HomeMy WebLinkAboutAPPROVED UL listing(1)UL
UL PRODUCT SPEC ™
1.HOW DO YOU WANT TO SEARCH ?
2.RESULTS
UL PRODUCT CATEGORY
Roofing Systems
See General Information for Roofing Systems
R11656CERTAINTEEDCORP
ROOFING PRODUCTS GROUP
20 MOORES RD
MALVERN ,PA 19355 USA
Minimum 1 /2 -in .thick gypsum board or minimum 1 /4 -in .thick Georgia -Pacific Gypsum LLC "DensDeck®Roofboard "
or "DensDeck®Prime Roofboard "or "DensDeck®DuraGuard ™Roofboard "or Minimum 1 /4 -in .thick United States
Gypsum Co."SECUROCK®Roof Board "(Type FRX -G )or "SECUROCK®Glass -Mat Roof Board "(Type SGMRX )
may be used in any existing noncombustible roof deck Classification .When this is done ,the resulting roofing system
is acceptable for use over minimum 15 /32 -in .thick combustible roof decks .However ,the butt joints in the gypsum
board and Georgia -Pacific Gypsum LLC "DensDeck®Roofboard "or "DensDeck®Prime Roofboard "or "DensDeck®
DuraGuardTM Roofboard "are to offset a minimum of 6 -in .with the butt joints in the roof deck .If polystyrene is part of
the roof covering system ,it must be placed below the overlayment board .Minimum 1 /4 -in .thick United Sates
Gypsum Co."SECUROCK®Roof Board "(Type FRX -G )and "SECUROCK®Glass -Mat Roof Board "(Type SGMRX )
are limited to a maximum 3:12 slope when used over a combustible roof deck in a system with any UL Classified
insulation except polystyrene ."
Any UL Classified insulation may be used underneath minimum 1 /2 -in .thick gypsum board or minimum 1 /4 -in ,thick
Georgia -Pacific Gypsum LLC "DensDeck®Roofboard "or "DensDeck®Prime Roofboard "or "DensDeck®
DuraGuard ™Roofboard "or minimum 1 /4 -in ,thick United States Gypsum Co."SECUROCK®Roof Board "(Type
FRX -G )or "SECUROCK®Glass -Mat Roof Board "(Type SGMRX )in any existing noncombustible roof deck
Classification .
The addition of one ply of "Black Diamond Base Sheet "(self -adhered ),or two fully adhered Type G1 plies (hot
asphalt ),installed as a vapor retarder is allowable in any existing non -combustible deck assemblies that include a
minimum 1 /2 -in thick gypsum board or minimum 1 /4 -in .thick Georgia -Pacific Gypsum LLC "DensDeck®Roofboard "
or "DensDeck®Prime Roofboard "or minimum 1 /4 -in .thick United States Gypsum Co."SECUROCK®Roof Board ".
Unless otherwise indicated ,the following base /ply sheets and the respective method of attachment are
acceptable alternate where a Type G2 product is utilized in any of the following roof covering systems:
Base /Ply Sheets Application Method (s )
2 plies of Type G1 Hot Mopped
"Glasbase Base Sheet "Hot Mopped ,Mechanically Fastened
"Flexiglas Base Sheet"Hot Mopped ,Cold Applied ,Mechanically Fastened
"All Weather /Empire Base Sheet"Hot Mopped ,Cold Applied ,Mechanically Fastened
"Flintlastic Base 20 "Hot Mopped ,Cold Applied ,Mechanically Fastened
"Flintlastic Base 20 T "2,0 Ticar ustu ,vietnamically Tastentu
"Flintlastic APP Base T "2 Heat Fused ,Mechanically Fastened
"Flintlastic Poly SMS Base Sheet "1,5 Hot Mopped ,Cold Applied ,Mechanically Fastened
"Flintlastic Ultra Poly SMS Base Sheet"1 ,2,5 Hot Mopped ,Heat Fused ,Cold Applied ,Mechanically Fastened
"Flintlastic Ultra Glass SA "3 Self -Adhered
"Black Diamond Base Sheet"3 Self -Adhered
"Flintlastic SA NailBase "Self -Adhered
"Flintlastic SA MidPly "4 Self -Adhered
"Flintlastic SA PlyBase "4 Self -Adhered
1Non -combustible roof deck assemblies only .
|2Must be applied only to Certain Teed approved deck ,base sheet or gypsum coverboard when heat fused .
3Must be applied only to Certain Teed approved deck ,base sheet or insulation /coverboard .
4 Must be applied only to Certain Teed approved deck ,base sheet or insulation /coverboard ;"Flintlastic SA Cap "
and "Flintlastic SA Cap FR "membrane assemblies only .
5 Limited to Single Ply Membrane Systems (Modified Bitumen )
Mineral Wool Felt ,is a suitable alternate for perforated Type 15 asphalt organic felt in the Class A ,B or C roof
constructions indicated below .
Unless otherwise indicated ,Base Sheets or Ply Sheets are mechanically fastened ,self -adhered or hot mopped ;Cap
Sheets are hot mopped .
Unless otherwise indicated ,barrier boards and insulation may be mechanically fastened or fully adhered with UL
Classified adhesive .
The "Yosemite Venting Base Sheet "may be used in any of the following noncombustible deck roof systems and ,
where indicated ,in combustible roof deck systems .
"Flintlastic Ultra Poly SMS Base Sheet "may be used in lieu of "Flintlastic Poly SMS Base Sheet "in all applicable
Classifications .
Unless otherwise indicated ,the membranes and their respective alternates in the Table below are interchangeable for
use in roof covering systems limited to a maximum incline of 1/2 :12 :
Membrane Acceptable Alternate
Flintglas MS Cap Flintglas MS Cap CoolStar
Flintlastic GTS Flintlastic GTS CoolStar
Flintlastic GTS -FR Flintlastic GTS -FR CoolStar
Flintlastic Premium FR
Р
Flintlastic FR -Dual Cap ,Flintlastic Premium FR -P CoolStar or Flintlastic FR -Dual Cap
CoolStar
Flintlastic FR Cap 30 T Flintlastic FR Cap 30 T CoolStar
Flintlastic GTA Flintlastic GTA CoolStar
Flintlastic GMS Flintlastic GMS CoolStar
Surfacing:-Gravel.
2.Deck :C -15 /32 Incline :1/2
Insulation :Glass fiber,perlite or wood fiber ,3/4 to 2-1 /2 in .thick ,butt joints in insulation must be offset a
minimum of 6 -in .from joints in roof deck ,mechanically fastened .
Base Sheet :-Type G2 or alternate (see preamble table ).
Membrane :-"Flintlastic STA ","Flintlastic STA Plus "or "Flintlastic GTA ",heat fused .
Surfacing :-Gravel .
3.Deck :C -15 /32 Incline :1/4
Base Sheet :-Type G2 or alternate (see preamble table ).
Membrane :— "Flintlastic STA ","Flintlastic STA Plus "or "Flintlastic GTA ",heat fused .
Surfacing :-Gravel.
4.Deck :C -15 /32 *Incline :1
*All roof deck joints blocked with 2x4's .
Base Sheet:-Type G2 or alternate (see preamble table ).
Membrane :— "Flintlastic GMS ",hot mopped .
Surfacing :-Gravel.
5.Deck :C -15 /32 Incline :1/4
Insulation :— Polyisocyanurate ,minimum 2 -in .thick ,butt joints in insulation must be offset a minimum 6 -in .
from joints in roof deck ,mechanically fastened .
Base Sheet :— Type G2 or alternate (see preamble table ).
Membrane :-"Flintlastic GMS ",hot mopped .
Surfacing:—
Gravel .
6.Deck :C -15 /32 Incline :1/4
Insulation :— Polyisocyanurate ,minimum 2 -in .thick ,butt joints in insulation must be offset a minimum of 6 -in .
from joints in roof deck ,mechanically fastened .
Base Sheet :-Type G2 or alternate (see preamble table ).
Membrane :— "Flintlastic STA ","Flintlastic STA Plus "or "Flintlastic GTA ",heat fused .
Surfacing:-Gravel .
Class A -Fully Adhered
In lieu of any membrane or memerane/surfacing shown below ,"Flintlastic Ultra Poly SMS Base Sheet ",covered with
gravel ,may be utilized .
1.Deck :NC Incline :1
Vapor Retarder (Optional ):— Type G2 or alternate (see preamble table )or UL Classified vapor retarder .
Insulation (Optional ):— Polyisocyanurate ,perlite ,glass fiber or wood fiber,any thickness ,any combination .
Base Sheet :-Type G2 or alternate (see preamble table ).
Membrane :— "Flintlastic GTA "or "Flintlastic GTS ",heat fused ;or "Flintlastic GMS ",hot mopped .
Surfacing :— APOC "APOC 212 AF Aluminum Fiber Roof Coating ",applied at 1-1 /2 gal./100-ft ?.
2.Deck :NC Incline :3/4
Vapor Retarder (Optional ):— Type G2 or alternate (see preamble table )or UL Classified vapor retarder .
Insulation (Optional ):-Polyisocyanurate,perlite ,glass fiber or wood fiber,any thickness ,any combination .
Base Sheet :-Type G2 or alternate (see preamble table ).
Insulation (Optional ):— Perlite ,glass fiber ,polyurethane ,polyisocyanurate ,phenolic combination
isocyanurate /perlite ,polyurethane /perlite or wood fiber ,any thickness ,hot mopped or mechanically fastened .
Membrane :— "Flintlastic STA "or "Flintlastic GTA ",heat fused;or "Flintlastic GMS "hot mopped .
Surfacing:— Grundy Industries ,Inc."al MB Aluminum Roof Coating"applied at 1 to 2-gal./100-ft ?.
10.Deck :C -15 /32 Incline :1/4
Vapor Retarder (Optional ):— Type G2 or alternate (see preamble table )or UL Classified vapor retarder .
Insulation (Optional ):-Polyisocyanurate,glass fiber or perlite ,any thickness ,butt joints in insulation must
be offset minimum 6 -in .from butt joints in the roof deck ,mechanically fastened .
Base Sheet :-Type G2 or alternate (see preamble table ).
Ply Sheet :-Type G2 or alternate (see preamble table ).
Membrane :-"Flintlastic STA ","Flintlastic STA Plus "or "Flintlastic GTA ".
Surfacing :— "FlintCoat -A150 "or "FlintCoat -A300 ",or Karnak Corp."97AF "or "98AF "applied at 1 to 2
golu 100 42
11.Deck :NC Incline :1/2
Insulation (Optional ):— Polyisocyanurate ,glass fiber,perlite or wood fiber,any thickness ,any combination ,
mechanically fastened .
Base Sheet:— Type G2 or alternate (see preamble table ).
Membrane :-"Flintlastic FR -P ","Flintlastic Premium FR -P ","Flintlastic FR -Dual Cap "or "Flintlastic FR Cap
30 ",hot mopped .
TZ .Deck :U -15 /32 "incline :112
*All joints in the roof deck blocked with 2x4's .
Insulation (Optional ):— Polyisocyanurate ,glass fiber or perlite ,any thickness ,any combination ,
mechanically fastened .
Base Sheet :— Type G2 or alternate (see preamble table ).
Membrane :— "Flintlastic FR -P ","Flintlastic Premium FR -P ","Flintlastic FR -Dual Cap "or "Flintlastic FR Cap
30 ",hot mopped .
13.Deck :NC Incline :1/2
Insulation (Optional ):-EPS ,any thickness ,covered with minimum 1 /2 -in .thick perlite or wood fiber,
mechanically fastened .
Base Sheet :— Type G2 or alternate (see preamble table ).
Membrane :-"Flintlastic FR -P ","Flintlastic Premium FR -P ","Flintlastic FR -Dual Cap "or "Flintlastic FR Cap
30 ",hot mopped .
14.Deck :NC Incline :1/2
Insulation :— Polyisocyanurate ,glass fiber ,perlite or wood fiber ,any thickness ,any combination ,
mechanically fastened .
Base Sheet :-Type G2 or alternate (see preamble table ).
Ply Sheet :— "Flintlastic Poly SMS Base Sheet ",hot mopped .
Membrane :-"Flintlastic GMS ",hot mopped .
Surfacing :— "FlintCoat-A150"or "FlintCoat -A300 ",or Karnak Corp."97AF "or "98AF "applied at 2-1 /2
gal./100-ft?
15.Deck :NC Incline :1/4
Insulation (Optional):— Polyisocyanurate ,glass fiber ,perlite or wood fiber,any thickness ,any combination ,
mechanically fastened or hot mopped .
Base Sheet:-Type G2 or alternate (see preamble table ).