HomeMy WebLinkAboutAPPROVED FL9520_R8_II_CWS-836C installations 3" PVCMULL BARIMPACTCWS-836 CADE09/27/12 SHEET DESCRIPTION: DRAWN BY: DATE: DWG #: REV.: SCALE:1:25SHEET1 OF 10LUCAS A. TURNER, P.E.FL PE # 582012428 Old Natchez Trc TrlCamden, TN 38320PH. 941-380-15741900 SW 44TH AVE.OCALA, FLORIDA 34474WWW.CWS.CCPROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED INTHIS DRAWING IS THE SOLEPROPERTY OF CUSTOM WINDOWSYSTEMS, INC. ANYREPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTENPERMISSION OF CUSTOM WINDOWSYSTEMS, INC IS PROHIBITED.GENERAL NOTES:1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE FLORIDA BUILDING CODE (FBC), CURRENT EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ) AND IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED IN ASTM E 1996 PER THE FBC.2. CONFIGURATIONS (SEE SHEETS 2-3): VERTICAL OR HORIZONTAL.3. SEE MULLION CHARTS FOR MAX. DESIGN PRESSURES AND LENGTH. (REFER TO SHEETS 2-3)4. ANCHORAGE: THE 33 1/3% STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. SEE SHEETS 9-10 FOR ANCHOR DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS.5. PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT REQUIRED.6. DESIGN PRESSURE OF MULLED UNITS SHALL BE CONTROLLED BY THE LESSER DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL WINDOW UNITS.7. DESIGN PRESSURES AND INSTALLATION DETAILS SHOWN IN THIS DOCUMENT APPLY ONLY TO THE MULLION. WINDOWS MUST BE APPROVED UNDER SEPARATE APPROVAL.8. RESPONSIBILITY OF SELECTING FENESTRATION PRODUCTS TO MEET ANY APPLICABLE LOCAL LAWS, BUILDING CODES, ORDINANCES OR OTHER SAFTEY REQUIREMENTS RESTS SOLEY WITH THE ARCHITECT, ENGINEER OF RECORD, BUILDING OWNER OR CONTRACTOR.9. SINGLE UNITS TO BE MULLED ARE NOT LIMITED TO THOSE SHOWN IN THIS DRAWING. SINGLE UNITS TO BE MULLED TOGETHER MUST BE MANUFACTURED BY CUSTOM WINDOW SYSTEMS, INC. AND MUST BE MADE OUT OF VINYL PVC OR EXTRUDED ALUMINUM.10. VERTICAL MULLED UNITS MAY BE MULLED INDEFINITELY AS LONG AS THE SINGLE UNIT WIDTH AND HEIGHT ARE NOT EXCEEDED, AND MULLIONS ARE ANCHORED AS SHOWN HERE IN.11. HORIZONTAL MULLION SHALL EXTEND THE ENTIRE WIDTH OF THE MULLED UNIT. VERTICAL MULLION IS USED TO MULL SIDE BY SIDE UNITS TOGETHER.GENERAL NOTES ANDELEVATIONS TABLE OF CONTENTSGENERAL NOTES & ELEVATIONS...............1DP CHARTS.................................................2-3BOM & EXTRUSIONS.....................................4EXTRUSIONS.................................................5SECTION VIEWS.........................................6-7CONFIGURATIONS & ANCHOR NOTES.......8INSTALLATION DETAILS..........................9-103" PVC MULL BAR - LARGE MISSILE IMPACTSHOWN w/DIFFERENT OPTIONSXOXOEXAMPLE VERTICAL MULLION FORPVC WINDOWS FOR SECTION VIEWS ONLYANCHOR CLIPANCHOR CLIPXOXOXOOEXAMPLE HORIZ/.VERT. MULLIONFOR SECTION VIEW ONLYANCHOR CLIPANCHOR CLIPA6B6C7D9E9F10ANCHOR CLIPG1008/06/2020Lucas Turner 2020.08.10 12:04:15 -05'00'
3" PVCMULL BARIMPACTCWS-836 CADE09/27/12 SHEET DESCRIPTION: DRAWN BY: DATE: DWG #: REV.: SCALE:1:1SHEET2 OF 10LUCAS A. TURNER, P.E.FL PE # 582012428 Old Natchez Trc TrlCamden, TN 38320PH. 941-380-15741900 SW 44TH AVE.OCALA, FLORIDA 34474WWW.CWS.CCPROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED INTHIS DRAWING IS THE SOLEPROPERTY OF CUSTOM WINDOWSYSTEMS, INC. ANYREPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTENPERMISSION OF CUSTOM WINDOWSYSTEMS, INC IS PROHIBITED.DP CHARTSNON-INTERSECTEDMULLSDP CHART IS FOR:NON-INTERSECTED IMPACT 3" MULLION 1758, HORIZONTAL OR VERTICAL, USING (PER END): 1522 CLIPS - (4) #10 SCREWS INTO WOOD or METAL - (4) 3/16" ITW TAPCONS or ELCO ULTRACONS INTO SOLID CONCRETE or WOOD - (4) 1/4" ELCO ULTRACONS INTO HOLLOW or GROUT-FILLED BLOCK39 45 51 57 63 69 75 3/8 81 87 93 99 107 3/8 114 120 126 132 138 145 3/83780.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.042 3/480.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.048 3/480.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 65.053 1/880.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 65.0 65.0 65.05780.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 65.0 65.0 65.06380.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 78.9 76.6 74.8 72.5 65.0 65.06565.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.06865.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 63.57265.0 65.0 65.0 65.0 65.0 65.0 65.0 64.9 61.7 59.1 56.9 53.7Design Pressure Chart (PSF) for NON-INTERSECTED Impact PVC 3" Mullion H-1758, with 1522 clips using four (4) #10 Screws into WOOD or METAL or 3/16" ITW Tapcons or ELCO ULTRACONS into SOLID CONCRETE or WOOD per each end of mullion. HOLLOW or GROUT-FILLED BLOCK require 1/4" ELCO ULTRACONS.OPENING SIZE (in.)MULL LENGTH (in.)39 45 51 57 63 69 75 3/8 81 87 93 99 107 3/8 114 120 126 132 138 145 3/83780.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.042 3/480.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.048 3/480.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 65.053 1/880.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 65.0 65.0 65.05780.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 65.0 65.0 65.06380.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 65.0 65.06565.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.06865.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.07265.0 65.0 65.0 65.0 65.0 65.0 65.0 64.9 61.7 59.1 56.9 53.7OPENING SIZE (in.)MULL LENGTH (in.)Design Pressure Chart (PSF) for NON-INTERSECTED Impact PVC 3" Mullion H-1758, with 1776 clips with six (6) #10 Screws into WOOD or METAL or 3/16" ITW Tapcons or ELCO ULTRACONS into SOLID CONCRETE or WOOD per each end of mullion. HOLLOW or GROUT-FILLED BLOCK require 1/4" ELCO ULTRACONS.DP CHART IS FOR:NON-INTERSECTED IMPACT 3" MULLION 1758, HORIZONTAL OR VERTICAL, USING (PER END): 1776 CLIPS - (6) #10 SCREWS INTO WOOD or METAL - (6) 3/16" ITW TAPCONS or ELCO ULTRACONS INTO SOLID CONCRETE or WOOD - (6) 1/4" ELCO ULTRACONS INTO HOLLOW or GROUT-FILLED BLOCKOPENING SIZEMULL LENGTHOPENING SIZEMULL LENGTHMULL LENGTHOPENING SIZEOPENING SIZEMULL LENGTHTRANSOM OVER TWINVERTICAL MULLIONTRANSOM OVER TRIPLEVERTICAL MULLIONTWINVERTICAL MULLIONTRIPLEVERTICAL MULLIONMULL LENGTHMULL LENGTHOPENING SIZEMULL LENGTHOPENING SIZEOPENING SIZETWINHORIZONTAL MULLIONTRIPLEHORIZONTAL MULLIONTWIN/TRIPLEHORIZONTAL MULLIONNOTES:1. THE MULL BAR IN FOCUS FOR ANY GIVEN CONFIGURATION IS SHOWN IN BOLD.2. AN INTERSECTED MULL BAR HAS OTHER MULL BAR(S) ATTACHED TO IT (SHOWN IN DASHES) THROUGH THE USE OF MULL BAR CLIPS. AN INTERSECTED MULL BAR WILL ALWAYS BE ATTACHED TO THE SUBSTRATE AT BOTH ENDS.3. NON-INTERSECTED MULL BARS CAN BE ATTACHED TO THE SUBSTRATE AND OTHER MULL BARS.08/06/2020
3" PVCMULL BARIMPACTCWS-836 CADE09/27/12 SHEET DESCRIPTION: DRAWN BY: DATE: DWG #: REV.: SCALE:1:1SHEET3 OF 10LUCAS A. TURNER, P.E.FL PE # 582012428 Old Natchez Trc TrlCamden, TN 38320PH. 941-380-15741900 SW 44TH AVE.OCALA, FLORIDA 34474WWW.CWS.CCPROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED INTHIS DRAWING IS THE SOLEPROPERTY OF CUSTOM WINDOWSYSTEMS, INC. ANYREPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTENPERMISSION OF CUSTOM WINDOWSYSTEMS, INC IS PROHIBITED.DP CHART IS FOR:INTERSECTED IMPACT 3" MULLION 1758, HORIZONTAL OR VERTICAL, USING EITHER (PER END): 1522 CLIPS - (4) #10 SCREWS INTO WOOD or METAL - (4) 3/16" ITW TAPCONS or ELCO ULTRACONS INTO SOLID CONCRETE or WOOD - (4) 1/4" ELCO ULTRACONS INTO HOLLOW or GROUT-FILLED BLOCK 1767 CLIPS - (6) #10 SCREWS INTO WOOD or METAL - (6) 3/16" ITW TAPCONS or ELCO ULTRACONS INTO SOLID CONCRETE or WOOD - (6) 1/4" ELCO ULTRACONS INTO HOLLOW or GROUT-FILLED BLOCKDP CHARTINTERSECTED MULLSMULL LENGTHOPENING SIZESINGLE TWINORTRIPLEUNITSBELOWHORIZONTAL MULLIONMULL LENGTHOPENING SIZETWIN/TRIPLEVERTICAL MULLIONNOTES:1. THE MULL BAR IN FOCUS FOR ANY GIVEN CONFIGURATION IS SHOWN IN BOLD.2. AN INTERSECTED MULL BAR HAS OTHER MULL BAR(S) ATTACHED TO IT (SHOWN IN DASHES) THROUGH THE USE OF MULL BAR CLIPS. AN INTERSECTED MULL BAR WILL ALWAYS BE ATTACHED TO THE SUBSTRATE AT BOTH ENDS.3. NON-INTERSECTED MULL BARS CAN BE ATTACHED TO THE SUBSTRATE AND OTHER MULL BARS.39 45 51 57 63 69 75 3/8 81 87 93 99 110 3/8 114 120 126 132 138 145 3/83750.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.042 3/450.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.048 3/450.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.053 1/850.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.05750.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 48.16350.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 49.4 47.36850.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 49.8 47.67250.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 45.4 44.075.37550.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 46.8 44.0 40.0Design Pressure Chart (PSF) for INTERSECTED Impact PVC 3" Mullion H-1758, with 1522 clips using four (4) #10 Screws into WOOD or METAL or 3/16" ITW Tapcons into SOLID CONCRETE or WOOD, or 1776 clips with six (6) #10 Screws into WOOD or METAL or 3/16" ITW Tapcons into SOLID CONCRETE or WOOD per each end of mullion. HOLLOW or GROUT-FILLED BLOCK require 1/4" ELCO ULTRACONS.OPENING SIZE (in.)MULL LENGTH (in.)08/06/2020
3" PVCMULL BARIMPACTCWS-836 CADE09/27/12 SHEET DESCRIPTION: DRAWN BY: DATE: DWG #: REV.: SCALE:1:2SHEET4 OF 10LUCAS A. TURNER, P.E.FL PE # 582012428 Old Natchez Trc TrlCamden, TN 38320PH. 941-380-15741900 SW 44TH AVE.OCALA, FLORIDA 34474WWW.CWS.CCPROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED INTHIS DRAWING IS THE SOLEPROPERTY OF CUSTOM WINDOWSYSTEMS, INC. ANYREPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTENPERMISSION OF CUSTOM WINDOWSYSTEMS, INC IS PROHIBITED.ITEM PART # DESCRIPTION1 H-1758 1 3/8" x 3" MULLION TUBE2 #10 OR #12 HEX WASHER HEAD TEK SCREW *(see note below)3 #10 x 1 1/2", PANHEAD PHILIPS ZINC4 #10 FLAT WASHER7 S-1897 MULLION CLIP, INTERSECTING8 SEALANT9 S-1895 DRIP CAP, HORZ, FLG10 S-1896 FLANGE ADAPTER, VERT, FLG11 S-6018 MULLION INTERIOR COVER, EXT, FIN/BOX14 F-1522-013 3" SLOTTED NEW CONTRUCTION FIN MULL CLIP15 F-1522-006 3" SLOTTED T-CLIP, FLG/BOX16 F-1767-001 L-ANGLE 3" MULL CLIP, STANDARD, FLG/BOX17 F-1767-004L L-ANGLE 3" MULL CLIP, FIN, LEFT18 F-1767-004R L-ANGLE 3" MULL CLIP, FIN, RIGHT19 #10 HEX WASHER HEAD TEK SCREW20 #10 FH TEK SCREW4 1/8"1 3/16"2 7/16"1 3/4"1 3/8"5/8"1 13/16"9/32"9/32"1 7/16"1 7/16"O1/4"(TYP)1 13/16"1/4"7/16"3/8"3/8"1 11/16"7/16"1 5/16"4 7/8"1/8"2 1/4"2 3/16"1/8"4 7/8"F- 1522 - 013 NEW CONSTRUCTION / FIN INSTALLATIONF-1522-006RETRO / FLANGE CLIP14152 7/16"MULLION INTERIORCOVER S-60181 3/4"7/16"1/16"1 3/8"2 13/16"MULLION CLIP S-18971 3/16"2 1/16"FLANGE ADAPTER S-18961 1/4"1/2"DRIP CAP S-189511/16"1/2"TOP VIEW* USE WOOD SCREW SIZE (#10 OR #12), SPECIFIED IN WINDOW UNIT APPROVAL DOCUMENT13/16"3" MULLBAR H-175811101/16"91/16"11/8"71/8"FRAME TYPE OPENING"T" MULLBAR CLIP(F-1522-XXX)"L" MULLBAR CLIP(F-1767-XXX)NEW F-1522-013F-1767-001RETRO F-1522-006F-1767-001NEW F-1522-013 F-1767-004(L&R)RETRO F-1522-013 F-1767-004(L&R)NEW NOT RECOMMENDED F-1767-001RETRO F-1522-006F-1767-001FLANGEFINBOXBOM AND EXTRUSIONSNOTE: ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED.1 15/16"1 7/8"LINE ITEMS NOT USED:5-6, 12DETAIL A3:1SCORE, BEND AND BREAKTO REMOVE FIN FOR FRAMEATTACHMENT TO MULL BARTYP. FIN FRAMEA08/06/2020
3" PVCMULL BARIMPACTCWS-836 CADE09/27/12 SHEET DESCRIPTION: DRAWN BY: DATE: DWG #: REV.: SCALE:1:2SHEET5 OF 10LUCAS A. TURNER, P.E.FL PE # 582012428 Old Natchez Trc TrlCamden, TN 38320PH. 941-380-15741900 SW 44TH AVE.OCALA, FLORIDA 34474WWW.CWS.CCPROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED INTHIS DRAWING IS THE SOLEPROPERTY OF CUSTOM WINDOWSYSTEMS, INC. ANYREPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTENPERMISSION OF CUSTOM WINDOWSYSTEMS, INC IS PROHIBITED."L" ANGLE 3" STANDARD MULL CLIP - F-1767-0016 7/8"3"1/8"3/8" (2X)1/4" THRU (TYP)7/16" THRU (TYP)16OUTSIDE2 7/16"2 3/4"1718OUTSIDE1 5/8"1/2"2 1/4""L" ANGLE 3" MULL CLIP, FIN (RIGHT) F-1767-004R"L" ANGLE 3" MULL CLIP, FIN (LEFT) F-1767-004L3/8"1 5/8"3/8"1 5/8"1/2"2 3/4"5"1/2"2 3/4"5"7/16" (TYP)1/4" (TYP)EXTRUSIONSFRAME TYPE OPENING"T" MULLBAR CLIP(F-1522-XXX)"L" MULLBAR CLIP(F-1767-XXX)NEW F-1522-013F-1767-001RETRO F-1522-006F-1767-001NEW F-1522-013 F-1767-004(L&R)RETRO F-1522-013 F-1767-004(L&R)NEW NOT RECOMMENDED F-1767-001RETRO F-1522-006F-1767-001FLANGEFINBOX2 3/4"2 3/4"08/06/2020
3" PVCMULL BARIMPACTCWS-836 CADE09/27/12 SHEET DESCRIPTION: DRAWN BY: DATE: DWG #: REV.: SCALE:1:2SHEET6 OF 10LUCAS A. TURNER, P.E.FL PE # 582012428 Old Natchez Trc TrlCamden, TN 38320PH. 941-380-15741900 SW 44TH AVE.OCALA, FLORIDA 34474WWW.CWS.CCPROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED INTHIS DRAWING IS THE SOLEPROPERTY OF CUSTOM WINDOWSYSTEMS, INC. ANYREPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTENPERMISSION OF CUSTOM WINDOWSYSTEMS, INC IS PROHIBITED.A6HORIZONTAL MULL BAR SECTIONFLANGE FRAME WINDOWB6VERTICAL MULL BAR SECTIONFLANGE FRAME WINDOWSEAL BEHIND FLANGEPRIOR TO ATTACHINGTO MULLIONSEAL BEHIND FLANGEPRIOR TO ATTACHINGTO MULLION9110 (SEE DETAIL B)122DETAIL ADETAIL BAPPLY SEALANT ALONG FULL LENGTH OF MULLBAR GROOVE PRIOR TO ATTACHING DRIPADAPTORAPPLY SEALANT ALONG FULL LENGTH OF MULLBAR GROOVE PRIOR TO ATTACHING FLANGEADAPTOR11910FIN MUST BE REMOVEDWHERE WINDOWSCONNECT TO MULLB6VERTICAL MULL BAR SECTIONFIN FRAME WINDOWSEAL BEHIND FLANGEPRIOR TO ATTACHINGTO MULLION1110 (SEE DETAIL B)121111A6HORIZONTAL MULL BAR SECTIONFIN FRAME WINDOWSEAL BEHIND FLANGEPRIOR TO ATTACHINGTO MULLION91211A6VERTICAL/HORIZONTAL MULL BAR SECTIONBOX FRAME WINDOW111211APPLY SEALANT ALONG FULL LENGTH OF WINDOW FRAME GROOVE PRIOR TO ATTACHING COVERFIN MUST BE REMOVEDWHERE WINDOWSCONNECT TO MULLSECTION VIEWSMULLS08/06/2020
3" PVCMULL BARIMPACTCWS-836 CADE09/27/12 SHEET DESCRIPTION: DRAWN BY: DATE: DWG #: REV.: SCALE:1:2SHEET7 OF 10LUCAS A. TURNER, P.E.FL PE # 582012428 Old Natchez Trc TrlCamden, TN 38320PH. 941-380-15741900 SW 44TH AVE.OCALA, FLORIDA 34474WWW.CWS.CCPROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED INTHIS DRAWING IS THE SOLEPROPERTY OF CUSTOM WINDOWSYSTEMS, INC. ANYREPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTENPERMISSION OF CUSTOM WINDOWSYSTEMS, INC IS PROHIBITED.C74" HORIZ. TO 3" VERT. MULLBAR SECTIONFLANGE FRAME WINDOWC75" HORIZ. TO 3" VERT. MULLBAR SECTIONFLANGE FRAME WINDOW295" MULLBAR (H-1760)(SEE SEPARATE APPROVAL FOR APPROPRIATE DP CHARTS)7SEE NOTE 12C73" HORIZ. TO 3" VERT. MULLBAR SECTIONFLANGE FRAME WINDOW297SEE NOTE 17SEE NOTE 1914" MULLBAR (H-1759)(SEE SEPARATE APPROVAL FOR APPROPRIATE DP CHARTS)TOP VIEWFIN FRAME171718119 SEE NOTES 1 & 211119 SEE NOTES 1 & 219 SEE NOTES 1 & 2NOTES:1. SLIDE CLIP INTO LOCATION AND SECURE WITH ITEMS 19 (QTY 1) AND 20 (QTY 1), AS SHOWN ABOVE.2. PRE-DRILLED HOLES (THRU H/V CLIP 1897), BY THE INSTALLER, MAY BE LOCATED AS NEEDED WHILE MAINTAINING A MINIMUM CLIP EDGE DISTANCE OF 9/32" AND A MINIMUM CENTER TO CENTER SPACING OF 1/2".3. THE ABOVE SECTIONS APPLY TO ALL MULLBAR-TO-MULLBAR CONNECTIONS, REGARDLESS OF ORIENTATION (i.e., HORIZONTAL OR VERTICAL). THE FULL LENGTH MULL MUST BE THE SAME DEPTH, OR GREATER, THAN THE INTERSECTING MULL.4. INTERIOR MULL ANCHOR ATTACHMENT SCREW THRU VERTICAL MULL INTO MULL CLIP. PRE-DRILL PILOT HOLE THRU ALL MATERIAL.(1 EA./CLIP)(1 EA./CLIP)(1 EA./CLIP)SECTION VIEWSMULL INTERSECTIONS11/16"MAX. EDGE DISTANCE20SEE NOTE 420SEE NOTE 420SEE NOTE 411/16"MAX. EDGE DISTANCE11/16"MAX. EDGE DISTANCE08/06/2020
3" PVCMULL BARIMPACTCWS-836 CADE09/27/12 SHEET DESCRIPTION: DRAWN BY: DATE: DWG #: REV.: SCALE:1:1SHEET8 OF 10LUCAS A. TURNER, P.E.FL PE # 582012428 Old Natchez Trc TrlCamden, TN 38320PH. 941-380-15741900 SW 44TH AVE.OCALA, FLORIDA 34474WWW.CWS.CCPROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED INTHIS DRAWING IS THE SOLEPROPERTY OF CUSTOM WINDOWSYSTEMS, INC. ANYREPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTENPERMISSION OF CUSTOM WINDOWSYSTEMS, INC IS PROHIBITED.MULL LENGTHOPENING SIZEOPENING SIZEMULL LENGTHOPENING SIZEMULL LENGTHMULL LENGTHOPENING SIZEOPENING SIZEMULL LENGTHTRANSOM OVER TWINVERTICAL MULLIONTRANSOM OVER TRIPLEVERTICAL MULLIONTWINVERTICAL MULLIONTRIPLEVERTICAL MULLIONSINGLE TWINORTRIPLEUNITSBELOWHORIZONTAL MULLIONCONFIGURATIONS ANDANCHORAGE NOTESNOTES:1. AT MULLION LOCATION, ATTACH WINDOW UNIT(S) TO MULLBAR THRU FRAME AS SPECIFIED IN WINDOW UNIT APPROVAL DOCUMENTS. IF ALUMINUM ATTACHMENT IS NOT SPECIFIED IN THE WINDOW UNIT APPROVAL DOCUMENTS, FOLLOW THE ANCHOR SPACING AS INDICATED IN THE WINDOW APPROVAL FOR ATTACHMENT TO WOOD SUBSTRATE, USING A HEX WASHER HEAD TEK SCREW OF THE SAME SIZE (#10 OR #12) AS THE WOOD SCREW INDICATED IN THE WINDOW APPROVAL. TEK SCREWS SHALL BE LONG ENOUGH TO ENSURE THREE (3) THREADS OF PENETRATION BEYOND THE INSIDE WALL OF MULLBAR.2. MULL CLIP INSTALLATION ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 9.3. ALL MULL CLIP INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTION.4. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM SPECIFIED IN TABLE 1, SHEET 9.5. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE - 1X BUCKS ARE OPTIONAL.6. A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED AS INDICATED BY THE PRE-DRILLED HOLES AS SHOWN IN THE CLIP LAYOUTS ON SHEETS 4-5.7. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLE1, SHEET 9. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED.8. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: FMA/AAMA 100(FIN WINDOWS), FMA/AAMA 200(FLANGE WINDOWS), FMA/WDMA 250(BOX WINDOWS), FMA/AAMA/WDMA 300(EXTERIOR DOORS)MULL LENGTHMULL LENGTHOPENING SIZEMULL LENGTHOPENING SIZEOPENING SIZEMULL LENGTHOPENING SIZETWINHORIZONTAL MULLIONTRIPLEHORIZONTAL MULLIONTWIN/TRIPLEHORIZONTAL MULLIONTWIN/TRIPLEVERTICAL MULLIONNOTES:1. THE MULL BAR IN FOCUS FOR ANY GIVEN CONFIGURATION IS SHOWN IN BOLD.2. AN INTERSECTED MULL BAR HAS OTHER MULL BAR(S) ATTACHED TO IT (SHOWN IN DASHES) THROUGH THE USE OF MULL BAR CLIPS. AN INTERSECTED MULL BAR WILL ALWAYS BE ATTACHED TO THE SUBSTRATE AT BOTH ENDS.3. NON-INTERSECTED MULL BARS CAN BE ATTACHED TO THE SUBSTRATE AND OTHER MULL BARS.08/06/2020
3" PVCMULL BARIMPACTCWS-836 CADE09/27/12 SHEET DESCRIPTION: DRAWN BY: DATE: DWG #: REV.: SCALE:1:2SHEET9 OF 10LUCAS A. TURNER, P.E.FL PE # 582012428 Old Natchez Trc TrlCamden, TN 38320PH. 941-380-15741900 SW 44TH AVE.OCALA, FLORIDA 34474WWW.CWS.CCPROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED INTHIS DRAWING IS THE SOLEPROPERTY OF CUSTOM WINDOWSYSTEMS, INC. ANYREPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTENPERMISSION OF CUSTOM WINDOWSYSTEMS, INC IS PROHIBITED.RETRO FITMULL BAR CLIPINSTALLATION ANCHORSEE TABLE 1INSTALLATION DETAILS FLANGETYPICAL FLANGE (RETRO FIT) ANCHORAGEHEAD AND JAMBS SIMILAR FOR FLANGE INSTALLATIONVERTICAL SECTIOND9SUBSTRATE TYPEANCHOR TYPEMIN. EMBEDMENT MIN. EDGE DIST.CONCRETE (2.0 KSI MIN.)3/16" ITW TAPCON1"3"CONCRETE (2.85 KSI MIN.)3/16" ELCO ULTRACON1-3/4"1"HOLLOW or GROUT-FILLED CMU (ASTM C-90) 1/4" ELCO ULTRACON1-1/4"2-1/2"2X MIN. SOUTHERN PINE (G=0.55)3/16" ITW TAPCONOR ELCO ULTRACON1-3/8"7/8"2X MIN. SOUTHERN PINE (G=0.55)#10 WOOD SCREW1-3/8"7/8"16 GAUGE (0.060") MIN. STEEL STUD (33 KSI YIELD MIN)#10-16 HILTI KWIK-FLEX OR ITW TEKS SELF-DRILLING SCREWFULL THREAD THRU 0.060"7/16"1/8" ALUM. (6063-T5 MIN.) OR 1/8" STEEL (33 KSI MIN.)#10 GRADE 5 SELF-TAPPING / DRILLING SCREWFULL THREAD THRU 0.125"7/16"TABLE 1: APPROVED MULL CLIP INSTALLATION FASTENERSADD STRUCTURAL ELEMENTSAS REQ'D TO MAKE LEVEL FORMULL BARSUBSTRATE BY OTHERSSEE TABLE 1PERIMETER SEALANTBY INSTALLERINSIDE AND OUTSEALANT ALONGOUTSIDE EXPOSEDEDGE BY INSTALLERMULL BARMIN. EMBEDMENTSEE TABLE 1"L" ANGLE MULL BAR CLIPTWO REQ'D PER EACH END OF MULLINSTALLATION ANCHORSEE TABLE 1TYPICAL FLANGE ("L" ANGLE) ANCHORAGEHEAD AND JAMBS SIMILAR FOR FLANGE INSTALLATIONVERTICAL SECTIONE9ADD STRUCTURAL ELEMENTSAS REQ'D TO MAKE LEVEL FORMULL BARSUBSTRATE BY OTHERSSEE TABLE 1PERIMETER SEALANTBY INSTALLERINSIDE AND OUTSEALANT ALONGOUTSIDE EXPOSEDEDGE BY INSTALLERMULL BARMIN. EMBEDMENTSEE TABLE 1MIN. EDGE DIST.SEE TABLE 1NOTES:1. BOX FRAME MULL INSTALLATION SIMILAR TO FLANGE FRAME.2. SILL STOOL MUST BE FLUSH AGAINST INSIDE OF MULLED WINDOWS AFTER INSTALLATION.3. RECESS RETRO MULLION CLIP 3/8" MAX. FOR CLEARANCE OF WINDOW UNIT AS NEEDED.4. FOUR (4) ANCHORS REQUIRED PER "T" MULL CLIP, SEE SHEETS 2-3. THREE (3) ANCHORS REQUIRED PER "L" MULL CLIP, SEE SHEETS 2-3.5. SEAT MULLION TIGHT TO MULL CLIP.6. FOR ANCHORAGE DETAILS FOR THE WINDOW, REFER TO THE WINDOW SPECIFIC INSTALLATION DETAILS.MIN. EDGE DIST.SEE TABLE 108/06/2020
3" PVCMULL BARIMPACTCWS-836 CADE09/27/12 SHEET DESCRIPTION: DRAWN BY: DATE: DWG #: REV.: SCALE:1:2SHEET10 OF 10LUCAS A. TURNER, P.E.FL PE # 582012428 Old Natchez Trc TrlCamden, TN 38320PH. 941-380-15741900 SW 44TH AVE.OCALA, FLORIDA 34474WWW.CWS.CCPROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED INTHIS DRAWING IS THE SOLEPROPERTY OF CUSTOM WINDOWSYSTEMS, INC. ANYREPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTENPERMISSION OF CUSTOM WINDOWSYSTEMS, INC IS PROHIBITED.TYPICAL FIN (RETRO FIT) ANCHORAGEHEAD AND JAMBS SIMILAR FOR FIN INSTALLATIONVERTICAL SECTIONF10INSTALLATION ANCHORSEE TABLE 1, SHT 9PERIMETER SEALANTBY INSTALLERINSIDE AND OUTSUBSTRATE BY OTHERSSEE TABLE 1, SHT 9EXTERIOR FINISHBY OTHERSMULL BARSEALANT ALONGEOUTSIDE EXPOSEDEDGE BY INSTALLERMIN. EMBEDMENTSEE TABLE 1, SHT 9MIN. EDGE DIST.SEE TABLE 1, SHT 9TYPICAL FIN ("L" ANGLE) ANCHORAGEHEAD AND JAMBS SIMILAR FOR FIN INSTALLATIONVERTICAL SECTIONG10RETRO FITMULL BAR CLIPINSTALLATION ANCHORSEE TABLE 1, SHT 9PERIMETER SEALANTBY INSTALLERINSIDE AND OUTSUBSTRATE BY OTHERSSEE TABLE 1, SHT 9EXTERIOR FINISHBY OTHERSMULL BARSEALANT ALONGEOUTSIDE EXPOSEDEDGE BY INSTALLERMIN. EDGE DIST.SEE TABLE 1, SHT 9"L" ANGLE CLIPTWO REQ'D PER EACH END OF MULLMIN. EMBEDMENTSEE TABLE 1, SHT 9NOTES:1. SILL STOOL MUST BE FLUSH AGAINST INSIDE OF MULLED WINDOWS AFTER INSTALLATION.2. RECESS RETRO MULLION CLIP 3/8" MAX. FOR CLEARANCE OF WINDOW UNIT AS NEEDED.3. FOUR (4) ANCHORS REQUIRED PER "T" MULL CLIP, SEE SHEETS 2-3. THREE (3) ANCHORS REQUIRED PER "L" MULL CLIP, SEE SHEETS 2-3.4. SEAT MULLION TIGHT TO MULL CLIP.5. FOR ANCHORAGE DETAILS FOR THE WINDOW, REFER TO THE WINDOW SPECIFIC INSTALLATION DETAILS.INSTALLATION DETAILS FIN08/06/2020