Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED, Boral Villa 900
Florida �r e F^ sw:�F'3,Ii�yt !sea BCIS Home Log In I User Registration I Hot Topics ( Submit Surcharge j Stats & Facts Publications j Contact Us BCIS Site Map Links Search Product Approval � FUSER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL7849-R13 Application Type Revision Code Version 2020 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Boral Roofing Address/Phone/Email 7575 Irvine Center Drive Suite 100 Irvine, CA 92618 (801) 380-6091 RobinAnderson@boral.com Authorized Signature Anderson Robin RobinAnderson@boral.com Technical Representative Robin Anderson Address/Phone/Email 10701 So. River Front Parkway Suite 300 So. Jordan, UT 84095 (801)380-6091 robinanderson@boral.com Quality Assurance Representative Robin Anderson Address/Phone/Email 7575 Irvine Center Dr. #100 Irvine, CA 92618 (801) 380-6091 robinanderson@boral.com Category Roofing Subcategory Roofing Tiles Compliance Method Evaluation Report from a Product Evaluation Entity Evaluation Entity IAPMO Uniform Evaluation Services LLC. Quality Assurance Entity QAI Laboratories Quality Assurance Contract Expiration Date 12/31/2025 Validated By Gary W. Walker Validation Checklist - Hardcopy Received Certificate of Independence FL7849 R13 COI IAPMO Uniform ES - Certificate of Independence.pdf Referenced Standard and Year (of Standard) Standard Year ASTM C1492 2009 ASTM E108 2016 Equivalence of Product Standards Certified By Shake Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Installation Instructions FL7849 R13 II EBS-Installtion.pdf FL7849 R13 II Florida High Wind Tile Installation Manual - 6th Edition.pdf Verified By: Gary W. Walker 40455 Created by Independent Third Party: Yes Evaluation Reports FL7849 R13 AE UES ER-412.pdf 17849.27 ( Tejas Espana / Barcelona I High Profile - Katy, TX Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Installation Instructions FL7849 R13 II EBS-Installation.pdf FL7849 R13 II Florida High Wind Tile Installation Manual - 6th Edition.pdf Verified By: IAPMO Uniform Evaluation Services LLC. Created by Independent Third Party: Evaluation Reports FL7849 R13 AE UES ER-412.pdf 7849.28 Villa Low Profile - Katy, TX Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure. N/A Other: Installation Instructions FL7849 R13 II EBS-Installation.pdf FL7849 R13 II Florida High Wind Tile Installation Manual - 6th Edition.pdf Verified By: IAPMO Uniform Evaluation Services LLC. Created by Independent Third Party: Evaluation Reports FL7849 R13 AE UES ER-412.pdf 17849.29 I Villa I Low Profile - Phoenix, AZ j Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Installation Instructions FL7849 R13 II EBS-Installation.pdf FL7849 R13 II Florida High Wind Tile Installation Manual - 6th Edition.pdf Verified By: IAPMO Uniform Evaluation Services LLC. Created by Independent Third Party: Evaluation Reports FL7849 R13 AE UES ER-412.pdf 17849.30 I Villa 600 & 900 I Low Profile - Rialto, CA Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Installation Instructions FL7849 R13 II EBS-Installtion.pdf FL7849 R13 II Florida High Wind Tile Installation Manual - 6th Edition.pdf Verified By: Gary W. Walker 40455 Created by Independent Third Party: Yes Evaluation Reports FL7849 R13 AE UES ER-412.pdf 17849.31 ( Villa 600 & 900 I Low Profile - Stockton, CA 1 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: 1�(� 7849.32 Villa 900 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Installation Instructions FL7849 R13 II EBS-Installtion.pdf FL7849 R13 II Florida High Wind Tile Installation Manual - 6th Edition.pdf Verified By: Gary W. Walker 40455 Created by Independent Third Party: Yes Evaluation Reports FL7849 R13 AE UES ER-412.pdf Low Profile - Lake Wales, FL Installation Instructions FL7849 R13 II EBS-Installtion.pdf FL7849 R13 II Florida High Wind Tile Installation Manual - 6th Edition.pdf Verified By: Gary W. Walker 40455 Created by Independent Third Party: Yes Evaluation Reports FL7849 R13 AE UES ER-412.pdf 17849.33 I Villa 900 1 Low Profile - Stockton, CA Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Installation Instructions FL7849 R13 II EBS-Installation.pdf FL7849 R13 II Florida High Wind Tile Installation Manual - 6th Edition.pdf VE Originally Issued: 07/31/2015 BORAL ROOFING 7575 Irvine Center Drive, Suite 100 Irvine, California 92618 (949) 756-1605 www.boralamerica.com CONCRETE ROOF TILES CSI Section: 07 32 16 Concrete Roof Tiles 1.0 RECOGNITION Revised: 08/21/2020 Valid Through: 07/31/2021 3.0 PRODUCT USE Boral Roofing Concrete Roof Tiles recognized in this report have been evaluated for use as concrete roof tiles. The weather resistance, wind uplift resistance and fire classification properties of the roof tiles comply with the intent of the provisions of the following codes and regulations: • 2018, 2015, 2012, 2009, and 2006 International Building Code® (IBC) • 2018, 2015, 2012, 2009, and 2006 International Residential Code® (IRC) • 2019 California Building Code (CBC) —Supplement attached • 2019 California Residential Code (CRC) — Supplement attached • 2020 Florida Building Code, Building (FBC, Building) — Supplement attached • 2020 Florida Building Code, Residential (FBC, Residential) — Supplement attached 2.0 LINHTATIONS Use of the Boral Roofing Concrete Roof Tiles recognized in this report is subject to the following limitations: 2.1 The roof tiles shall be manufactured, identified and installed in accordance with this report and the applicable code. In the event of a conflict this report governs. 2.2 Boral Roofing "concrete roof rile shall be installed on roof slopes of 2%2 units vertical in 12 units horizontal (21- percent slope) or greater." IBC Section 1507.3.2. 2.3 The supporting structure shall be designed to support the loads and is beyond the scope of this report. 2.4 The Concrete Roof Tiles recognized in this report are produced in Lake Wales, FL; Brookshire, TX; Phoenix, AZ; Henderson, NV; Okeechobee, FL, Rialto, CA; French Camp, CA; Henderson, CO and Lathrop, CA; Tables 2 A through 2 I describe the tiles produced at each location. 3.1 General: Boral Roofing Concrete Roof Tiles shall be used as a roof covering in accordance with IBC Section 1503 or IRC Section 903, as applicable. 3.2 Installation: 3.2.1 Installation when installed in accordance with the requirements of the 2018 IBC or IRC: Boral Concrete Roof Tile shall be installed in accordance with 2018 IBC Section 1507.3 or 2018 IRC Section R905.3, including the attachment requirements of 2018 IBC Section 1507.3.7 or 2018 IRC Section R905.3.7, as applicable. Underlayment shall conform to 2018 IBC Section 1507.1.1 or 2018 IRC Section R905.1.1 3.2.2 Installation when the 2015, 2012, 2009 or 2006 IBC or IRC is applicable: Boral Concrete Roof Tile shall be fastened in accordance with The Concrete and Clay Roof Tile Installation Manual for Moderate Climate Regions, dated July 2015, published by the Tile Roofing Institute and the Western States Roofing Contractors Association, and this report.. The TRI manual is available for download attached to ER-2015 from the UES website at www.uniform-es.ora. The Concrete Roof Tile shall be attached to the roof structure based on the applicable code and criteria for applicability as noted in Table 1 of this report. TABLE 1—ATTACHMENT DESIGN Applicable Design Code Criteria for Applicability Information Location Ultimate Design Wind 2015 or 2012 Speeds (V,10:5 130 MPH Roof Tile IBC and Mean Roof Height < 60 Installation feet Manual & Table 1507.3.7 of the Basic Wind Speed (3 sec 2009 or 2006 gust) < 100 mph and Mean applicable IBC IBC Roof Hei t < 60 feet Roof Tile 2015, 2012, Mean Roof Height:5 40 feet Installation 2009 or 2006 Manual & Section IRC R905.3.7 For SI: 1 foot = 305 nun, 1 mph = 1.6 m/s 3.4 Anchoring: Boral Concrete Roof tile may be anchored by mortar in accordance with the applicable building code and, where permitted, the TRI Manual or adhesively attached in accordance with the adhesive manufacturer's research report issued by an approved evaluation service agency. The product described in this Uniform Evaluation Service (LIES) Report has been evaluated as an alternative material, design or method of construction in order to satisfy and comply with the intent of the provision of the code, as noted in this report, and for at least equivalence to that prescribed in the code in quality, strength, effectiveness, fire resistance, durability and safety, as applicable, in accordance with IBC Section 104.11. This document shall only be reproduced in its enfirety. Copyright © 2020 by International Association of Plumbing and Mechanical Officials. All rights reserved. Printed in the United States. Ph: 1-877-41ESRPT • Fax: 909.472.4171 web: www.uniform-es.org • 4755 East Philadelphia Street Ontario, California 91761-2816 — USA Page 1 of 7t q Originally Issued: 07/31/2015 Revised: 08/21/2020 Valid Through: 07/31/2021 4.0 PRODUCT DESCRIPTION Boral Roofing Concrete Roof Tiles comply with ASTM C1492 as required by Section 1507.3.5 of the IBC. The roof tiles are described by model, weight, dimensions, and tile factor in Tables 2 A through 2 I, for each of the production locations listed in Section 2.4 of this report. When installed in accordance with this report on minimum 15/32 inch thick (12 mm) plywood solid sheathing or non-combustible decks, the assembly incorporating the roof tiles achieve an ASTM E108 Class A rating per Section 1505.2 of the IBC and Section R902.1 of the IRC, as applicable. Roof classifications for adhesively attached systems shall be in accordance with the adhesive manufacturer's approved research report. 5.0 IDENTIFICATION Shipping pallets are identified with the report holder's name (Boral Roofing), manufacturing address, product name, installed weight, inspection agency, and evaluation report number (ER-412). The Cedarlite 600, Madera 700 and Madera 900 tiles are imprinted on the top side of each tile with an "M", all other filed tiles are imprinted with the name `Boral", "Boral Lifetile", "Monierlifetile", or the Boral Roofing, or MonierLifetile or "Vostile" or logo. The identification includes the IAPMO Uniform Evaluation Service Mark of Conformity. Either Mark of Conformity may be used as shown below: IAPMO UES ER-412 6.0 SUBSTANTIATING DATA Data in accordance with ICC-ES AC180, dated February 2012 (editorially revised March 2018), manufacturer's descriptive literature and installation instructions. Test reports are from laboratories in compliance with ISO/IEC 17025. 7.0 STATEMENT OF RECOGNITION This evaluation report describes the results of research carried out by IAPMO Uniform Evaluation Service on Boral Roofing Concrete Roof Tiles to assess conformance to the codes shown in Section 1.0 of this report and serves as documentation of the product certification. Products are manufactured at locations noted in Section 2.4 of this report under a quality control program with periodic inspection under the supervision of IAPMO UES. Brian Gerber, P.E., S.E. Vice President, Technical Operations Uniform Evaluation Service Richard Beck, PE, CBO, MCP Vice President, Uniform Evaluation Service GP Russ Chan y CEO, The IAPMO Group For additional information about this evaluation report please visit www.uniform-es.ore or email us at infoAuniform-es.ore Page 2 of 7 0 Originally Issued: 07/31/2015 Revised: 08/21/2020 Valid Through: 07/31/2021 Table 2 D - Tiles Manufactured at Lake Wales, FL Tile Installed D I'3' Weights (psf) Dimemsions2 inch Tile Factor Length X Width TF (ft3) Ratio 1 Barcelona 900 9.5 17 X 13 1.525 1.084 Saxony 900 -Shake, Slate, Split Shake, Country Slate 9.5 17 X 13 1.545 1.098 Spanish "S" Nuevo 9.9 17 X 93/4 1.144 0.813 Villa 900 9.2 17 X 13 1.533 1.090 For SI: 1 inch = 25.4 mm, 1 psf = 4.88 kg/m2 Table 2 E - Tiles Manufactured at Lathrop, CA Tile Dry Installed D Weights (psf) Dimemsions2 inch Tile Factor Length X Width TF (ft3) Ratio i Barcelona 900 9.3 17 X 13 1.509 1.073 Saxon 900 — Shake, Slate 1 9.1 17 X 13 1.533 1.090 For SI: 1 inch = 25.4 mm, 1 psf = 4.88 kg/m` Table 2 F - Tiles Manufactured at Phoenix, AZ Tile Installed D I'3' Weights (psf) Dimemsions2 inch Tile Factor Length X Width TF (ft3) Ratio I Mission S / Barcelona 10.3 16'/2 X 13 1.494 1.062 Saxon — Shake, Slate 9.5 16%2 X 13 1 1.494 1.062 Villa 9.0 161/2 X 13 1 1.407 1.000 For SI: 1 inch = 25.4 mm, 1 psf = 4.88 kg/m` Table 2 G - Tiles Manufactured at Okeechobee, FL Tile Installed D s'Y Weights (psf) Dimemsions2 inch Tile Factor Length X Width TF (ft3) Ratio I Bermuda 12.44 161/s X 101/8 1.036 0.736 Estate "S" 7.9 16%2 X 13 1.417 1.007 Galena Spanish "S" 9.3 17 X 10 1.144 0.831 Plantation 10.4 161/z X 13 1.426 1.014 Saxony 900 9.3 17 X 13 1.533 1.090 For SI: I inch = 25.4 mm, 1 psf = 4.88 kg/m` NOTES TO TABLES: 1. Used on a 3-inch head -lap. 2. Nominal dimension. Page 4 of 7 Originally Issued: 07/31/2015 Revised: 08/21/2020 CALIFORNIA SUPPLEMENT BORAL ROOFING 7575 Irvine Center Drive, Suite 100 Irvine, California 92618 (949) 756-1605 www.boralamerica.com CONCRETE ROOF TILES CSI Section: 07 32 16 Concrete Roof Tiles 1.0 RECOGNITION The Boral Concrete Roof Tiles evaluated in IAPMO UES ER-412 is a satisfactory alternative to the following codes and regulations: • 2019 California Building Code (CBC) • 2019 California Residential Code (CRC) 2.0 PRODUCT USE 2.1 The Boral Roofing concrete roof tiles may be used as a Class A, B, or C roof covering systems complying with Sections 1505.1.1 of the CBC or R902.1.1 of the CRC; Sections 1505.1.2 of the CBC or R902.1.2 of the CRC; or Sections 1505.1.3 of the CBC or R902.1.3 of the CRC, respectively. The design and installation of the Boral Roofing concrete roof tiles shall be in accordance with Sections 1507.3.10 and 1513 CBC or Section 905.3 of the CRC, as applicable, and ER-412. 2.2 Roof Tiles shall be installed in accordance with Sections 3.0 and 4.0 of ER-412 except, where the building official requires conformance to the CBC or CRC, the following shall be substituted: 2.2.1 Underlayment shall conform with CBC Section 1507.1.1 or CRC Section 905.1.1. 2.2.2 Attachment of the concrete roof tiles shall be designed to resist wind loads according to CBC Sections 1507.3.7 and 1609.5 or CRC Section 905.3, as applicable. 2.3 Boral Roofing concrete roof tiles may be used in "new buildings located in any Fire Hazard Severity Zone or any Wildland-Urban Interface Fire Area designated by the enforcing agency constructed after the application date shall comply with the provisions" in accordance with Sections 701A.3 and 705A of the CBC, or Sections R337.1.3.1 and R337.5 of the CRC, as applicable, and with the IBC as presented in ER-412. Valid Through: 07/31/2021 2.4 Boral Roofing concrete roof tiles used on structures regulated by the Division of the State Architect or the Office of Statewide Planning and Development are subject to installation provisions in CBC Section 1513. For additional information about this evaluation report please visit www.uniform-es.ora or email us at infoaa,uniform-es.ore Page 6 of 7 Originally Issued: 07/31/2015 Revised: 08/21/2020 FLORIDA SUPPLEMENT BORAL ROOFING 7575 Irvine Center Drive, Suite 100 Irvine, California 92618 (949) 756-1605 www.boralamerica.com CONCRETE ROOF TILES CSI Section: 07 32 16 Concrete Roof Tiles 1.0 RECOGNITION The Boral Roofing concrete roof tiles evaluated in 1APM0 UES ER412 is a satisfactory alternative to the following codes and regulations: • 2020 Florida Building Code, Building (FBC, Building) • 2020 Florida Building Code, Residential (FBC, Residential) 2.0 LEWTATIONS 2.1 Verification shall be provided that a quality assurance agency audits the manufacturers quality assurance program and audits the production quality of products, in accordance with Section (5)(d) of Florida Rule 61G20-3.008. The quality assurance agency shall be approved by the Commission (or the building official when the report holder does not possess an approval by the Commission). 2.2 Evaluation to the high -velocity hurricane zone provisions in Section 1512 of the FBC, Building and Chapter 44 of the FBC, Residential is beyond the scope of this report. 3.0 PRODUCT USE The design and installation of the Boral Roofing concrete roof tiles shall be in accordance with the 2018 International Building Code and the 2018 International Residential Code, as applicable, as noted in ER-412. From FBC, Building Section 1507.3 and FBC, Residential Section R905.3 states that the installation of the Boral Roofing concrete roof tiles "shall be in accordance with the requirements of the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition where the Vad is determined in accordance with" FBC, Building Section 1609.3.1, FBC-Residential Section R301.2.1.3, or the recommendations of RAS 118, 119 or 120. Load combinations shall be in accordance with Sections 1605.2 or 1605.3 of the FBC, Building, as applicable. Design wind Valid Through: 07/31/2021 loads shall be in accordance with Section 1609.5 of the FBC, Building or Section R301.2.1 of the FBC, Residential, as applicable. For additional information about this evaluation report please visit www.uniform-es.ora or email us at infoCa,uniform-es.ore Page 7 of 7