Loading...
HomeMy WebLinkAboutLot 7_2011-0432 COMMENTSPROPERTY INFORMATION Address: City / State / Zip: Parcel #: Zoning: 132 Ocean Estates Dr Fort Pierce, Fl 34949 1403-500-0023-000/2 PUD APPLICATION INFORMATION Permit Number: Permit Type: 2011-0432 BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS) CONTRACTOR INFORMATION Contractor Name: Business Name: Business Addr: City / State / Zip: Thomas R Iii Miller Trm Construction Management Inc 1512 Se Village Green Dr Port St Lucie, Fl 34952 REVIEWS AND COMMENTS Owner(s): Ocean Estates Drive Llc Jurisdiction:SAINT LUCIE COUNTY Lot#:7 Block:2 Stories:Automatic Sprinkler System? Fax Number: No Review Type Status Reviewed By Date Started Date Completed Date Released ADDRESSING ASSIGNMENT COMPLETE Lori Bender 11/23/2020 11/24/2020 11/24/2020 Comment: DOCUMENTS MISSING PENDING Karen Nielsen 11/18/2020 11/18/2020 Comment: CONTRACTOR TO UPDATE WORKERS COMP INSURANCE 11/18/2020 Comment: RECORDED NOC 11/18/2020 Comment: ELECTRICAL SUB 11/18/2020 Comment: PLUMBING SUB 11/18/2020 Comment: MECHANICAL SUB 11/18/2020 Comment: ROOFING SUB 11/18/2020 Comment: VEG PERMIT SCANNED IN LASERFISHE, FEES LOADED. EV FORWARDED VEG PERMIT AND SURVEY TO ERD. 11/23/2020 Comment: COPY RECEIPT FOR PAID UTILITIES WATER AND SEWER. ENVIRONMENTAL REVIEW COMPLETE Lynn Swartzel 11/23/2020 11/23/2020 11/23/2020 Comment: FRONT COUNTER REVIEW COMPLETE Karen Nielsen 11/18/2020 11/18/2020 11/18/2020 Comment: NOTIFIED FOR PICK UP PENDING Comment: Email:Paul@Trmcorpfl.Com REVIEW COMMENTS Page 1 PE REVIEW COMMENTS (2)INCOMPLETE Jpi, Inc-Andrew 1/13/2021 12/8/2020 Comment: THE DESIGN LOCATION ON THE ENERGY CALCULATION IS INCORRECT. CORRECT AND RESUBMIT. 107 FBC 6TH ED 2017 12/8/2020 Comment: SOFFIT DETAIL SF01D2 IS MISSING FROM PLANS CORRECT AND RESUBMIT 107 FBC 6TH ED 2017 12/8/2020 Comment: SUBMIT A COPY OF THE SOIL REPORT 107 FBC 6TH ED 2017 12/8/2020 Comment: SUBMIT PLANS FOR THE FIRE SPRINKLER SYSTEM 107 FBC 6TH ED 2017 1/13/2021 Comment: *SHEET L1- THERE ARE TWO LINTEL SCHEDULES WITH CONFLICTING SIZES & REINFORCING REQUIREMENTS. ([A]107.2.1) 1/13/2021 Comment: *E1.0- NO SMOKE OR CO DETECTOR IN BEDROOM ON THE FIRST FLOOR, LABELED AS STUDY ON A1.0. THE LAYOUT OF THIS ROOM IS THAT OF A SLEEPING ROOM. (R314, R315) 1/13/2021 Comment: *PLEASE PROVIDE AN ELECTRIC PANEL SCHEDULE AND ELECTRIC LOAD CALCULATIONS. ([A]107.2.1) 1/13/2021 Comment: *PLEASE PROVIDE A PLUMBING RISER DIAGRAM. ([A]107.2.1) 1/13/2021 Comment: *PLEASE PROVIDE THE MANUAL D WITH DUCT SIZE TABLE & DUCT LAYOUT. ([A]107.2.1) 1/13/2021 Comment: *PLEASE SEE TABLE R302.1, RATED EAVE OR BLOCKING REQUIRED WHEN LESS THAN 3 FEET FROM PROPERTY LINE. SPRINKLED BUILDING REQUIRED. 1/13/2021 Comment: *PROVIDE POSITIVE DRAINAGE AWAY FROM THE STRUCTURE. (R401.3) 1/13/2021 Comment: *PLEASE SHOW THE FLOOD ZONES ON THE SURVEY. ([A]107.2.1) 1/13/2021 Comment: *PRODUCT APPROVALS EXPIRED ([A]107.2.1) 17-0614.16- WINDOWS, MULLIONS, FIXED GLASS- EXPIRED, NEED SEPARATE PRODUCT APPROVAL FOR EACH PRODUCT 17-0420.12- SLIDING DOORS- EXPIRED 1/13/2021 Comment: *SHEET A1.1, SUSPENDENDED AIR HANDLER AND 50 GALLON WATER HEATER- PLEASE SHOW LOADING FOR THE ON THE TRUSS DRAWINGS. PROVIDE DETAILS FOR HANGING EQUIPMENT. ([A]107.2.1) PLANNING REVIEW PENDING Bethany Grubbs Comment: PLANS EXAMINER REVIEW COMPLETE Joseph Fersch 11/24/2020 1/13/2021 1/13/2021 Comment: ZONING REVIEW INCOMPLETE Lydia Galbraith 11/23/2020 11/23/2020 Comment: THE SURVEY HAS AN INCORRECT FLOOD PANEL AND YEAR. THE SURVEY WILL NEED THE FLOOD INFORMATION FROM THE MAPS OF 2020. PLEASE PROVIDE CORRECTED SURVEY. 11/24/2020 Comment: PLEASE BE AWARE THAT ABOVE COMMENTS ARE ZONING REVIEW COMMENTS ONLY. THE PLANNING DEPARTMENT AND PLANS EXAMINER MIGHT HAVE ADDITIONAL COMMENTS. REVIEW COMMENTS Page 2