions T
Approved for use in HVHZ: No Ci FL13339 R8 II 7-7 Curb -SPA -CM -ER W 10 pdf
Approved for use outside HVHZ: Yes i Verified By: James L Buckner, P.E. @CBUCK, Inc P.E. # 31242
Impact Resistant: No I Created by Independent Third Party: Yes
Design Pressure: +115/-115 i Evaluation Reports
Other: Refer to evaluation report for limitations and conditions FL13339 R8 AE 7-7 Curb -SPA -CM -ER W 10 pdf
of use. Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 Stale of Florida :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 860.487.1395. 'Pursuant o Section electronic
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S„ please click here .
Product Approval Accepts:
t PW � LLJ
S£'f'uritk' ET 1i'S'
https://www.floridabuilding.org/prlpr app_dtl.aspx?param=wGEVXQwtDquFsbTbi°/a2b3iRWWJ%2bwxNA5%2bc%2bapmo3X8QNQHZRRZRWQ%2ftA... 3/3
E- 1 iI r!n
Specialty Structural Enginpc-rinq CBUCK, Inc. Certificate of Authorization #874
Evaluation Report
Curb Mount Profile Base
Solar Powered Roof Ventilation
Appendix A
To Evaluation Reports: FL13339 .1 To .5
Manufacturer
Attic Breeze, LLC.
1370 FM 116
Gatesville, Texas 76528
(877) 288-4234
for
Florida Product Approval
# FL 13339.7 R6
Florida Building Code 6th Edition (2017)
Per Rule 61G20-3
Method: 2 - B
Category: Roofing
Sub - Category:
Product Name:
Product Description:
Prepared by:
James L. Buckner, P.E., SECB
Florida Professional Engineer # 31242
Florida Evaluation ANE ID: 1916
Report No. 18-101-C-SPA-CM-ER
Date: 1 / 4 / 17
Contents:
Evaluation Report Pages 1— 6
Roofing Accessories that are an Integral
Part of the Roofing System
Curb Mount
Curb Mount Series
with Hood/Dome Mounted Solar Panel
& Remote Mount Solar Panel Facsimile of digital copy signed by
James L. Buckner, P.E.
Electronically signed and sealed documents sl
comply with the provisions of FAC Rule 61G15-
0 %t kll)►►//j//
4\CENSF !I,,Q�%
* ' No 31242
LUa
won' , ZZ
STATE OF ��`
i Fs''•.�CORtDP ••• �` �
r
CBUCK, Inc. - Palm Beach County, Florida
Phone: (561) 491-9927 . Email: cbuck@cbuckinc.net - Website: www.cbuckinc.net 2018.01.0415:00:37-05'00'
CBUCK Engineering
Specialty Structural Engineering
FL #: FL 13339.7 R6
Date: 1 / 4 / 18
Report No.: 18-101-C-SPA-CM-ER
Page 2 of 6
CBUCK, Inc. Certificate of Authorization #8064
Manufacturer: Attic Breeze, LLC.
Product Name: Curb Mount Vent and Fan Base Models
Product Category: Roofing
Product Sub -Category Roofing Accessories that are an Integral part of the Roofing System
Compliance Method:
State Product Approval Rule 61G20-3.005 (2) (b)
Product Description:
Curb profile vent fan base for attachment to roof curbs. Curb material is the
same as the self flashing base in FL13339 Evaluation reports .1 to .5.
Product Assembly as
Evaluated: Curb profile base attached to roof curb designed by others.
Appendix A Scope:
Model Numbers
Included in This Report:
This Appendix A is linked to FL13339 Reports .1 through .5
The vent units model numbers in this report are the same product specification
in Reports .1 to .5 , including the same minimum base specifications.
This report .7 includes additional model numbers. The envelope
structural components are the same as previous reports. The differences
are internal mechanical and/or electrical.
This report addresses options for attaching the Curb Profile to roof curbs.
FL13339.7
AB-1020
AB-2042A
AB-3042A
AB-4042A
AB-2042D
AB-3042D
AB-4042D
AB-6042D
FL #: FL 13339.6 R6
Date: 1 / 4 / 18
Report No.: 18-101-C-SPA-CM-ER
Page 3 of 6
Sppelalty Structuresi Engineering CBUCK, Inc. Certificate of Authorization #8064
Vent Unit Curb Base Support: Type & Minimum Strength Specification:
Design of curbs is outside the scope of this evaluation
1 Wood
Description:
15/32" or greater Plywood, or
Wood (based on minimum density/specific gravity of0.42)
2 Steel
22 gauge minimum thickness, 33 ksi minimum yield strength
(3) Aluminum
1/8 inch minimum thickness, alloy 6063-T52 or 6063-T6
Roof Slope: Slope shall be in compliance with FBC, Chapter 15 based on the type of roof covering.
Allowable Wind Resistance:
Performance: * Positive Design Pressure: + 115 PSF
* Negative Design Pressure: -115 PSF
*Allowable design pressures for allowable stress design (ASD).
Performance Standards: The following test protocol was performed to demonstrate compliance with the
intent of the code as this product does not specifically addressed the performance
standard in the code.
• ASTM E330-02 —Standard Test Method for Structural Performance of Exterior
Windows, Curtain Walls, and Doors and by Uniform Static AlrPressureDifference
Code Compliance: The product described herein has demonstrated compliance with the Florida
Building Code 6th Edition (2017), Section 1708.2.
CBUCK
Engineering
FL #: FL 13339.6 R6
Date: 1 / 4 / 18
Report No.: 18-101-C-SPA-CM-ER
Page 4 of 6
ISPeclalty structural Engineering CBUCK, Inc. Certificate of Authorization #8064
Evaluation Report Scope: This product evaluation demonstrates compliance of this product with the structural
wind load requirements of the Florida Building Code, as related to Florida Product
Approval Rule 61G20-3.001.
Limits of Use: . Scope of "Limitations and Conditions of Use" for this evaluation
This evaluation report for "Optional Statewide Approval" contains technical
documentation, specifications and installation method(s) which include
"Limitations and Conditions of Use" throughout the report in accordance with
Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is
the authority to approve products under "Optional Statewide Approval".
Option for application outside "Limitations and Conditions of Use"
Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific
approval by the local authorities having jurisdiction in accordance with the
alternate methods and materials authorized in the Code". Any modification of
the product as evaluated in this report and approved by the Florida Building
Commission is outside the scope of this evaluation and will be the responsibility
of others.
Design of support system is outside the scope of this report.
Fire Classification is outside the scope of Rule 61G20-3, and is therefore not
included in this evaluation.
This evaluation report does not evaluate the use of this product for use in the
High Velocity Hurricane Zone code section. (Dade & Broward Counties)
Quality Assurance: The manufacturer has demonstrated compliance of roof vent products in accordance
with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a
quality assurance program audited by an approved quality assurance entity through
Keystone Certification, Inc. (FBC Organization #: QUA 1824)
SPPcldlty Structural Engineering
Component(s)
Material Standards:
Evaluated Referenced Data:
Vent Base
Material
_ Thickness:
Yield Strength:
Corrosion Resistance:
Fastener for Wood Curb
Type:
Size:
Standard:
Corrosion Resistance:
FL #: FL 13339.6 R6
Date: 1 / 4 / 18
Report No.: 18-101-C-SPA-CM-ER
Page 5 of 6
CBUCK, Inc. Certificate of Authorization #8064
Steel
22 ga.
33 ksi Minimum
Galvalume or Zincalume per ASTM A792 AZ 50
or in compliance with the FBC, Section 1507.4.3.
Pancake or Hex Head Wood Screw
#10 x 1 in. Minimum
Per ANSI/ASME B18.6.1
Per FBC Section 1506.6
. Fastener for Steel & Aluminum Curb
Type:
Size:
Standard:
Corrosion Resistance
Self Tapping or Self Drilling Screw
#12 x 1 in. Minimum
Per FBC Section 1507.4.4 and/or SAE J78-1979
Per FBC Section 1506.6
1. ASTM E330-02 — Uniform Static Air Pressure Difference Test
By Certified Testing Laboratories, Inc. (FBC Organization IN TST 1577)
Project #: CTLA 2002W, Dated: 11 / 20 /09
2. Quality Assurance
By Keystone Certification, Inc. (FBC Organization ID# QUA 1824)
Attic Breeze, LLC. Licensee #740
3. Certification of Independence
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization # ANE 1916)
4. Engineering Analysis
By CBUCK Engineering
Report #17-144-EA, Dated: 6 / 11 / 17
EnginLmering
FL #: FL 13339.6 R6
Date: 1 / 4 / 18
Report No.: 18-101-C-SPA-CM-ER
Page 6 of 6
SpPclalty Structural Engineering CBUCK, Inc. Certificate of Authorization #8054
Installation Methods
Attic Breeze, LLC.
`Solar Powered Roof Vent Attachment To Curbs
Attach to Wood Curb:
Option to attach vertical leg or horizontal flange.
Screw: pancake head or hex head minimum #10 x 1
inch 3 screw on each side for a minimum total of 12.
Maximum spacing of 12 inches on center
and within 6 inches of corners
minimum distance to base edge 1 inch
Attach to Steel (22 gauge min) or Aluminum ( 1/8 in min.) Curb:
Option to attach vertical leg or horizontal flange.
Screw: pancake head or hex
head minimum #10 x 1 inch
3 screws on each side for a minimum total of 12.
Maximum spacing of 12 inches on center
and within 6 inches of corners
minimum distance to base edge 1 inch
Refer to manufacturer's installation instructions as a supplemental guide for attachment.