HomeMy WebLinkAbout7526-7576 South US 1 - TAS 105Dederal S.p9ineering 8 Q esting, Inc. Dated: 03/25/2021 Paul Bange Roofing 700 SW 21 st Place Davie, FL 33317 Attn: Omar Velazquez RE: Field Withdrawal Resistance Test Prima Vista 7526 - 7576 South US Highway 1 Port St. Lucie, FL 34952 Dear: Sirs: Phone: 954-784-2941 E-Fax: 954-784-7875 admin@fed-eng.com www.fed-eng.com Job Order # 21 RO53 Pursuant to your request, Federal Engineering & Testing, Inc. (FE&T) has performed a field withdrawal resistance test in compliance with Testing Application Standard TAS-105 and the Florida Building Code High Velocity Hurricane Zone at the above referenced site. The purpose of our test was to determine the uplift capacity of the mechanical fasteners at the above referenced project. FE&T is a Miami Dade Certified Testing Laboratory (Certification #18-1105,02). On 01/27/21 our field representative visited the referenced site and conducted thirty-five (35) field withdrawal resistance tests on the Olympic 6" #12 fasteners into a metal deck. All tests were found in compliance with the Florida Building Code and TAS-105. See attached copies of TAS-105 forms with test results. The test results presented reflect the condition of the roof system at the time of the test. These results are time and sample dependent since roof conditions are continuously changing due to exposure to the elements. All tests were conducted according to the Florida Building Code Test Protocol TAS-105 using a calibrated Comten Industries Fastener Tester Model No.DFG 2W2000 (see attached calibration). FE&T is an independent third party providing un-biased testing information and results. FE&T is not affiliated with our client nor do we have any financial interest in the project or determination of the test results. Federal Engineering & Testing, Inc., appreciates the opportunity to be of service to you at this phase of your project. If you have any questions or comments, please give us a call. It has been a pleasure working with you and look forward to doing so in the near future. Digitally signed by Keith LeBlanc, P.E. DN: c=US, st=Florida, 1=Oakland Park, o=Federal •aa So"N 1Fe''*It*, Engineering &Testing, Inc., •°���.� ou=FL Professional :��;• No. 59394 •;C' °= : Engineer #59394, cn=Keith ''o * 0:1 LeBlanc, P.E., STATE OF • 4 �'°.��F••:;�ORIOP•� ?��= email=keith@fed-eng.com 'N:,SEONAL ti� ° Date: 2021.03.25 15:47:31 Oftnus -04'00' Attachments include the following: Field Withdrawal Resistance Test Results Field Sketch Comten Calibration Florida Building Code Test Protocol TAS-105 Building Code Compliance Office Testing Application Standard TAS 105-20 Field Withdrawal Resistance Test Results General Information: Job Name: Prima Vista Job Address: 7526 - 7576 South US Highway 1 Port St. Lucie, FL 34952 Contact Individual at jobsite (if any) Omar Velazquez Testing Agency / Equipment Information: Pederal Q ngineering 8r OQ esting, Inc. Note: The undersigned acknowledges that all testing has been conducted and results have been reported in compliance with Florida Building Code Test Protocol TAS-105 Testing Agency Name: Federal Engineering & Testing Inc. Company Address: 3370 NE 5th Avenue, Oakland Park, FL 33334 Company Telephone: (954) 784-2941 Company Fax: (954) 784-7875 Digitally signed by Keith LeBlanc, P.E. DN: c=US, st=Florida,l=Oakland SoHN 4Fe'••., Park, o=Federal Engineering & Testing Inc. ou=FL Professional No. 59394 Engineer #59394, cn=Keith i� 9�. * 1�. -ST'AATE OF LeBlanc, P.E., email=keith@fed- F '�••,S�ONAL.E, �•`' Date: 2021.03.25 15:47:00-04'00' Testing Apparatus: Comten Industries Fastener Tester Model DFG2W2000 Building / Roof System Information: Area Number: 1 Roof Area Height 17 ft. Roof Area Length - ft. Second Largest Dimension 190 ft. Total Roof Area 35943 ftz 360 sq. Perimeter Area 9058 R' (See RAS 117) Building / Roof System Information: Area Number: Roof Area Height R. Roof Area Length ft. Second Largest Dimension ft. Total Roof Area R' sq. Perimeter Area ft2 (See RAS 117) Building / Roof System Information: Area Number: Roof Area Height R. Roof Area Length ft. Second Largest Dimension ft. Total Roof Area ft' sq. Perimeter Area ft' (See RAS 117) A-,ederagineering esting, Inc. Field Withdrawal Resistance Recording Sheet Component to be secured: ❑ Insulation ❑ Membrane ❑ Anchor or Basesheet ❑ Woodblocking ❑ Metal Profiles ❑ Resistance Verification Only Area Number I aederal gineering esting, inc. (Refer to dock dimensions on Page No. 2) Fastener Type: #12 6" screws Fastener Manufacturer: Olympic Predrilled: Yes ❑ No P1 If Yes, Drill Bit Size: N/A "diameter Hole Depth: N/A See Section 8 to determine number of tests (If drill is hiah tolerance include ranee in 1, I000" tnlrranmt Sample & Plan Identifier Initial Failure Load pbf) Roof Zones 1 612 3 2 672 3 3 555 3 4 623 3 5 363 3 6 699 3 7 957 3 8 932 3 9 614 3 10 614 3 11 579 3 12 624 2 13 655 2 14 635 2 15 1086 2 16 934 2 17 958 2 18 961 2 19 601 2 20 883 2 21 714 2 22 609 2 23 653 1 24 620 1 25 688 1 Sample & Plan Identifier Initial Failure Load (Ibf) Roof Zones 26 715 1 27 577 1 28 746 1 29 716 1' 30 744 1' 31 745 1' 32 683 1' 33 1015 1' 34 653 1' 35 670 1' 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 Fastener Installation Information: Is the fastener a self driller? ❑ Yes ❑ No If yes, list the type of tool used for fastener installation: Speed of tool: Variable rpm's Number of tests conducted: n= 35 . See Section 8 of Test Protocol TAS 105 Note the locations of all tests on "Building Information" Detail 0 I, attached) Cordless Drill Mean Failure Load Sample Standard Deviation Minimum Characteristic Resistance Force Notes F= Sf= F'= 717.29 155.60 Aederal fn-Olgineering esting, Inc. Ibf Ibf 691.84 Ibf " Use of the results herein to determine the required number of fasteners for insulation attachment or an acceptable anchor or base sheet fastener spacing, as outlined in RAS 117, shall utilize the minimum characteristic resistance force (F'), determined in compliance with Section 9 of TAS 105. No margin of safety shall be applied to field withdrawal resistance test results determined in compliance with TAS 105. 2) A safety factor of 2 to 1 shall be applied to all results of laboratory testing. 3) The following pages shall be completed for each roof area and included with all Field Withdrawal Resistance Test Recording Sheets. Roof Area 1 (If no parapet wall exists insert "N/A") N/A 17 Feet Ground Level Buildine Information - Detail 4 1 )-'Cardinal ' Cardinal Scale Manufacturing Co. 1� Products v Solutions for the Weighing Indust?), .......................................... Miami Branch Office • Sales, Service, Rentals CERTIFICATE OF CALIBRATION OWNER OF ITEM: FEDERAL ENGINEERING REPORT NO.: 34234 SCALE TYPE: PUSH/PULL TESTER CALIBRATION DATE: 12/15/20 MANUFACTURER: COMTEN / ASHCROFT RECALIBRATION DUE: MARCH 2O21 MODEL NUMBER: 36 TECHNICIAN: SCOTT SERIAL NUMBER: 21210010 / WT #2 CAPACITY: 2,000 LB PROCEDURE USED: TEST WEIGHT DIVISIONS: 1 LB THIS DOCUMENT CERTIFIES THAT THE ABOVE INSTRUMENT HAS BEEN TESTED AND FOUND TO BE WITHIN 5% OF THE FIRST 500 LB. OF A TEST LOAD AND WITHIN 10% OF A TEST LOAD BETWEEN 501 LB AND 2,000 LB THE STANDARDS USED ARE ALSO TRACEABLE TO THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY (NIST). STANDARDS CALIBRATION DATE: 11/15/2019 FLORIDA STATE CERTIFICATION NO.: 137 CARDINAL • DETECTO Mlami Branch Office: 3215 NW loth Terrace, Suite. 203 • Oakland Park, FL 33309 /�A Phone: (954) 563-4120 Fax: (954) 563-9920 . mismi@cardet.com • www.CardinalSeate.com E %