Lucas A. Turner, P.E.
FL PE #58201
Evaluation Report 836C
August 06, 2020
Product Description: PVC 3” Mullion H-1758
Manufacturer: Custom Window Systems, Inc. 1900 SW 44th Ave, Ocala, FL 34474
Statement of Compliance: This report evaluates the above-listed product per the requirements of
FAC Product Approval Rule Chapter 61G20-3.005 (4). This product complies with the requirements
of the 7th Edition (2020) Florida Building Code including the High Velocity Hurricane Zone. The
product testing standards performed are outlined below.
Technical Documentation:
1) This report, prepared by Lucas A. Turner, PE, at 2428 Old Natchez Trc Trl, Camden, TN
2) Approval drawing CWS-836C, signed and sealed by Lucas A. Turner, P.E.
3) Test Reports NCTL-210-3833-1, -1A, -2, -2A, -3, and -3A, from National Certified Testing
Laboratories, Orlando, FL signed and sealed by Gerard J. Ferrara, P.E.
a. Testing Performed: TAS 201/202/203-94, ASTM E 1886-02/04/05, ASTM E 1996-
04/06/09, and AAMA 450-06
4) Supplemental Calcs. to support CWS-836C, signed and sealed by Lucas A. Turner, P.E.
Installation: Units must be installed according to approval document CWS-836C.
Limitations of Use: This product:
• May be used up to the sizes and design pressures as shown in CWS-836C, using clips as
shown in CWS-836C
• Is Large Missile Impact Resistant and does not require the use of shutters
• May be used in the High Velocity Hurricane Zone
• May only be used with Custom Window System, Inc. windows, please see separate
individual window unit approvals for applicable design pressures and for more details. The
lower of the individual window design pressures and the mullion design pressures shall apply
to the entire assembly.
• Requires 6063-T6 aluminum mullion and clip extrusions.
Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a
financial interest in Custom Window Systems or in any company manufacturing or distributing
products for which this report is being issued. I do not have, nor do I intend to acquire, nor will I
acquire, a financial interest in any other entity involved in the testing or approval process of this
product.